Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 CrAdmitted-Finance | ₹3.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.1 Cr+₹33.0 L (8.74%)Admitted-Finance | ₹4.1 Cr+₹33.0 L (8.74%) | L2 | Admitted-Finance |
| 3 | L3₹4.4 Cr+₹65.5 L (17.3%)Admitted-Finance NOT SPECIFIED | ₹4.4 Cr+₹65.5 L (17.3%) | L3 | Admitted-Finance |
| 4 | L4₹5.0 Cr+₹1.2 Cr (33.0%)Admitted-Finance VARAD PLOT NO 11 DURGA NAGAR KAMATHWADE NASIK 422010 | NASHIK | MAHARASHTRA | 422010 | ₹5.0 Cr+₹1.2 Cr (33.0%) | L4 | Admitted-Finance |
| 5 | L5₹5.1 Cr+₹1.3 Cr (35.1%)Admitted-Finance | ₹5.1 Cr+₹1.3 Cr (35.1%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | United Sales Corporation L3 | Samruddhi Construction L4 | shah construction L2 | Dinesh Enterprises L7 | SUYOG CONSTRUCTIONS L6 | TAPI PRESTRESSED PRODUCT LTD. L5 | Saiprabha Construction L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| .01BUILDING WORK B/R | ||||||||||
| 1.00 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. | 1,038 | SQUARE METRE | 100 ₹1,03,800 | 21.01 ₹21,808.38 Lowest | 85 ₹88,230 | 30 ₹31,140 | 85 ₹88,230 | 50 ₹51,900 | 39.9 ₹41,416.2 |
| 2.00 | Demolition of cement concrete (un-reinforced) in ground floors and pavings including stone slabs and screed bed not exc 15 cm thickness (below or above ground level) complete all as specified and directed. | 33 | CUBIC METRE | 500 ₹16,500 | 84.05 ₹2,773.65 Lowest | 250 ₹8,250 | 500 ₹16,500 | 325 ₹10,725 | 650 ₹21,450 | 180 ₹5,940 |
| 3.00 | Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar complete all as specified and directed. | 99 | TEN SQUARE METRE | 100 ₹9,900 Lowest | 127.13 ₹12,585.87 | 550 ₹54,450 | 5,000 ₹4,95,000 | 1,000 ₹99,000 | 500 ₹49,500 | 200 ₹19,800 |
| 4.00 | Material and labour for Plain Cement concrete 75 mm thick type C-2 (1:3:6), (using 40mm graded stone aggregate) in sub floors, sub bases, floors & pavings etc complete all as specified and as directed. | 880 | SQUARE METRE | 300 ₹2,64,000 | 232.57 ₹2,04,661.6 Lowest | 330 ₹2,90,400 | 450 ₹3,96,000 | 370 ₹3,25,600 | 400 ₹3,52,000 | 290.7 ₹2,55,816 |
| 5.00 | Material and labour for Plain Cement concrete 25 mm thick type B-0 (1:2:4), (using 12.5mm graded stone aggregate) in sub floors, sub bases, floors & pavings etc complete all as specified and as directed. | 950 | SQUARE METRE | 125 ₹1,18,750 | 127.78 ₹1,21,391 | 110 ₹1,04,500 Lowest | 400 ₹3,80,000 | 600 ₹5,70,000 | 185 ₹1,75,750 | 205.2 ₹1,94,940 |
| 6.00 | Material and labour for machine cut kota stone slab flooring, 20-25mm thick, laid over 20mm thick cement screed base in (1:6) laid and jointed in neat with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed. | 950 | SQUARE METRE | 1,000 ₹9,50,000 | 788.73 ₹7,49,293.5 | 926 ₹8,79,700 | 1,200 ₹11,40,000 | 850 ₹8,07,500 | 950 ₹9,02,500 | 684 ₹6,49,800 Lowest |
| 7.00 | Material and labour for machine cut kota stone slab flooring , 20-25mm thick, in riser of steps, skirting, dado and pillar laid over 15 mm thick cement mortar in (1:4) laid and jointed in neat with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed. | 34 | SQUARE METRE | 1,100 ₹37,400 | 788.73 ₹26,816.82 | 950 ₹32,300 | 1,230 ₹41,820 | 1,060 ₹36,040 | 950 ₹32,300 | 684 ₹23,256 Lowest |
| 8.00 | Material and labour for non-skid,coloured ceramic tiles, 7 to 8mm thick, (square or rectangular or in joint less) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over 15 mm thick screed bed in CM (1:6) complete all as specified and as directred. | 30 | SQUARE METRE | 750 ₹22,500 | 855.71 ₹25,671.3 | 750 ₹22,500 | 900 ₹27,000 | 765 ₹22,950 | 950 ₹28,500 | 684 ₹20,520 Lowest |
| 9.00 | Material and labour for glazed ceramic coloured tiles in vertical surface 450 x 350 x 7mm thick colour and design (as approved) in vertical surface etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile over including 10mm thick backing coat in CM 1:4 complete all as specified and as directred. | 98 | SQUARE METRE | 850 ₹83,300 | 677.48 ₹66,393.04 Lowest | 860 ₹84,280 | 1,000 ₹98,000 | 950 ₹93,100 | 1,000 ₹98,000 | 741 ₹72,618 |
Tender Value
Refer Docs
EMD Value
₹5.3 L
Closing Date
2 Nov 2020, 6:00 pmClosed
CE (AF) Gandhinagar
Lekawada Patia, Chiloda, Gandhinagar 382042
CONSTRUCTION AND IMPROVEMENT OF CERTAIN OPERATIONAL INFRASTRUCTURE AT AF STN PUNE (PHASE-II)
2020_MES_377431_1
83247
Open Tender
Civil Works
Item Rate
450 days
GE (AF) Lohegaon
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹2,000
GE (AF) Lohegaon
₹5.3 L
Yes
3 Nov 2020
14 Sept 2020
3 Nov 2020
14 Sept 2020
2 Nov 2020
19 Oct 2020
19 Sept 2020 - 28 Sept 2020
Amount
BUILDING WORK B/R
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings including stone slabs and screed bed not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar complete all as specified and directed.
Material and labour for Plain Cement concrete 75 mm thick type C-2 (1:3:6), (using 40mm graded stone aggregate) in sub floors, sub bases, floors & pavings etc complete all as specified and as directed.
Material and labour for Plain Cement concrete 25 mm thick type B-0 (1:2:4), (using 12.5mm graded stone aggregate) in sub floors, sub bases, floors & pavings etc complete all as specified and as directed.
Material and labour for machine cut kota stone slab flooring, 20-25mm thick, laid over 20mm thick cement screed base in (1:6) laid and jointed in neat with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed.
Material and labour for machine cut kota stone slab flooring , 20-25mm thick, in riser of steps, skirting, dado and pillar laid over 15 mm thick cement mortar in (1:4) laid and jointed in neat with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed.
Material and labour for non-skid,coloured ceramic tiles, 7 to 8mm thick, (square or rectangular or in joint less) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over 15 mm thick screed bed in CM (1:6) complete all as specified and as directred.
Material and labour for glazed ceramic coloured tiles in vertical surface 450 x 350 x 7mm thick colour and design (as approved) in vertical surface etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile over including 10mm thick backing coat in CM 1:4 complete all as specified and as directred.
Material and labour for vitrified ceramic coloured light shade tiles 10mm thick (square/ rectangular) polished, area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm, laid in floors and dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM (1:6) complete all as specified and as directred.
Material and labour for vitrified ceramic coloured light shade tiles 10mm thick (square/ rectangular) polished, area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm, in skirting, dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick skirting/dado screed bed in CM (1:4) complete all as specified and as directred.
Material & labour for granite (of any type) 20mm thick machine cut in skirting/dado, platforms & cell etc bedding and joint with grey cement slurry and pointed with white cement (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including grinding and polished complete in any design and pattern. complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description and any height not otherwise provided for complete all as specified and directed.
Dismantling of plain or corrugated steel, fiber, polycarbonate or any type of sheeting, any gauge, thickness, including Nainital or similar pattern roof covering etc at any height complete all as specified and directed
Supply & fix galvalume aluminium zinc coating GI based corrugated steel sheet 0.60mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws above 10 m height and apply two coats of synthetic enamel paint on both side of sheets over one coat of zinc primer (Shade of paint shall be in approved camouflaged pattern on one side and plain colour pattern at other side of sheet) etc complete all as specified and directed.
Supply & fix galvalume aluminium zinc coating GI based plain steel sheet 0.60mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws above 10 m height and apply two coats of synthetic enamel paint on both side of sheets over one coat of zinc primer (Shade of paint shall be in approved camouflaged pattern on one side and plain colour pattern at other side of sheet) etc complete all as specified and directed.
Supply & fix in 3.00 mm thick fibre glass reinforced translucent plain or corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc above 10 m height complete all as specified and directed.
Supply & fix in 2.00 mm thick fibre glass reinforced translucent plain or corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc above 10 m height complete all as specified and directed.
Supply & Fixing Wind tie for roof, brackets for vally gutters including securing bolts, posts & struts for fencing including cutting tops to shapes a directed including all necessary drilling, bolting or reveting etc and similar work conforming to Fe-290, Gde-E-165 complete as specified and directed.
Supply and fix rolled section as in main and cross beams, hip and jack rafters purlins where connected to common rafters and running rails and guids for sliding doors, fixed with angle cleats or other connecting plates and similar work conforming to Fe-290, Gde-E-165 complete all as specified and directed
Dismantling wall/floor and ceiling boards (fiber, pulp, insulation etc) or insulation boards/ slabs/blankets, any thickness including covered fillets and supporting members complete all as specified and as directed .
Material & Labour for suspended false ceiling using powder coated anodized aluminium snap grid frame work. Including Hanger 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete and incl 10mm thick 60x60cm size PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S, as per specifications.
Supply & fix plain galvanised mild steel sheeting of 0.80 mm thick in ridges, hips valley gutters, drip and straight flashing (length and girth as fixed) above 10 m height etc complete all as specified and directed
Demolition of brick work, PCC block masonry, stone masonry or boulder masonry, built in cement mortar or cement lime mortar etc complete all as specified and directed.
Taking down cement plaster or screed bedding layer of any description from concrete slab/terrace surfaces etc. including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed
Material & labour for precast cement concrete solid block masonry type C1 (1:3:6) (20mm graded aggregate) with solid blocks, exc 10 cm width and set in CM (1:6) complete all as specified and directed.
Material & labour for rendering 10mm thick on surface of brick work stone masonry or concrete surfaces ,in cement mortar 1:6 finished even and fair without using extra cement complete all as specified and as directed.
Material & labour for rendering 15mm thick on other than fair faces of brick work, stone work or concrete surfaces oof wall in two coats, first coat 5mm thick in cement mortar 1:4 and final coat 10mm thick in cemnt mortar 1:4 finished even & smooth (w/o using extra cement) final coat mixed with WPC as per manufacturer instructions, finished surface even and smooth without using extra cement complete all as directed. (Note :- Water proofing compound (WPC) shall be measured and paid separately).
Material & labour for rendering 5mm thick plastering on concrete surface in ceiling in CM (1:3) and rendering is to be finished even and smooth without using extra cement complete all as specified and directed.
Material & Labour for preparing new surfaces of walls and applying two coats of oil emulsion distemper over a one coat of chalk whiting complete all as specified and directed
Material & Labour preparation of newly plastered surfaces of work and applying two coats of approved pattern campuflage colour cement base paint over a coat of primer all as specified and directed
Material & Labour for preparing on new plastered surfaces of ceiling and applying three coats of white washing on ceiling
Material & Labour for preparing old surfaces of walls and applying one coats of oil emulsion distemper complete all as specified and directed
Material & Labour for preparing old plastered and unplastered surfaces of ceiling and applying one coats of white washing complete all as specified and directed
Material & Labour for complete removal and preparation of old plastered surfaces and applying two coats of approved pattern camoflage colour cement base paint complete all as specified and directed
Material and labour for Plain Cement concrete 40 mm thick type B-0 (1:2:4), (using 12.5mm graded stone aggregate) in sub bases to flooring complete all as specified and as directed.
Supply & fix glass dividing strips 3 mm thick and 38 mm wide complete all as specified and as directed.
Material and labour for Plain Cement concrete 75 mm thick type C-1 (1:3:6), (using 20mm graded stone aggregate) in plinth protection finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for forming contraction (Dummy) joints 75mm deep x 10mm wide for plinth protection & similar work, filled with sealing compound grade 'B' in plinth protection complete all as specified and as directed..
Taking down chowkats or frames but with shutters (without taking off shutter from the frames) not exceeding 1.5 Sqm each complete all as specified and as directed.
Taking down chowkats or frames but with shutters (without taking off shutter from the frames) exceeding 1.5 Sqm and not exceeding 4.0 Sqm each complete all as specified and as directed.
Taking down shutters of any description not exc 1.00 sqm each complete all as specified and as directed.
Taking down shutters of any description exc 1.00 sqm but not exc 2.00 sqm each complete all as specified and as directed.
Supply & fix mild steel work as in bands, straps, supports for stays for rain water hold fasts and similar work confirming to Fe-290 or Gd-E 165 complete all as specified and as directed by the Engr-in-Charge
Material & labour for treating wooden chowkats surface of any description n exc 10cm in width or girth with black bituminus paint in two coats complete all as specified and as directed.
Material & Labour for preparing and treating small articles of builders hardware such as MS hold fasts, MS but hinges etc, with two coats of synthetic enamal paint over a coat of red oxidec primer when un connected with other paintings or when painted in a defferent tint
Material & Lbaour PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in lintles upto 1.5 mtr clear span, cills, steps, bed block for hold fasts, coping and like complete all as specified and as directed by the Engr-in-Charge.
Supply & fix steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
Supply & fix steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel, complete all as specified and directed.
Supply & fix pressed steel frames size 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
Supply & fix pressed steel frames size 105x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
Supply & Fix Solid PVC Door frame of size 50mmx47mm made out of 5mm plain colour PVC Sheet reinforced with MS square tube, supplying & fixing in penning as per specification complete all as specified and directed.
Supply & Fix Factory made solid panel pace door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification complete all as specified and directed.
Supply & Fix 2nd class soft wood plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete (Glass shall be measured Seperately) complete all as specified and directed.
Supply & fix 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
Supply & fix 30 mm thick second class soft wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.24 (a); complete all as specified and directed.
Hacking out old broken glasses (any thickness, size, quality or description) from wooden, aluminium or steel frames or stone, concrete or brick sorrounds, glazed with putty or fixed with any type of beads.complete all as specified and directed.
Material & labour Sheet glass 3mm thick ordinary quality and glazing with aluminium beeds in square not exc 0.5 sq.m in each pane complete all as specified and directed.
Material & labour Sheet glass 3mm thick ordinary quality and glazing with aluminium beeds in square exc 0.5 sq.m in each pane complete all as specified and directed.
Material & Labour Figured glass, pin headed type 5mm thick and glazing with oil putty/ steel beeds in squares not exc 0.5 sq.m in each pane complete all as specified and directed.
Material & Labour Figured glass, pin headed type 5mm thick and glazing with oil putty/ steel beeds in squares exc 0.5 sq.m in each pane complete all as specified and directed.
Supply & fix aluminium handles, cast type, anodised 150mm long complete all as specified and directed.
Supply & fix aluminium, anodised, barrel tower bolts of extruded section and fixed size 150 mm long complete all as specified and directed.
Supply & Fix mild steel butt hinges, medium weight cold rolled100mm size complete all as specified and as directed.
Supply & Fix 100mm butt hinges ,extruded aluminum alloy with galvanized mild steel hinge pin ,anodized and fixed ,type B-21 complete all as specified and directed.
Supply & Fix in repairs aluminum alloy , anodized sliding door bolt with hasp, Staple ( bolt type) and fixing clips of sheet , cast or extruded section and fixing bolts and sliding bolts of extruded section or cast - aluminiumalloy and fixed length of bolt 250mm complete all as specified and directed.
Supply & Fix in repairs floor door stopper of aluminum alloy body overall length of cover plate 150mm and tongue, anodised, with hard drawn steel spring fixed in floor complete all as specified and directed.
Supply & Fix Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks of galvanized wire staples complete all as specified and directed
Supply & Fix in repairs Aluminium (extruded section) body door closure hydraulically regulated designation No 3 universal type suitable floor door shutter of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed
Supply & Fix in repairs glass shelf assembly consisting of 5.50mm thick sheet glass shelf 12mm wide with chromium plated bracket guard and railing 60cm long in repairs complete all as specified and directed
Preparing new or previously untreated wooden surfaces any description exc 10cm width /girth and applying two coats of synthetic enamel paint any shade over a coat of pink primer complete all as specified and directed
Material & labour for preparation of new or previously untreated steel surfaces over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide complete all as specified and directed
Material & labour for preparation of old treated steel surfaces over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed
Dismantling of existing damaged water tank and Supply & Fix Rotational molded polyethylene water storage tank ( cylindrical vertical with close stop) 500 Ltrs capacity ,hosted and fixed in position with all necessary fittings, connector & unon excludng flote valve complete all as specified and directed
Dismantling of existing damaged water tank and Supply & Fix Rotational molded polyethylene water storage tank ( cylindrical vertical with close stop) 1000 Ltrs capacity hosted and fixed in position with all necessary fittings , connector & unon excludng flote valve complete all as specified and directed
Supply & Fix in repairs Ball brass valves high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule fixed in repairs 20mm dia complete all as specified and directed
Taking down steel tubing 15mm and connections, including cleaning for refixing or removal to store complete all as specified and directed
Supply & Fix tubes medium grade galvanized with all fitting and fixed to wall or laid in trenches 15 mm bore complete all as specified and directed
Fixing only tubes medium grade galvanized with all fitting and fixed to wall or laid in trenches 15 mm bore complete all as specified and directed
Taking down steel tubing 20mm and connection including cleaning for refixing or removal to store complete all as specified and directed
Supply & Fix tubes medium grade galvanized with all fitting and fixed to wall or laid in trenches 20 mm bore complete all as specified and directed
Fixing only tubes medium grade galvanized with all fitting and fixed to wall or laid in trenches 20 mm bore complete all as specified and directed
Supply & Fix in repairs Angle stop valves fancy type , cast copper alloy cromium plated, screwed down high pressure with crutch or butter fly handle, fancy type, chromium plated with long shank and cup (concealed type), 15mm bore dia of pipe complete all as specified and directed
Supply & Fix in repairs for Fancy type Pillar taps 15 mm bore, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed
Supply & Fix in repairs Fancy type bib tap cast copper alloy chromium plated butterfly handle screwed down screwed for iron pipe completed (15mm dia tap) complete all as specified and directed
Supply & Fix in repairs Chromium plated shower roses 125mm sizewith or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed
Supply & Fix in repairs Fancy type two way bib tap cast copper alloy chromium plated butterfly handle screwed down screwed for iron pipe completed (15mm dia tap) complete all as specified and directed
Supply & Fix in repair Health faucet (PTMT) with 900mm long flexible tube with wall hook complete all as specified and directed
Supply & Fix in repair grating doom 100mm dia of PTMT (min waight 25 grms) all as directed by the Engr-in-Charge complete all as specified and directed
Supply & Fix in repairs Brass chromium plated tubular Towel Rail 20mm dia, 60cm long including side brackets complete in repairs complete all as specified and directed
Supply & Fix in repairs ColouredToilet paper holder of vitreous china fixed to walls with chromium plated (CP) brass screws complete all as specified and directed
Supply & Fix in repairs 15mm Gun-metal, globe or gate valve ,with Iron wheel head,screwewd both ends for iron pipe and fixed complete all as specified and directed
Supply & Fix in repairs 20mm Gun-metal, globe or gate valve ,with Iron wheel head,screwewd both ends for iron pipe and fixed omplete all as specified and directed
Supply & Fix in repairs vitreous China Wash Basin, white, flat back of size 550 x 400 mm including suitable size of CI brackets, brass chromium plated waste fittings 32 mm dia, PVC connection 15mm size with PTMT nuts of length 300mm. complete all as specified and directed.
Supply & Fix in repairs Vitreous China wash down water closet pan white (excluding flushing cistern) white withPVC (SWR) 'P' trap of bore110/110mm and provision of Lime concrete bedding etc complete including making good to floor omplete all as specified and directed
Supply & Fix EWC seat cover coloured including stainless steel hinges complete all as specified and directed.
Supply & Fix in repairs, 10 litres capacity PVC valveless syphonic action type, flushing cistern (ISI marked), low level with inlet, ball valve, float bracket & flush pipe complete all as specified & directed.
Supply & Fix in repairs S S sinks 1 mm thick kitchen or laboratory (overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm ) with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe and 40mm waste coupling of PTMT minimum weight 60 gms complete all as specified and directed
Supply & Fix in repairs vitreous china urinal ,half stall type ,white (including flushing cistern, flush pipe and waste pipe) wall type complete including providing plugs , bedding urinal against wall in cement mortar 1:2 ,securing urinal to plugs with and including 60mm long brass screws ,Waste coupling of PTMT minimum weight 45 gms ,PTMT urinal Spreader of min weight 60 gms & pointing around urinal back in cement complete all as specified and directed
Material & labour for 32mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly nuts, flange end bedded in red lead cement other end fixed complete all as specified and directed
Supply & Fix in repairs cast iron Nahani trap with grating including jointing to waste pipe fixed to cement concrete type B1 (1:2:4) of 100 mm outlet in repair complete all as specified and directed
Supply & Fix chromium plated connection pipe fancy type 450mm long at size 15mm bore with standard PTMT nut fixed to GI tubing complete all as specified and directed
Demolition and breaking up drain,waste & soil, pipes up to 100 mm internal dia (Salt glazed ware, AC , PVC or renforced concrete ) set in cement concrete ncluding for necessary scaffolding, excavaton, returning filling , removal of soil etc complete all as specified and directed
Demolition and breaking up drain,waste & Soil, pipes 150 mm internal dia (Salt glazed ware, AC , PVC or renforced concrete ) set in cement concrete ncluding for necessary scaffolding,excavaton, returning filling , removal of soil etc complete all as specified and directed
Supply & Fix PVC (SWR ) pipes 150mm single socketed ,in any length with rubber ring joints, fixed to the wall or in floor complete all as specified and directed
Supply & Fix PVC (SWR ) pipes 110mm single socketed ,in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed
Supply & Fix PVC (SWR ) pipes 75mm single socketed ,in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed
Supply & Fix PVC (SWR) bends 110mm dia with access door complete all as specified and directed
Supply & Fix PVC (SWR )branch piece double (single Y ) equal or unequal 110mm bore complete all as specified and directed
Dismantling stone slabs or roof treatment of any description in suspended slabs in roofs,suspended floors, chajjas, landings etc,including cement mortar, bedding (But not backing ) and rubbish of premises complete all as specified and directed .
Material & labour PCC 1:2:4, 25 mm thick type B0 using 12.5mm graded stone aggregate as in floor finished even and fair with out using extra cement complete all as specified and directed
Material & labour for 20 mm thick rendering on fair faces of brick works / Concrete surfaces finished even and smooth without using extra cement in cement mortar 1: 4 complete all as specified and directed
Material & labour for App based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforment with polyster non woven fabric (wt reinforcement not less than 150 gms/sqm) laid on primed surfaced application including preperation and applying two coats of Heat resisting Aluminium paint over APP Membrane complete all as apecified and directed.
Supply only integral waterproofing compound.
Supply & Fix framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders framed balusters walk ways, railing for portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts, etc. for ornamental and intricate design, conforming to Fe290 Gde-E-165 complete all as apecified and directed
Dismantling/Removing Nylon Bird proof Net from its original location ( more than 10 Mtr height above from Ground Level) including removing the supporting bands, straps, ties etc,and keeping in safe place (Contractor is fully responsible for keeping the dismantled Bird proof net in safe custody) to fecilitate Roof sheet replacement, painting of steel sections, electrical works etc complete all as specified and directed including provisioning of line wires, angle clits, standards, rails, straining bolts, etc complete all as apecified and directed. Note:-Quoted rate must include for:- (a) The cost of all the additional items required for removing/dismantling the existing bird proofing net complete all as apecified and directed.
Supply, Fixing & installation bird proofing mesh of polyolefin all weather proof co-polymer of machine knotting wire Bird Control Net of heavy duty having high breaking strength, UV treated of customised length of 1.0mm dia HDPE twine square or fiamond type rope of Mesh size 1" x 1" all as specified and directed. Rope of mesh should be Weather proofing UV stablized and chemically insert, and achieve twine breaking strength of 16 Kgf minimum, and mesh breaking strength of 12 Kgf and knot breaking strength of minimum 23 Kgf minimum per yarn having a melting point more than 250 degree C of any colour as approved by Engr-in-Charge. Hight/ Width of the netting will be at 8 to 12 mtr including hanging and tightening arrangement and to be finished without any undulation all as specified and directed.
Material & Labour for 5 mm thick EPU floor coating system including surface preparation by clearing from dust, muck, moisture & all foreign material and cleaned by mechanical scrubber/ grinder, chemical treatment for oil if required followed by application of primer which shall be a two component, solvent free, epoxy polyamido amine system having a volumetric ratio of mixing of 1 : 1 to yield a thickness of 100 microns then providing and applying the screed layer of minimum thickness of 2800 microns. The self levelling screed shall consist of a low viscous epoxy-amine cured system and graded aggregates (Special Silica). The epoxy system shall have a volumetric ratio of mixing of resin in 2: 1 ratio. The aggregates shall be added on the rate of 1: 3 or 1: 3.5 over that, copper tape, then conductive coat of Aquoxy ESD to be applied to a volumetric ratio of 3:1 to a thickness of 100 microns and finally Epoxy Polyurethane top coat which is a pre-weighed pack ready to mix and use which will consists of resin, hardner, EPI (Colour concentrate) formulated aggregates and carbon fibre. All these 5 parts to be added to agitate the mixture by an electrically driven motor and lay the mixture to the thickness of 2000 microns complete all as specified and directed by Engr-in-Charge and as per manufacturer’s instruction.
Material & Labour for repairing to cracks and potholes by filling with an distant concrete repair compound consisting of a specially developed EPU based Rasin and Hardener which can be used for immediate repairs for worn out floors and pavements, This EPU based Resin ,Hardener and grey colored aggregates to mixed thoroughly with the aid of mechanical stirrer for 5 minutes . Lay the mix with a trowel and level it smoothly , Material to be used for repairing of cracks , potholes and worn out areas should be fast setting ,no water curing higher compressive strength than concrete ,thermally stable and water resistant complete all as apecified and directed
Cutting, racking out existing sealing compound from expansion/ contraction (Dummy) joints of rigid pavement including rackingou tspilled out seailing compound to 25mm wide and 35mm average depth by diamond cutter. Cleaning and preparing the surface, removing the debris to a distance not exceeding 150mtr and depositing where directed and M&L for providing and applying Polyurethane sealant of approved make over a coat of approved primer complete all as specified and directed
Cutting, racking out existing sealing compound from expansion/ contraction (Dummy) joints of rigid pavement including rackingou tspilled out seailing compound to 15mm wide and 20mm average depth by diamond cutter. Cleaning and preparing the surface, removing the debris to a distance not exceeding 150mtr and depositing where directed and M&L for providing and applying Polyurethane sealant of approved make over a coat of approved primer complete all as specified and directed
Material & Labour for providing & applying Polyurethane yellow marking system 100mm wide complete all as specified and directed by Engr-in-Charge/ GE.
Supply & Fix Turbo Ventilator Industrial grade including polycarbonate translucent sheet over Hanger Roof fixed In repair completely above hanger roof as per specification complete all as apecified and directed
Removing Turbo Ventilators with serviceable condition from Hanger Roof to fecilitate replacement of roof sheet and refixing the same over roof with all necessary fittings ,cutting of roof sheet etc completely as per specification.
HANGER DOOR
(v) Existing door paint must be removed/scrubbed down completely and two coat of synthetic enemel paint of approved camoflauge pattern should be applied over a coat of primer all as specified & directed. Providing and fixing of limit switches for auto power cut at suitable fixed destinations of master leaf both in opening and closing situations. (vi) Providing of ldler braking system to be attached with motor gear system via chain sprocket assembly drive, chanical buffers, heavy cleats, conneters, EPDM Gaskets at centre leafs. Auto track cleaners to be fitted at bottom of all leafs. (vii) Providing and fixing of Manual declutching system for any emergency at a suitable height by twisting the mechanism with Handle Shaped LN key. (viii) Rectify alignment of bottom tracks till parking bay to make electric operation smooth and friction free. The bottom track should be straight till parking bay at both extremities. (ix) Rectifying alignment of Top guide channel till parking bay to make electric operation smooth and friction free till parking bay at both extremities. (x) Making all door leaf aligned and straight by taking down door leaf, with all alteration and of small sections all as required.(xi) Hanger door shall be refixed in the same opening after completing repairs etc complete all as specified and directed by Engineer-in - charge.
Dismantling/taking down P-2 Hanger opening (43.5mx8.15m) and a set of 06 doors (7.25mx8.15m) on each opening, in 43.5m opening 6 Equal leafs on each entries bi-parting i.e. 3 leafs each side and quoted rate included all damages made to the existing floor, roof ets shall be made good and match with the existing etc complete all as specified and directed by Engineer-in - charge. Note:- All the works must be carried out as per the specifications mentioned in item No 127 & 127.01 above.
Dismantling/taking down P-745 Hanger opening (43.75mx7.4m) and a set of 08 doors (5.45mx7.40m) on each opening, in 43.75m opening 8 Equal leafs on each entries bi-parting i.e. 4 leafs each side and quoted rate included all damages made to the existing floor, roof ets shall be made good and match with the existing etc complete all as specified and directed by Engineer-in - charge. Note:- All the works must be carried out as per the specifications mentioned in item No 127 & 127.01 above.
Aligning of existing bottom tracks withhanger doors by repair/ replacement of ball bearing/ machining/ complete wheels necessary as required of all top and bottom wheel of same / better specifications. The following components of the Hanger doors shallalso be repaired/ replaced where ever required. (i) repair/ replacement of bottom wheels including Machining as required, by keeping alignments in right direction by removing form door leafs.(ii) Re-assembling of wheels, placing ball bearing, re-fixing on door leafs etc complete all as specified and directed.
Aligning of top existing tracks by repair/ replacement of ball bearing/ machining/ complete wheels necessary as required of all top and bottom wheel of same/ better specifications. The following components of the Hanger doors shall also be repaired/ replaced where ever required. (i) Repair /replacement of top wheels including Machining as required, by keeping alignments in right direction by removing from door leafs.(ii) Re-assembling of wheels, replacing ball bearing, re-fixing on door leafs etc complete all as specified and directed.
Replacing of existing wheel with drive wheel, required two drive wheel for one opening. Drive wheel shall contain either gear on the flange portion or shall have chain sprocket arrangement as per OEM etc complete all as specified and directed.
INTERNAL ELECTRIFICATION
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLSH PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings / fixture etc and open recessed type Plastic Enclosure (Plastic Switch Board) ISI Marked (IS : 14772) for housing switches / sockets complete all as specified and directed
One light point controlled by one way switch.
One fan point controlled by one regulator/switch.
One 3 pin 5 Amps switch socket out on independent board.
One 3 pin 5 Amps socket outlet on same board.
Material and labour for providing point wiring with two runs of 2.5 Sqmm multi stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 2.5 Sqmm single core copper stranded FRLSH PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings / fixture etc and open recessed type Plastic Enclosure (Plastic Switch Board) ISI Marked (IS : 14782) for housing one 15 A switch / sockets complete all as specified and directed
Supply & fix in replacement Switch piano flush button, 240 volts, 5 Amps, single pole, one way complete all as specified and as directed
Supply & fix in replacement Switch socket outlet multipurpose 2 in 1, 5 pin, 5 Amps, 240 volts flush type complete all as specified and as directed .
Supply & fix in replacement Switch Socket outlet multipurpose 6 pin, 5/16 Amps, flush type, controlled by one piano switch, 240 volts,complete all as specified and as directed.
Supply & fix in replacement ceiling rose, surface bakelite, 65 x 50 mm three terminals complete all as specified and as directed
Dismantling and taking down unserviceable street light/recessed ceiling fitting of any capacity ,incl disconnecting the cable connections complete all as directed
Supply and fixing in replacement of LED Security Light Pressure die cast aluminum housing, heat resistance toughened glass, IP 66 protection, better optics for uniform distribution 70/72 Watt, 220/215 Volt 50 Hz with 5 KV surge protection and system lumen output should not be less than 120 lumen per watt complete all as specified and directed. Make:-Havells/Philips/Syska/CG
Supply and fixing in replacement of LED highbay light with PDC housing, integral driver, frame, toughened glass & IP 66 protection, 120 Watt, 220/215 Volt 50 Hz with surge protection of 5 KV and housed in pressure die cast and system lumen output should not be less than 130 lumen per watt complete all as specified and directed. Make:-Havells/Philips/Syska/CG
Supply & fix Air Circulator fans 230 volts single phase,50 Hz,oscillating 450 mm sweep suitable for wall mounting complete all as specified and directed
M&L Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/recessed as required 2x1.5 sq. mm and 1x2.5 sq. mm earth wire drawn in steel conduit and neccessary accessories complete all as directed.
S&F hot dip galvanised perforated cable tray of size 50x300x2 mm thick on wall with powder coated cable cover of size complete with all mounting accessories including nuts bolts etc . Complete all as speicifie and directed.
Taking down the existing surface batten type point wiring of aluminium for Light, fan, Sockets, power sockets, stair case light point complete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc complete all as specified and directed.
Taking down carefully by unscrewing the unserviceable DB Boxes, MC distribution boards SP & TPN with porcelain cutouts etc complete all as specified and directed
Taking down the sub main wiring of any dia / sq mm on teak wood batten / PVC conduit GI earth wire complete all as specified and directed
Material & labour for flame proof point wiring with 2.5 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100V grade conforming to IS 694 drawn through steel ERW conduit of 25 mm (external) flame proof, heavy grade ISI marked including nessary conduit accessories surface on wall, ceiling etc. including flexible metallic conduit FP grade and suitable size nipples for connect the FP junction box to light fitting & fan etc incliding 2.5 sq mm PVC insulated flame retardent copper conductor as in continous earth wire for one FLP light/ fan point controlled by one way metal clad switch of 5 amps capacity complete for one FLP light/ fan point controlled by one way metal clad switch of 15 amps capacity complete all as specified and directed
Supply & Fix FLP - WP Rotary Switch with cable termination box in LM6 16 Amps single pole 240 V ON / OFF MAKE : SUDHIR SWITCH GEARS PVT LTD CAT NO RI / OA / 1010 - 2A /or Equivalent makes BALIGA / ALSTHOM / GEC /& certified by CMRI all as directed & spfd .
Material & labour for sub main wiring with two runs of single core 6.0 Sq mm FRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 6.0 Sq mm single core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in & including PVC casing & caping all as directed and specified . ( Note:- Two runs of 6.0 Sqmm copper cable,one run of earth wire 6.0 Sqmm copper cable including PVC casing & caping shall be measured & paid as one length).
Material & labour for sub main wiring with two runs of single core 4.0 Sq mm FRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4.0Sq mm single core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in & including casing & caping all as directed and specified . ( Note:- Two runs of 4.0 Sqmm copper cable,one run of earth wire 4.0 Sqmm copper cable including PVC casing & caping shall be measured & paid as one length).
Supply and fix in replacement LED tube light along with fixture, 20 watt,4 feet long in aluminium housing complete with system lumen output not less than 100 lumen per watt Make:-Havells/Philips/Syska/CG complete all as specified and directed
Supply & fix in replacement LED recessed light 2'x2',36 Watt in white powder coated CRCA housing complete with system lumen output not less than 120 lumen per watt Make:-Havells/Philips/Syska/CG complete all as specified and directed
Supply and fixing in replacement mirror light fitting 7/9 watt including electrical connections with system lumen output not less than 100 lumen per watt Make:-Havells/Philips/Syska/CG complete all as specified and directed
Supply & fix Vertical double door Distribution board TPN 4 way 200 A rated busbar consisting of MCCB. 125 A 10KA - 1 No. complete all as specified and directed
Supply and fix sheet metal enclosure MCB DB double door SPN 8 way 230 V with neutral link and with 200 A bus bar complete all as specified and directed
Supply and fix sheet metal enclosure MCB DB double door TPN 12 way 230 V with neutral link and with 200 A bus bar complete all as specified and directed
Supply and fix MCB SPN 240 V, 6 to 32 Amps 'C' Curve. complete all as specified and directed.
Supply and fix MCB SP 240 V ,6 to 32 Amps 'C' Curve complete all as specified and directed
Supply and fix MCB SP 240 V, 40 Amps 'C' Curve complete all as specified and directed
Cutting of stone wall & making suitable hole for fixing of flame proof exhaust fan of suitable size and making good complete all as specified and directed.
S&F FLP - WP exhaust fan single phase, 230 V, AC of 305 mm sweep ( 12 " ) , 1440 RPM , with louver incl necessary fixing arrangements suitable at site & model bearing No EF / 140 of make SUDHIR SWITCH GEARS PVT LTD /or Equivalent makes BALIGA / ALSTHOM / GEC /& certifide by CMRI all as directed & spfd .
M/L for earth continuity conductor or main earth lead GI 4mm dia buried in ground / fixed on wall / drawn in Rigid steel conduit.
Material & labour for Earthing complete with galvanised steel earth electrode 60 cm x 60 cm x 6 mm as earthing lead burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth lead wire 4 mm dia by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation/earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 20 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, upto 7.5m length test point etc. complete all as specified and as directed. Note: (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead. Any addition in length shall be adjusted through deviation order.
Earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including galvanised sstrip of size 32x6mm means of bolts, nuts, check nuts & washers etc connected to LA all as shown in electrical plate No 3 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, pre cast slab cover 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/Sqm), funnel with wire mesh, watering pipe of 20mm bore medium grade, including GI strip 32x6 mm dia with GI protection pipe of 40mm medium grade upto 7.5 meter length etc including taking out old unsv GI plate with connected items complete all as specified. Note (i) item includes the cost of 7.5 meter GI Pipe for protection of earth lead. (ii) Item includes the cost of 7.5 meter GI earth strip of size 32x6 mm. Any addition in length shall be adjusted through deviation order.
M/L for earth continuity conductor or main earth lead galvanised iron strip 32X6 mm buried in ground / fixed on wall / drawn in Rigid steel conduit.
M&L for Sub Main wiring with four run of single core 10.0 Sqmm PVC insulated FRLSH multistranded flexible copper conductor cable 660/1100 volts grade drawn in rigid PVC conduit with and including PVC insulated 10.0 Sqmm single core multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly all as specified and as directed. ( Note:- Four runs of 10.0 Sq mm copper cable,two runs of earth wire 6.0 Sq mm copper cable including PVC casing & caping shall be measured & paid as one length).
Supply & fix PVC conduit 25 mm dia for AFNET phone connectivity.(AFNET wiring will be done by AF)
AIR CONDITIONING
Supply, install testing commissioning of hi wall 4 Star rated year 2020 inverter split AC having 2.0 TR Capacity, dual rotor inverter compressor, BLDC motor, filters, iFeel, Blow clean, hidden display, 100% copper coils of indoor, Outdoor including installation kit for indoor & outdoor unit, extra length of refrigerant copper piping, cord cable, drain pipe and core cutting for passing copper pipe & cables from indoor to outdoor unit in stone masonry wall as required at site. Refrigerant shall be echo friendly (R-410a, R-32, R-407) etc complete all as specified and directed.
Material & labour for Sheet metal enclosure with single pole and neutral with two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 volts all as specified and directed.
Material & labour for Submain wiring with two runs of single core 4.0 sqmm FRLSH PVC insulated unsheathed multistranded copper conductor 1100 volts grade cable drawn through and including PVC casing and caping of suitable size and one run of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade FRLSH cable as earth conductor complete all as specified and as directed . Note : All runs of cables and 1 run of casing and caping shall be measured and paid as one meter length of unit complete all as specified and as directed.
SPECIAL ITEMS
S&F Anodized aluminum frame (powder coating minimum thickness of powder coating 50 micron ) any colour as approved for Doors ,fixed partitions etc including jointing cleat and rubber beading/lining and fixed in position with stainless steel screws all as specified and as directed.
M&L for 12 mm prelaminated particle board exterior grade prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with aluminium beadings in Auminium frame work for Doors & partitions.
Dismantling wall/floor and ceiling boards (fiber, pulp, inlsulation,etc) or insulation boards/ slabs/blankets, any thickness, including cover fillets complete all as specified and as directed
Material and labour for suspended false ceiling using powder coated anodized aluminum snap grid frame work. Including Hanger 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G I flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete and including 12mm thick Perforated particle boards or tiles for insulation and accoustic purposes, 60cm X 60cm in size suitably placed in false ceiling grid as per specification and as directed.
S & F for 25mm thick insulated PVC wall lining consisting of PVC Insulated panels having expanded polystyrene (EPS) stuck to 2mm thick plain colour PVC sheet duly fitted into the wall as per specifications and drawing
S & F for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing.
ROAD PATH
Demolition of bricks (laid flat or on edge) or interlocking tiles in floors, channels, kerbes, aprons, etc laid dry of laid dry and pointed.
Demolition of cement concrete in any description and any position not otherwise specifically provided for.
Surface excavation n. exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil.complete all as specified and as directed
Material & labour for hard core (broken stone or boulders) of gauge n.exc 63mm deposited,spread and levelled in layers n.exc 15 cm thick , watered and rammed to a true surface complete all as specified and as directed.
Material & Labour for cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) 100 mm thick as in sub base etc.in path for interlocking tiles, and finishing surfaces of concrete topping even and fair (without using extra cement), and finishing surfaces of concrete in sub-floors, subbases, etc. even and rough to receive the topping layer complete all as specified and directed.
Material and labour for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-35 Grade with grey cement & pigment with placing of paver block with 25mm sand cushioning complete all as specified and as directed (Note : Sand cushioning shall be measured and paid separately as per item below).
Material and labour for 25 mm thick sand filling(sand cushioning) under floors/pavements or in foundation including watering and consolidation for laying interlocking tiles complete all as specified and directed.
Material and labour for cement concrete (1:2:4) type B1, (using 20mm graded stone aggregate) as in copings , benching of man holes including weathering rounded, chamfered angles and throating as directed incl necessary form work. Exposed surfaces of concrete shall be finished even & smooth using extra cement complete all as specified and as directed.
Removing excavated material n. exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and as directed.
EARTHING
Material & labour for earthing complete with copper plate electrode (98 percent conductivity when annealed)of size 60 cm x 60cm x 3.15 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to and including copper strip(98 percent conductivity when annealed) 20x3 mm upto 7.5 mtr long by means of copper/brass bolt, nut, check nuts and washers besides brazing at all joints with GI protection pipe of 40mm bore medium grade up to 7.5 metre and connected to earthing test point all as shown in electrical plate No.3 of SSR part-I and as specified or indicated and testing on completion including excavation & eartwork in any type of soil, PCC (1:3:6) type C-1 chamber, precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4 Kg/Sqm), with frame, funnel with 20mm bore GI pipe medium grade watering pipe, wire mesh and lugs test point etc including taking out old unsv copper plate with connected items NOTE : (i) Item includes the cost of 7.5 metre length GI pipe for protection of earth lead and earth lead . (ii) On testing, if the earth resitance less than specified is not obtained, earthing will be regenerated at no extra cost till the desired earth resistance is obtained.
Supply & Fixing copper earth continuity conductor or main earthing lead of size 20 x 3 mm fixed to wall on batten or recess or chases or burried in ground or drawn in condui9t/ pipe or any other indicated situation for earthing etc as required complete all as specified and as directed.
Supply & Fixing test point terminal block made out of gun metal or phospherous bronze size 75x75x25mm depth, drilled, cutting upper & lower portion for incoming & outgoing including double insulators two coat of synthetic enamel paint complete all as specified and as directed.
Supply & Fixing porcelain insulator suitable to fix copper strip of 25 x 3mm complete all as specified and as directed.
Material and labour Earth connector made out of copper strip 25 x3mm, 60 cm length suitable for 2 inlet earth connection & 6 outlet earth connection with brass nut bolts & washers complete all as directed by Engineer-in-Charge. (For earth continuity to Equipment Supply distribution boards) complete all as specified and as directed.
LIGHTNING PROTECTION
Taking down carefully from roof/wall of the building loose/hanging/deshaped/ serviceable aluminium/copper strips of any size & type including unserviceable insulators etc complete all as specified and as directed
Taking down unserviceable rusted test point terminal boxes from wall on similar position etc complete all as specified and as directed
Taking down unserviceable air termination rod all as directed at the roof top of hanger building etc not more than a height of 10 m complete all as specified and as directed
Supply & fix in replacement aluminium strip 25 x 3 mm on porceline insulator etc not more than 50 cm apart complete all as specified and as directed
Refixing serviceable aluminium strip of any size as obtained from item No 188 & fixing on porceline insulator placed not more than 50 cm apart & fixed with screws & nut bolt complete all as specified and as directed Note : For item No 191 and 192 Porcelain insulators with nuts bolts and screws will measured and paid separately under relevant items)
Supply and fix test point terminal block made out of gun metal or phosphorous bronze size 150x150x75 mm depth , drilled , cutting upper & lower portion for incoming & outgoing including double insulators two coat of synthetic enamel paint complete all as specified and as directed.
Supply and fix air termination, single pointed, aluminium rod 12mm dia with 300mm long fixed on the roof including all fittings, fixtures and PCC 1:2:4 type B1 blocks 100x100x100 mm mounting insulator, bolts and nuts complete all as specified and as directed.
Supply and fix in porcelain insulators with nut bolts/screws for fixing of copper /aluminium strips/GI strips on wall etc complete all as specified and as directed.
Earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including galvanised sstrip of size 32x6mm means of bolts, nuts, check nuts & washers etc connected to LA all as shown in electrical plate No 3 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, pre cast slab cover 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/Sqm), funnel with wire mesh, watering pipe of 20mm bore medium grade, including GI strip 32x6 mm dia with GI protection pipe of 40mm medium grade upto 7.5 meter length etc including taking out old unsv GI plate with connected items complete all as specified. Note (i) item includes the cost of 7.5 meter GI Pipe for protection of earth lead. (ii) Item includes the cost of 7.5 meter GI earth strip of size 32x6 mm. Any addition in length shall be adjusted through deviation order.
Schedule of credit Rs 1271265.50
shah construction
United Sales Corporation
Samruddhi Construction
TAPI PRESTRESSED PRODUCT LTD.
SUYOG CONSTRUCTIONS
Dinesh Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .