| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.6 LAdmitted-Finance 638 GROUND FLOOR WEST GURU ANGAD NAGAR LAXMI NAGAR LAXMI NAGAR EAST DELHI DELHI 110092 UDYAM DL 02 0031392 | EAST DELHI | DELHI | 110092 | L1 | Admitted-Finance | ||
| 2 | L2₹3.6 L+₹3,205.97 (0.89%)Admitted-Finance H NO 732 BURARI VILLAGE DELHI 110084 | NORTH | DELHI | 110084 | L2 | Admitted-Finance | ||
| 3 | L3₹3.6 L+₹4,007.46 (1.11%)Admitted-Finance DELHI EAST DELHI 110092 INDIA UDYAM DL 02 0018735 | EAST DELHI | DELHI | 110092 | L3 | Admitted-Finance |
Tender Value
₹4.0 L
EMD Value
₹8,000
Closing Date
4 Nov 2026, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Puran Dass Kabeer
MUNICIPAL CORPORATION OF DELHI Office of the Executive Engineer E and M Central Zone Under Sewa Nagar Flyover , Lodhi Road , Delhi -03
Renovation and strengthing of EandM and allied work at Nizamuddin Village Pumping station.
2026_MCD_296090_1
EE(EandM)/MCD/2026-27/41
Open Tender
Electrical Works
Percentage
30 days
Lodhi Road
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
₹8,000
5 Nov 2026
28 Oct 2026
5 Nov 2026
28 Oct 2026
4 Nov 2026
28 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and fixing following rating, four pole, 415 V, isolator in the exisiting MCB DB complete with connections, Testing and commissioning etc. as requried 40 A | 1 | Each | 1,049 | ₹1,049 |
| 2 | Supply of corrugated & chequered rubber mat for electrical purposes exceeding IS 5424/69 Black or Red in 1M *2M of size 25 mm thickness | 1 | Each | 15,200 | ₹15,200 |
| 3 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1. 5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed pvc conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1. 5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C. | 14 | Point | 1,704 | ₹23,856 |
| 4 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required | 15 | Mtr | 373 | ₹5,595 |
| 5 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/ 6 A & 15/ 16 A modular socket outlet and 5/ 6 &15/ 16A modular switch, connections etc. as required. | 2 | Each | 659 | ₹1,318 |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/ 6 A modular socket outlet and 5/ 6 A modular switch, connections etc. as required. | 4 | Each | 545 | ₹2,180 |
| 7 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 8 way, Double door. | 1 | Each | 2,773 | ₹2,773 |
| 8 | Supplying and fixing 5 A to 32 A rating, 240/ 415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole. | 6 | Each | 285 | ₹1,710 |
| 9 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2. 5 sq. mm + 1 X 2. 5 sq. mm earth wire. | 10 | Mtr | 311 | ₹3,110 |
| 10 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. | 90 | Mtr | 482 | ₹43,380 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.10 MB
NewGCC.pdf
Tender Documents • 22.34 MB
TandC.pdf
Tender Documents • 0.39 MB
BOQ_345094.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .