Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹20.1 L+₹61,975 (3.19%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹20.3 L+₹89,864 (4.62%)Rejected-Finance 10TH MILE RISHI ROAD KALIMPONG DISTRICT DARJEELING PIN 734301 | KALIMPONG | DARJEELING | WEST BENGAL | 734301 | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹20.5 L+₹1.0 L (5.32%)Rejected-Finance | L4 | Rejected-Finance L1 being accepted | |
| 5 | L5₹20.7 L+₹1.3 L (6.52%)Rejected-Finance | L5 | Rejected-Finance L1 being accepted |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
22 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 867 EWS
GE 867 EWS C/O 99 APO PIN 913867
REPAIR/MAINTENANCE OF INTERNAL ELECTRIFICATION, GEYSERS AND EXHAUST FANS AT RHENOCK AND RONGLI UNDER GE 867 EWS
2020_MES_374060_2
CA NO GE / 867 / TOKEN / 33 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Rhenock
Refer Tender Documents
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹36,000
Yes
4 Nov 2020
10 Oct 2020
23 Oct 2020
10 Oct 2020
22 Oct 2020
17 Oct 2020
10 Oct 2020 - 15 Oct 2020
60 days
Amount
Supply & fixing batten (1x22) suitable for 1x4' LED tube light, Housing & cover made up of CRCA sheet steel. Epoxy powder coated Complete internal wiring suitable for retrofit LED tubelight with double side connections. LED tube rod should Excellent efficacy & performance having system power consumption not more than 20W, 240V, CRI ≥ 80, lumen output not less than 2100lm, CCT = 6500K, system efficacy > 105,including fixed with 02 Nos of PVC round/square block screws etc and connecting up with 3.0 core, 0.5 sqmm copper conductor sheathed from connector to ceiling rose including taking down existing fitting and making good disturbed surfaces complete all as specified and as directed by Engineer-in-Charge. Make: Cat part DMLN1LT8-16 of Fitting and LTT8-20 of rod (AL body) of Crompton or equivalent in Bajaj/Philips/Havells.
S&F 2' surface/wall mounted LED batten 10 watt, CCT - 5700K, system lumen output not less than 950lm, extruded aluminium housing with high quality Polycabonate diffuser, Operating temperature: -10° C to +45° C, Operating voltage range: 140-270 V, Average LED life L70B50: 50000 hours, CRI ≥ 80, system efficacy ≥95, including necessary screwing/fixing etc and connecting up with ceiling rose including taking down existing fitting and making good disturbed surfaces complete all as specified and as directed by Engineer-in-Charge. Make: Crompton Cat part No "LDL-10-CDL" or equivalent in Philips/Havells.
S&F LED Bulkhead fitting including 10 watt LED bulb, CCT - 5700K, IP-66/IK-09 system lumen output not less than 950lm, extruded aluminium housing with high quality Polycabonate diffuser, Operating temperature: -10° C to +45° C, Operating voltage range: 140-270 V, Average LED life L70B50: 50000 hours, CRI ≥ 80, system efficacy ≥95, including connecting up with 3.0 core, 0.5 sqmm copper conductor PVC sheathed from connector to ceiling rose including taking down existing fitting and making good disturbed surfaces complete all as specified and as directed by Engineer-in-Charge. Make: Crompton Cat part No "LBHP-10-CDL" or equivalent in Philips/Havells.
Supply & fixing LED security light suitable for 25 W LED with Housing Pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment with IP66 & top opening for easy maintenance, Ambient temperature: 35° C, Operating temperature: -10° C to +50° C, Operating voltage range: 140-270 V, Average life L70B50: 50000 hours, system power consumption not more than 20W, 240V, lumen output not less than 2500lm, CCT = 5700K, system efficacy > 105, including bracket made out of 25 mm dia light grade GI pipe not less than 1.2 mtr long bend to shape duly fixed with MS clamps, nut, bolts etc including connecting up with 3.0 core, 1.5 sqmm multicore copper conductor PVC sheathed from connector to ceiling rose including taking down existing fitting and making good disturbed surfaces complete all as specified and as directed by Engineer-in-Charge. Make: Crompton cat Part No "LST-25-CDL-M" or equivalent in Philips/Havells.
S&F in repairs switch piano, flush button, single pole, 5 amps, one way complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs switch socket combination 2 – in – one, 3 Pin / 5 Pin, 5 amps flush type complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs switch socket combination 2 – in – one 6 Pin , 5 / 15 amps flush type complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs ceiling rose 3 terminal /PVC/Polycarnonate, isolated body complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs lamp holder, PVC/polycorbonate insulated body with back plate for batten fittings complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs Bell push, flush type, 5 amps complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs Bell, Ding Dong, AC, 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge. Make for Item No. 5 to 11: (i) Anchor (ii) Plaza, (iii) Havells (Crabtree) (iv) ABB (v) Shalabh
S & F in replacement under repair fan regulator electronic type 100Watt 20V-50Hz complete all as specified and as directed by Engineer-in-Charge. Make: Anchor cat No 38660 or equivalent in (ii) Plaza, (iii) Havells (Crabtree) (iv) ABB (v) Shalabh
Supply and fix in repairs capacitor of 2.5 mfd complete all as directed by Engineer-in-Charge. Make:- CAPCO/ TIBCON/ CROMPTON
S&F in repair side holder / bipin holder of FTL/ T-5 lamp and suitable for CFL light fitting of any type and capacity as per sample complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement under repair 9W LED Bulb suitable for B22 holder, System Efficacy be > 85 lm/ W. PF > 0.9, Cool Daylight Color temp of 6500K, lumen output >800 lm complete all as directed by Engineer-in-Charge. Make:- Philips/Wipro/Crompton
S & F in replacement under repair 7W LED Bulb suitable for B22 holder System Efficacy be > 85 lm/ W. PF > 0.9, Cool Daylight Color temp of 6500K, lumen output >600 lm complete all as directed by Engineer-in-Charge. Make:- Philips/Wipro/Crompton
S&F in repairs 4' LED tube light, LED tube rod with Excellent efficacy & performance having system power consumption not more than 20W, 240V, CRI ≥ 80, lumen output not less than 2100lm, CCT = 6500K, system efficacy > 105 complete all as directed by Engineer-in-Charge. Make:- Crompton Cat Part No LTT8-20 (AL Body) or equivalent in Philips/Havells
M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping, medium grade of suitable size with all necessary fittings, fixed on walls/ceilings etc., including 1.5 Sq mm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes concealed type/surface type for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover (Make: Hylem or equivalent ) for housing switches, socket outlet, regulator etc., for one light /fan point controlled by one switch/one bell / buzzer point controlled by one bell push/one 3 / 5 -pin switch socket outlet 5 amps on independent board including taking down existing unserviceable point wiring terminal boxes and making good disturbed surfaces including testing on completion complete all as specified and directed by Engineer-in-Charge.
All as per item No. 18 above but for One 3/5 pin switch socket outlet 5 amps on same board along with other switches complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 2.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping, medium grade of suitable size with all necessary fittings, fixed on walls/ceilings etc., including 2.5 Sqmm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes concealed type/surface type for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover (Make: Hylem or equivalent ) for housing switches, socket outlet, regulator etc., for one 5 / 6 -pin switch socket outlet 15 amps on independent board including taking down existing unserviceable point wiring including terminal boxes and making good disturbed surfaces including testing on completion complete all as specified and directed by Engineer-in-Charge. Make for Item No. 18 to 20 Cable: (i) Finolex, (ii) Plaza, (iii) Havells, (iv) Polycab, (v) KEI, (vi) Anchor Casing&Caping: (i) Kinjal, (ii) Alwyn (iii) Harsh, (iv) Finolex (v) Berlia (vi) Plaza
Dismantling damaged wooden boards of Electric meter by disconnecting all electric connection and S&F rectangular teak wood board of size 30cm x 25cm x 5cm deep with smooth hylem sheet top 3mm thick for mounting Electric Meter including making holes for incomming and outgoing wires and making necessary electrical connections complete all as specified and directed by Engineer-in-Charge.
S&F sheet metal enclosure DB SPN 12 way 240 V with 200 Amp rated bus bar, powder coated double door including taking down old unserviceable DB complete all as specified and as directed by Engineer-in-Charge.
S&F sheet metal enclosure DB SPN 8 way 240 V with 200 Amp rated bus bar, powder coated double door including taking down old unserviceable DB complete all as specified and as directed by Engineer-in-Charge.
S&F sheet metal enclosure DB SPN 4 way 240 V with 200 Amp rated bus bar, powder coated, double door including taking down old unserviceable DB complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing of MCB SPN 40 Amps, 10 KA breaking capacity, 240 volts, 50 Hz including taking down old unserviceable MCB complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing of MCB SPN 32 Amps, 10 KA breaking capacity, 240 volts, 50 Hz including taking down old unserviceable MCB complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing of MCB SP 40 Amps, 10 KA breaking capacity, 240 volts, 50 Hz including taking down old unserviceable MCB complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing of MCB SP 6 to 32 Amps, 10 KA breaking capacity, 240 volts, 50 Hz including taking down old unserviceable MCB complete all as specified and as directed by Engineer-in-Charge. Make for Item No. 22 to 28: Legrand / Siemens/Schinder/L&T.
M&L for sub main wiring complete with 2 runs of 6 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor and drawing through and including non metalic rigid PVC conduit of 25mm dia medium grade fixed on wall/ceiling and connecting terminal ends including provision of 1 run of 6 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor as earth continuity conductor and connecting to earth dolly including taking down old unserviceable wiring and making good disturbed surfaces complete all as directed by Engr-in-charge. Note: 2 runs of 6 Sqmm and one run of 6 Sqmm and one run of conduit shall be measured as one unit length.
M&L for sub main wiring complete with 2 runs of 4 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor and drawing through and including non metalic rigid PVC conduit of 25mm dia medium grade fixed on wall/ceiling and connecting terminal ends including provision of 1 run of 4 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor as earth continuity conductor and connecting to earth dolly including taking down old unserviceable wiring and making good disturbed surfaces complete all as directed by Engr-in-charge. Note: 2 runs of 4 Sqmm and one run of 4 Sqmm and one run of conduit shall be measured as one unit length. Make for Item No. 29&30 Cable: (i) Finolex, (ii) Plaza, (iii) Havells, (iv) Polycab, (v) KEI, (vi) Anchor Conduit: (i) Kinjal, (ii) Alwyn (iii) Harsh, (iv) Finolex (v) Berlia (vi) Plaza
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI medium grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1:3:6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, 15 mm GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I including taking out existing earth plate etc., complete all as specified and as directed by Engineer-in-Charge. NOTE: Rate quoted shall be deemed to include for earth lead and protection pipe upto 7.5m.
Taking down existing exhaust fan (any type, make & sweep) at location of installtion and supply and fixing of exhaust fan of 450mm sweep, 1400 rpm, 6800cmh, including necessary louvers including connecting up with PVC insulated 3 core sheathed 1.5 sqmm copper conductor upto ceiling rose complete all as specified and as directed by Engineer-in-charge. Make: Model No : "Supreme DLX" of make 'Bajaj' or equivalent model of Almonard/Havells Note : Old unserviceable Exhaust fan shall be deposited to AGE B/R Pedong store.
Taking down existing exhaust fan (any type, make & sweep) at location of installtion and S&F of Exhaust fan 200 mm sweep 1300 RPM with minimum airflow/air delivery 450 Cmh, light weight, rust proof body & blades, self opening louvers for protection from birds & rain water, IP-55, 200-240 Volt AC supply, rated power input not more that 30watt, connecting up including provison of cable from ceiling rose to fan complete all as specified and as directed by Engineer-in-charge. Make: Crompton Greaves, Model : BRISK AIR , or equivalent in USHA/Bajaj. Note : Old unserviceable Exhaust fan shall be deposited to AGE B/R Pedong store.
Taking down existing exhaust fan (any type, make & sweep) at location of installtion and Supply, fixing, testing & commissioning of exhaust fan 300 mm sweep 1400 RPM with minimum airflow/air delivery 1710 Cmh, totally enclosed heavy duty motor, die cast aluminium rotor mounted on double ball bearing, IP-55, polarity-4, 230 Volt AC supply (single phase), rated power input not more that 90watt, with louvers and connecting up including provision of PVC insulated overall PVC sheathed copper conductor cable from ceiling rose to fan complete all as specified and as directed by Engineer-in-charge. Make: Crompton Greaves model No EXHD300-4-1 or equivalent in USHA/Bajaj. Note : Old unserviceable Exhaust fan shall be deposited to AGE B/R Pedong store.
S&F sheet metal AC earth plug and socket of 3 pin with neutral with MCB SP 20 Amps 240 Volts including taking down existing unserviceable fitting complete all as specified and as directed by Engineer-in-Charge. Make: Legrand / Siemens/Schinder/L&T.
S&F in repairs Decorative, wall mounting fixture in durable plastic body & designer mesh in gold finish suitable forand including 14 W retrofit LED lamp including necessary connection with 0.5 sqmm PVC sheathed 3 core copper cable complete all as directed by Engineer-in-Charge. Make:- Model "Glaze" of Havells or equivalent in Philips/Bajaj
Taking down existing unserviceable service cable of any size and S&F 1100 volts grade heavy duty PVC insulated stranded aluminium conductor cable of cross-sectional area 10 Sqmm size (one twin core cable flat or circular, served with inner sheathing of PVC tape and overall PVC sheathed) in service connections, suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire and testing on completion complete all as specified and as directed by the Engineer-in-Charge. MAKE:- ANCHOR/FINOLEX/PLAZA/ HAVELLS/ HPL/ POLYCAB/KEI
Supply and fix in repairs 1.5 KW capacity Heating Element, triangular type with necessary washer including making electrical connection complete all as directed by Engineer-in-Charge.
Supply and fix in repairs 2.0 KW capacity Heating Element, triangular type with necessary washer including making electrical connection complete all as directed by Engineer-in-Charge. Make for Item No. 42&43 Bajaj/Venus/Racold/Havells/Crompton/Power pack or equivalent as approved by GE.
Supply and fixing PVC connection heavy duty with brass /PTMT nuts of reqd |ength not exceeding 300 mm with rubber/ PVC washer suitable for 15 mm bore GI pipe for cold water complete all as specified & directed by Engineer-in-Charge. Make:- PRAYAG/POLYTUFF or equivalent as approved by GE.
Supply & fixing in replacement 300mm long chromium plated copper pipe connection (Heavy Duty) with two numbers brass adopters for fixing one end at geyser & other end at water outlet point for hot water complete all as specified and directed by Engineer-in-Charge.
Supply & Fix in repairs Thermostat switch (automatic cut off) for geysers 25/ 50 Ltr capacities including making connection complete all as directed by Engineer-in-Charge.
Supply and fixing in replacement safety valve spring locked type with inlet coupling all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement indicator lamp round /rectangular and making electric connections (Red/Green) 220 Volts AC as per site requirement suitable for geysers complete all as directed by Engineer-in-Charge.
S&F in repairs Stop/Angle valves 15 mm bore, cast copper alloy chromium plated screwed down high pressure, with crown or capstan head, concealed type with long shank ang cup screwed both ends for iron pipe or for unions all as specified and directed by Engr-in-Charge. Make: SEIKO/RYBO/SPECTRUM/ NMC/L&K/ESSCO (DELUXE)
Supply and fixing Water heater storage type (Geyser), electric driven single phase 230 volt, 50 Hz of capacity 25 litres complete in all respect including grouting to wall with suitable size of nut, bolt and connecting with necessary electrical system including taking down existing Gerser complete all as specified and directed by Engineer-in-Charge. Make: USHA Model "Misty 25 Ltr 2000Watt storage water heater" or equivalent in Racold/Havells. Note: Old unserviceable Geyser shall be deposited to AGE B/R Pedong store.
Taking down existing un-serviceable/rusted House service bracket and S&F new House service bracket (hook type) complete with 3.0 m long GI pipe 40mm dia light grade, fixed with two nos 90º bends, MS hooks and stay or guy, mild steel clamps with required numbers of nut-bolts of suitable sie including applying two coats of synthetic enamel paint oer a coat of red oxide zinc chrome primer complete all as specified and as directed.
S&F in repairs 2'x2' LED ceiling light fully diffused recessed mounted 2'x2' LED luminaire with high transmitive diffuser suitable for indoor spaces including LED bulb and necessary connection and dismantling of existing defective fitting complete all as directed by Engineer-in-Charge. Make:- Crompton cat part No "LCTLRNE-36-FO-CDL" or equivalent make in Philips/Havells.
S&F in repairs LED PL Lamp without changing the conventional fittings including necessary connection and dismantling of existing defective lamp complete all as directed by Engineer-in-Charge. Make:- Philips cat part No. LED PL-L 18W, 6500K 2G11 or equivalent in Crompton/Havells.
Sub Total of Schedule 'A'
Schedule of Credit (Minus) Rs. 21,851.00 B/F from Ser page No. 30 NOTE: Bidder shall insert credit amount as rate Rs. 21,851.00 in Green field under Col-M. If bidder does not insert the amount the same will be deducted from total amount of Schedule 'A' and accordingly total amount of tender will be considered in deciding the lowest tender.
Sub Total of Schedule of Credit
SANJAY SAW MILL
GARGO TRADERS
MS BRAHMA CONSTRUCTION
DEEP CHANDRA JOSHI
SANJAY MITTAL
JAYSHREE CONCERN
HEM RAJ GURUNG
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .