Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹18 L
EMD Value
₹13,500
Closing Date
5 Nov 2026, 5:30 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
MR SE ENM RAIPUR RICHA(DFLT)
EinC E/M
Providing Annual Electrification Repair work in various Residential Buildings and Non Residential Buildings under PWD E/M Sub Division Kanker (C.G.)
202113
SYSTEM TENDER NO NIT NO: 134/S.E.E/M Raipur /2026-27 Dated:.16-10-2026
RESTRICTED TENDER
WORKS
PERCENTAGE
EinC E/M
Required Past Technical Experience: As per NIT
9 documents required · 9 mandatory
Public Works Department (PWD)
WORKS
MR SE ENM RAIPUR RICHA(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B C D
EinC E/M
E/M Circle, Raipur
E/M DIVISION KANKER
No
133
202113
5 Nov, 2026 5:30:00 PM IST
11 Nov, 2026 11:30:00 AM IST
16 Oct, 2026 6:30:00 PM IST
120
SYSTEM TENDER NO NIT NO: 134/S.E.E/M Raipur /2026-27 Dated:.16-10-2026
Providing Annual Electrification Repair work in various Residential Buildings and Non Residential Buildings under PWD E/M Sub Division Kanker (C.G.)
13500.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
1800000.00
2
10 Nov, 2026 5:30:00 PM IST
1800000
0.00
0.00
As per NIT
06
0.00 INR
19d 22h 54m
9 documents required · 9 mandatory
₹0
₹13,500
16 Oct 2026
16 Oct 2026
11 Nov 2026
16 Oct 2026
10 Nov 2026
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in surface complete as per specification and IS: 9537 (2000 Part 5) 2.15.1 20 mm
Supplying and fixing of following sizes PVC casing caping along with accessories in surface complete as per specification and IS: 9537 (2000 Part 5). 2.16.1 20x12 mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) 3.11.2 2 x 1.5 sq. mm
3 x 1.5 sq. mm
2 x 2.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
3 x 6 sq. mm
6 x 6 sq. mm
Supplying and fixing of following sizes wooden switch box made of wooden plank side wall and base including 3mm thick phenolic laminated sheet cover on surface complete as per specification 4.2.1 100mmX100mm
150mmX75mm
150mmX150mm
180mmX100mm
300mmX350mm
Supplying and fixing following piano type switch, socket, other accessories on the existing switch box/ cover including connections etc. as per specification. 5.1.1 5/6 amps one way switch
Bell push
15/16 amps switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Plug Top 3 pin 5/6 Amps (For light plug).
Plug Top 3 pin 16 Amps (For power plug).
Ceiling rose 3 pin 5 amps
Batten/ angle holder
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 5.4.1 5/6 amps one way switch
Bell push
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
6 pin 20 amp socket outlet
Fan regulator (one module size) electronic stepped type moving all rounds
Fan regulator (two module size) electronic stepped type moving all rounds
Ceiling rose 3 pin 5 amp
Batten/ angle holder
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification. 5.7.2 Deluxe
Providing and fixing following size FRLS PVC insulated, PVC sheathed, flexible copper conductor wire on the floor/ wall, or side of the table/ door etc. as per specification. 5.8.2 1.0 sq. mm two core
1.0 sq. mm three core
Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.17.2 5 Watt
Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.19.3 18/20 watt {4 feet}
36 watt {4 feet}
Supplying, fixing, testing and commissioning of following LED lamps {Inverter Type: with builtin battery backup} with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9.LED chip efficacy ratio ≥ 100 lumens /watt. 6.20.2 12 Watt
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 6.28.5 36 watt
Supplying, fixing, testing and commissioning of approved make following 230/250 volts electronic ballast in existing luminaries at all locations as per specification. P.F. should be greater than 0.9 6.33.1 For 36/40 watt T8 flu. Fitting
Supplying, fixing, testing and commissioning of glow type starter suitable for 36/40 watt T8 230/250 volts flu. lamp in existing luminaries at all locations as per specification.
Supplying, fixing, testing and commissioning of following 230/250 volts capacitors in existing ceiling fans/ exhaust fan at all locations as per specification. P.F. should be greater than 0.9 6.38.2 2.5 MFD
Supplying, fixing, testing and commissioning of following 230/250 volts capacitors for single phase motor at all locations as per specification. P.F. should be greater than 0.9 6.39.5 15 MFD
Providing and fixing wooden board of suitable size (18''x 24'') for energy meter etc complete as per specification.
Supply, Installation, testing and commissioning of following type LED Driver for LED Panel/down lights by approved make as required. 6.65.2 9-12 watt
Supply, Installation, testing and commissioning of following type LED Driver for LED Street lights / Flood Lights, IP 65 by approved make as required. 6.68.2 24 watt
Supplying and fixing metal clad busbar chamber made of 2.0 mm thick CRCA MS powder coated sheet with 4 strip copper busbars of following capacity and length, complete with all accessories, including earthing the body etc. as per specification. 7.8.2 4 100 amps x 450mm long
200 amps x 450mm long
Providing and fixing metal clad, TP&N switch fuse unit (re-wirable), 415/500 volts, with porcelain re-wireble fuses including drilling holes on the board, connections, earthing the body etc. as per specification. (Thimbeling shall be paid separately). 7.10.2 63 amps
Providing and fixing porcelain re-wireble fuse carrier and base unit on wooden board including drilling holes on the board, screws, connections etc. as per specification. (Thimbeling shall be paid separately). 7.11.2 32 amps
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 9.1.2 3 pole MCCB, 80-100A, Fixed Thermal Release, 10KA
3 pole MCCB, 25-100A, Adjustable Thermal Release, 18KA
3 pole MCCB, 200A, Adjustable Thermal - Magnetic Release, 35KA
Supplying and fixing on surface/ recess following way, 240 volts SP&N MCB distribution board of sheet steel phosphatized and powder painted complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.2.5 4 way, Double door
8 way, Double door
12 way, Double door
16 way, Double door
Supplying and fixing on surface/ recess horizontal type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.4.4 4 way Double door
6 way Double door
8 way Double door
Supplying and fixing SP MCB, 240 volts, 'B' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.10.1 6 amps to 32 amps
Supplying and fixing DP MCB, 240 volts, 'D' curve, suitable for inductive/ motor load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.13.3 40 amps
Supplying and fixing TP MCB, 440 volts, 'D' curve, suitable for inductive/ motor load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.15.3 40 amps
Supplying and fixing following rating, 240 volts TWO POLE ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.19.2 40 amps
Supplying and fixing following rating, 415 volts, FOUR POLES, ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.20.1 40 amps
Supplying and fixing sheet steel enclosure of suitable size made of 1.6mm thick CRCA MS sheet, for 100 amps MCCB on existing metal board/ wall including painting etc as per specification.
Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification.
Providing and fixing panel mounting digital type VAF (Volt-amp-frequency combined) meter of size 100x100 (NS) in existing cubical panel including connection, testing and commissioning etc. as per specification.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ concealed conduit/ submain wiring/ cable as per specification.
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 15.5.2 2 x 6 sq. mm
2 x 10 sq. mm
3.5 x 25 sq. mm.
3.5 x 35 sq. mm.
4 x 10 sq. mm.
4 x 16 sq. mm.
Supplying and hanging following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on GI bearer wire (binded at every metre) including cost of bearer wire complete as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1). 15.11.2 2 x 6 sq. mm. on 8 SWG GI bearer wire
2 x 10 sq. mm. on 8 SWG GI bearer wire
3.5 x 25 sq. mm. on 8 SWG GI bearer wire
3.5 x 35 sq. mm. on 7 SWG GI bearer wire
3.5 x 50 sq. mm. on 6 SWG GI bearer wire
4 x 10 sq. mm. on 8 SWG GI bearer wire
4 x 16 sq. mm. on 8 SWG GI bearer wire
Supplying, fixing and cramping suitable size and all type aluminium ferule/ lugs to following size 1.1 KV grade power cable core / lead, pressed with high pressure cramping tool including connection to switch gear/ MCCB etc as per specification. .15.28.3 16 sq. mm
Supplying and erection of angle/channel iron cross arms/ bracket/ other fitting of approved size and shape including drilling of holes for insulator pins, bolts and nuts etc as per specification.
Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as per specification 23.14.2 3x2.5 sqmm
3x4.0 sqmm
Repair of submersible motor parts 100 mm dia meter opening /Rewinding and assembly with testing etc complete and reinstallation including etc 23.19.3 Rewinding of motor upto 2 HP (single phase) waterproof copper winding wire
Oil seal/water seal/mechanical seal/rubber parts waterproof copper winding wire
Gun metal thrust bearing Axle
Bearing housing Lower
Revolving thrust Disc
Rewinding of ceiling fan by copper enameled wire of suitable gauge including all other required material i.e. insulation varnish, connection leads, oiling greasing etc complete with testing including dismantling & refitting of fan at site. (old copper wire will become the property of contractor) 31.1.1 48” (1200 mm sweep )
56” (1400 mm sweep )
Rewinding of Ex-Fan motor by copper enameled wire of suitable gauge including all other required material i.e. insulation varnish, connection leads, oiling greasing etc complete with testing including dismantling & refitting of fan at site. (old copper wire will become the property of contractor) 31.2.1 12” (300mm) Ex. Fan
15” (380mm) Ex. Fan
Cleaning, overhauling, servicing of ceiling/ Exhaust / wall bracket fan including greasing/ oiling, replacement of safety pins, check nuts, lock nut, nut bolts etc. making perfect alignment inluding dismentaling and refitting at site as per specification.
Replacement of defective ball bearing by approved make of suitable size bearing of all size of ceiling fan including dismentaling, disambling, assembling and reiftting as per specification.
Replacement of defective ball bearing by approved make of suitable size bearing of all size of exhaust fan including dismentaling, disambling, assembling and reiftting as per specification.
Supplying and replacing defective 2/3 KW heating element with approved make and suitable size in existing water heater/Gyser of any make, any capacity.
Supplying and replacing defective thermostat with approved make and suitable size in existing water heater/Gyser of any make, any capacity.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
486783385280678580_202113_Affidavit_affidavit.docx
NIT • 0.01 MB
2785993004417605549_202113_NIT_NIT kanker AR 18lac.xlsx
NIT • 0.03 MB
906462529035527780_202113_Term Condition and other Docu_Annexure E kanker AR 18lac.doc
NIT • 0.05 MB
906462529035527780_202113_Term Condition and other Docu_Approved Make List kanker AR 18lac.xlsx
NIT • 0.01 MB
906462529035527780_202113_Term Condition and other Docu_Cover letter kanker AR 18lac.docx
NIT • 0.02 MB
906462529035527780_202113_Term Condition and other Docu_FLYSHEET l NIT for kanker AR 18lac.doc
NIT • 0.03 MB
906462529035527780_202113_Term Condition and other Docu_Form A 2.13 kanker AR 18lac.doc
NIT • 0.15 MB
906462529035527780_202113_Term Condition and other Docu_Long mow.docx
NIT • 0.04 MB
906462529035527780_202113_Term Condition and other Docu_NEW NIT 2.10 for FORM A ON LINE (5) kanker AR 18lac.doc
NIT • 0.30 MB
906462529035527780_202113_Term Condition and other Docu_Proforma kanker AR 18lac.docx
NIT • 0.02 MB
906462529035527780_202113_Term Condition and other Docu_Short Notice mow.docx
NIT • 0.02 MB
906462529035527780_202113_Term Condition and other Docu_TS 36 26-27.docx
NIT • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .