Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹44.2 LAccepted-AOC HOUSE NO 646 30 ADARSH NAGAR ROHTAK HARYANA 124001 | ROHTAK | ROHTAK | HARYANA | 124001 | ₹44.2 L | 1 | Accepted-AOC L1 |
| 2 | 2₹47.3 L+₹3.1 L (6.91%)Rejected-Finance 341 21 SHASTRI NAGAR MUNSHI SAINI WALI GALI 341 21 SHASTRI NAGAR 124001 | ROHTAK | HARYANA | 124001 | ₹47.3 L+₹3.1 L (6.91%) | 2 | Rejected-Finance DUE TO HIGHEST RATE |
| Sl No | Description | Qty | Unit | The Behlba Co-op L&C Society Ltd. L1 | The Ashubhai Co-op L&C Society Ltd. L2 |
|---|---|---|---|---|---|
| 1.01 | Flexible wire 40/76 (item PWD approved) | 4,000 | Metre | 12.49 ₹49,960 Lowest | 13.36 ₹53,440 |
| 1.02 | Electrical tape box (with 30 pieces of tapes in it) | 40 | Each Set | 308 ₹12,320 Lowest | 329 ₹13,160 |
| 1.03 | Hanging Swicth | 1,200 | Each | 21 ₹25,200 Lowest | 22.47 ₹26,964 |
| 1.04 | Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K(5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 45 Watt | 1,200 | Each | 1,648 ₹19,77,600 Lowest | 1,763.36 ₹21,16,032 |
| 1.05 | Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K(5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 120 Watt | 250 | Each | 4,158 ₹10,39,500 Lowest | 4,449 ₹11,12,250 |
| 1.06 | Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K(5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 200 Watt | 30 | Each | 6,321 ₹1,89,630 Lowest | 6,763 ₹2,02,890 |
Tender Value
₹42.1 L
EMD Value
₹84,290
Closing Date
4 Sept 2026, 9:00 amClosed
Brijesh
Municipal Committee Sampla
Proving and Installation of street Illumination System in All Ward of MC Sampla.
2026_HRY_544312_1
2026AC376AE5 2867 45DA 9EC5 BD966E7FF38E319ULB
Open Tender
Civil Works
Works
180 days
Sampla
Proving and Installation of street Illumination System in All Ward of MC Sampla.
2 documents required · 2 mandatory
₹5,000
Yes
₹84,290
Yes
11 Sept 2026
28 Aug 2026
4 Sept 2026
28 Aug 2026
4 Sept 2026
28 Aug 2026
28 Aug 2026 - 30 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Flexible wire 40/76 (item PWD approved) | 4,000 | Metre | 1 | ₹4,000 |
| 1.02 | Electrical tape box (with 30 pieces of tapes in it) | 40 | Each Set | 1 | ₹40 |
| 1.03 | Hanging Swicth | 1,200 | Each | 1 | ₹1,200 |
| 1.04 | Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K(5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 45 Watt | 1,200 | Each | 1 | ₹1,200 |
| 1.05 | Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K(5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 120 Watt | 250 | Each | 1 | ₹250 |
| 1.06 | Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K(5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 200 Watt | 30 | Each | 1 | ₹30 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
BOQ_623840.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .