| 1 | L1₹42.0 LAccepted-AOC 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | ₹42.0 L Quoted ₹42.4 L | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹43.1 L+₹66,443 (1.57%)Rejected-Finance 2 10 PANCHANANTALA ROAD KOLKATA 700 041 | KOLKATA | WEST BENGAL | 700041 | ₹43.1 L+₹66,443 (1.57%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹43.6 L+₹1.2 L (2.83%)Rejected-Finance 53 TOLLYGUNGE CIRCULAR ROAD KOLKATA 700 053 | KOLKATA | WEST BENGAL | 700053 | ₹43.6 L+₹1.2 L (2.83%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹49.2 L+₹6.9 L (16.2%)Rejected-Finance 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA | NORTH WEST DELHI | DELHI | 110035 | ₹49.2 L+₹6.9 L (16.2%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹50.4 L+₹8.1 L (19.0%)Rejected-Finance 1 1 MEREDITH STREET KOLKATA 700072 INDIA | KOLKATA | WEST BENGAL | 700072 | ₹50.4 L+₹8.1 L (19.0%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹39.8 L
EMD Value
₹79,500
Closing Date
17 Nov 2020, 6:00 pmClosed
GE (FW) Kolkata
D9 COMMISSARIAT ROAD HASTINGS KOLKATA 700 022
REPAIR/MAINTENANCE OF FIRE FIGHTING SYSTEM, FIRE ALARM AND COMPUTER MONITORING SYSTEM AT FORT WILLIAM UNDER GE (FW) KOLKATA
2020_MES_388172_1
GE(FW)/8688/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Fort William Kolkata
Refer tender documents
6 documents required · 6 mandatory
₹500
Yes
GE (FW) Kolkata
₹79,500
Yes
3 Feb 2021
20 Oct 2020
19 Nov 2020
20 Oct 2020
17 Nov 2020
3 Nov 2020
Amount
Supply and fix in repair of fire alarm sounders/sirens electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB 500 mtr range suiitable for fire alarm control panel complete all as specified and directed.
Supply and fix in repairs of rubber star coupling suitable for 60 to 90 HP centrifugal pump set
Ditto but for 20 HP pump set
Taking out suction pipe of 200mm bore with defective CI foot valve/stainer of 200 mm dia for replacement of the foot valve (ISI marked) including necessary nut, bolt, washers and cutting threading of GI pipe and lowering in the sump complete all as directed by the Engr-in-Charge.
Dismantling of centrifugal pump set of capacity 60 to 90 HP for servicing of entire pump with replacement of bearing / bush, proper greasing, re-assembling and re-installing the pump set complete in existing positioncomplete all as directed by the Engineer-in-Charge.
Ditto but of capacity 15 to 20 HP
Ditto but Jockey pump of capacity 05 to 10 HP
Dismantling of centrifugal pump set of capacity 60 to 100 HP of make "Kirloskar", electric driven AC 3 phase, 415 Volts, transporting to workshop dismantling, removing the burnt out windings, cleaning the starter slots and rewinding with super enamelled copper wire of suitable gauge, insulating, proper heat varnishing, re-assembling and re-installing the pump set complete in existing position complete all as directed by the Engineer-in-Charge.
Ditto but of capacity 15 to 20 HP
Ditto but Jockey pump of capacity 05 to 10 HP
Supply & fix in repair Power supply card for fire alarm control panel, as directed by the Engr-in-Charge.
Supply & fix in repair Zone card for fire alarm control panel upto 24 zones, as directed by the Engr-in-Charge.
Supply & fix in repair Fire relays, 50 Hz for fire alarm control panel, as directed by the Engr-in-Charge.
Supply & fix in repair Alarm ack/reset card for fire alarm control panel, as directed by the Engr-in-Charge.
Supply & fix in repair Network interface Card(H-NET), as directed by the Engr-in-Charge.
Supply & fix in repair Detectors Complying with and type certified to EN - 45 addressable type smoke detector Photoelectric with optical base with self built intelligence as per IS: 11360 complete all as specified and directed.
Supply & fix in repair Detectors Complying with and type certified to EN - 45 addressable type heat detector with base with rate of rise cum fixed temperature as per IS: 2175 complete all as specified and directed.
Supply & fix in repair remote Response indicator, complete all as specified and directed.
Supply & fix in repair addressable Manual call point, resettable type complete all as specified and directed.
Supply & fix in repair CO-2 release push button, complete all as specified and directed.
Supply & fix in repair sealed maintenance free battery 12 V, 7 AH, DC, complete all as specified and directed.
Supply & fix in repair sprinkler of as per sample suitable for FF Sprinkler system, complete all as specified and directed.
Supply & fix in repair gun metal Hydrant Adaptor, 63 mm dia (ISI marked), complete all as specified and directed.
Supply & fix in repair Lug assembly suitable for 63 mm dia gun metal hydrant valve, as directed by the Engr-in-Charge.
Supply & fix in repair Special Hydrant rubber gasket, suitable for 63 mm dia hydrant valve, as directed by the Engr-in-Charge.
Supply & fix in repair Pressure gauge ranging from 0-14 Kgs (circular type, of 100mm dia), complete all as specified and directed.
Supply & fix in repair Pressure switch, universal type ranging from 0-14 Kg / Sq cm, complete all as specified and directed.
Supply & fix in repair Solenoid coil, suitable for 24 V / 220 V AC / DC, complete all as specified and directed.
Supply & fix in repair CO-2 cylinder valve,for Capacity of (3 Kg to 45 Kg) complete all as specified and directed.
Re-filling of CO-2 gas to existing cylinders of capacity (ranging from 4.5 Kg to 45 Kgs) including necessary testing etc complete all as directed by the Engr-in-Charge.
Supply & fix in repair CO-2 Fire extinguisher valve for wall mounted Fire extinguisher of Capacity (3 to 4.5 Kg), complete all as specified and directed.
Supply & fix in repair Horn with Adaptor, suitable for fire extinguishers, complete all as specified and directed.
Supply & fix in repair DCP Union Cap, suitable for fire extinguishers of capacity (3 to 45 Kgs), complete all as specified and directed.
Refilling of Dry chemical powder, suitable for fire extinguishers, as directed by the Engr-in-Charge.
Refilling of CO-2 gas to existing cartridge of fire extinguishers (ranging from 30 gms to 120 gms), including necessary testing complete, as directed by the Engr-in-Charge.
Supply and fix in repair PVC Hose with nozzle, suitable for fire extinguishers, complete all as specified and directed.
M&L point wiring of detection system network with 2 Core x 1.5 sq mm stranded copper armoured cable alongwith necessary fittings and fixtures, including taking down unserviceable wiring and removing from site complete all as specified and directed.
Hydro-testing charges of CO-2 cylinders of any capacity before re-filling, complete all as specified and directed.
Supply and fix in repair Hydrant cap 65mm dia suitable for hydrant valve, complete all as specified and directed.
Supply & fix in repair gun metal male / female coupling 63mm dia, (ISI marked) suitable for fire hydrant, complete all as specified and directed.
Supply & fix in repair gun metal Hose nozzle 20mm dia, suitable for hydrant line, complete all as specified and directed.
Supply & fix in repair gun metal female adaptor outlet 63mm dia, suitable for fire hydrant, complete all as specified and directed.
Supply & fix in repair 63 mm dia gun metal branch pipe, instantenous inlet,made threaded outlet, 15 mm bore nozzle long suitable for fire hydrant, complete all as specified and directed.
Supply & fix in repair gun metal gland nut, suitable for fire hydrant, complete all as specified and directed.
Supply & fix in repair gun metal double male / female suction hose coupling 63 mm dia (ISI marked), complete all as specified and directed.
Supply & fix in repair 18 SWG thick mild steel hose box of size 800 mm x 600 mm x 250 mm, double door with 4 mm thick glass and door frame made of 16 guage MS sheet painted fire red outside and brilliant white inside yard suitable for 2 numbers 63 mm dia hose and 01 number branch pipe, write the BOX Sl no with as per sample paint complete all as specified and directed.
Supply & fix in repair 63 mm bore 15 metre long fire hose, RRL (Reinforced Rubberised Lined), type "A" marked (conforming to IS-636) with aluminium metal coupling, complete all as specified and directed.
Supply and fix in repair CO-2 filled fire extinguisher of capacity 4.5 Kg, as directed by the Engineer-in-Charge.
Ditto but capacity 2.0 kg all as directed
Supply and fix in repair CO-2 filled fire extinguisher (water type) of capacity 9.0 Litre, complete all as specified and directed.
Supply and fix in repair 100 mm bore galvanized iron pipe (heavy grade) with all fittings (flange/screw type), laid in trenches/fixed complete to wall / ceiling or laid in floor with all fittings complete all as specified and as directed by the Engineer-in-Charge. (Note : Earth work will be measured and paid separately)
Ditto but of size 40 m bore
Ditto but of size 25 m bore
Supply and fix 25 mm bore Gun metal gate valve with iron wheel head, screwed both ends for iron pipes or for unions as directed by the Engineer-in-Charge.
Ditto but of size 40 m bore
Ditto but of size 50 m bore
Cutting existing 40 mm / 50 mm bore steel tubing for alterations or additions, as directed by the Engineer-in-Charge. (Note : Each cut to be measured)
Supply and fix in repair 150 mm bore CI sluice valve of Class PN-1.6, long body type, heavy duty, ISI marked (IS-780 & 5312) flanged end with iron wheel and brass spindle including rubber gasket joints, nuts, bolts etc including testing complete all as directed by the Engineer-in-Charge.
Ditto but of size 50 m bore
Excavation in trenches in soft / loose soil not exceeding 1.5 metre wide for foundation etc or for shafts, wells cesspits, manholes etc not exceeding 10 Sqm on plan and not exceeding 1.5 metre in depth and getting out complete all as specified and directed.
Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated material not exceeding 50 metre and deposited where directed at a level not exceeding 50 metre above the starting point in soil complete all as specified and directed.
Material and labour for PCC type C-2 (by using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete including dismantling of existing concrete complete all as specified and directed.
Demolition of old brick work of any description and Material and labour for brick work using old size sub class ‘B’ bricks, straight or curved on plan exceeding 6 metre mean radius, built in cement mortar 1:6, complete all as specified and directed.
Material and labour for 10 mm thick rendering in cement mortar (1:6) to fair faces of brick or concrete wall surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for complete removal of old painted surfaces of pump set of the following capacities and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (using spray gun) including preparation of surfaces for any description/type with marking of SM/MES No of pumpsets complete all as specified and directed.
60 to 90 HP Electric driven pump set
12.5 to 15 HP electric driven pump set
Material and labour for complete removal of old painted surfaces of steel pipes of the following sizes and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (using spray gun) including preparation of surfaces for any description/type with arrow mark of pipes complete all as specified and as directed by the Engineer-in-Charge.
20 to 25 mm bore pipes
40 to 50 mm bore pipes
80 to 100 mm bore pipes
150 to 200 mm bore pipes
Material and labour for complete removal of old painted surfaces of control valves (any description) of the following sizes and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (using spray gun) including preparation of surfaces for any description/type complete all as specified and as directed by the Engineer-in-Charge.
20 to 25 mm bore
40 to 50 mm bore
80 to 100 mm bore
150 to 200 mm bore
Supply and fix in repairs SS hydrant valve for fire fighting equipment 63 mm bore complete all as specified and directed.
Supply and fix in repairs Device loop Card for fire fighting equipment complete all as specified and directed.
Supply and fix in repair Power Supply Module for fire fighting equipment 63 mm bore complete all as specified and directed.
Supply and fix in repairs Personal Machine Interface Mother Board for fire fighting equipment 63 mm bore complete all as specified and directed.
Supply and fix in repairs Power Terminal Board for fire fighting complete all as specified and directed.
Supply and fix in repairs Control Module for fire fighting complete all as specified and directed.
Material and labour for complete removal of old painted surfaces of mild steel hose box of size 800 mm x 600 mm x 250 mm, double door (any description) and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (fire red outside and brilliant white inside yard) including preparation of surfaces for any description/type complete all as specified and directed.
Supply and fix in repairs of 4 mm thick clear glass for fire hose panel & manual call point incl necessary cutting & fixing screws complete all as specified and directed.
M&L for testing of wet riser system of high rise bldgs (JCOs/ORs/JSA/Signal Regt/New OTM bldg) complete with all connected panel and valves on Monthly basis incl minor repair of panel, gauge and other equipment complete all as specified and directed. (NOTE: Testing of fire fighting system shall be carried out through reputed agency having minimum 05 years experience in fire fighting works. Necessary supporting documents shall be submitted by bidder for approval of Accepting Officer before commencement fo work. All major items mentioned in above schedule will be measured and paid seperately)
M&L for testing of fire fighting system (i.e. alram, sprinkler etc) of high rise bldgs (JCOs/ORs/JSA/Signal Regt/Signal Centre) complete with all connected panel and valves on monthly basis incl minor repair of panel, gauge and other equipment complete all as specified and directed. (NOTE: Testing of fire fighting system shall be carried out through reputed agency having minimum 05 years experience in fire fighting works. Necessary supporting documents shall be submitted by bidder for approval of Accepting Officer before commencement fo work. All major items mentioned in above schedule will be measured and paid seperately)
S&F 200 mm bore CI Butterfly valve, lever operated type, heavy duty, ISI marked (BS-5155), including rubber gasket joints, nuts, bolts etc including testing as in repair complete all as specified and as directed.
S&F flex board of size 18'X12' for machinery / plant details and other sealed matter printed /pasted in on side on 3mm thick acrylic sheet superior quality with necessary fixing arrangement on wall /panel board incl complete printed matter of english version/arrow incl taking down complete all as specified and directed. (Note: Writing matter, colour coding and size of the board shall be provided by dept. The quoted rate shall be deemed to include cost of letters of any size /any type and diagram incl signs if any also)
Repair/maintenance, testing, fault identifications, rectification, trouble shooting, necessary software and firmware upgradation, of existing Fire Alarm Panel alongwith detectors, manual call points, response indicator, hooter and control modules (as per details mentioned here-in-after), installed at at NEW OTM Bldg (Command), including checking, testing, cleaning of all detector, checking termination of installed devices and re-commissioning of the entire fire alarm system complete all as specified and directed:-
New OTM fire fighting installation consists of :- (i) 02 nos Fire Alarm Panel (one in basement and other in first floor area) (ii) 1358 Nos Sprinklers (ii) 587 Detectors (iii) Manual Call Point - 88 Nos (iv) Control Module - 61 Nos (v) Response Indicator - 196 Nos. (vi) Repeater panel, fine garphics work station. (NOTE: The work shall be executed through authorised dearler/ distributor/ partner for "Siemens" fine product line and must have entitled commssioning engineers.
ARATI TRADING CO
S.S.ENTERPRISE
NIRMAL SALES CORPORATION
PODDAR SALES CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .