Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
11 Mar 2023, 6:00 pmClosed
GE Narangi
GE Narangi C/o 99 APO
REPAIR TO UNSV SECURITY LIGHTS FLOOD LIGHTS STREET LIGHT PANELS DAY TO DAY INTERNAL ELECTRIFICATION WORKS AND VARIOUS TYPES OF PUMPS AND OTHER MACHINERIES AT VARIOUS INSTALLATION INCLUDING DEVELOPMENT OF BOREWELL UNDER GE NARANGI
2023_MES_579373_2
8812/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE Narangi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Narangi
₹80,000
Yes
17 Mar 2023
23 Feb 2023
13 Mar 2023
23 Feb 2023
11 Mar 2023
25 Feb 2023
Amount
Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but including switches, ceiling roses, pendants, regulators, sockets, etc. and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed.
M&L for point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 drawn in and including PVC Casing and Caping with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one 5 Amps switch one way complete all as specified and directed.
All as item No 2 here-in-before but for one light point controlled by 2- two way 5 Amps switch
All as per item No 2 here-in-before but for one 3 pin 5 Amp switch socket outlet on independent board
All as per item No 2 here-in-before but for one 3 pin 5 Amp socket outlet on same board with other switches.
All as per item No 2 here-in-before but for one bell point controlled by one switch 5 Amps bell push.
All as per item No 2 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.
M&L for point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 drawn in and including concealed conduit including all accessories with fabricated MS terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one 5 Amps switch one way complete all as specified and directed.
All as item No 8 here-in-before but for one light point controlled by 2- two way 5 Amps switch
All as per item No 8 here-in-before but for one 3 pin 5 Amp switch socket outlet on independent board
All as per item No 8 here-in-before but for one 3 pin 5 Amp switch socket outlet on same board with other switches.
All as per item No 8 here-in-before but for one bell point controlled by one switch 5 Amps bell push.
All as per item No 8 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.
S&F in repair modular switch one way 6 Amps 1 module complete all as specified and as directed.
S&F in repair modular switch one way 16 Amps 1 module complete all as specified and as directed.
S&F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
S&F in repairs, switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
S&F in repairs, switch piano, flush type single pole one way 15 Amps 230 volt complete all as specified and as directed.
S&F switch piano, flush type single pole two way 5 Amps 230 volt complete all as specified and as directed.
S&F bell push, flush type, 5 Amps complete all as specified and as directed.
S&F in repairs, bell push, flush type, 5 Amps complete all as specified and as directed.
S&F in repairs, modular bell push, 6 Amps 1 module complete all as specified and as directed.
S&F in repair modular socket 6 Amps 2/ 3 pin, combined 2 module complete all as specified and as directed.
S&F in repair modular socket 16 Amps 2/ 3 pin, combined 2 module complete all as specified and as directed.
S&F socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as specified and as directed.
S&F in repairs, socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as specified and as directed.
S&F switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
S&F in repairs, switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
S&F switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
S&F in repairs, switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
S&F in repairs, socket outlet multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
S&F lamp holder insulated, PVC / polycarbonate /bakelite body complete all as specified and as directed.
S&F in repairs, lamp holder insulated, PVC / polycarbonate /bakelite body complete all as specified and as directed.
S&F stepped type electronic fan regulator, two module size, flush type complete all as specified and directed.
S&F in repairs,stepped type electronic fan regulator, two module size, flush type complete all as specified and directed.
S&F ceiling rose surface bakelite 65x50mm three terminal complete all as specified and as directed.
S&F in repairs, ceiling rose surface bakelite 65x50mm three terminal complete all as specified and as directed.
S&F call bell Ding Dong AC ,230 volts single pole complete all as specified and as directed.
S&F in repairs, call bell Ding Dong AC ,230 volts single pole complete all as specified and as directed.
S&F in repairs, modular fan regulator 120 W-2 module complete all as specified and as directed.
S&F in repairs, modular cover plate white with frame , 1 module all as specified and as directed.
S&F in repairs, modular cover plate white with frame , 3 module all as specified and as directed.
S&F in repairs, modular cover plate white with frame , 4 module all as specified and as directed.
S&F in repairs, modular cover plate white with frame , 6 module all as specified and as directed.
S&F in repairs, metal flush box 3 module all as specified and as directed.
S&F in repairs, metal flush box 4 module all as specified and as directed.
S&F in repairs, metal flush box 6 module all as specified and as directed.
Taking out existing unserviceable switch board plates any type, dismantling switches carefully, stacking at site for use of serviceable switches and supply and fixing new 3mm thick masonite laminated sheet top cover fixed on 6 inch x 10 inch MS box with brass screw for mounting switches, sockets, regulator etc including making necessary electrical connection with 1.5 sqmm single core copper multistranded cable complete all as specified and directed. (Note : New Switches, sockets, fan regulators etc if required will be measured and paid separately under relevant items).
Taking out existing unserviceable switch board plates any type, dismantling switches carefully, stacking at site for use of serviceable switches and supply and fixing new 3mm thick masonite laminated sheet top cover fixed on 4 inch x 8 inch MS box with brass screw for mounting switches, sockets, regulator etc including making necessary electrical connection with 1.5 sqmm single core copper multistranded cable complete all as specified and directed. (Note : New Switches, sockets, fan regulators etc if required will be measured and paid separately under relevant items).
Taking doen carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fitting, bulkhead fitting, tubelight fittings, and regulators etc. keeping in safe custody for refixing serviceable fittings/fixtures and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including making good surfaces of walls, floors etc complete all as specified and directed.( To be measured only when found serviceable).
S&F in repair LED light fitting of approved make 1X 20 W, 220V, AC decorative box type with driver, holder including LED lamp and connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
S&F in repairs, decorative hexagonal bulk head LED luminaire 10 Watt, 6000K with IP 66 protection complete all as specified and as directed. Model HEXAFT10WLED857SSYMBOPC Make Havells or equivalent model of make Philips /GE/Crompton.
S&F in repairs, LED light fitting mirror type with high out put difffuser 2 feet, 10 Watt 220 V AC with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete..
S&F in repairs, LED 40 Watt post top made in cast aluminium with decorative opal polycarbonate diffuser with IP65 protection suitable for dia upto 60mm. Make : Bajaj/ Crompton/ Philips/GE.
S&F in repairs, wall decorative fixtures in durable body and designer mesh in gold finish suitable for 9 Watt LED lamp of B-22, including lamp of 9 Watt. Make: Havells Cat No. LHFOECE1T1B014 or equivalent in Crompton/ Philips/GE.
Disconnecting the main power supply to distribution box and making proper dressing of SPN/TPN/VTPN MCB/MCCB DBs of preconnected MCBs by replacing screws of DB covers, earth wires, and other necessary connecting items and dressing of wires inside the DB with cable tie complete all as directed.
S &F street light fitting of 35 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 5 kV complete including taking down old unserviceable light fittings complete all as specified and as directed. NOTE : Manufacturer’s test certificate of LED light fitting in respect to LM 79 and LM 80 shall be submitted by the contractor.)
S&F in repairs, LED35 W building security light made up of pressure die cast housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07 and suitable for dia upto 43 mm complete all as specified and as directed .Make -Havells ,/ Philips Bajaj /GE/Crompton.
S &F street light fitting of 60 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 5 kV complete including taking down old unserviceable light fittings complete all as specified and as directed. NOTE : Manufacturer’s test certificate of LED light fitting in respect to LM 79 and LM 80 shall be submitted by the contractor.
S&F in repairs street light fitting OF 70w LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC cover having tip opening separate driver compartment, should have luminarie efficacy >110 lumens/watt, CR<70, PF> 0.95, CCT > 5500, IP 66, impact resistance IK 07, inbuilt protection against lightening, over voltage, short circuit and surge/spike protection device upto 5kV complete all as as specified and as directed by Engr in charge
M&L connecting junction box to street light luminaire using wiring with two runs (P-N) single core 1.5 sqmm ( nominal area) FR PVC insulated and unsheathed multistranded copper conductor cable 1100 V grade and one run of FR PVC insulated and unsheathed multistranded copper conductor cable of size 1.5sqmm single core as earth continuity wire drawn through PVC conduit and tiding the same with aluminium strip with the pole complete all as specified and directed. Note: ( Two single core 1.5 sqmm cable and one single core 1.5sqmm earth conductor cable and one run of PVC conduit shall be measured as one run).
S&F in repair street light junction box of size 250mmX200mmX105mm made of high quality sheet moulding compound with IP 65 protection ( Dust and vermin proof as per IEC 60529) totally insulated with MCB, DP, 10 KA, 6 Amps to be fixed on Din rail, with locking arrangement with cable gland suitable upto 10 sqmm cable and necessary fixing arrangements such as clamps, nuts, bolts etc complete.
S&F in repairs, factory made, sheet steel distribution boards, TPN, 4 Way, protection class IP-43 with min 100 Amp rating copper bus bar, provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and as directed .
S&F in repairs, factory made, sheet steel distribution boards, IP-43 of double door VTPN 4 way with 250 Amps rated copper bus bar 415 volt and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and as directed .
S&F in repairs, single pole & neutral DBs, 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar grouted in wall in PCC 1:2:4 type B-1 complete all as specified and as directed.
S & F SPN DBs 4 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed.
S&F in repairs, MCCB four pole 63A, Icu16KA, thermal magnetic, 415v AC complete all as specified and as directed.
S&F in repairs, MCB TPN of capacity 40A to 63A,10 KA, type 'C' curve, 240 Volts, complete all as specified and as directed.
S&F MCBs, SPN 32 Amps, 240v 10 KA, 'C' curve complete all as specified and as directed.
S&F MCBs, SP 6 to 32 Amps, 10 KA, IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed.
S&F in repair heavy duty metallic exhaust fan AC single phase 230/240 Volts of size 300mm sweep with louver shutter with frame including necessary fixing accesssories writing MES No. with black synthetic enamel paint with 2cm high letter and connecting up including provision of three core copper flexible cable with flexible wire cover of plastic white in colour , connecting from ceiling rose to fan terminal complete all as specified and as directed. Make Usha Model CRISP AIR LX Exhaust Fan or equivalent as approved.
Taking down fan of any type/make and size of AC ceiling fan, carefully from fan hook, and transporting from any location inside army area to MES E/M store yard, and refixing on same location or other location after repairing complete all as specified and as directed.
Strip opening of ceiling fan 1200 /1400 mm sweep, cleaning thoroughly bush & ball bearing by petrol, washing/cleaning fan blades with caustic soda thoroughly, provision of fresh greasing, replacement of worn out/defective unserviceable parts (wherever necessary) reassembling the same and testing the fan on full load to entire satisfaction of Engineer-in-Charge. Note:- Replacement of defective/ unserviceable parts shall be measured and paid separately in respective items as supply only.
Cutting the existing copper winding of AC ceiling fan 1200 mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size including provision of twisted twin core flexible wire upto 0.7 meters long size 24/0, 020 (ISI marked) all insulating materials including varnishing, heating and drying complete including satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.
Cutting the existing copper winding of AC ceiling fan 1400 mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size including provision of twisted twin core flexible wire upto 0.7 meters long size 24/0, 020 (ISI marked) all insulating materials including varnishing, heating and drying complete including satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.
Supply only ball bearing of size 6201/6202 for any type/make of ceiling fan 1200/1400 mm sweep all as directed. (Make : NBC/SKF/SBBI)
Supply only fan capacitor 2.5 Mfd suitable for 1200/1400 mm sweep all as directed. (Make : NBC/SKF/SBBI)
Supply only rubber reels including shackle clamp, bolts, nuts, washers split pins of appropriate size as required.
Supply only down rod 15mm dia GI pipe heavy duty 45 cm long including machining/ threading/drilling hole of size suitable for nuts and bolts washer and split pin suitable for any size and make of fan.
Supply only plastic canopy upper & lower of any size and make of ceiling fan fixed with suitable size of screws complete all as specified and as directed.
Taking down exhaust fan of size 200mm to 450mm sweep of any make and transporting from any location inside army area to MES E/M store yard, and refixing on same location or other location carefully after repairing, washing by petrol ,greasing, replacement of worn out/defective unserviceable parts (wherever necessary) assembling the same including provision of twisted twin core flexible wire upto 0.7 meters long size 24/0, 020 (ISI marked) and testing the fan on full load to entire satisfaction of Engineer-in-Charge complete all as specified and as directed. Note :- Note:- Replacement of defective/ unserviceable parts shall be measured and paid separately in respective items as supply only.
Cutting the existing copper winding of AC exhaust fan 200mm to 450mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size including provision of twisted twin core flexible wire upto 0.7 mtrs long size 24/0, 020 (ISI marked) all insulating materials incl varnishing, heating and drying complete incl satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.
Supply and fix in repair ball bearing suitable for exhaust/wall fan upto 450 mm sweep all as directed. (Make : NBC/SKF/SBBI)
Supply only condenser ISI marked 230/240/250 volts AC 4 Mfd suitable for exhaust fan including condenser spacer and soldering of condenser wire to fan wire (Make : Usha/Asian/EPCOS/Universal).
M&L for dressing of pre-wired casing caping/PVC conduit of One light/fan/exhaust fan point controlled by one number one way 5 Amp switch by changing Casing caping /PVC conduit and necessary connecting items (such as flexiable conduit ,screws etc) includind making good disturbed surface of wall/ceiling complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of 6.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia non metallic PVC grey conduit conforming to IS-9537 with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduitcomplete all as specified and as directed. Note : Three runs of cable and one run of PVC conduit will be measured as one Rm unit.
M & L for Sub main wiring with 2 runs of 4.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia non metallic PVC grey conduit conforming to IS-9537 with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduitcomplete all as specified and as directed. Note : Three runs of cable and one run of PVC conduit will be measured as one Rm unit.
Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable , etc. n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading, levelling watering and well ramming in layers not exc 25 cm thick for any type of soil complete all as specified and as directed.
Removing surplus soil to a distance not exc 50m and depositing at level not exc 1.5m above the starting point complete all as specified and as directed.
Taking out old unserviceable UG cable of any size/ type from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and as directed.
Relaying old serviceable UG cable of any size/ type alongwith brick protection, sand cushioning etc as obtained from taking up/down old cable here in before in trenches/ wall/ roof etc. after necessary repair/ rerouting if directed complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 10 sqmm 2 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 6 sqmm 2 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
Supply and spreading clean dry river sand in cable trenches as in cable cushioning complete all as specified and as directed. (Note: Punned thickness shall be measured and paid)
M&L for Sub class ‘B’ old size well burnt brick laid flat in trenches over the cable for protection of LT cable complete all as specified and as directed.
M& L for Manual boring under roads / hard standing by required T&P without disturbing the top surface of the road for passing the cable in GI Pipe of 40 mm to 100mm dia complete all as specified and as directed.
M&L for GI pipe light grade 40mm bore with all fittings laid in trenches or in floors, including taking up/ down old pipe complete all as speciffied and as directed
Supply and fix in repair 3 pole power contactor of AC3 rating 40 Amps , with built in surge suppressor , RoHS compliant including necessary electrical connection with suitable size of copper cable complete all as specified and directed. (Make : L&T Cat Part No. SS90721 or equivalent in Havells/C&S)
Supply and fix in repair Astronomical time switch single Phase operates on 110-240V AC including all necessary connection complete all as specified and directed. (Make: L&T Cat Part No. T2DDT7 or equivalent in Havells/C&S)
Supply and fix in repair coil for contactor MO 32 , 415 V complete all as specified and directed. (Make: L&T Cat Part No. CS96317R0000 or equivalent in Havells/C&S)
Supply and fix in repair coil for contactor MO 50 , 415 V complete all as specified and directed. (Make: L&T Cat Part No. CS96318R0000 or equivalent in Havells/C&S)
M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6.3mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including 4mm dia GI wire upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 15mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal,salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including demolition of old earthing complete all as specified and as directed.
Taking out carefully submersible pump of capacity of 6HP to 10HP any make and model from the borewell (350 ft-600ft depth) compelte with column pipe of size 50mm dia and other connected parts and lowering the same after necessary repair of the pump/development of borewell and replacement of nut bolts, gasket suitable size all as per requirement complete all as directed by Engr-in-Charge.Note- (i) All T&P required shall be supplied by contractor without any extra cost
Taking out carefully submersible pump of capacity up 12.5 to 25HP any make and model from the UG sump by disconnecting electric connection, opening nuts & bolts from delivery line and other connected parts and lowering the same after necessary repair works of the pump set and replacement of nut bolts, gasket suitable size all per requirement complete all as directed by Engr-in-Charge. Note- (i) All T&P required shall be supplied by contractor without any extra cost.
M&L for Strip opening of 3 phase AC submersible 3 HP motor any type and taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including seal PVC (water proof compound) and jointing new submersible cable at least 6m long with water proof tape, re-assembling the motor and testing complete . Note : Quoted rates are deemed to be inclusive of all required T&P including transportation of motor from site to workshop and back to site after necessary repair works.
M&L for Strip opening of 3 phase AC submersible 6 HP motor any type and taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including seal PVC (water proof compound) and jointing new submersible cable at least 6m long with water proof tape, re-assembling the motor and testing complete . Note : Quoted rates are deemed to be inclusive of all required T&P including ransportation of motor from site to workshop and back to site after necessary repair works.
M&L for Strip opening of 3 phase AC submersible 10 HP motor any type and taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including seal PVC (water proof compound) and jointing new submersible cable at least 6m long with water proof tape, re-assembling the motor and testing complete . Note : Quoted rates are deemed to be inclusive of all required T&P including ransportation of motor from site to workshop and back to site after necessary repair works.
M&L for Strip opening of 3 phase AC submersible 20 HP motor any type and taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including seal PVC (water proof compound) and jointing new submersible cable at least 6m long with water proof tape, re-assembling the motor and testing complete . Note : Quoted rates are deemed to be inclusive of all required T&P including ransportation of motor from site to workshop and back to site after necessary repair works.
M&L for Strip opening of 3 phase AC submersible 40 HP motor any type and taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including seal PVC (water proof compound) and jointing new submersible cable at least 6m long with water proof tape, re-assembling the motor and testing complete . Note : Quoted rates are deemed to be inclusive of all required T&P including ransportation of motor from site to workshop and back to site after necessary repair works.
Taking out worn out bearing bush sleeves from the motor of capacity 6 to 10 HP and providing new stainless steel sleeve , turning and polishing of sleeve complete in all respect all as specified and directed.
Taking out worn out bearing bush sleeves from the motor of capacity 20HP to 40 HP and providing new stainless steel sleeve , turning and polishing of sleeve complete in all respect all as specified and directed.
Taking out worn out bearing bush sleeves from the motor of capacity 3 HP and providing new stainless steel sleeve , turning and polishing of sleeve complete in all respect all as specified and directed.
S & F in replacement of thrust plate alongwith disc of motor of capacity 6 HP to 10 HP.
S & F in replacement of oil seal of motor of capacity 3HP to 10 HP.
Dismantling the submersible pumping set bowl assembly of any make and model for carrying out repair and replacement of worn out parts by strip opening with all parts such as bowl casing, impellers, pump shafts, lock collects, bushes neck rings etc and machine work such as welding, turning, re-facing where required and replacing of parts of pump of 6 to 9 stages, size up to 100 mm, for 6 HP to 10 HP capacity Note:- Spares parts and their fixing shall be paid separately under the respective items of this schedule.
S&F in replacement of pump shaft stainless steel suitable for submersible pump set up to 9 stages including threading cutting to size all as specified and directed by Engr-in-charge.
S&F in replacement of gun metal impellers suitable size for bowl assembly of submersible pumping set as per site requirement for suction discharge and intermediate bowls complete all as specified and directed by Engr-in-charge.
S&F CI casing suction/discharge/intermediate with studs.
S&F shaft seal of rubber all as specified.
S&F neck of bowls suction/discharge/intermediate.
S&F Gun metal bush of bowls all as specified.
S&F rubber bushes of bowls assembly of suitable size make and model for suction and discharge bowls.
S&F shaft coupling with key stainless steel of suitable sizes type make and model all as specified and directed by Engr-in-charge.
S&F middle /discharge bush, stainless steel of suitable size all as required at site and directed by Engr-in-charge.
S & f stainless steel impeller key all as specified and directed.
S & F studs with nuts all as directed
Mild steel GI column pipe for submersible pump 50 mm dia , heavy duty and 6 meter long duly welded flange/ heavy duty socket on both sides including rubber joint all as directed.
M&L Submersible cable PVC insulated and sheathed 3 core 6 sqmm with copper conductor 1100 volts grade complete all as directed.
M&L for Development (contineously) of Bore well in B block, C block & E Block of depth 110 Mtr to 150 Mtr by means of heavy duty compressor 10 Kg/sqcm (Compressor to be arranged by contractor at his own cost including POL) for first 24 Hrs by lowering suitable dia injector pipes with required size of air line to the required depth for development of well by compressed air till sand free clean water is obtained and testing the yield of borewell for continious running by means of V notch including removal of injector pipes etc complete all as specified and directed.
All as per item No 130 here-in-before but as subsequent development beyond 24 hours or part there of as required as in item No. 130 here in before complete all as specified and directed.
M & L for pouring Pea gravels of size 2mm to 3mm around the liner assembly as per site requirement including continuous watering during development of bore well complete all as specified and directed.
M & L construction of Foundation of tube well of size 0.80 x 0.80 mtr having 45 cm thick PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) including plasterring the outer surface with Cement mortar 1:4 ,10mm thick on fair faces of brick work or concrete surfaces and GI pipe 40mm dia medium grade embedded through out the block of 1.2 mtr length with GI Plug on end for laying cable including demolition of old foundation etc.complete all as specified and directed.
Taking out the water sample from bore well water any type and carry out the test for 17 parameters as per indian standard drinking water specifications (BIS-10500:1991) from Govt approved lab including submission of test results complete all as specified and directed.
S&F in repair 20mm dia High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches with all fittings complete .
S&F in repair Gun metal gate valve with iron wheel head screwed both ends for iron pipe & fixed of size 20mm dia.
Taking out non clog submersible sewage pump set of capacity 12.5 HP to 25 HP from the sewage well and dismentling the motor pump set at site of any capacity and make.
M&L for Strip opening of 12.5 HP to 15HP 3 phase AC Non clog submersible pumpset any type taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including seal PVC (water proof compound) and jointing new submersible cable at least 6m long with water proof tape all as specified and directed and re-assembling the motor and testing complete Note : Quoted Rates shall be deemed to be inclusive of all required T&P and transportation of motor from site to workshop and back to site after necessary repair works.
S&F in replacement of tungstun mechanical shaft seal for sewage pump application as per OEM make.
S&F in replacement of oil seal in non clog submersible sewage motor pump set of any rating as per OEM make .
S&F in replacement of DE roller bearing as per OEM make.
S&Fin replacement of NDE ball bearingas per OEM make.
S&F in Replacement of set of O rings
Reparing of impeller shaft in non clog submersible sewage pump set of any capacity by metal filling, machining, turning and lathe work in wksp complete include testing and ciommissioning.
Supply and filling insulation oil as per OEM .
M&L for Strip opening of 25 HP 3 phase AC Non clog submersible pumpset any type taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including seal PVC (water proof compound) and jointing new submersible cable at least 6m long with water proof tape all as specified and directed and re-assembling the motor and testing compelete of the following rating:- Note : Quoted rates shall be deemed to be inclusive of all required T&P with transportation of motor from site to workshop and back to site after necessary repair works.
S&F in replacement of oil seal in non clog submersible sewage motor pump set of any rating as per OEM make .
S&F In replacement of DE roller bearing as per OEM make.
S&F in replacement of NDE ball bearingas per OEM make.
S&F in replacement of set of O rings
Reparing of impeller shaft in non clog submersible sewage pump set of any capacity by metal filling, machining, turning and lathe work in wksp complete include testing and ciommissioning.
M&L disconnecting of monoblock pump set and motor of capacity upto 0.5HP to 1HP, burnout winding wire, servicing and repairing/ replacement of impeller, shafts, shafts keys, bushes, fan blade, replacement of burnout winding wire with new winding wire of same gauge, cotton tape, varnish, ball bearing, bushes, gland packing, rubber gasket, capacitor, nuts & bolts complete and refixing the same on MS base frame on place and connecting to MS/GI piping line testing and commissioning all as specified and directed. Note: Quoted rate is deemed to be inclusive for opening, transportation to workshop & back after necessary repairing works required such as welding, grinding and chamfering etc.
M&L disconnecting of monoblock pump set and motor of capacity 2 HP, burnout winding wire, servicing and repairing/ replacement of impeller, shafts, shafts keys, bushes, fan blade, replacement of burnout winding wire with new winding wire of same gauge, cotton tape, varnish, ball bearing, bushes, gland packing, rubber gasket, capacitor, nuts & bolts complete and refixing the same on MS base frame on place and connecting to MS/GI piping line testing and commissioning all as specified and directed. Note: Quoted rate is deemed to be inclusive for opening, transportation to workshop & back after necessary repairing works required such as welding, grinding and chamfering etc.
Taking out Monoblock centrifugal electric motor 3 phase 5 HP, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, beaaring, bushes etc of suitable size for following capacity of motor including necessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed by Engr-in-Charge. Note- All T&P required shall be supplied by contractor without any extra cost.
Taking out Monoblock centrifugal electric motor 3 phase 7.5 HP, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, beaaring, bushes etc of suitable size for following capacity of motor includeecessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed by Engr-in-Charge. Note- All T&P required shall be supplied by contractor without any extra cost.
Taking out Monoblock centrifugal electric motor 3 phase 10 HP, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, beaaring, bushes etc of suitable size for following capacity of motor includeecessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed by Engr-in-Charge. Note- All T&P required shall be supplied by contractor without any extra cost.
Taking out Monoblock centrifugal electric motor 3 phase 25 HP, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, beaaring, bushes etc of suitable size for following capacity of motor includeecessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed by Engr-in-Charge. Note- All T&P required shall be supplied by contractor without any extra cost.
Taking out Monoblock centrifugal electric motor 3 phase 40 HP, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, beaaring, bushes etc of suitable size for following capacity of motor includeecessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed by Engr-in-Charge. Note- All T&P required shall be supplied by contractor without any extra cost.
Taking out Monoblock centrifugal electric motor 3 phase 50 HP, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, beaaring, bushes etc of suitable size for following capacity of motor includeecessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed by Engr-in-Charge. Note- All T&P required shall be supplied by contractor without any extra cost.
Dismantling the Monoblock centrifugal Pump assembly any type or make for carrying out repair and replacement of worn out parts by strip opening of all parts such as impellers, pump shafts, lock collers, bearing/ bushes, gland rings , nuts & bolts etc and machine work such as welding turning, re-facing where required and replacing of defective parts up to pump capacity of 100 HP.
Dismantling the Monoblock centrifugal Pump assembly any type or make for carrying out repair and replacement of worn out parts by strip opening of all parts such as impellers, pump shafts, lock collers, bearing/ bushes, gland rings , nuts & bolts etc and machine work such as welding turning, re-facing where required and replacing of defective parts up to pump capacity of 50 HP.
Dismantling the Monoblock centrifugal Pump assembly any type or make for carrying out repair and replacement of worn out parts by strip opening of all parts such as impellers, pump shafts, lock collers, bearing/ bushes, gland rings , nuts & bolts etc and machine work such as welding turning, re-facing where required and replacing of defective parts up to pump capacity of 40 HP.
Dismantling the Monoblock centrifugal Pump assembly any type or make for carrying out repair and replacement of worn out parts by strip opening of all parts such as impellers, pump shafts, lock collers, bearing/ bushes, gland rings , nuts & bolts etc and machine work such as welding turning, re-facing where required and replacing of defective parts up to pump capacity of 15 to 25 HP.
Supply & Fix Rubber Insertion Sheet flange of thickness 4mm where required as per site requdirement, including cutting and making holes of sutable size complete all as specified and directed.
S&F Rubber coupling suitable for up to 25 HP motor including CI outer coupling and nuts & bolts as per existing including machining work for making shaft size complete all as specified and directed
S&F Rubber coupling suitable for 40 HP to 100 HP HP motor including CI outer coupling and nuts & bolts as per existing including machining work for making shaft size complete all as specified and directed
S&F Star coupling including CI nuts & bolts suitable up to 15 HP Motors complete all as specified and directed.
S&F in repair Non returning valve of size 150mm dia for suction complete all as specified and directed.
S&F in repair Non returning valve of size 100mm dia for suction complete all as specified and directed.
S&F in repair Stainer Valve of size 150mm dia for suction complete all as specified and directed including replacement of rubber sheet and nuts & bolts.
S&F in repair Stainer Valve of size 100mm dia for suction complete all as specified and directed including replacement of rubber sheet and nuts & bolts.
S & F Submersible flat cable of size 10 Sqmm 3 core 1100 volt grade cooper conductor conforming to IS 694/1990 with latest ammendments from starter to motor. Make of Cable :- Havells/L&T/Finolex/Plaza
Repairing of existing starter/panel by disconnecting existing burn out cable/ wiring complete and replaced with 1.5 Sqmm single core copper conductor or suitable size as per existing cable include replacement of Digital Volt meter, Digital Amp Meter alongwith CTs, relays, making connection, replacement of cable lugs of suitable size, repair/replacement of locking arrangement including painting with two coat of synthetic enamel paint complete all as specified and directed. Note : Repalcement of contactor, relay, MCCBs will be measured & paid seperately.
Repair to booster pump 1-2 stage of any make & model dismantling and refixing after complete overhauling by replacement of stainless steel shaft keys GM gland intermediate plate with impellers bronze, relays complete all as specified.
Supply and fixing DOL Starter suitable for 3 to 5 HP 440 Volt. Make :L&T/Havells/TC or equivalent.
S&F in repair Star Delta Starter in sheet metal enclosure with contractor & relays complete suitable for 50 HP motor 440 Volt. Make :L&T/Havells/TC or equivalent.
Supply only 3 Pole Power Contactor of 95/100 Amp, 415Volt coil voltage complete all as specified and directed make: L&T MNX 95 or equivalent make in Siemens/C&S
Supply only 3 Pole Power Contactor of 70 Amp, 230 Volt coil voltage complete all as specified and directed make: L&T or equivalent make in Siemens/C&S
Supply only 3 Pole Power Contactor of 32/40 Amp, 230 Volt coil voltage complete all as specified and directed make: L&T or equivalent make in Siemens/C&S
Supply only Contactor ML/MNX or equivalent of 16/25Amps, 415 volts make: L&T or equivalent make in Siemens/C&S
Supply only delay timer relay suitable for starter up to 50HP of L&T make or equivalent make in Siemens/C&S
Supply only single phase preventer to protect motor for phase failure complete all as specified and direced.
S & F Indicator lamp LED type of RYB colour , 230 Volts.
S&F MCCB TP NL LT 415 volt 50 Hz, AC 125 amps 25 KA with thermal magnetic release for OL & SC protection Make : Siemens 3VL / Schneider NSX / Legrand DPX3 . Make : L&T /Legrand/Seimens
S&F MCCB TP NL LT 415 volt 50 Hz, AC 400 amps 25 KA with thermal magnetic release for OL & SC protection Make : Siemens 3VL / Schneider NSX / Legrand DPX3 . Make : L&T /Legrand/Seimens
S&F MCCB TP NL LT 415 volt 50 Hz, AC 250 amps 25 KA with thermal magnetic release for OL & SC protection Make : Siemens 3VL / Schneider NSX / Legrand DPX3 . Make : L&T /Legrand/Seimens
S & F On load Change over switch 415 Volts front operated fixed in panel board include locking arrangements 4 pole of capacity 125 Amps complete all as specifed and directed. Make : L &T/ Havells/ Standard
Taking down existing 2 to 4 core UG cable disconnect from panel board, proper dressing, replacement of cable lugs of appropriate size and refixing the same in position complete all as specified and directed.
Supply only Thermal Over load relay of rating 10- 40 Amps, 415 Volts, complete all as specified and directed make : L&T/Siemens/ C&S.
Supply only Thermal Over load relay of rating 20- 63 Amps, 415 Volts, complete all as specified and directed make : L&T /Siemens/ C&S.
M&L for replacement of watering pipe of 1 mtr length 8mm dia PVC threaded pipe both end nuts as per sample.
M&L for dismantling of 50HP pump set from foundation and replace the same with vibration plate of suitable size and making good disturbed surface as existing after servicing, greasing of the pump sets by dismantling, unscrewing nut bolt, cleaning, greasing and replacement of unsv bushes, Star coupling of suitable size including machining work complete, gasket, gland packing/water seals, nut bolts of suitable size and re-assembling the same in position and connect to the both end terminal circuit testing and commissioning complete all as specified and directed. (Note:- (a). Arrangement of necessary T&P items required for dismantling and reassembling pump motor set shall be deemend to be included in the quoted rate. (b). Cost of items to be replaced as mentioned above shall be deemed to be included in the quoted rate.)
M&L for dismantling of 15 to 25 HP pump set from foundation and replace the same with vibration plate of suitable size and making good disturbed surface as existing after servicing, greasing of the pump sets by dismantling, unscrewing nut bolt, cleaning, greasing and replacement of unsv bushes, Star coupling of suitable size including machining work complete, gasket, gland packing/water seals, nut bolts of suitable size and re-assembling the same in position and connect to the both end terminal circuit testing and commissioning complete all as specified and directed. (Note:- (a). Arrangement of necessary T&P items required for dismantling and reassembling pump motor set shall be deemend to be included in the quoted rate. (b). Cost of items to be replaced as mentioned above shall be deemend to be included in the quoted rate.)
Taking samples of all three sources like raw water, filterered water and suppllied water from a distant source for chemical and bacteriological testing from PHED and submitting the original report to the department on first week of every month complete all as directed and specified by the Engr-in-Charge.
Taking down flash mixer motor with gear assembly and churnig blades arangement of 1.5 HP, 3 Phase, 440 V by disconnecting from steel shaft & reduction gear arrangement. Repairing the motor by replacing the burnt winding, fixing the same after chanign suitable bushes, greasing, oiling, running and testing complete all as specified and directed by Engineer-in-charge.
Taking down agitator motor with gear assembly of 2 HP, 3 Phase, 440 V, with reduction gear and shaft, repairing the motor by replacing bearings, gears, fixing the same, after oiling, greasing complete, running, testing complete all as specified and directed by Engineer -in-Charge.
Taking down flocculator motor with gear assembly and rail for rotating complete of 1 HP, 3 Phase, 440 V, with reduction gear and shaft, repairing the motor by replacing bearings, gears, fixing the same, after oiling, greasing complete, running, testing complete all as specified and directed by Engineer -in-Charge.
Material and labour PCC 1:3:6 type C-2, (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete including dismantling of existing concrete complete all as specified and directed.
M&L for taking out existing filter media from Iron removal plant of any description carefully and removing to distance of 50 Mtrs from pump house, including cleaning, washing inside of filter including painting Inside & Outside, replacement of UNSV PVC threaded hose pipe, rubber washers, Nuts & Bolts , testing and comissioning complete all as specified and directed.
Supply and leveling gravel of size 20 x 12mm thickness as per OEM design complete all as specified and directed.
Supply and leveling gravel of size 12 x 6mm thickness as per OEM design complete all as specified and directed.
Supply and leveling gravel of size 6 x 3mm thickness as per OEM design complete all as specified and directed.
Supply and leveling gravel of size 3 x 1.5mm thickness as per OEM design complete all as specified and directed.
Supply and leveling Ferrimenix (MNO2) compound as per OEM design complete all as specified and directed.
Suppply and leveling Activated carbon (Anthratic coal) as per OEM design complete all as specified and directed.
Supply and leveling fine sand of size 0.45mm to 1mm as per OEM design complete all as specified and directed.
Taking out the sewage water sample from Raw sewage water/Treated sewage water from STP and carry out the test for 12 parameters as per indian standard specifications (IS-3025 (Part- 1, 17, 16, 58, 44, 35, 39, 34, 31) & (IS- 1622) from Govt approved lab or NABL accreded lab complete all as specified and directed.
Goswami Traders
SHANKAR ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .