Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC | ₹13.2 L | L1 | Accepted-AOC Accepted being lowest on 24 Jul 2020 |
| 2 | L2₹15.4 L+₹2.2 L (16.9%)Rejected-Finance SUMEL BAMANWAS SWAI MADHOPUR | ₹15.4 L+₹2.2 L (16.9%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹15.6 L+₹2.5 L (18.8%)Rejected-Finance C O OPPOSITE BDO OFFICE MANDA AKHNOOR DISTT JAMMU PIN 181201 | JAMMU | JAMMU AND KASHMIR | 181201 | ₹15.6 L+₹2.5 L (18.8%) | L3 | Rejected-Finance Rejected |
| 4 | L4₹16.4 L+₹3.2 L (24.4%)Rejected-Finance H NO 273 VPO SURHERA WEST DELHI 110043 | WEST DELHI | DELHI | 110043 | ₹16.4 L+₹3.2 L (24.4%) | L4 | Rejected-Finance Rejected |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
1 Jul 2020, 6:00 pmClosed
GE Faridkot
GE Faridkot-151203 Punjab
Maint of Internal electrification works for OTM Accn under GE Faridkot Mil Stn
2020_MES_349340_1
GE FRD-23/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Faridkot Mil Stn
Class E Category b i
8 documents required · 8 mandatory
₹500
GE Faridkot
₹50,000
Yes
28 Aug 2020
3 Jun 2020
3 Jul 2020
3 Jun 2020
1 Jul 2020
17 Jun 2020
Amount
Taking down carefully existing aluminium/copper point wiring light, fan socket or power bell complete with fitting such as switches, sockets, ceiling roses, pendants batten holders regulators socket, call bells and making good to the disturbed surfaces of walls, matching the colour with existing surface complete all as specified and directed by Engineer in Charge.
Taking down unserviceable main switches and MCB distribution boards single phase complete all as specified and directed by Engineer in Charge.
Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 1.5 Sqmm single core including PVC rigid concealed conduit medium grade of suitable size (not less than 20mm dia) with all accessories such as bend reducers /MS hooks, MS junction boxes 2mm thick galvanized steel pressed sunken terminal boxes of suitable sizes for mounting of switches sockets, fan regulators etc covered with 2.8mm thick plastic laminate (Hylem/Anchor) top cover sheet of required colour fixed with brass screws and cup washers, painting terminal boxes inside and outside with one coat of red oxide primer including continuous earth wire of size 1.5 Sqmm PVC strandedcopper conductor unsheathed, insulated stranded (Green colour) connected to common earth point dolly for One light point/call bell point/fan point to be controlled by one number one way PT switch complete all as specified and directed by Engineer in Charge.
All as per item No 3 here in before but switch socket combination 5 Pin 5 Amps 230 Volts point controlled by one switch and wiring with 1.5 Sqmm PVC unsheathed copper conductor cable 1.5 Sqmm PVC insulated earth wire on independent board complete all as specified and directed by Engineer in Charge.
All as per item No 3 here in before but on same board complete all as specified and directed by Engineer in Charge.
All as per item No 3 here in before but one light point controlled by two 2 way swtiches complete all as specified and directed by Engineer in Charge.
All as per item No 3 here in before but for switch socket combination (multi purposes) 6 Pin 15 Amps point to be controlled by one switch & wiring with 2.5 Sqmm PVC- unsheathed copper conductor cable 2.5 Sqmm PVC insulated earth wire on independent board complete all as specified and directed by Engineer in Charge.
S&F in replacement switch piano type single pole one way 5 Amp, 230 Volt AC supply complete all as specified and directed by Engineer in Charge.
S&F in replacement switch piano type single pole two way 5 Amp,230 Volt AC supply complete all as specified and directed by Engineer in Charge.
S&F in replacement bell push flush type 5 Amp, 230 Volt AC supply complete all as specified and directed by Engineer in Charge.
S&F in replacement socket two in one ,3 Pin 5 Amps 230 Volt AC supply complete all as specified and directed by Engineer in Charge.
S&F in replacement switch Piano type single pole one way 15 Amp 230 Volt AC supply on laminated sheet top cover complete all as specified and directed by Engineer in Charge.
S&F in replacment socket Piano type 6 Pin 16 amp, 230 Volt AC supply complete all as specified and directed by Engineer in Charge.
S&F bell "ding dong" AC 230 Volt AC single phase complete all as specified and directed by Engineer in Charge.
S&F in replacement Ceiling rose, three terminals with bakalite 20mm back plate complete all as specified and directed by Engineer in Charge.
S&F in replacment fan regulator electronic 300 watt socket type 5 speed for ceiling fan 1200/1400 mm sweep complete all as specified and directed by Engineer in Charge.
Supply & fixing in replacement fluorescent LED tube light 1x 20 watt (4 feet long) 230 volt, 6500˚K temp, 0.9 Power factor environment friendly, complete all as specified and directed by Engineer in Charge.
M &L in replacement of 1x9 watt LED retrofit type bulk head fitting luminaries die cast aluminium alloy body heat resistant prismatic glass cover,with specially designed gasket, lamp holder etc with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230 V,50HZ complete all as specified and directed by Engineer in Charge.
S & F in replacement and testing compact and decorative energy efficient LED mirror light fitting anti glare diffuser and decorative end cap suitable for 1 x 09/10 watt including LED lamp with driver complete suitable for fixation on wall with body robust, corrosion resistant, superior finish and without any cracks through holes complete all as specified and directed by Engineer in Charge.
S&F in repair LED Street light 25 Watt Luminaries comprising of epoxy powder coated housing,enclosed with glass cover including 40mm dia GI pipe bracket, cable 1.5 Sqmm and fixing arragement etc. complete all as specified and directed by Engineer in Charge. Bajaj Cat Part No.169821BCLST 25 W LED or equavalent of Havells / Philips / Halonix
S&F as in replacement MCB distribution board double Door of sheet metal Single pole and neutral 8 way with 200 amps rated bus bar 240 volts complete all as specified and directed by Engineer in Charge.
S&F in replacement MCB SP&N 240 volt 32 Amp complete all as specified and directed by Engineer in Charge.
S&F in replacement MCB single Pole 240 Volts 6 to 32 Amp complete all as specified and directed by Engineer in Charge.
S & F as in replacement of MCB distribution board double Door of sheet metal TPN 4 way 415 Volts complete with and including MCCB 63 Amps,16KA complete all as specified and directed by Engineer in Charge.
M&L for Sub main wiring with two single core PVC FRLS insulated stranded copper conductor cable of size 10 Sqmm and PVC insulated FRLS-copper wire 10 sqmm for continuous earth wire drawn into existing concealed conduit complete all as specified and directed by Engineer in Charge.
Taking down old unserviceable cable and Supply and laying XLPE insulated stranded and PVC sheathed heavy duty armoured electric cable with stranded aluminium conductor 1100 Volts grade confirming to IS - 7098 (Part-I) cross sectional area 16 Sqmm 4 core including thimbles / lugs with and including passing through pipe along wall, under road crossing / Nallah / under floor etc complete all as specified and directed by Engineer in Charge. (Note : Earth work, sand cushioning, GI pipe protection and brick protection to be measured and paid seperately).
Supply and laying well burnt clay brick old size sub class 'B' laid dry flat for protection over the cable, width equal to the length of the cable complete all as specified and directed by Engineer in Charge.
M & L for sand cushioning, with dry and clean river sand for under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying and punned to 18cm after laying of the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
S&F steel tubes 40 mm bore light grade galvanised for cable protection fixed to pole / laid under floor / under road crossing etc complete all as specified and directed by Engineer in Charge.
Excavation in trenches n.exc 1.5 mtr width & n.exc 1.5 mtr in depth for foundation/pipe lines, cables etc and getting out in soft/loose soil complete all as specified and directed by Engineer in Charge.
Returning filling in including spreading leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer in Charge.
Removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting pointingcomplete all as specified and directed by Engineer in Charge.
M & L for mild steel clamp of size 40mmx3mm for holding GI pipe with pole and wall complete with nut, bolts and washer complete all as specified and directed by Engineer in Charge.
M & L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth of not less than 1.5 mtr below ground level connection to and including 4mm dia (8 SWG) GI earth wire from earth plate to main switch board including necessary GI bolts, nuts, check nuts, washers, thimble etc to the extend 7.5 mtr as earth lead by means of GI bolts & nuts etc, connecting to LT panel wlith provision of charcoal and salt all as per electrical plate No 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade) excavation and earth work returning , filling, ramming and remove of soil to a distance not exc 50 mtr, make good to match with existing surface and testing on completion complete all as specified and directed by Engineer in Charge.
M&L for checking and locating faults of light/power circuits and defective electrical light/ fan/ bell/ socket outlet 5 Amps and 15 Amps for continuous electric supply or broken neutral system, rectify the same, tightening of loose wire/circuit by using the same old wire or by using new wire up to 1.00 metre length and similar petty work complete all as specified and directed by Engineer in Charge. Note : 1. Switches, socket, modular switch/ sockets, fan regulator, long ladder, tube light, ceiling rose, bulk head fittings, security lights, DB SPN 8 way & DB TPN 4 way, MCB SP, MCB SPN, TM junction box, mounted sheet and condensor etc shall be measued and paid separately under respective items. 2. Wire used more than 1 mtr length shall be measured and paid separately under respecitve item of BOQ.
Repair of unserviceable recess mounted LED luminaries (2'x2') 1x36 watt, 240 volts single phase, replacement of unserviceable driver, circuit plate and connected works complete all as specified and directed by Engineer in Charge.
S & F in replacement of modular switch 6 Amp one way, 1 module complete all as specified and directed by Engineer in Charge.
S & F in replacement of modular switch 15 Amp one way, 1 module complete all as specified and directed by Engineer in Charge.
S & F in replacement of modular socket 6 A-2/3 pin combined, 2 module complete all as specified and directed by Engineer in Charge.
S & F in replacement of modular socket 6 A/16A-2/3 pin combined, 2 module complete all as specified and directed by Engineer in Charge.
S & Fin replacement of modular fan regulator step type, 120 wx 2 module complete all as specified and directed by Engineer in Charge.
S&F in replacement MS junction box 2mm thick galvanised steel pressed sunken terminal boxes of suitable size for mounting of switches sockets, fan regulators etc making good to the disturbed surfaces of walls, matching the colour with existing surface complete all as specified & directed by Engineer in Charge.
S&F in replacement of bakelite laminated sheet 3mm thick of size 9" x11'' including cutting of sheet for fixing switch complete all as specified and directed by Engineer in Charge.
S&F bakelite laminated sheet 3mm thick of size 8" x5'' including cutting of sheet for fixing switch complete all as specified and directed by Engineer in Charge.
S&F bakelite laminated sheet 3mm thick of size 5"x5'' including cutting of sheet for fixing switch complete all as specified and directed by Engineer in Charge.
S&F in replacement of condenser 3.15 Mfd AC 240V, complete all as specified & directed by Engineer in Charge.
Supply & fixing in replacement PVC Lamp holder suitable for and including batten fittings with backalite 20mm back plate complete all as specified and directed by Engineer in Charge.
S & Fin replacement of flexible cable 2 core 23/0.0076 copper conductor complete all as specified and directed by Engineer in Charge.. Note :- A Sum of Rs. 78860.00 will be deducted on account of credit for dismantling/ demolished/ taking down material. Please refer detail on srl page No. 21 (Schedule of credit) of Tender Documents.
GS and Co
DEEPAK ENTERPRISES
M/S RAJESH KUMAR and CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .