Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC DSS 194 POCKET A SEC 14 125001 | HISAR | HARYANA | 125001 | L1 | Accepted-AOC accepted | |
| 2 | L2₹16.8 L+₹2,173.50 (0.13%)Rejected-AOC 1128 SECTOR 22 B NEAR AROMA PETROL PUMP CHANDIGARH UT 160022 | CHANDIGARH | CHANDIGARH | 160022 | L2 | Rejected-AOC rejected | |
| 3 | L3₹18.3 L+₹1.5 L (8.72%)Rejected-AOC TAILOR MARKET MAIN BAZAAR MANDI ADAMPUR 125052 | HISAR | HARYANA | 125052 | L3 | Rejected-AOC rejected |
Tender Value
₹21.2 L
EMD Value
₹42,340
Closing Date
25 Apr 2022, 5:00 pmClosed
Executive Engineer
Electrical Division PWD BnR Br. Rohtak
Pdg. New Fire Alarm system in various Block in Mini Sectt. Complex at Jind. Recall
2022_HRY_216534_1
PWD/Electrical/60792
Open Tender
Electrical Works
Item-rate/Agreement basic
60 days
Jind
Please refer to tender documents as per DNIT conditions.
3 documents required · 3 mandatory
₹1,000
₹42,340
Yes
11 Jul 2022
11 Apr 2022
26 Apr 2022
11 Apr 2022
25 Apr 2022
11 Apr 2022
Amount
S/E of PVC unsheathed copper conductor cable single core 1100 volts grad in pipe of suitable size excluding cost and erection of pipe. (HSR 31.40) i) Cable size 1.5 sqm(3/0.81 mm)
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall /ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. (HSR 31.44). b) 25mm dia
SITC of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 3 Serial Ports. The pane\l shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in –charge of work. Make: Cerberus by siemens/Honeywell Morley/ Edwards EST3.
SITC of addressable multisensor detector with a combination of Optical and Thermal including mounting base, auto addressing feauture as required. Detetctor should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module after 20 devices) (Makes: Siemens Cerberus OH921+DB-11, Honeywell Morley / Edwards EST3.
SITC ofaddressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) (Makes:Siemens Cerberus, Honeywell Morley / Edwards.
SITC of intelligent analog addressable type Manual Call point having surface or flush mounting option fully compliant to EN54 having rotary decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect upto the entire satisfaction of Engineer-in-Chage of the work. Make- Morley/ Siemens/ Edwards.
SITC of addressable Loop powered hooter with strobe complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required complete the of in all respect upto the entire satisfaction of Engineer - in - charge of work. Make- Morley/ Siemens/ Edwards..
: SITC of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink sulphate as bare chemical class 1 material PSPA fixed on 3mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. (Make: Glolite / OMEX/ SAVEMAX)
SITC of minimum 1000 Mtr. Range Kheraj make SIRON generator provided at the roof of the building with separate Power Supply, relay etc. complete the in all respect up to the entire satisfaction of Engineer-in-Charge of work.
SITC of 9 U rack for switch Mounting with Fan and power Strip, PDU, Hardware Mounting Kit Make: Netrack/Comrack/D-Link
SITC of Addressable Control Relay Module with flexible network structures with a maximun switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Make- Bosch/ Morley/ Siemens/ Edwards.
SITC of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/ voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment). Make- Bosch/ Morley/ Siemens/ Edwards.
SITC of UL/EN54/LPCB listed and FM Approved Line Isolator for Isolating the section of circuit in case of short in the addressable Loop wiring Makes :Make- Bosch/ Morley/ Siemens/ Edwards.
SITC of Analog Addressable type Active Repeater fire alarm panel with Backlit LCD Display, having controls for reset, mute, Accept, Silence alarms and self test conforming to BS5839 standards and Duly approved by EN54/UN54/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work.Make- Bosch/ Morley/ Siemens/ Edwards.
SITC of fault isolator/base to check short circuit every 20 Deductors
Mechnical foam Type Fire Extinguisher 50 Leter capacity with OUTSIDE CYLINDER , CO2 CYLINDER 1 KG CAPACITY for Above AFFF foam compound for extinguisger , 3000 mls capacity combine . Make Safex / minimax/ ceasefire.
3 Meter Rubber pipe with EPDM Quality with squzeer grip nozzle for Jet length I.S.I Mark
Supply of ABC Stored Preassure type Fire Extinguisher 6kg. Capacity (5 year warranty) bearing ISI Mark for fire fighting ABC class of fire extinguisher will be manufactured strictly as per BIS IS:683:2006 bearing ISI Mark EN3 615 approved powder (Safex Make )
‘SAFEX’ Co2 type Fire Extinguisher 4.5Kgs. Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and Squeeze Grip / wheel type valve with initial Charge as per IS: 15683:2006 specification, bearing ISI Mark & EIL approved.(Safex Make )
Tele Net Marketing Pvt Ltd
Prime Computers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .