| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-Finance | L1 | Accepted-Finance lowest bidder | |
| 2 | L2₹5.0 L+₹70,090 (16.4%)Rejected-Finance | L2 | Rejected-Finance bidder is not L1 | |
| 3 | L3₹5.1 L+₹84,816.75 (19.8%)Rejected-Finance | L3 | Rejected-Finance bidder is not L1 |
| Sl No | Description | Qty | Unit | Firemax Safety & Security Pvt.Ltd. L1 | R. S. ENTERPRISE L2 | Swathik Mahajan L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : Cerberus Pro / Honeywell/Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST ) (Approved Make : Esscer) | 155 | Nos | 2,250 ₹3,48,750 Lowest | 2,640 ₹4,09,200 | 2,567.89 ₹3,98,022.95 |
| 2.00 | Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Approved Make : Cerberus Pro / Honeywell/Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST ) (Approved Make : Esscer) | 6 | Nos | 3,500 ₹21,000 | 3,460 ₹20,760 | 376.65 ₹2,259.9 Lowest |
| 3.00 | Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL /ERTL/ LPCB / FM approved) approved. (Approved Make: Cerberus Pro/Honeywell/ Johnson Controls / Edward /Secutron/ Securiton/ Apollo / Morley / Eaton/ GST )(Approved Make : Esscer) | 6 | Nos | 4,500 ₹27,000 Lowest | 5,400 ₹32,400 | 12,567.65 ₹75,405.9 |
| 4.00 | Supply, Installation, Testing & Commissioning of 12 Volt 7AH Lead Acid Battery.(Make: Exide/Amarn Raja/HBL)considering the buy back and 3 years waranty. | 4 | Nos | 950 ₹3,800 Lowest | 1,070 ₹4,280 | 1,257 ₹5,028 |
| 5.00 | Supply, Installation, Testing & Commissioning of 1KVA Online UPS having features-LCD Display: Load %, Battery %, Input/Output Voltage, Frequency, Fault Codes, Communication Ports: USB / RS232, Overload, Short Circuit, Battery Low, Surge, Spike, Auto Restart on Mains Return & Cold Start Function. Including required Batterys and Battery Rack. (Make:-Microtek/APC/AVO/numeric) . | 1 | Nos | 10,000 ₹10,000 | 9,500 ₹9,500 Lowest | 10,900 ₹10,900 |
| 6.00 | Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/Gloster/ RR Kable/Polycab ) through 19 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall. | 150 | Mtr | 120 ₹18,000 Lowest | 150 ₹22,500 | 145 ₹21,750 |
| 7.00Rate should be quoted incl. of all taxes and cess. | ||||||
| 8.00Defect Liability period : 1 year | ||||||
Tender Value
Refer Docs
EMD Value
₹8,575
Closing Date
30 Jun 2026, 2:00 pmClosed
EXECUTIVE ENGINEER-l
OFFICE OF THE EXECUTIVE ENGINEER, P.W.Dte. Central Kolkata Health Electrical Division P-12, C.I.T Road(1st floor) KOLKATA
SITC of multisensor detector, MCP and Hooter for existing fire detection system at Lumbini Park Mental Hospital
2026_WBPWD_5015644_1
WBPWD/EE-l/CKHED/eNIT-18/26-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
20 days
Lumbini Park Mental Hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹8,575
Central Kolkata Health Electrical Division
4 Aug 2026
17 Jun 2026
2 Jul 2026
17 Jun 2026
30 Jun 2026
23 Jun 2026
22 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : Cerberus Pro / Honeywell/Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST ) (Approved Make : Esscer) | 155 | Nos | - | - |
| 2 | Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Approved Make : Cerberus Pro / Honeywell/Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST ) (Approved Make : Esscer) | 6 | Nos | - | - |
| 3 | Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL /ERTL/ LPCB / FM approved) approved. (Approved Make: Cerberus Pro/Honeywell/ Johnson Controls / Edward /Secutron/ Securiton/ Apollo / Morley / Eaton/ GST )(Approved Make : Esscer) | 6 | Nos | - | - |
| 4 | Supply, Installation, Testing & Commissioning of 12 Volt 7AH Lead Acid Battery.(Make: Exide/Amarn Raja/HBL)considering the buy back and 3 years waranty. | 4 | Nos | - | - |
| 5 | Supply, Installation, Testing & Commissioning of 1KVA Online UPS having features-LCD Display: Load %, Battery %, Input/Output Voltage, Frequency, Fault Codes, Communication Ports: USB / RS232, Overload, Short Circuit, Battery Low, Surge, Spike, Auto Restart on Mains Return & Cold Start Function. Including required Batterys and Battery Rack. (Make:-Microtek/APC/AVO/numeric) . | 1 | Nos | - | - |
| 6 | Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/Gloster/ RR Kable/Polycab ) through 19 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall. | 150 | Mtr | - | - |
| 7 | Rate should be quoted incl. of all taxes and cess. | - | - | - | - |
| 8 | Defect Liability period : 1 year | - | - | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.22 MB
Tendernotice_2.pdf
PDF • 0.65 MB
BOQ_5084553.xls
BOQ • 0.23 MB
2911.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .