Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 LAccepted-Finance | L1 | Accepted-Finance 1st Lowest | |
| 2 | L2₹1.3 L+₹4,388 (3.44%)Accepted-Finance | L2 | Accepted-Finance 2nd Lowest | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-Due to non submission of physical document as per NIT condition. Hence Rejected |
Tender Value
₹1.8 L
EMD Value
₹3,638
Closing Date
3 Oct 2022, 10:00 amClosed
EE WSD APWD
EE WSD APWD Port Blair
Providing IEI works and Air Conditioner units for the new Gym Room inside the Campus of DGP Bungalow, DC 2 under AE II, PBSD, APWD, Port Blair. Sw Providing IEI
2022_APWD_7486_1
138/NIT/WSD/2022-23
Open Tender
Electrical Works
Works
20 days
Port Blair
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹3,638
7 Oct 2022
28 Sept 2022
3 Oct 2022
28 Sept 2022
3 Oct 2022
29 Sept 2022
28 Sept 2022 - 3 Oct 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group B
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and laying of 32 mm. medium class PVC conduit, ISI marked along with accessories including bends & couplers direct in ground (40 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
2 x 2.5 sq. mm
6 x 6 sq. mm
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
6 Module (200mmX75mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
a) 5/6 A switch
b) 15/16 A switch
c) 3 pin 5/6 A socket outlet
d) 6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing of 7 W recessed mounted LED downlight CDL/NW/WW with aluminium housing having minimum efficacy of 100 lm/w ( Make: Phillips , Model : Dura Slim, or equivalent) including connection etc. as required..
Supplying and fixing of 24W LED recessed full lit luminaire, CDL/WW of size 2' x 2' with minimum efficacy of 100 lm/w ( Make: Crompton , Model : LCTLRNE-24-FO-CDL/LCTLRNE-24-FO-WW, or equivalent) including connection etc. as required.
Supplying and fixing of 12 W Outdoor Wall Lantern , WW with minimum efficacy of 100 lm/w (Make:-Philips, Model No : 1739193 or equivalent) including connection etc. as required.
Supplying of ceiling fan of 1200mm sweep , BLDC 5 Star without remote (Make: Crompton, Model: Energion Charge or equivalent) of approved colour with maximum power input of 34 Watts.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying & fixing 4 way MCB Enclosure of sheet steel, phosphatised, powder painted MCB DB with Din Rail (in accordance with IS 13032, IS 8623, IEC/BS EN 60433-3) ( Make: Havells, Cat. No. DHDESFP or equivalent).
Supplying and fixing 25 A rating, TPN, 415 V, 10 kA, "C' curve, miniature circuit breaker(Make: Havells or equivalent) suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.
M K ENGINEERING
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .