Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
22 Aug 2022, 2:00 pmClosed
Executive Engineer Electrical
SKIMS Soura
Renovation /Upgradation /Improvement of existing Electric Network and allied system of Residential Quarters and Hostel Block at SKIMS Soura.
2022_SKIMS_183971_1
eNIT NO.SIMS/HEE/E/ET/33 of 2022-23 Dt. 11-08-20
Open Tender
Electrical Works
Item Rate
30 days
SKIMS Soura
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
As Described in SBD
₹20,000
Yes
1 Sept 2022
13 Aug 2022
23 Aug 2022
13 Aug 2022
22 Aug 2022
13 Aug 2022
Amount
Part A (Hostel Block)
Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in existing surface/recessed medium class PVC conduit as required .
a) 3X4 mm² multi strand pvc insulated copper.
b) 3X2.5mm² multi strand pvc insulated copper.
c) 3 x 1.5mm² multi strand pvc insulated copper.
Supply and fixing of 25mm medium class PVC conduit 2mm thick along with accessories like with rowel plugs ,screws ,sadlles ,bends etc complete as required at site . (in surface manner) .
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. A) 3½ X 185 sq. mm for cable feeding power Supply to New Married Doctors SR Hostel
Replacement of existing damaged LT Panel By New One as described below
BUSBAR:-500 Amp. 4 strip Al. Busbar , Out-going:- 200 Amp FP MCCB having breaking capacity - 25 KA with Ics=Icu=25 KA, with Rotary Handle operating Mechanism - 3 No. 160 Amp FP MCCB having breaking capacity - 25 KA with Ics=Icu=25 KA, with Rotary Handle operating Mechanism - 3 No.
P/F Double locked medium duty pvc channel 25x 2mm.
SITC of Wall mount fans 400 mm with Plastic Body as specified below 1.Motor Brushless DC (BLDC) 2.Governing standard I.S.2997 (Latest) 3.Power Consumption: Approx. 100 Watts 4.Power supply Single phase AC 230V, 50Hz 5.Speed: 1200 -1400 rpm with regulator 6.Sweep: 400 mm 7.Air Flow: 72-80 m3/min. 8..motor protection through thermal 9.overload protection device 10.It should have minimum 3 levels of speed control. Features: Suitable for mounting on walls with easy mounting arrangements, Noise level shall be within limits adjustable upward and downward tilt mechanism .
Supply, Installation, Testing and Commissioning of 1200 mm sweep, Ceiling fan with 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V,50 Hz, single phase AC Supply, earthing etc. complete as required.
Supply installation testing and commissioning of 250mm shutter type plastic body exhaust fans 900/1600 RPM , the job includes of wall opening .
SITC of Electric Heater / Geyser of capacities as mentioned below with following parameters . 1.Energy saving. 5 Star Certification by BEE 2. Provision of Temperature regulation by means of external Knob 3. Power Rating:- 220/ 230V, 50 Hz, Single Phase. 4. Maximum Rated Pressure.= 8 bar 5. Installation Type Vertical / Horizontal mounted as per site requirement 6. Body Type:- Rust, water proof and Shock Proof outer body with attractive looks and corrosion resistant inner tank made of cold rolled steel ,resistant to hard water. 7. Element Type:- glass coated heating element to prevent from corrosion and hard water. 8.Safety Valve maximum pressure =8 bar maximum 9. Energy efficiency feature:- Should have high density PUF insulation for energy Saving 10. Anti syphon system to prevent back flow of water. 11. Should have Indicating Lamps for ON & CUTT OFF. 12. Confirming to :IS 2082:2018 , IS 302-1, IS 302-2-21 ( As per Analysis )
a) 50 litre (2KW)
b) 35 litre (2KW)
Replacement/Supply and fixing of following piano type accessories in place of damaged one .
a) Ceiling Rose
b) PVC Plate/ Block
c) 5 A 3 Pin Socket
d) Fan Regulator Stepped Type (2 Way)
e) 6 pin 15/16 Socket outlet
f) 6 pin 15/16 Switch
f) 5 A Switch
g) Bell Push/ Buzzer
P/f of bakelite /Phenolic Laminated Sheet 3 mm thick
P/F of fan hook S Type, U Type, J Type
P/F of MCB Box PVC 2 way
Supplying and fixing, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a) Single pole 5 A to 32 A rating
b) 40 A Double Pole.
Dismantalling of existing non funtional Geyser and refixing of same after carrying out repairs by way of changing of damaged accessories including washing,mopping and changing of rusty nut and bolts welding as required.
Replacement/Supplying and fixing of Geyser accessories.
a) Coil type (long)
b) Coil type (short)
c) Triangular type.
d) Thermostat Geyser.(Long/short)(insertion type)
e) Thermostat Geyser.( Capillary type)
f) Geyser element Coil type 2000 watts ( Required for Venus magma/ Havells/Ferroli Geysers)
g) Flexible PVC connection for Geysers of various capacities 12''
h) Flexible PVC connection for Geysers of various capacities 18''
i)Geysers indicator.
j) flung washer.
Part B: Residential Quarters
Supply and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 185 mm sq. 3.5 core cable direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering from LT panel to DB of A Quarters(
Supplying and making end termination with aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 185 sq. mm (57mm)
Supplying and fixing, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Double Pole 100 Amps for Quarters
b) Single pole 5 A to 32 A rating
c) 32 A Double Pole.
d) 40 A Double Pole.
e) 63 A Double Pole.
Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface/recessed medium class PVC conduit as required .
3 x 4 mm² multi strand pvc insulated copper.
3 x 2.5mm² multi strand pvc insulated copper.
3x 1.5mm² multi strand pvc insulated copper.
Supply and fixing of 25mm medium class PVC conduit 2mm thick along with accessories like with rowel plugs ,screws ,sadlles ,bends etc complete as required at site . (in surface manner) .
M/s BILAL ELECTRIC GOODS
K.J. Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .