Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹10.1 L+₹16,661.50 (1.68%)Rejected-Finance HOUSE NO 59 THILIXU VILLAGE BLOCK V PS POST DIMAPUR NAGALAND 797 112 | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹10.3 L+₹43,896 (4.44%)Rejected-Finance C O HILL HARDWARE STORE P R HILL KOHIMA NAGALAND | PHEK | NAGALAND | 797104 | L3 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹19,600
Closing Date
6 Dec 2023, 6:00 pmClosed
AGE (I) ZAKHAMA
C/o 792 FPO PIN-900792 C/O 99 APO
PROVN OF PCC PATHWAY HQ COY TO TRANSIT CAMP COOK HOUSE, SEPTIC TANK NEAR NEW TOILET OF BLDG NO T- 429 AND SPECIAL REPAIR TO BLDG NO- P-14 AT ZAKHAMA MILITARY STATION UNDER AGE(I) ZAKHAMA
2023_MES_627539_1
8214/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) ZAKHAMA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) ZAKHAMA
₹19,600
19 Feb 2024
8 Nov 2023
9 Dec 2023
8 Nov 2023
6 Dec 2023
22 Nov 2023
Amount
Surface excavation n.exc 30 cm deep and averaging 15cm deep in hard/dense soil and getting out complete all as specified and as directed.
Excavation over area, n. exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed.
All as per item serial No 02 here-in-before but depth exc 1.5m and n.exc 3.0m complete all as specified and as directed.
Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation or for shafts, wells cesspits,man holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed. hard/dense soil
Returning, filling, in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and as directed.
Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15 cm thick ( Below or above ground) complete all as specified and directed.
M&L for PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed.
M & L for 25 mm thick PCC 1:2:4, type B0 using (12.5 mm graded stone aggregate) as in floors to receive tiles complete all as specified and as directed.
M & L for APP ased polymeric memrae mimum weighig 3kg/sqm ad miimum 3mm yhick reiforced with polyster o wove faric (wt ot less tha 150 gms/sqm) lad o prited surface y forced applicatio complete all as specified ad directed.
M & L for Priming surfaces and applying heavy treatment (for severe conditions) using glass fibre base bitumen felt, grade 2 complete all as specified ad directed.
M & L for Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified ad directed.
M & L for PCC 1:3:6, type C1 (using 20 mm graded stone aggregate) as in coping, cills, hold fasts, fixing of post, water trough, lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, etc. including necessary formwork (straight or curved) complete all as specified and as directed.
M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed.
M & L for RCC 1:2:4, type B-1 (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc. basement slabs, under-reamed piles and mass concrete etc. complete all as specified and as directed.
M & L for RCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in columns, pillar, piers, posts and struts etc. complete all as specified and as directed.
M&L for RCC type 1:2:4, type B-1 (using 20mm graded stone aggregate) as in Slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc. complete all as specified and as directed. (Note : Reinforement shall be measured and paid separately.
Use and waste formwork to sides and soffits of floor or roof beams, beams haunchings, girders, bressumers, lintels, cantilevers, shelves including supports overhangs etc also splays between floors and beams etc. in rough finished flat surfaces of concrete complete all as specified and as directed.
Use and waste formwork to sides of pillars, posts, struts, piers, columns and stanchions for fair finished flat surfaces of concrete complete all as specified and as directed.
Use and waste formwork to soffits of suspended slab such as roof slabs floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) in rough finished flat surfaces of concrete complete all as specified and as directed.
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cutting, bending cranking, hooking end and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed.
M&L for mild steel TMT bars 8 mm dia and over upto and including 10mm dia cut to length, bent to shape required including cutting, cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and as directed.
M&L for cutting upto a depth of 2.5cm into concrete walls and trimming surface as required, girth exc. 30cm complete all as specified and as directed.
M&L for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed.
M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved in one brick thick honey comb built in cement mortar 1:3 complete all as specified and as directed.
M&L for Loose filling with Broken stone or boulders, aggregates of gaugae 80 t0 150mm in soakge pits, soakage wells complete all as specified and as directed.
Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M & L for rendering 10 mm thick in cement mortar (1:3) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed
M & L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed
M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound (@ 3% by weight of cement or as per manufacture's instructions), finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as "Supply only".
Supply only integral water proofing compound complete all as specified and as directed.
M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
M&L for complete removal of existing treatment of wall and applying two coat of oil bound distemper over one coat of primer complete all as specified and as directed .
M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint over a coat of primer complete all as specified and as directed.
M&L for complete removal of old treated surfaces on walls and applying two coat of cement base paint over a coat of primer complete all as specified and as directed.
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from frame) complete all as specified and directed.
Taking down shutter of any description area n.exc 1 sqm each including builders hardware complete all as specified and as directed.
Taking down shutter of any description area exc 1 sqm but n exc 2 Sqm each including builders hardware complete all as specified and as directed.
M & L for 2nd class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
S & F 2nd Class hard wood framed louvred shutters with stiles and rails 100 to 120 mm wide and panels filled with fixed louvres from 10 to 15 mm thick, supplied and fitted to frames complete all as specified and as directed.
S&F 30mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc with plain, chamfered or rounded, mitred beads (with sash bars) for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (b) complete all as specified and directed.
S & F 100 mm size stainless steel butt hinges, complete all as specified and as directed.
S & F 75 mm size stainless steel butt hinges, complete all as specified and as directed.
S&F 100mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 100 mm long extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed.
M&L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed.
M&L for preparation of old painted surfaces of wood or wood based materials of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
S & F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed.
M & L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces,hold fast etc, complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening conforming to Fe 410-W(Gde-E- 250)quality-A complete all as specified and as directed.
S&F for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290, Gde-E-165 completed all as specified and directed.
S&F mild steel Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors,balusters,nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 etc complete all as specified and as directed.
S & F Steel rolling shutters 1.25 mm thickness of laths , as specified including top cover, and?choring rod, guide channel, hasp and staple and all accessories and one shop coat of primer; erected in position as indicated including safety lever locks steel with 4 lever and ball bearing , complete push pull but gear operated type with chain wheel and hand chain complete all as specified and as directed.
M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed.
M&L for preparation of old painted surfaces of steel and iron work of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
S & F GI tubing 15mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S & F GI tubing 20mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S & F 1000 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
S & F 20mm bore, gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or for union complete all as specified and directed.
S & F 110mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S & F 110 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints and laid in trenches complete all as specified and as directed.
M & L for concrete bed in cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) for drain pipes, 110 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
S&F 110 mm dia PVC (SWR) bends complete all as specified and as directed.
S&F 110 mm dia PVC (SWR) bends with access door complete all as specified and as directed.
S & F 110mm bore PVC ( SWR) junction, single (Single T) with access door equal or unequal complete all as specified and directed.
S&F 110mm dia PVC (SWR) reducer complete all as specifiec and as directed.
S&F 110mm dia PVC (SWR) branch piece, single (Single Y) equal or unequal odinary or inverted (Spigot or Socket type) or with parallel branch complete all as specified and as directed.
S & F 110mm bore PVC (SWR) vent cowl complete all as specified and as directed.
M&L for mild steel flat iron in bands, straps, supports or stays for pintle hinge, hand made sliding bolts, hold fast etc conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in hard dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick, watering, and removing surplus soil to a distance not exceeding 50 M and making good surface complete all as specified and as directed.
Dismantling posts or struts embedded in concrete (wood, steel or R.C.C.) any section, including taking out embedded portion Concrete, brick work masonry, etc.and making good disturbed ground complete all as specified and as directed.
Dismantling fencing wire mesh of any type complete all as specified and as directed.
S&F mild steel angle iron post & strut etc. in fencing including embedding in concrete and screwing etc. including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 GdeE-165 completed all as specified and as directed.
Supply only chain link fencing wire mesh of any size or type, made with 4 mm dia mild steel galvanised wire complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolt etc including provision of binding wire complete all as specified and as directed
S & F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and diameter of shank 5 to 10mm completed all as specified and as directed.
M&L for hardcore with broken stone or boulder of gauge not exc 63 mm, deposited , spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surfaces complete all as specified and as directed.
M&L for pre polished chequered cement concrete tiles in floor, area exc 0.06 Sqm but not exc 0.11 Sqm, 25 mm thick with white cement and pigments of approved make jointed with cement slurry and pointed with white cement mixed with colour pigment to match with the tiles over and including 75 mm thick PCC sub base in (1:3:6) type C2 (using 40mm graded stone aggregate) and screed bed of 15 mm thick in cement mortar (1:6) complete all as specified and as directed.
Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but including switches, ceiling roses, pendants, regulators, sockets, etc. and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed.
M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly) laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with PVC switch board for mounting switches/socket etc for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
All as per item serial No 80 here-in-before but for One 3 pin 5 Amp socket outlet on same board with other switches.
All as per item serial No 80 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board.
All as per item serial No 80 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cable and earth continuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board.
S & F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
S&F socket outlet 3 pin, 2-in-1, 5 Amps, flush type complete all as specified and as directed.
S & F switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
S & F switch socket combination, multipurpose, 2 in 1, 6 pin, 5 & 16 Amp flush type complete all as specified and as directed.
S & F ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed.
S&F in repairs, LED box type fitting pre-wired including LED tube 1x20W connecting up with aluminium housing and sheathed 1100 volt grade flexible copper cable & fix on PVC block complete all as directed. Make:- Jaquar Model-LGLZ01X020XC/ LGLZ01X020XN/LGLZ01X020XW or Havells Model-LUMILINEPLUSBS20WLED865SPCSS or equivalent model of make Philips /GE/Crompton
S&F in repairs LED building security luminaries 20 Watts energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and Impact resistance of IK07 with 10KV Built-in Surge Protection Device including testing on completion complete all as specified and as directed. Make: Havells CAT No. ENDURAPEARLSL20WLED757SASYTOPCMP or equivalent of Philips/Crompton/CG
S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mmthick plastic laminated sheet cover of size 250 mm x 150 mm and 50 mm deep complete all as specified and as directed.
S & F in repairs, single pole & neutral DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed. Make :- Legrand Cat No 5076 11 or equivalent model in Siemens / Schneider
S&F RCBOs, double pole ,30mA , 6 to 32 Amps for earth leakage ,overload & short-circuit protection complete all as specified and directed.
S&F MCBs, SPN 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :- Legrand Model 4086 09 to 17 or equivalent model in Siemens / Schneider/L&T
S&F MCBs, SP 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :- Legrand Model 4085 90 to 95 orequivalent model in Siemens / Schneider/L&T
S&F 1100 volts grade heavy duty flat cable of size 4 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire including taking down old cable of any descrip[tion complete all as specified and as directed.
M&L for GI bracket made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape all as directed, length of GI Pipe shall not be less than 3.0 metre for fixing of light fittings including taking out old bracket complete all as specified and as directed.
S&F exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and as directed. Note: Old exhaust fan will be deposit to MES store.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrode at one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm bore GI pipe medium grade with all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I including dismentling of old earthing complete all as specified and directed.
Shri Atoshe Tuccu
thepfuralie zutso
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .