Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.0 LAccepted-AOC | ₹44.0 L | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹45.8 L+₹1.8 L (4.05%)Rejected-Finance | ₹45.8 L+₹1.8 L (4.05%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹46.4 L+₹2.3 L (5.25%)Rejected-Finance KHAWASNIWAS NEAR POLICE QTRDEORALI GANGTOK SIKKIM | ₹46.4 L+₹2.3 L (5.25%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹46.5 L+₹2.4 L (5.50%)Rejected-Finance | ₹46.5 L+₹2.4 L (5.50%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹46.7 L+₹2.7 L (6.10%)Rejected-Finance | ₹46.7 L+₹2.7 L (6.10%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹42.2 L
EMD Value
₹84,400
Closing Date
1 Mar 2022, 6:00 pmClosed
GE Gangtok
GE Gangtok New Mil Stn Gangtok Sikkim 737102
Special repair to toilet and bathroom and other sanctioned works at New Mil Stn Gangtok
2021_MES_464702_9
8983
Open Tender
Miscellaneous Works
Item Rate
182 days
Gangtok
As per tender documents
9 documents required · 9 mandatory
₹500
GE Gangtok
₹84,400
Yes
11 Mar 2022
16 Feb 2022
3 Mar 2022
16 Feb 2022
1 Mar 2022
17 Feb 2022
Amount
SCHEDULE 'A' (B/R WORKS) Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, complete all as specified and as directed.
Excavating in post holes (or similar holes) each n.exc 0.5 cu.m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm complete all as specified and as directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches n.exc 1.50m wide n.exc 1.50m in depth & getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading levelling watering and well ramming in layers not exceeding 25 cms in depth in soft/loose soils complete all as specified and as directed by the Engr-in-Charge.
Removing excavated materials(soil) from site to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
S&F powder coated GI grid frame work for false ceiling comprising of the following sections for making partitions of 600mm x 600mm size fixed to walls with rawl plugs & screws and hanged to roof with and including 1mm dia GI wire suspender of suitable length and butterfly clips, size of main tee shall be 23mm x 28mm x 0.30mm thick, cross tee shall be 23mm x 28mm x 0.30mm thick and wall angle shall be 20mm x 20mm x 0.30mm thick complete all as specified and as directed.
Suply and fix 4mm thick Non asbestos fibre cement building boards (E- board) of approved texture, for insulation and acoustic purpose of size 595 x 595 mm size fixed with staples on snap grid as in ceiling with and including dusting of surfaces and applying two coats of oil emulsion distemper over a coat of primer including preparation of surfaces complete all as per manufacturers instructions specifed and directed by the Engr-in -Charge.
S&F collapsible steel gates, side hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc. As specified, erected in position and securing runners with holdfasts and brakcets, complete all as specified and as directed.
Cutting opening in cement concrete walls (any description) for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering etc. Complete all as specified and as directed.
M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, krbs not provided for in item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
Taking down cement plaster/terrazo cast in situ of any description on brick or stone walls, including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks, type C1 1:3:6 (using 20mm graded stone aggregate) exc 10cm in width and setting in mortar 1:6, complete all as specified and as directed.
Distmantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removal of dismantled materials/rubbish from site complete all as specified and as directed
Material & labour for non skid coloured ceramic tiles of 7 to 8mm thick ( Square/rectangular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm as in floors etc conforming to IS-13712, grade B-II-(a) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including cement screed bed/bedding layer of 15mm thick in cement mortar (1:6) complete all as specified and as directed.
Materials & labour for coloured glazed ceramic tiles of size (300x200mm/350x250mm/450x350mm) of 7mm thick, as in vertical surfaces such as skirting/dado/riser to steps etc conforming to IS-13712 grade IB-III set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including cement screed bed/backing layer of 10mm thick in cement mortar (1:4) complete all as specified and as directed.
S&F powder coated aluminium frame (minimum thickness of powder coating 50 micron) for doors, partitions etc weight not less than 0.55 Kg/RM with powder coated anodised snap beading joining clips for fixing incl fixing aluminium grill (anodised transparent or dyed to required shade according to IS : 1868 with minium anodised coating of grade AC-15) of approved design/pattern, with approved standard section and fixed to partition/door frame with CP/brass/stainless screws@ 200mm centre to centre including cutting the grill to proper opening size for fixing and operation including handles, roller etc complete all as specified and as directed by Engr-in-Charge.
S&F 5.5mm thick glass pane area exc 0.5 Sqm but n.exc 1 Sqm fixed on aluminium frame work of appropriate section complete all as specified and as directed.
S&F pre-laminated particle board of 12mm thick interior grade, prelaminated both side with decorative choice laminations fixed with aluminium frame work of any section complete all as specified and as directed.
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides and hanging also fastening and fixing conforjming to Fe-410W (Gde E-250) quality B complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer to new or previously un-treated steel surfaces of any description over 10cm in width or girth including preparation of new steel surfaces complete all as specified and as directed.
S&F 100mm long extruded aluminium alloy with galvanised mild steel hinges pin, anodised and fixed complete all as specified and as directed
S&F 150mm aluminium handles, cast type anodised complete all as specified and as directd
Supply and fix 200 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed by the Engr-in-Charge.
S&F 300 mm long aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium complete all as specified and as directed.
M&L for preparation of old plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer applied over 3mm thick super fine Birla or altek wall care putty finish including complete removal of existing treatment complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer applied over 3mm thick super fine Birla or altek wall care putty finish as per manufacturer's instructions complete all as specified and as directed.
Materials and labour for prepration of old plastered wall surfaces including preparation of surfaces complete all as specified and directed by the Engr-in-Charge.
Complete removal of existing treatment from plastered or unplastered surfaces of walls including cleaning with scrapers, any number of coats and any width or girth etc and applying one coat of oil bound distemper complete all as specified and as directed.
M&L preparation of new or previously untreated wooden surfaces of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
M&L applying two coats of weather proof exterior emulsion paint of standard quality and make ,over a coat of white primer including preparation of new wall surfaces complete all as specified and directed.
M&L applying two coats of weather proof exterior emulsion paint of standard quality and make ,over a coat of white primer including preparation of old wall surfaces complete all as specified and directed.
M&L Preparation of newly or previously untreated plastered surfaces of walls and applying two coats of white wash on new surfaces of walls all as specified and directed.
Dismantling old PGI/CGI/Fiber sheeting any gauge, thickness including Nainital. Sikkim or similar pattern roof/facia including ridge etc and keeping serviceable sheets in safe custody for re-use complete all as specified and as directed.
M&L for brickwork with subclass ''B'' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
Supply and fix 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheets of any colour and any pattern as approved having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as in roof complete all as specified and directed by the Engr-in-Charge.
Supply and fix 0.50mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheets of any colour having tensile strength of 550 Mpa as in ridges, valley, eaves, etc fixed with self tapping screws complete all as specified and directed by the Engr-in-Charge
S&F for 1.12mm thick mild steel plain back sheet in hearts, covering to door shutters, covering to door chowkats etc cut to size edges beaded if directed, holes punched, including round headed screws, clouts nails or rivets and fixed to wood or steel members etc with plain 40mm lap joints or welded/riveted seams including bending running up mitred angles stopped ends outlets etc complete all as specified and as directed.
Materials & labour for rendering 15 mm thick in cement mortar (1:4) on fair face of brick or stone masonary of wall surfaces finished surface even and smooth without using extra cement complete all as specified and as directed.
Materials & labour for rendering 15 mm thick in cement mortar (1:6) on fair face of brick or stone masonary of wall surfaces finished surface even and smooth without using extra cement complete all as specified and as directed.
Material & labour for rendering 15 mm thick in cement mortar (1:4) in two layer of 10 mm thick and 5mm thick each with using Water Proofing Compound @ 3% of weight of cement shall be mixed with cement mortar in finishing outer layer only, as per manufacturer instruction, on fair face of brick work or concrete surfaces, finished fair and even with out using extra cement complete all as specified and as directed.
M&L for rendering 20mm thick in cement mortar (1:4) in two layer of 10mm thick each with using WPC shall be mixed with cement mortar in finishing outer layer only as per manufacturer's instruction, on other than fair face of brick/stone masonry (external surfaces) finished surface fair and even without using extra cement complete all as specified and as directed. Note : (WPC shall be measured and paid separately as supply only)
Dismantling Wrought Iron or Mild Steel Work, viz. Mild Steel Flat Iron (Wind Tie) and Similar Work including Mild Steel Bolts, Nuts, etc., complete all as specified and as directed.
S&F rolled section as in main and cross beams, hip and jack rafters, purlins where connected to common rafter and running rails and guides for sliding doors fixed with angle clear or other connecting plates conforing to Fe-410-W(Gde-E-250 quality-A)including one coat of red oxide zinc chrome primer after preparation of surfaces at contractor''s workshop before fabrication complete all as specified and as directed.
S&F framed work such as grills, gratings, etc, with ends of bars shouldered and/or reveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed.
Material & labour for Mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking , bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. complete all as specified & as directed.
Material & labour for Mild steel TMT bars 6mm to 8mm dia cut to length, bent to shape required, including cranking , bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified & as directed.
Taking down chowkats with shutter of any description (without taking down shutter from the frame) n.exc 1.5 Sqm each and removing from site complete all as specified and as directed.
S&F 2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed.
Demolition to cement concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
Material and labour for 75mm thick sand filling under floors including watering and consolidation complete all as specified and directed by the Engr-in-Charge.
M&L Hardcore of gauge not exc. 63mm, deposited, spread and levelled in layers not exc. 15 Cm thick, watered and rammed to a True Surface, complete all as specified and as directed.
S&F Solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying and fixing in opening as per specification and drawing on SI page No.160 of SSR Part-II completed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing on SI page No 156 of SSR Part-II complete all as specified and as directed.
S&F 100mm long mild steel butt hinges, medium weight, cold rolled, complete all as specified and as directed.
S&F 250 mm long aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium complete all as specified and as directed.
S&F 150mm long aluminium anodised handles, cast type, complete all as specified and as directed
S&F 150mm long aluminium anodised tower bolts of extruded section and fixed complete all as specified and as directed.
M&L for 75mm thick PCC (1:3:6), type C-2 (using 40mm graded stone aggregate) as in plinth protection; path / hardstanding etc laid in bays / panels not exc 2.00 sqm each including construction joints at suitable interval and each corner and filled with bituminous mastic filling (1 part bitumen & 3 part sand) and finished the surface even and smooth without using extrs cement complete all as specified and as directed.
M&L PCC 1:3:6 type C2 using 40mm graded stone aggregate as in surface channels/drain including forming fair finished to drain channel complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B-12 (using 20mm graded stone aggregate) as in flooring including finish the surface even and rough to receive the top finish complete all as specified and as directed.
M&L for 25mm thick PCC 1:2:4 type B-12 (using 20mm graded stone aggregate) finished concrete surface even and smooth complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks, type C1 1:3:6 (using 20mm graded stone aggregate) exc 10cm in width and setting in mortar 1:6, complete all as specified and as directed.
M & L walling of random rubble stone masonry uncoursed, well bonded, bedded and solidly hearted built in CM 1: 6 incl brought upto course at interval of every 60cm complete all as specified and as directed.
M&L for lacquer coated coloured chequered cement concrete tiles of size 300x300x25mm thick set, jointed and pointed in neat slurry in floors and steps with grey cement and pigments over and incl 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and as directed.
M&L for PCC 1:3:6 type C-2 as in plum concrete in retaining walls etc including plums of stone boulders (Basalt, trap or any other approved) of size 200 to 300mm complete all as specified and as directed.
Supply only stone boulders (Basalt trap or any other approved) of size 200 to 300 mm complete all as specified and as directed.
M&L RCC (Nominal mix) type B1, 1:2:4 using 20mm graded stone aggr as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed
M&L RCC (Nominal mix) type B1, 1:2:4 using 20mm graded stone aggr as in columns, pillars, piers, post and struts etc complete all as specified and as directed
M & L for RCC (Nominal Mix) (using 20mm graded stone aggregate) as in beams, cantilevers, bressumers, lintel over 1.5 m span complete all as specified and as directed.
M&L for 100mm thick cement concrete 1:3:6 type B-2 (using 20mm graded stone aggregate) as in path/steps laid with and including use and waste of form work and finishing the surface even and rough to receive the topping layer or tiling complete all as specified and as directed.
M&L for 2nd class hardwood in scantling fixed in clean sawn and fixed unframed work etc complete all as specified and as directed.
Material and labour 6 mm thick plywood, 5 ply, grade BWR type BB fixed with nails to timber frame work in Wall/Ceiling complete all as specified and as directed.
M&L for formwork to sides of concrete foundation, footings, bases of columns, raft & raft beams, sides & soffits (if any) of foundation & similar works, vertical of to batter, rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and sanchions for rough finished surface of concrete complete all as specified and as directed.
M&L for formwork to sides and soffit of floor, roof beam, beam haunching, girders, bressummers, lintels, cantiliver shelves including support overhangs etc also plays between floor and beam etc complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and directed.
S&F 150 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall, laid in trenches or in floor with all necessary clamps,bolts, bends, Tee etc complete all as specified and as directed. Make : Prince, Supreme or equivalent approved.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall, laid in trenches or in floor with all necessary clamps,bolts, bends, Tee etc complete all as specified and as directed. Make : Prince, Supreme or equivalent approved.
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed. Make : Prince, Supreme or equivalent approved.
S&F 150 mm bore PVC (SWR) bends any radius complete all as specified and directed.Make : Prince, Supreme or equivalent approved.
S&F PVC (SWR) half round 150mm dia with rounded edges incl all accessories like bend T etc for eaves gutter complete all as specifed and as directed. Make : Prince, Supreme or equivalent approved.
S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall, laid in trenches or in floor with all necessary clamps,bolts, bends, Tee etc complete all as specified and as directed. Make : Prince, Supreme or equivalent approved.
S&F 75mm bore PVC (SWR) bends any radius for PVC(SWR) pipes, fixed to walls or fixed to steel gutter complete all as specified and directed.Make : Prince, Supreme or equivalent approved.
S&F 75mm bore PVC(SWR) junction single, (Singe T) equal or unequal complete all as specified and directed.Make : Prince, Supreme or equivalent approved.
S&F 110 mm bore PVC (SWR) vent cowl fixed in position complete all as specified and directed.
S&F 75mm dia PVC floor trap of outlet, with gratings, including jointing to waste pipe fixed in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) complete all as specified and as directed.
Taking down 15mm dia steel tubing and connections, including cleaning and refixing or removal to store complete all as specified and as directed.
Taking down 20mm dia steel tubing and connections, including cleaning and refixing or removal to store complete all as specified and as directed.
Supply and fix galvanised steel water tubing 15 mm bore , medium grade with all fittings and fixed complete to walls/ceiling or laid in floors complete all as directed.
Supply and fix galvanised steel water tubing 20 mm bore , medium grade with all fittings and fixed complete to walls/ceiling or laid in floors complete all as directed.
Refixing of old 15mm bore steel tubing and connection in new or old position (walls, ceiling and floors etc .) including all fittings complete all as directed.
Refixing of old 20mm bore steel tubing and connection in new or old position (walls, ceiling and floors etc .) including all fittings complete all as directed.
M&L for cutting chases, pinning in, making good to facing where required and pointing in CM 1:3 for concealed water tubing conduit wiring etc and making good, cutting n.exc 10cm girth as in stone or concrete block walls complete all as specified and directed.
Supply & fix in replacement Rotational moulded polyethylene water storage tank, 500 litres capacity, ISI marked multi layer constriction (cylindrical vertical with closed top), hoisted & fixed in position including supply and fixing of 25mm bore Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe of having weight not less than 455 gms including connection complete all as specified and as directed
Supply and fix vitreous china, white colour flat back, wash hand basin of size 55 x 40 x 79cm fixed with brackets, including providing 32 mm bore PVC waste pipe, 32 mm bore CP waste coupling and making all necessary connectrions complete as directed. Make : Cera Model CORNET Cat No 1008 or equivalent approved .
Supply and fix viterous China squatting pan of 'Orissa pattern' of size 580 mm x 440 mm (white) with intergal foot rest 'P' or 'S' trap, front or back inlet, any pattern (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphon ppe etc complete including provision of PCC bedding and connection to trap, and to flushing pipe, antisyphonage pipe etc complete including makin good to floor all as specified and directed by the Engr-in-Charge.Make Cera Cat No. COVY S3010104 or equivalent approved.
Supply and fix 10 litre capacity low level PVC flushing cistern (white), syphonic action type, with inlet, ball valve, float, handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections complete as specifed .Make : Cera Cat No.B1010101 or equivalent approved.
Supply and fix PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed by the Engr-in-Charge. Make : Prayag Cat No 323 or equivalent approved.
Supply & fix bib tap, cast copper alloy, chromium plated fancy type with crutch or butterfly handle, screwed down for 15mm bore GI pipe for brass ferrule complete all as specified and as directed. Make : JAQUAR Code : CON-107 KN or equivalent approved.
Supply and fixed in repairs 15mm bore pillar taps, fancy type with long neck with aerator cast copper alloy with capstan head, chromium plated, screwed down, high pressure with long screwed shanks, fly-nuts, with screwed for GI pipe complete all as specified and as directed. Make : JAQUAR Code CON-CHR-021 KN or equivalent of approved make.
Supply & fix 15mm bore dia angular stop cocks, chromium plated, with wall flange screwed down, screwed from iron pipe or union and complete all as specified and as directed Make: Essco Cat Part No DLX-ESS 526 or equivalent approved.
Supply & fix angular stop cock made of brass chromium plated screwed both ends for iron pipe for 15mm bore complete all as directed by the Engr-in-Charge. Make: Essco Cat Part No DLX-ESS 526 or equivalent.
Supply and fix in repairs CP tubular towel rail 600 mm long with and including chromium plated brass screws complete all as specified& as directed. Make: Jaquar 'Continental Series' Cat No 1111 or equivalent of approved make.
S&F 4mm thick figured glass pin head type and glazing with oil putty including steel pin in square n.exc 0.5 Sqm in each pane fixed to steel frame complete all as specified and as directed.
S&F 25 mm thick Flush door shutter, solid core construction, with block board core and plywood face panels. Commercial type on one side and other face covered with decorative face veneer with lipping / frame to match complete all as specified and as directed.
S&F for steel ventilators with top hung shutter incl hinges, steel peg stay along with 4mm thick figured glass strips, pin head type and glazing with oil putty in squares n.exc 0.50 Sqm in each pane etc complete all as specified and as directed.
SCHEDULE 'A' (E/M WORKS) M&L for point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC (FRLS) insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with multistranded copper conductor in including PVC heavy grade rigid non metallic 25mm PVC casing caping (double Lock) including PVC polycarbonate/PVC/recatangular block/box of suitable size fixed by means of brass machine screw and cap washer including size 1.5 sqmm (nomnal cross sectionl area PVC (FRLS) insulated unsheathed single core multistranded copper conductor cable as earth continuity conductor connected to main switches/DBs or common earth dolly complete all as specified and directed for the following .Make of cable-Havells/Finolex/plaza, Make of casing caping- Prestoplast/Plaza/Modi.
All as per item No. 110 above but with 2.5 Sqmm copper conductor with 2.5 Sqmm earth stranded wire for 16 Amps power point in independed board.
All as per item No. 110 above but for one socket outlet 3 Pin 5 Amps on independent board.
All as per item No. 110 above but for one socket outlet of 15 Amps fixed on independent board with 4 Sqmm multistranded copper conductor wire FRLS PVC insulated and 4 Sqmm copper conductor wire FRLS PVC insulated using as earth wire complete all as specified and as directed.
S&F in repairs switch piano flush button,single pole,one way(ISI marked), 6 amps, 230 volts complete all as specified and as directed. Make : Anchor product code No. 50053 or equivalent of approved make
S&F switch socket combination, 2 and 3 pin, 5/6 amps, multipurpose, flush, non shutter, non inter locking type, 230 volt flush type, white/ivory finish with two fixing hole including suitable gang box complete all as directed including taking down old one. Make : Anchor Product Code No 4056/50483 or equivalent of approved make
S&F switch socket combination, 2 in 1, 6 pin, 5/6 Amps and 15/16 Amps, multipurpose, flush, non shutter, non inter locking type, 230 volt flush type, white/ivory finish with two fixing hole including suitable gang box complete all as specified and as directed.Make : Anchor Cat No. 38808/50665 or equivalent approved.
S&F ceiling rose,PVC/ polycarbonate insulated body, 3 terminal and 240 volts, ISI marked complete all as specified and directed. Make : Anchor Product Code No 39040 or equivalent approved.
S&F sheet metal enclosure DB's 240 volts,IP-43 suitable for mounting MCB's SPN, 8 way with 200 Amps rated copper bus bar double door type complete all as specifed and as directed Havells/ABB/Legrand. Make :L&T Cat No DBSPN008DD or equivalent approved.
S&F sheet metal enclosure DB's 240 volts,IP-43 suitable for mounting MCB's SPN, 4 way with 200 Amps rated copper bus bar double door type complete all as specifed and as directed Havells/ABB/Legrand. Make :L&T Cat No DBSPN004DD or equivalent approved.
S&F sheet metal enclosure DB's 240 volts,IP-43 suitable for mounting MCB's SPN, 12 way with 200 Amps rated copper bus bar double door type complete all as specifed and as directed Havells/ABB/Legrand. Make :L&T Cat No DBSPN0012DD or equivalent approved.
S&F MCB single pole & neutral 40 to 63 amps, 240 volts, 10 KA rapturing capacity, 'C' Curve complete all as specified and as directed. (Make : L&T Cat No. BB20400C to BB20630C or equivalent approved)
S&F MCB single pole 6 to 32 Amps, 240 volts, 10 KA rapturing capacity 'C' Curve complete all as specified and directed by Engr-in-Charge. (Make : L&T cat no BB10060C to BB 10320C or equivalent approved)
S&F in repairs MCB, Triple pole & neutral, 63 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed (Make : L&T cat No BB40630C or equivalent of approved make)
S&F in repairs MCB single pole & neutral 32 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as directed by Engineer-in-charge. (Make : L&T or equivalent of approved make)
Supply and fix lamp holder,angular/straight insulated body with back plate PVC/Polycarbonate type with cord grip cap suitable for batten fittings white/ivory finish and fixing of 20/18 watt CFL. Make : Anchor Product Code No. 39527 or equivalent approved.
S&F LED tube light fittings IP 20,Class I, LED light fitting 1 x 18 W (4 FT), CRI >=80, CT >=5700K, wall/ surface mounted, integrated type, constructed of fire retardant engineering grade extruded plastic & decorative end caps with integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt,power factor >/0.90, operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arrangements complete including 01 No 18 W (4 FT) LED Batten with all accessories internally prewired and including connecting cable of suitable size all as specified and as directed. (Make : REGALBATTEN8UPTO1X22WSSBSWH and Tube light Cat No. TITANIANEO1213T8SSTL18WLED865SPC or equivalent approved).
Supply and fix integrated LED bulk head fittings of 10 watts,pressure die cast housing acrylic diffuser and frame with IP 66 protection complete all as specified and as directed. Make : Havells Cat Part No.HEXAFT10WLED857SSYMBOPC or equivalent approved.
S&F exhaust fan 250mm sweep, 1400 RPM, 240 volts, AC 50 HZ, PVC body, including lovers with and including cutting bricks/stone boulders wall for fixing of fan and finished the cutting surface even and smooth by using cement mortar complete all as specified and as directed. (Make : Havells Ventil Air-DX white or equivalent of Almonard/CG/Bajaj).
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected with galvanised iron/steel earth wire of 4mm dia by means of bolts, nuts, check nuts and washers made outof galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I (2009) and earth wire protected by galvanized pipe light grade 15mm bore and connected to VTPN DB/SPN DB including neccessary earthwork and excavation in any type of soil, GI light grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2;4 type B1 design mix cover slab with 6mm dia MS bars at 100mm c/c both ways with MS hook 6mm dia MS bars etc complete all as specified and as directed including testing on completion.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, inlcuding fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and as directed.
Taking down carefully by unscrewing from boards/outlet boxes, DBs, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators complete all as specified and as directed.
M&L for submain wiring alongwith earth wire of size 2x6.0 Sqmm + 1x6 Sqmm earth wire ISI marked FRLS PVC insulated multi stranded copper conductor single core cable drawn in and incl PVC casing and caping of adequate size with all accessories as required as specified and as directed incl taking down old unserviceable submain wiring. (Note : Three runs of PVC wire with one run of PVC casing and caping will be measured and paid as one length.)
Supply, Laying, jointing & testing 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables conforming to IS 7098(Part-I)-1988, heavy duty with aluminium stranded conductor laid in trenches or passing through pipe of cross sectional area 25 sqmm 2 core with all fixing & connecting accessories complete all as specified & as directed. Note:- (i) Earthwork & Excavation, GI pipe brick protection etc shall be measured and paid separately under relevant items of this schedule. (ii) The rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles/lugs glands, terminal of suitable sizes."
All as per sl item No. 133 here-in above but 16 Sqmm 2 core
Supply and laying DW pipe SN-4 with coupler 50mm OD, ISI marked alongwith all accessories like socket, bend, couplers etc. Conforming to IS 14930, part II complete with fitting and cutting, jointing etc, laid in trenches/fixed to pole/laying under road crossing/fixed on pavement walls with clamps complete all as specified and as directed.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built heating and cooling arrangement and digital inverter twin rotary of capacity 2TR complete all as specified and as directed. Make : Voltas/Lloyd/LG or equivalent approved.
KAMLESH ENTERPRISE
M/S S. S CHETTRI AND SONS
M/S ANIL KUMAR THAKUR
RAAJ BANGAR
BIJAY MITTAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .