Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-AOC DMFT CHORANTANRIYA VIA DUMARTOLA BLOCK MANDU DIST RAMGARH PART A RDSD RAMGARH 07 DMFT 2024 25 GR NO 24 TENDER ID 2024 RDSPL 97055 14 | ₹28.7 L Quoted ₹29.5 L | L1 | Accepted-AOC The lowest tenderer |
| 2 | L2₹29.6 L+₹9,496.40 (0.32%)Rejected-Finance 51 HANUMAN COLONY GALI NO 4 CHAK 5 E CHHOTI SRI GANGANAGAR RAJ | ₹29.6 L+₹9,496.40 (0.32%) | L2 | Rejected-Finance Not the lowest tenderer |
| 3 | L3₹30.5 L+₹91,983.80 (3.11%)Rejected-Finance HOUSE NO 6 18 WARD NO 05 HOUSING BOARD COLONY HANUMANGARH JN 335512 RAJ | HANUMANGARH | RAJASTHAN | 335512 | ₹30.5 L+₹91,983.80 (3.11%) | L3 | Rejected-Finance Not the lowest tenderer |
| 4 | L4₹36.8 L+₹7.3 L (24.7%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | ₹36.8 L+₹7.3 L (24.7%) | L4 | Rejected-Finance Not the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹89,900
Closing Date
13 Sept 2024, 6:00 pmClosed
HQ CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
REPAIR MAINT OF ROOFING PARAPET WALL PLASTERING AND PLUMBING WORKS AT BHAGAT ENCLAVE AT SGNR MIL STN
2024_MES_667258_1
CA NO CWE SGNR T-29 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
GE SRI GANGANAGAR
As per NIT
9 documents required · 9 mandatory
₹500
GE SRI GANGANAGAR
₹89,900
Yes
18 Oct 2024
22 Jul 2024
14 Sept 2024
22 Jul 2024
13 Sept 2024
5 Aug 2024
Amount
Demolition of RCC of any descrition such as chajja, Parapet wall, OHT Tanks. etc and in any position not other wise specially provided for complete all as specified and directed by Engineer in Charge (reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engineer-in-charge.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles.
M&L brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius in cm 1:6 etc.complete all as specified and directed by Engineer - in - Charge.
M&L for reinforced cement concrete type B1, 1:2:4, (using 20 mm graded stone aggregate) as in slab supported on walls, beam and column in floors, roofs, landings, balconies, deck slab and in shelves and etc and setting in mortar complete with joints to match complete all as specified and directed by Engineer - in - Charge.
M&L for form work through finished surface of soffits of suspended slab as roof slabs, floor, landing and similar work not exceeding 200 mm thick complete all as specified and directed by Engineer - in - Charge.
M & L mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed by Engineer - in - Charge.
M&L half brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius in cm 1:6 etc.complete all as specified and directed by Engineer - in - Charge.
Dismantling of brick tiles or terracing tiles single layer on roof including also taking down existing APP membrane & disposal of retrieved material upto a distance n.exc 100m where directed, all as specified.
Demolition of mud in roof, any thickness including plastering and leaping (where full thickness removed or only a part there of disposal off rubbish upto a distance n.exc 100m, where directed.
M&L for cement concerete 1:3:6, type C2 (40 mm graded stone aggregate) as in filling and mass concerete in roof padding etc complete all as specified and dirceted by Engineer-In-Charge.
M & L for cleaning of old Roof wall/ concrete surfaces & applied a coat of cold bituminous primer over cleaned surface @ 0.40 Kg/Sqm followed by APP modified five layer ploymeric membrane 3mm thick, minimum wt 3.00 kg/Sqm reinforced with polyester non-woven fabric (weighing not less than 150gms/Sqm), laid as per the manufactures instruction with side over lap of 75mm & end over lap of 100mm & tucked into the chases on vertical surfaces if required complete all as specified and directed.
M & L 40mm thick brick tiles bedded in 15 mm thick cement mortar (1:6) and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement and pointed with cement mortar (1:1 ) complete all as specified and directed by Engineer- in- charge.
M&L Cement concrete tiles 25cm x 25xcm x 20 to 22 mm thick,with gray cement and no pigment machine pressed; set, jointed and pointed in neat cement slurry over and including 15 mm thick scereed in CM (1:6) with and including liquid water proofing compound as per manufactures specifications, as in roof and floor tiles complete all as specified and directed.
M&L PCC, 1:2:4, type B1 using 20 mm graded stone aggregate as in roof kerbs / benching / coved fillets etc rounded or chamfered on edges, complete, all as directed.
Carefully chipping, removing existing loose/ damaged concrete with plaster from Columns by low impact high frequency hammer/ chipper without damaging the existing sound concrete and exposing old reinforcement upto 10mm beyond corroded reinforcement bars using electrically operated diamond concrete saw blade making the edges straight and even and cleaning it by wire brush and then by air blower and removing/disposal of rubbish outside MoD land complete all as specified and as directed. (Hard concrete should not be removed by force). Height upto and including 4th floor complete all as specified and as directed by Engineer-in-charge
M&L for drilling Holes of 12mm dia up to 100 mm deep holes in structural members at the interval of 300 mm in staggered manner or along the crack line in Reinforced Cement Concrete (RCC) structural element/ brickwork including cleaning of the holes by air blower and inserting 12mm dia NRV (Non Returnable Valve) nozzle compatible with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix inside the hole by applying thixotropic epoxy adhesive to ensure complete sealing and allow curing the system for minimum of 8 Hrs before Grouting including nozzle projections, excess putty, if any, over concrete element by grinding, leveling and finishing the external surface, after completion of the work, etc. complete all as specified and as directed by Engineer-in-charge.
M&L for Grouting, injecting two part, low viscosity, moisture insensitive injection liquid, based on high strength epoxy resin by pressure and using pressure epoxy injector with accessories till nozzle refused to accept the grout including mixing of grout having following properties:- (i) Mixed Density 1.1 kg/l (at +27°C); Viscosity ~ 250 mPas at +30°C and should comply according to ASTM C 881, Type II and IV, Grade-1, Class E+F. (ii) Compressive strength >= 70 N/sqmm (7 days) according to ASTM C 579; Tensile Strength ~ 50 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); Tensile Modulus ~ 2000 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638). (iii) Bond Strength ~ 10.8 N/sqmm (failure in concrete) after 14 days at +30°C cure; Flexural strength ~ 50 N/sqmm according to ISO 178. (iv) Seal the nozzle with thixotropic epoxy adhesive after the refusal of grout material from the nozzle. Note:- leakage through other nozzle or cracks are required to be monitored while grouting and such points to be sealed as and when required without any extra cost complete all as specified and as directed by Engineer-in-charge.Height upto and including 4th floor complete all as specified. Note :- Mode of measurement: per kg of material consumed. Make: SIKA/ Fosroc/ Pidilite or Techno Commercial or equivalent make.
Shotcreting average thickness 25mm in RCC columns, beams and slab etc. (with mix minimum cement content of 350 Kg per Cum, M-25). Concrete having the specified minimum characteristic compressive strength (with ordinary portland cement, coarse sand and graded stone aggregates of 6mm to 10mm size in proportion as per design criteria) incl the cost of centering and shuttering at edges and corner etc as directed by Engr-in-Charge incl chipping of unsound/week concrete material 25mm average thickness from slabs, beams/columns etc with mannual Chisel or standard power driven percussion type all of approved makes incl tapering of all edges, making square shoulder of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and throughly washing with water and allowing it to dry etc incl removel of rust by applying approved rust remover chemical and the coating with Dr Fixit Epoxy zinc primer @ 6 Sqm per Litre at DFT of 100 micron as per manufacturer's instruction and specification, including removing rubbish material from building and thrown in low lying empty area at any distance from the site as directed complete as specified and as directed by Engineer-in-Charge. Make :- SIKA/ Fosroc/ Pidilite or Techno Commercial or equivalent make. Note : Complete treatment to be executed by approved applicator.
Supply and fixing hard drawn steel wire fabric not exc 4kg/sqm cut to lengths, wire mesh to be fixed and firmly anchored to the concrete surface by means of 'L' shaped mild steel shear key welded with existing reinforcement including cost of material, labour, tools and plants incl welding/L-clip/tying with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair face of brick work of walls, mixed with water proofing compound (ISI marked) @ 3% by weight of cement or as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified. Note : Water proofing compound shall be measured and paid for separately.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified nad directed by engineer in charge.
M&L for complete removal of existing treatment & washing the surface with pressure water on old external/ internal wall surface complete all as specified and directed by Engineer- in- charge.
M&L for applying two coats of wall care putty on wall suface as per application (a) Applying one coat 1.5 mm thick wall putty on cleaned surface after that grind the surface and clean the surface with broom and prepare the surface for second coat. (b) Applying 2nd coat of 1.5 mm putty complete all as specified and directed by Engineer- in- charge.
M&L for applying one coat of primer on prepared surface wall using roller complete all as specified and directed by Engineer- in- charge.
M & L for applying Two coats of 100% Premium acrylic emulsion exterior paint Apex Advcanced Dust Proof Emulsion using roller surfaces complete all as specified and directed by engineer in charge.
Taking up or down GI tubing 15 mm bore pipe including cleaning for re-fixing or removal to store omplete all as specified and directed.
All as per Ser item No 27.00 above but refixing 15 mm dia ,old steel tubing and connections in new or old position (wall, ceiling and floors etc) complete all as specified and directed.
S&F GI tubing 15 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors, complete all as specified and directed.
Taking up or down GI tubing 20 mm bore pipe including cleaning for re-fixing or removal to store complete all as specified and directed.
All as per Ser item No 30.00 above but refixing 20 mm dia ,old steel tubing and connections in new or old position (wall, ceiling and floors etc) omplete all as specified and directed.
S&F GI tubing 20 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors, complete all as specified.
Taking up or down GI tubing 25 mm bore pipe including cleaning for re-fixing or removal to store complete all as specified and directed..
All as per Ser item No 33.00 above but refixing 25 mm dia ,old steel tubing and connections in new or old position (wall, ceiling and floors etc) complete all as specified and directed.
Dismantling PVC water tanks and removing for capacity exceedin 250 litres & not exceeding 500 litres etc., complete all as specified and directed
Dismantling of water tanks of capacity exc 500 Ltr & n.exc 1000 Ltr and removing from site complete all as specified and directed.
S&F 1000 Litre capacity Rotational moulded polyethylene water storage tanks (cylindrical, vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including 20 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete, all as specified and directed.
S&F 500 Litre capacity Rotational moulded polyethylene water storage tanks (cylindrical, vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including 20 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete, all as specified and directed.
S&F gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20 mm bore complete all as specified and directed.
Disconnecting existing tanks of capacity exceedin 250 litres & not exceeding 500 litres etc, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. complete all as specified and directed by Engineer in Charge
Disconnecting existing tanks of capacity exceedin 500 litres & not exceeding 1000 litres etc, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. complete all as specified and directed by Engineer in Charge
Demolition and breaking up or taking down PVC/AC/CI/SSW 100mm bore pipe drain pipes, set in cement mortar including PCC haunching and bedding, complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including PVC holding clamps, complete all as specified and directed.
S&F 110mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed.
Demolition of Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed.
M&L for water proofing treatment to sunken slab and adjjoining vertical surfaces as specified under :- (a) M&L rendering 10 mm thick in cement plaster (1:3) using coarse sand mixed with integral water proofing compound trowel even and smooth with steel trowel on sunken surfaces. (b) Applying first coat of chemical pidifin 2K(Dr Fixit) on cleared RCC surfaces @ 0.86 Kg/Sqm (Minimum) as recommended by manufacturer. (c) Provide a layer glass fibre mesh of size 2.25mm x2.25mm (45 GSM) over first coat of chemical Pidifin 2K as per manufacturers recommendation. (d) Applying second coat of chemical Pidifin 2K (Dr Fixit) @ 0.86 Kg/Sqm (minimum) layer glass fibre mesh of size 2.25mm x 2.25mm (45 GSM) as recommended by manufacturers. Note : WPC shall be measured and paid separately.
Supply only Integral water proofing compound ISI marked confirming to IS 2645 - 2003 complete all as specified and directed by engr in charge.
M&L for PCC 1:5:10, type E-2, using 40mm graded stone aggregate as in filling of sunken floors etc complete all as specified and directed.
M&L 40 mm GI pipe medium grade, made to shape as in spout pipe in sunken/ verandah/ Balcony complete all as specified and directed.
Dismantling and disconnecting existing CI soil waste/vent pipe 100 mm bore fixed to wall, laid in trenches including all fittings & accessories complete all as specified and directed.
Dismantling and disconnecting of existing CI soil waste/vent pipe 75 mm bore fixed to wall,laid in trenches incl all fittings & accessories complete all as specified and directed.
S&F 100mm dia Cast Iron soil waste & vent pipes in any length with or without ears, with cement joints but fixed to walls & fixing with clamps complete all as specified and directed.
S&F 75mm dia Cast Iron soil waste & vent pipes in any length with or without ears, with cement joints but laid in trenches / floors complete all as specified and directed.
S&F in repairs 100 bore, CI bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door complete all as specified and directed.
S&F in repairs 75 bore, CI bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door complete all as specified and directed.
M&L in repairs 75mm dia of long neck CI floor trap with grating including jointing to waste pipe fixed in cement concrete 1:2:4, type B1, complete all as specified and directed.
M&L in repairs branch pieces, 100 mm bore, (equal or unqual), ordinary or inverted (spigot or socket type) or with oval acess door complete all as specified and directed by Engineer-in-Charge.
M&L in repairs branch pieces, 75 mm bore, (equal or unqual), ordinary or inverted (spigot or socket type) or with oval acess door complete all as specified and directed by Engineer-in-Charge.
M&L Bends suitable for 100mm dia CI pipe with duck's foot or heel rest as in repairs complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each as doors, windows & ventilators etc. and removal from site complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm each and removal complete all as specified and directed.
S&F 2nd class HW factory made Plain, framed, panelled shutters 35 mm thick (two panels), with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS:1003 (Part I) Kiln seasoned and chemically pressure treated including 03 Nos SS Hinges, 02 Nos 150 mm long aluminium handle, 02 Nos 200 mm long aluminium tower bolt , 01 No door stopper, 02 Nos Sliding Door bolt complete all as specified and directed by Engineer in charge.
S&F 2nd class hardwood glazed skeleton shutters 35 mm thick open rebated and prepared to receive guage etc but divided into squares, with plain chamfered or rounded, metered and riveted sash bars any numbers including necessary beading used for protect the wire mesh, 03 Nos SS Hinges, 02 Nos 150 mm long aluminium handle, 02 Nos 200 mm long aluminium tower bolt & 01 No door stopper complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly wooden surfaces of any description over 10cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
S&F Solid FRP Door Frame of size 90mm x 45mm with single rebate of 32mm x 15mm to receive shutter moulded with fire retardent grade and saturated polyster resin and choped mat door framed shall be 2 mm thick and fill with suitable block in all the three legs the frame shall be covered with fiber glass all side MS stay shall be provided at the bottam to steady the frame as per specification shown on drawings.
S&F for factory made solid panel FRP door shutter shall be 30mm thick (style) glass fibre reinforced plastic panel door shutter of requred colour with fire retardent grade and saturated polyster resin moulded to 3 mm thick FRP liminated for forming hollow rails and style with wooden frame and suitable block of seasoned wood inside at reqd places for fixing of fittings cast monolithically with 5 mm thick FRP panel and conforming to IS 14856:2000. suppling and fixing in the frame at site as per specification shown on drawings. including necessary SS hinges , 02 Nos of aluminiu m handle & tower bolt complete all as specified nad directed by engineer in charge
S&F Framed work such as grills, gratings coolar stand,Tank Ring etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work confirming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for preparation of Newly steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), terrazo dado/wall tiling and skirting. etc on brick or stone walls etc including racking out joints hacking for key and scrubbing and removing rubbish off the premises complete all as specified and directed.
S&F glazed ceramic coloured tiles 7mm thick 600 x 300mm size in verticle surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade. including 10 mm thick rendering in cement mortar 1:4 as in vertical surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. Note :- Rendering will be done in course sand (Toka sand) only complete all as specified.
M&L for non-skid joint free coloured ceramic tile 7 to 8mm thick area of each tile exceeding 0.11 Sqm bt not exceeding 0.18 Sqm, in floor etc. set & joined in cement slurry and pointed in coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed by Engineer-in-charge.
S&F in repairs white Vitreous china wash down water closet (pedestal pattern) with fixing bolt, Plastic water closet seat cover, white, closed pattern with flat bottom, and cover with aluminised hinging device, brass chromium plated Jet shower with one meter long flexible pipe including all connection complete all as specified and directed.
S&F in repairs vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, 'P' or 'S' trap, including connection to trap and flushing pipe, antisyphonage pipe etc including provision of PCC (1:5:10), type E2, in filling, making good to floor, complete all as specified.
S&F in repairs vitreous china wash hand basin with pedestal, white, bowl of size 510mm x 420mmx 180mm & pedestal long 175mm x 185mm x 715mm including a pair of cast iron brackets embedded in PCC 1:3:6 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified and directed.
S&F in repairs 15mm bore Long body bib tap, cast copper alloy, chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
S&F in repair CP angle valve for 15 mm bore pipe with capstan head long screwed shank including cp cover plate fancy type fixed complete all as specified and directed.
S&F in repair 15mm bore concealed type, stop valve cast copper alloy screwed down high pressure with capstan head and cup, screwed both ends for iron pipe or for union complete all as specified and directed.
S&F central hole wash basin mixer 15mm bore brass without polp up waste with 10mm dia 450mm long copper pipes complete all as specified and directed.
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
S & F in repair PVC low level cistern of 10 ltrs capacity with top push button inclusive of brackets and PVC bend long type and connection to flush pipe of any size and pattern with inlet ball valve float and handle complete all as specified and directed.
S&F Stainless Steel grating 125mm dia with waste hole (Minimium weight 40 grams) complete all as specified and directed.
S&F Stainless Steel grating 100mm dia without hole (Minimium weight 25 grams) complete all as specified and directed.
S&F PVC connection 450 mm long suitable for 15 mm bore GI pipe including CP brass nuts on both sides, complete all as specified and directed.
S&F CP brass soap dish of fancy type, complete all as specified and directed.
S&F glass corner self assembly, fancy type, made of 5 mm thick sheet toughened glass of size 250x250mm, fixed with CP brackets, complete all as specified and directed.
S&F in repairs CP brass towel rack, 20mm dia, ‘D’ type, 60cm long between flanges, fixed to PVC rawl plugs with chromium plated brass screws, complete all as specified and directed.
S&F in repairs cromiam plated shower rose of 200 mm size Square/round with swivel joint including fixing with long shower arm of size 600mm long to steel pipe of 15mm bore or union complete all as specified and directed.
S&F in repairs cabinet of PTMT with looking mirror of size 350x555mm complete all as specified and directed by Engineer-in-charge.
M& L for providing and fixing stainless steel (Grade 304) railing made of Square hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) & Providing baluster and necessary fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc, of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
SHIVA CONSTRUCTION COMPANY (BID ID -3087089)
R B Infrabuilders (BID ID -3085635)
PAREEK AND COMPANY (BID ID -3088262)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .