Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
₹7.5 L
EMD Value
₹14,924
Closing Date
6 Jul 2020, 1:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
A.P Tyagi je
Electrical Division, Bareilly
Comprehensive Maintenance and Operation of Electromechanical Services in Main TE Bldg Moradabad. (Removal of defects on risk and cost basis)
2020_BSNL_567167_1
04/NIT/TED/BLY/2020-2021
Open Tender
Miscellaneous Works
Item Rate
60 days
Moradabad
Please refer Tender documents.
5 documents required · 5 mandatory
₹590
Accounts Officer (Cash) BSNL O/o The GMTD Bareilly
₹14,924
17 Jul 2020
25 Jun 2020
7 Jul 2020
25 Jun 2020
6 Jul 2020
25 Jun 2020
90 days
Sub-Head -I - Co-axial AC plant (4x7TR) Replacement of following component in existing panel/7.0 TR Package A/c i/c dismantling of faulty item, installation of new item, connection testing etc complete as required. (a) Motor Protection Relays (for 3 phase motor) (MPR D2 M/s Minilec)
(b) Condenser Motor single Phase (M/s Marathon / SS make)
c) Condenser Fan Blade (M/s Blowtech / SS make)
(d) Multfuction meter (CONZERV make, Model-EM6436H)
(e) Supplying and Charging/top up of R-22 Refrigerant gas in the existing 7.0 TR Package AC unit etc. complete as required.
Sub-Head - II -WLL Plant (6x7TR) Replacement of faulty compressor of 3.75 TR capacity (KCG-554 HAE / S.S make) hermetically sealed in the existing package AC unit, suitable for operation on 415 V, 50 Hz AC supply i/c making connection, welding, brazing & dismantaling of faulty compressor etc. complete as reqd. (Note-Old compressor shall be property of contractor and quote rates acordingly.)
Providing testing of Leakage by Nitrogen pressure testing in existing one Circuit of 7.0 TR AC Package units i/c holding the pressure for 48 hrs, vacuumization etc i/c checking and repairing of all leak points etc as complete reqd.
Supplying and Charging of R-22 Refrigerant gas in the existing 7.0 TR Package AC unit etc. complete as required.
Replacement of following component in existing panel/7.0 TR Package A/c i/c dismantling of faulty item, installation of new item, connection testing etc complete as required (a) Motor Protection Relays (for 3 phase motor) (MPR D2 M/s Minilec)
(b) Condenser Motor single Phase (M/s Marathon / SS make)
c) Condenser Fan Blade (M/s Blowtech / SS make)
(d) 63 Amp 4 Pole MCB
(e) Rotory handle of MCCB (DH-100)
(f) Single Phasing Preventor (VSP2, 415 Volt, M/s Minilec)
(g) LED type Indication lamps
(h) PLA relay(8Pin 6A/11A)
(i) Overload relay of 25 A rating
(j) Single Phase Preventer Relay (Sz5 type)
(k) Single Phase Preventer Relay (SDz5 type)
Sub-Head -III -OCB Plant(8x7TR) Replacement of faulty compressor of 3.75 TR capacity (KCG-554 HAE / S.S make) hermetically sealed in the existing package AC unit, suitable for operation on 415 V, 50 Hz AC supply i/c making connection, welding, brazing & dismantaling of faulty compressor etc. complete as reqd. (Note-Old compressor shall be property of contractor and quote rates acordingly.)
Providing testing of Leakage by Nitrogen pressure testing in existing one Circuit of 7.0 TR AC Package units i/c holding the pressure for 48 hrs, vacuumization etc i/c checking and repairing of all leak points etc as complete reqd.
Supplying and Charging of R-22 Refrigerant gas in the existing 7.0 TR Package AC unit etc. complete as required.
Replacement of following component in existing panel/7.0 TR Package A/c i/c dismantling of faulty item, installation of new item, connection testing etc complete as required. (a) 0-60 Sec. Timer (M/s L&T & SS make)
(b) Outdoor motor single Phase (M/s Marathon / SS make)
c) Outdoor Fan Blade (M/s Blowtech / SS make)
(d) High Pressure Gauge
(e) Rotary handle for 100 A 3 Pole MCCB (C&S make)
(f) Replacement of faulty Voltmeter(0-500 VAC ) analog type
(g) Replacement of faulty Ampere meter (0-300 A ) analog type
(i) 63 Amp HRC fuse (HF type )
Repairing of AC plant tripping on Fire alarm system i/c checking and testing the existing wiring and replacement of faulty cable/items (if reqd.) etc complete as required
Sub-Head - IV - MV/LT /EMERGENCY PANEL Replacement of following component in existing MV/LT panels i/c dismantling of faulty components, installation of new components, i/c making connection testing etc complete as required (a) 400 A 3Pole MCCB (C& S Model-CSC5S3,50KA)
(b) Rotary handle for 250 A 3 Pole MCCB (C&S make)
c) Rotary handle for 100 A 3 Pole MCCB (C&S make)
(d) LED type Indication lamps
(e) Replacement of faulty Voltmeter(0-500 VAC ) analog type
(f) Replacement of faulty Ampere meter (0-300 A ) analog type
(a) Replacement of heavy duty Capacitor of capacity 25 KVAR in the existing capacitor bank i/c dismantling of faulty capacitor, making connection with suitable size copper conductor cable, testing and minor modification in existing box (if reqd.) etc complete as required ( Box Series: LTBCH, L&T or SS make)
(b) Open Execution Type FN-125 (TPN) S-D-F with suitable fuse link
(a) Replacement of heavy duty Capacitor of capacity 15 KVAR in the existing capacitor bank i/c dismantling of faulty capacitor, making connection with suitable size copper conductor cable, testing and minor modification in existing box (if reqd.) etc complete as required ( Box Series: LTBCH, L&T or SS make)
(b) Open Execution Type FN-32 (TPN) S-D-F with suitable fuse link
c) Capacitor Duty Contactors - Type MO C 15
Replacement of heavy duty Capacitor of capacity 10 KVAR in the existing capacitor bank i/c dismantling of faulty capacitor, making connection with suitable size copper conductor cable, testing and minor modification in existing box (if reqd.) etc complete as required ( Box Series: LTBCH, L&T or SS make)
Open Execution Type FN-32 (TPN) S-D-F with suitable fuse link
Capacitor Duty Contactors - Type MO C 10
Providing dehydration and filteration of transformer oil for 2 x 750 KVA O/D transformer i/c testing of break down voltage of transformer oil etc complete as required.(The testing report for BDV of transformer oil to be submitted )
Supplying and top up of Transformer Oil of suitable grade for topping up etc complete as required.(M/s Savita or SS make)
Providing insulation testing of transformer oil by set procedure with tool & plant etc complete as required.
Replacement of silica gel etc complete as requred.
Replacement faulty temperature meter of TFr-II
Sub-Head -V - E/A Set-II(180 KVA ) Replacement of faulty stop solenoid coil of existing 180 KVA DG set etc complete as required.
Sub-Head - VI - WAC/SAC Replacement of faulty compressor of 2TR capacity in the existing split AC unit suitable for operation on 220 V, 50 Hz i/c welding, brazing, making electric connection etc. complete as reqd. (Note-Old compressor shall be property of contractor and quote rates acordingly.)
Replacement of following faulty/burn out components/cable in the existing A/c units i/c connection, testing etc. complete as required. (a) Condensor motor of Split AC (1.5 TR)
(b) Blower motor of Split AC (1.5 TR)
c) Capacitor for WAC/SAC of (45+6) MFD
d) Capacitor for WAC/SAC of (36+6) MFD
e) Fan Motor of 1.5 TR Window AC unit.
f) Condensor fan of 1.5 TR/2TR split AC units
g) Condensor fan of 1.5 TR Window AC unit.
Supplying and Charging of refrigerant Gas R-22 in the existing split AC units i/c leakage testing by nitrogen gas pressure, vacuumization etc. complete as required.
Sub-Head - VII- AFD System Repairing of existing AFD System i/c replacement of following faulty parts/ components, i/c connection, testing etc complete as reqd. (a) Repairing of faulty Zone Card
(b) Power Supply card
c) Replacement of faulty AC voltmer(0-300 V)
(d) Replacement of faulty DC voltmer(0-36 V)
(e) Replacement of faulty Hooter
(f) Replacement of faulty MCP
(g) Replacement of faulty Heat detectors etc complete as required.
(h) Replacement of faulty ionisation type Smoke detectors etc complete as required.
(i) Replacement of faulty photo Smoke detectors etc complete as required.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .