Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹48.1 L+₹2.3 L (5.02%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | Rejected-Technical | - | Rejected-Technical Rejected due to non submission of tender fee |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
4 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) Campbell Bay
GE (I) Campbell Bay, Army Land, Great Nicobar-744302
PROVN OF MES COMPLAINT CELL AT CGDHQ-10 UNDER GE (I) CAMPBELL BAY
2022_MES_523236_3
8816
Open Tender
Civil Works
Works
180 days
GE (I) Campbell Bay
Please refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (I) Campbell Bay
₹87,000
28 Nov 2022
14 Jul 2022
6 Aug 2022
15 Jul 2022
4 Aug 2022
21 Jul 2022
Amount
Excavation over areas, n.exc 1.5m in depth for foundation etc. and getting out in soft/disintegrated rock all as specified and as directed
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for foundation of poles, structures, stay rods, laying of underground cable etc complete
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as directed.
Excavating hard/dense soil in post holes (or similar holes) each n.exc 0.5 Cu.m getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm watering and removing surplus soil to a distance in n.exc 50m and making good surface complete all as specified and as directed.
M & L hardcore of broken stone or boulders of gauge n.exc.63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and well rammed to a true surface,complete all as specified and directed.
M&L cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate 125 mm thick as in foundation, sub base ect complete all as specified and as directed.
Form work to sides of concrete foundations, footings, bases of columns, rafts and raft beams, sided and soffits (if any) of foundation and plinth beams; and similar work; vertical or to better rough finished flat surface of concrete completed all as specified and as directed
M & L formwork to sides of pillars, posts, struts, piers, columns and stanchions square, rectangular finishes rough surfaces of concrete.etc finished rough surfaces of concrete complete all as specified.
M & L Reinforced cement concrete M-30 (Design Mix Concrete) using 20mm graded aggregate in foundations, including rafts, footings, plinth beams, bases for columns, etc. basement slabs, under ramed piles and mass concrete complete all as specified and as directed. (Note:- Reinforcement and form work will be measured and paid separately)
M & L Reinforced cement concrete M-30 (Design Mix Concrete) using 20mm graded stone aggregate in columns, pillars, piers and struts, posts etc. complete all as specified and as directed. (Note:- Reinforcement and form work will be measured and paid separately)
M&L TMT bars 10mm dia and over, as reinforcement. cut to length, bent to shape required including crancking bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete all as specified.
M&L TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders, cut to length , bent to shape required inluding cranking bending hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9mm dia or securing with clips complete all as specified.
S & F Rolled sections as in main and cross beams,hip and jack rafters,purlin where connected to common rafters and running rails and guides for sliding doors,fixed with angle cleats or other connecting plates conforming Fe-410W (Gde-E-250) quality -A complete all as specified and as directed
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.
S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.
S&F for 1.25 mm thick Galvanised mild steel sheet as in valley gutters fixed with rivets or other suitable arrangements over MS brackets ,trapezoidal shape of required profile with desired slope etc complete all as specified.
S&F PVC (SWR) pipes 160mm dia. single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by the Engineer-in-Charge.
S&F 160mm dia. PVC (SWR) bends complete all as specified and directed by the Engineer-in-Charge.
M&L precast cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate as in block masonry with solid blocks exceeding 10cm in width and set in cement mortar 1:4 complete all as specified.
M&L for rendering 15mm thick with CM 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L applyign two coats of oil bound distemper over a coat of chalk whitening primer including preparing the new surfaces wall complete all as specified and as directed.
M&L 20 mm thick rendering on fair faces of brick/concrete surfaces in cement mortar 1:6 in two layers(15 mm thick backing coat + 5 mm thick finishing coat ) finished even and smooth without using extra cement complete all as specified.
M&L applying two coats of acrylic antifungal exterior grade paint over a coat of primer including preparation of new wall surfaces complete all as specified.
M&L preparation of new or previously untreated steel surfaces of any description, not exc. 10cm in width or girth and applying two coats of synthetic enamel paint over a priming coat of red oxide zinc chrome primer complete all as specified and directed by the Engineer-in-Charge.
M&L for powder coated aluminium anodised door, window, partition aluminium sections,with sliding or openableshutters including frame and necessary jointing cleats,glazing clips,powder coated aluminiumsnap beading,screws etc:complete and also including , such as cobra hinges,hooks&eyes ,peg stays and star lock for window,etc including connected items,with and including,making good to the disturbed portion with its original specifications etc. complete all as specified and as directed.
S&F 5.5mm thick sheet glass ordinary quality in any size of pane. each fixed to steel frame with oil putty in square including steel pin complete all as specified.
M&L 12 mm thick prelaminated particle board,exterior grade, prelaminated both sides with decorative choice laminations fixed to aluminium doors / partitions all as specified and as directed.
M & L machine cut cudappa stone slab 20 to 25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
S & F 100mm size aluminium alloy butt hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised type C-21 complete all as specified and directed
S&F 150mm long extruded aluminium alloy handles, fabricated stone type, anodised complete all as specified and as directed by the Engineer-in-Charge.
S&F 150mm size aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed by the Engineer-in-Charge.
S&F 250mm long aluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section complete all as specified.
S&F Aluminium (Die-cast) body door closer hydraulically regulated, designation No. 3 universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 62 to 80 kg complete all as specified and as directed.
S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm, fixed with aluminium wire staples or cover fillets all as specified.
Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with,including 20mm thick screed bed in CM 1:4 complete all as specified and as directed by Engineer-in-Charge.
S&F False with powder coated exposed GI grid suspension system a grid of 600mm x 600 mm,grid of modular size 600mmx600mm shall be supported by 4 mm dia GI wire from purlins/soffit with and including 4mm thick high pressure steam curedwith non-asbestos fiber cement designer ceiling board (Density>1200kg/cum) of size 595mm x595 mm complete all as specified and as directed
Removing excavated material from site to a distance exceeding 250 metre not exceeding 500 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified.
M&L 75 mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection and paving finishing concrete surface even and smooth without using extra cement complete all as specified.
Dismantling of stone slabs and tiles of any description or thickness in floors apron,cills etc laid bedded and jointed in any mortar and removing materials from site of work complete all as directed.
M & L for factory made chequered cement concrete coloured tiles 30cmx30cmx25mm thick conforming to IS-13801-1993 with grey cement and pigments, set jointed and pointed in neat cement slurry in floor, paving and steps including 20mm thick screed bed in CM 1:6 for laying floor finished complete all as specified and as directed.
Material and Labour for point wiring (concealed) on walls and surface on ceiling complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic medium grade rigid PVC conduit heavy grade accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls by cutting chases using machine and making good the disturbed surface, with and including suitable boxes ,switch plates of suitable make and 1.5 sq mm multistranded copper conductor flame retardant pvc insulated cable earth continuity wire connected to earth dolly complete for the following complete all as specified and as directed. (a) One light point controlled by one switch.
(b) One Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator
(c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on same board .
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
Material and Labour for point wiring complete with 4.0 Sqmm PVC insulated unsheathed single core multistandded FRLS Copper conductor ISI marked,1100 Volts grade,(separate wire for phase and nutral for each circuit from DB) drawn though in and including 25 mm PVC conduit including all pvc conduit fittings for concealed wiring and terminated to MS box of 1.6 mm thick including cutting chases,holes for conduits and sinking's for boxes,DBs and making good disturbed surfaces of walls, floors etc and 3 mm hylum sheet for mounting switches,switch sockets combination, regulator etc including 4.0 Sqmm PVC insulated FRLS copper coductor cable as earth continuity conductor and connecting to common earth dolly for power point including all necessory screws,clamps & misc items complete all as specified and as directed.
S&F Switch piano , single pole, one way 6 amps including necessary screws, clamps etc complete all as specified.
S&F ceiling fan regulator step type, 220v, 50hz,AC including necessary screws, clamps etccomplete all as specified.
S&F Switch socket combination 5 amps,3/5 Pin, including necessary screws, clamps et complete all as specified.
S&F Switch socket combination 5/15 amps,3/5 Pin, including necessary screws, clamps et complete all as specified.
M&L sub main wiring with 2 run of 6 sqmm PVC insulated heavy duty,ISI marked and unsheathed cable with multistranded FRLS copper conductor and drawing through in and including PVC conduit of suitable size and connecting terminal ends to plug sockts and DB's including provision of one run of 6 Sqmm insulated FRLS copper conductor for earth continuity conductor and connecting to earth dolly complete including all screws clamps and other misc items coplete all as specified. (Make:- Plaza / Havells / Polycab / FINOLEX)
S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole and neutral with 200 amps rated bus bar, SPN as incomer flush to wall/surface including lugging,screws,clamps and necessary electrical connections, civil works and making good disturbed surfaces complete all as specified and as directed.
S&F MCB 'C' curve single pole 5 to 32 Amps complete all as specified and as directed.
S&F MCB 'C' curve single pole nutral 240 volts 40 Amps complete all as specified and as directed.
Supply and fixing complete LED fitting luminaire of size 600 mm x 600 mm,35/36 watt, with having minimum efficiency 100Lumens/Watt, 220 V,50Hz, AC, minimum PF 0.9 with electronic driver, compitable for recessed/surface mounted type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size connecting from termination point to load point including all nessary accessories complete all as directed by Engr-in-Charge.
Supply and fixing,LED light fitting of capacity not less than 20W,minimum lumens 90 lum/watt,4feet length,compatible for mounted on wall/ceiling/surface, 220V,AC,50Hz, minimum PF 0.9 comprising of decorative box type batten(Compitable for T-5/T-8 LED tubes) ,bipin holders,LED tube light with integrated electronic driver, holder,internal wiring connecting up with twin core flexible copper conductor cable of suitable size drawn though flexible pvc conduit suitable size from ceiling rose complete all as directed by Engr-in-Charge.
Supply and fixing, LED light fitting of capacity not less than 9W,minimum lumens 90 lum/watt,2feet length,compatible for mounted on wall/ceiling/surface, 220V,AC,50Hz,minimum PF 0.9 comprising of decorative box type batten(Compitable for T-5/T-8 LED tubes) ,bipin holders,LED tube light with integrated electronic driver, holder,internal wiring connecting up with twin core flexible copper conductor cable of suitable size drawn though flexible pvc conduit suitable size from ceiling rose complete all as directed by Engr-in-Charge.
Supply and fixing of Energy efficient 5 Star Rating,BLDC motor ,dust proof,Ceiling Fan 1200 mm Sweep size,copper winding with minimum air delivery of 210 cu.mtr/min,A.C, single phase, 220 volt 50 Hz including canopy reel , fliexible copper conductor fixing with necessary lugs drawn through flexible pvc conduit from ceiling rose,including necessary hook, rubber bush&safety pin all necessary accessories complete all as directed by Engr-in-charge.
Supply & fixing of heavy duty exhaust fan,A.C, single phase,50Hz, 230/240 V of size 300 mm sweep, with minimum 1350 rpm with louvres, and wire mesh for suitable size to be fixed before fixing of louvers,including necessary wiring along with necessary accessories and neccsary civil works alongwith making good disturbed surfaces etc, complete all as specified and directed by Engr-in-Charge.
S&F of ceiling rose three terminal surface backallite type complete all as directed by Engr-in-charge.
Supply and lay GI tubing 50 mm dia, light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete
Supply,test,laying & commissioning of XLPE insulated, armoured (heavy duty) electric cable with aluminium stranded conductor, 1100 volts grade, 2 core 6 sqmm laid in trenches / duct/ fixed to wall with suitable size clamps / passing through pipe/Tunnel/under ground/surface up to the termination point(as directed by Engr-in-Charge) and cable end terminations crimped with suitable size cable lugs, cable glands with tool,nuts,bolts etc and connecting end terminations to DBs/LT panel/Busbar etc complete all as specified and directed by Engr-in-Charge :-
Supply and fixing of complete LED security lights 36W with electronic driver,220v,AC,50Hz, not less than 100 lum/watt,High performance low wattage street light with Single Die ceramic base high power LED light source, IP66 protection,PDC housing with finless design and high impact resistance (IK08) glass cover with integrated street Light optics,compitable for pole dia 40mm dia , including 40mm dia ,1.5mtr long bend,including necessary screws,nuts,bolts,suitable size clamps for fixing on wall/surafce includig necesarry wiring from light to termination point compelete all as directed by Engr-in-Charge.
Supply,test,laying & commissioning of XLPE insulated, armoured (heavy duty) electric cable with aluminium stranded conductor, 1100 volts grade, 2 core 16 sqmm laid in trenches / duct/ fixed to wall with suitable size clamps / passing through pipe/Tunnel/under ground/surface up to the termination point(as directed by Engr-in-Charge) and cable end terminations crimped with suitable size cable lugs, cable glands with tool,nuts,bolts etc and connecting end terminations to DBs/LT panel/Busbar etc complete all as specified and directed by Engr-in-Charge :-
M&L for Supply,test,erection & commissioning of Steel tubalar swaged poles staying in a truely vertical position till the foundations are properly set with the help crane complete with cast iron base plate, finial taper plug, bolts, nuts & screws including drilling of holes to poles for clamps & hooks for running of earth wire/Strip complete all as specified type 410 SP-31,9 mtrs length poles complete all as directed by Engr-in-Charge. Note:-(i)Crane charges for erection shall be deemed to be including in quoted rate. (ii) Earth work,PCC,coping shall be measured and paid separately. (iii) The rates include staying the poles in atruely vertical position till the foundations are properly set. (iv)The rates include cast iron base plate,nuts,bolts,screws,painting of steel tubular poles,drilling of holes in steel tubular poles for fixing of clamps,hooks for continuous earth wire/strip.
Supply and fixing of PVC Junction box of size 140mm x 140mm x95mm ,light weight pole mounting hinged type including MCB Sp 06Amps -1 No including necessary clamp for MCB mounting and mounting of Box on pole with MS flat frame arrangement and necessary connector for looping in and looping out cable connection and suitable glands complete all as directed by Engr-in-charge.
S&F of HDPE double wall corrugated pipe confirming to IS -14930 Part with IP protection IP-67 having outer dia 50mm and internal dia 38mm complete terminated up to termination end point complete all as directed by Engr-in-Charge.
S&F of HDPE double wall corrugated pipe confirming to IS -14930 Part with IP protection IP-67 having outer dia 40mm and internal dia 32mm complete terminated up to termination end point complete all as directed by Engr-in-Charge.
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable protection pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
Supply and laying PCC (1:2:4) 20mm graded aggregate type B1 forcoping of PCC for poles long complete all as directed by Engr-in-charge
Supply and laying PCC (1:2:4) type B2 40mm graded aggregate for foundation of PCC for poles long complete all as directed by Engr-in-charge
M&L for earthing complete with galvanized steel earth plate electrode 600x 600 x 6.3 mm buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to galvanized earth lead wire 4mm dia (upto 7.5 m in length from earth plate) by means of galvanized iron or steel bolts, nuts, check nuts and washers, and connected to equipments as directed, including funnel with GI med grade watering pipe 20mm bore, wire mesh charcoal or coke and common salt in alternate layers, of 15cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C-1, 50mm thick pre cast RCC 1:2:4 type B1 cover slab reinforced with 8mm dia reinforced bar 15cm C/C and earth lead handle protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I and as directed
T.M.RAMANATHAN AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .