Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹37.9 L
EMD Value
₹76,000
Closing Date
11 Jul 2024, 2:00 pmClosed
Er Surinder Kumar
ED Kathua
Creation of 03 Nos 100 KVA Sub Station alongwith HT LT line at Boura in respect JPDCL Electric Sub Division Kathua of Electric Division Kathua under JJM Scheme
2024_PDD_250700_1
KED 29 of 2024 25 Dated 19 06 2024
Open Tender
Electrical Works
Turn-key
30 days
SD Kathua
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
Executive Engineer ED Kathua
₹76,000
ED Kathua
10 Aug 2024
20 Jun 2024
13 Jul 2024
20 Jun 2024
11 Jul 2024
20 Jun 2024
20 Jun 2024 - 11 Jul 2024
28 Jun 2024
Amount
Creation of 03 Nos. 100 KVA Sub Station at Boura in respect JPDCL Electric Sub Division Kathua of Electric Division Kathua underJJM Scheme on Turnkey Basis by way of supply Erection/ Installation,Testing Commissioning of following Material:
11/0.433kV, 100 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ) up to 200 KVA, copper Wound and with LV Cable Box having detachable Aluminium Gland plate.
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
70mm² (1Ckt) Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long pole (ST-410 SP 33)
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution box for 100 KVA DTR with MCCB for incommer & SFU's for outgoing ckt
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedege connectors /PG clamps
Danger plate with clamps
GI Barbed wire for ani Clambing
3 Ph 4 Wire Trivector meter with CT
Cemetn bottomiing 1:2:4 mix as per REC standerds .5 Cum/pole
Painting of poles Red oxide
Painting of poles Aluminum Paint
Erection of HT line on 9 Mtrs. ST poles with ACSR Weasel Conductor at Boura in respect JPDCL Electric Sub Division Kathua of Electric Division Kathua underJJM Scheme on Turnkey Basis by way of supply Erection/ Installation,Testing Commissioning of following Material:
9 Mtr. Long pole (ST-410 SP 33)
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel x-arm includingclaps and braces
30 mm² ACSR Weasel Conductor
PG Clamps for ACSR weasel conductor
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamp
Anti Climbing Devices with clamps
Red oxcide Paint
Aluminium Paints
Cement Bottoming 1:2:4 mix as per REC Standrad 0.5 CUM per pole
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Aluminium Jointing Sleeves
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Erection of 3Nos 11 KV Tapping point at Boura in respect JPDCL Electric Sub Division Kathua of Electric Division Kathua underJJM Scheme on Turnkey Basis by way of supply Erection/ Installation,Testing Commissioning of following Material:
9 Mtr. Long Pole(ST-410 SP-33 )
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel/ angle iron including Clamps
11 KV GO , AB switch 3 phase , 3 pole , 200 amp vertically type
30 mm² ACSR Weasel Conductor
PG Clamps for 30mm2 ACSR conductor
11kV Polymeric composite Pin Insulator 12KV5kN, Lighting Impulse 75KV Positive and 80KVNegative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75KV Positive and 80KV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Cement bottoming 1:2:4 Mix as per REC Standars
Aluminium Paint
Red oxide paint
M/S SINGH ELECTRICAL CONTRACTOR AND SUPPLIERS
M/S ROHIT ASSOCIATES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .