Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
2 Oct 2024, 3:00 pmClosed
GE(I R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
REPAIR AND REPLACEMENT OF SPARES TO HT VCBs 11 KV SUB STATIONS RMUs LBs 11 KV OH LINES GOD LIGHTNING ARRESTORS HT UG CABLES LT UG CABLES CONTROL CABLES LT PANELS APFC PANELS LT SWITCH GEARS AND ITS CONNECTED EM WORKS AT EETF DSST DSP CIC MRSAM ARMY M
2024_MES_671450_1
8976
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE(I) R AND D RCI, HYDERABAD
MES enlisted Class D category b ii and Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹94,000
Yes
17 Oct 2024
4 Sept 2024
4 Oct 2024
4 Sept 2024
2 Oct 2024
18 Sept 2024
Amount
Supplying, laying, jointing, testing and commissioning of 3 Core 120 Sqmm, 11000 volts grade, Earthed, HT XLPE insulated, insulation screened with extruded semi-conducting compound in combination with copper tape (0.3 KA for one second), cores laid up, PVC inner sheath with fillers, galvanized steel flat strip armoured, heavy duty, electric cables, with multistranded aluminium conductor, conductor screen with extruded semi conducting compound and overall PVC sheathed cable as per IS-7098 (Part-2) 1988 with latest amendments, replaced with burntout HT Cable laid in trenches / passing through pipe/duct/road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc., including disconnecting and taking down unserviceable cable complete all as specified and directed for the following sizes:- Note : Earthwork Excavation, sand cushioning, GI pipe and cable protection will be measured and paid separately.
All as per Sl Item No 1 above, but for 3 Core 95 Sqmm HT cable
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in hard/dense sol complete all as specified and directed.
Returning, filling in , including spreading, levelling, watering and well ramming in layers not exceeding 25cms complete all as specified and directed.
Removal of excavated soil to a distance not exceeding 50 mtrs and deposited where directed at a level not exceeding 1.5mtrs above the starting point all as directed.
Supply and spread natural dry river sand for cable cushioning in trenches and punned down all as specified and directed. Note : Prunned thickness will be measured for payment.
Supply and lay un reinforced pre cast concrete cable cover class LV type II flat size 300X180mmX40mm all as specified and directed.
Cutting of existing bituminious/PCC road or flooring/plinth protection, for laying of GI pipe in road intersection for passing of LT XLPE cable including excavation in any type of soil, returning and filling in and making good top 30cm of the trench by providing PCC 1:2:4 type B1 using 20mm graded stone aggregate to flush with existing road surface complete all as directed.
S&F, 150mm dia GI pipe light grade fixed to walls/poles or laid in trenches, road crossing etc., for protection of underground cable/earth strip including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed on walls/poles complete all as specified and directed
M&L in repairs, Earthing complete with copper earth plate electrode of size 600 x 600 x 3.15mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5m below normal ground level connected to copper strip 20x3mm as earth lead by means of bolts, nuts, washers and check nuts made out of galvanized iron or steel all as shown on Electrical Plate No. 3 of SSR Part-I including testing on completion complete all as specified and directed.
Note 1: The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, 50mm thick RCC 1:2:4 type B-1 using 20mm graded stone aggregate cover slab reinforced with 6 Nos of 8mm dia TMT bars both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 25mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub-heading earthing, specified on Sl Page No. 422 of SSR Part-II. 2. Copper earth strip beyond 7.5m will be measured and paid separately.
M&L in repairs, copper earth strip 20 x 3mm buried in ground or fixed on wall or drawn through pipe or fixed to poles or any other indicated situation for earthing complete all as specified and as directed.
Supply and replacement of unserviceable rubber matting with new one of 12mm thick 1M X2 M LT ISI marked complete all as specified and directed by Engineer -in-Charge
Supply and replacement of unserviceable HT rubber mat with new one of of size 1mx2mx19mm ISI marked complete all as specified and directed by Engineer -in-Charge.
M&L, locating fault in 11 KV HT underground cable of any sizes with the help of fault locator vehicle organized from TSSPDCL/TSTRANSCO by injecting necessary high voltage to the faulty cable within 12 hours of time from time of reporting of fault all as directed by Engineer in Charge. Note : Quoted rate shall deemed to be included the necessary charges towards liaisoning for arranging fault locating vehicle, transportation of trained technicians and charges payable to Electricity Department.
Supply, erection and testing and commissioning of 132 KV, Oil filled out door, live tank type Current Transformer (oil impregnated) 132 KV class 100-50/1-1-1A CT Ratio, as per IS 2705 (1992) with insulator electrical connection as per manufacturers instruction complete, CT shall be with rated voltage 145 KV, accuracy class 1.0 for core1 : 15VA/1.0, core 2 : 15VA/5P 20, core 3 : PS VK-350V @ 50/1 RCT 3 ohms @ 50/1 Im 30 mA STC 31.5 KA for 1 sec, creepage distance : 3625mm, Insulation level : 275/650 KV, painted tank with SS Bellow / N2 cushion replaced the old one with new all as specified and directed. (MRS) Make : ABB POWER PRODUCT/SIEMENS/CROMPTON GREAVES LTD / LAMCO
Supply, erection, testing and commissioning of 132 KV Potential Transformer Ratio 132KV/1.732/110V/1.732, Wind-1: 10VA/0.2 RVF 1.2 cont and 1.5 for 30 secs, creepage distance 3625mm replaced the old one with new all as specified and directed. (MRS) Make : ABB POWER PRODUCT/SIEMENS/CROMPTON GREAVES LTD/LAMCO
Taking down the unserviceable power factor capacitors of different capacities from the capacitor panel board after disconnecting the electric supply, Supply and fixing of power factor correction capacitors, All Poly Propelene (APP) Box type, (LTBCU), rectangular in shape, heavy duty, with over current withstand capability 3 x In, operating losses 0.35 W / kVAr, peak inrush current withstand capability 500 x In, number of switching operations per year : 20000, maximum ambient temperature 70 degree celcious, minimum operating life 300000 hours, various KVAR rating, 440 V, with suitable fixing arrangement including connection with suitable copper cables and testing complete all as specified and directed. Note : (i) Capacitors shall conform to IEC 831-1, with total losses not more than 0.25W / KVAR. (ii) Copper cables, thimbles will be measured and paid for seperately under respective items. Make : Cat No LTXL (Box series : LTBCU) of make L&T or equivalent model
All as per Sl Item No 17 above, but cylindrical type (LTCCU)
Dismantling unserviceable power factor control relay (APFC) 4 step, from the power factor capacitor panel boards, supply and fix power factor control relay (APFC) 4 step including necessary electric connections and testing complete all as specified and directed. Make : L&T / HPL / Neptune
All as per Sl Item No 19 above, but 6 step controller relay.
All as per Sl Item No 19 above, but 8 step controller relay.
All as per Sl Item No 19 above, but 12 step controller relay.
Disconnecting and removing the unserviceable burnt out contactor, supply and fix new power contactor MNX 185, 50Hz, 230 Volts AC Coil grade capacity including connecting and testing complete all as directed.
All as per Sl Item No 23 above, but for MNX 70 capacity
All as per Sl Item No 23 above, but for MNX 32 capacity
All as per Sl Item No 23 above, but for MNX 9 capacity
Taking out unserviceable single phase Analoge / Digital type Ammeter / Voltmeter, square type from LT / APFC panel boards and supply and fixing new Digital type Single Phase Ammeter / Voltmeter, square type suitable with connection and testing complete all as specified and directed
Taking out unserviceable three phase Digital / Analog type Ammeter & Voltmeter, square type from LT / APFC panel boards and supply and fix new Three Phase Digital type Ammeter & Voltmeter including connecting and testing complete all as directed.
Taking out unserviceable LED type indicator lamp unit from the panel boards, supply and fixing LED type indicator lamp unit of red/ yellow/ blue/ green/ Amber with bulb including connection and testing complete all as specified and directed. Make: AE/IMP/KAYCEE/C&S/L&T
CHITRA ENGINEERING CORPORATION (BID ID -3111484)
SUN LIGHT HOUSE (BID ID -3112405)
BHAGYARAM ENTERPRISES (BID ID -3112392)
ELEVATORS MAINTENANCE ENGINEER WORKS (BID ID -3113701)
SRI SAI ENTERPRISES (BID ID -3112433)
DPS sales and services india (BID ID -3112729)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .