Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹6.2 L+₹34,088 (5.85%)Accepted-Finance 1763 JOSHI VAS OPP RAMJI MANDIR B H NAVRANGPURA POLICE STATION NAVRANGPURA AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L2 | Accepted-Finance L2 |
Tender Value
₹5.8 L
EMD Value
₹11,535
Closing Date
10 May 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EEElectricalEDAhmd
BSNLED2ndFlrTENavarangpuraAhmedabad
CompMtceofHPACandcallbaserepairofConventionalACPkgatTEunderMehsanandCirceloffice
2023_BSNL_151655_1
05/EEEA/BSNL/23-24
Open Tender
Electrical Works
Item Rate
365 days
Mehsana
As per NIT
2 documents required · 2 mandatory
₹590
Yes
BSNL
₹11,535
Yes
19 May 2023
13 Apr 2023
11 May 2023
13 Apr 2023
10 May 2023
13 Apr 2023
13 Apr 2023 - 10 May 2023
Amount
SH-I (AMC Part of HPAC)
Comprehensive maintenance of following 7 TR Precision AC Unts for the Different TE / RLU Bldg under the jurisdiction of BSNL ED-I Ahhmedabad as per the details given in the Section -I attached herewith and as per relevant section by deploying the required staff including specialized man power and by arrnaging required spares , tools and plants etc, to keep the service operational up to the standard complete as required. a) 10 X12 TR Precision AC Pkg Units for TE Bldg for MSC Sahibaug, Ahmedabad
c)7 X 7 TR Precision AC Pkg Units for TE Bldg Mehasana
d) 4 X 7TR Precision AC Pkg Units for MSC 1st Floor at TE Vastrapur, Ahmedabad
m) 1 X 7 TR Precision AC Pkg Units for MSC at TE Shahibaug, Ahmedabad.
Sub Head - II (Call Basis - Conventional Pkg. A.C.)
Attending faults with minor material / Service/ Repairing & Chemical cleaning of following capacity conventional / High precision package type AC unit complete with cleaning of condenser coils & evaporator coils by using caustic soda solution & pressurized water spray, combing of fins, removing all dust/dirt, refixing of all loose covers/spares, tightening foundation bolts, electrical connections, cleaning of prefilter & fine filters, adjusting all controls for the performing of desired performance , fixing of all loose shutters/doors with gaskets & nut bolts, cleaning & dedusting of indoor PAC unit & condenser unit complete with etc. as directed by Engg.- In -Charge. a) 7 / 7.5 / 9 TR
Replacement of following accessories in existing PAC units for attending faults of 7/ 7.5 / 9 TR single/Double circuit capacity of approved make i/c pumping down of refrigerant system, fixing, jointing, modification if required, brazing, connection, testing & commissioning complete with dismantling of old accessories etc as required i/c HPSV A/C Unit.(NOTE- The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory) (a)Expansion Valve
(b)Thermostat dial type
(c)Liquid Valve.1/2"
(d)Liquid line filter / Drier 5 /8 " / 3/8 "
(e)Blower Fan motor belt
(f)Pedestal type bearing for blower fan shaft
(g)Capacitor 6 MFD for 1 Phase condenser motor
(h)HP cut out switch manual reset type
(i)HP/LP combined cut out switch
(j)LP cut out switch auto reset type
(k)HP pressure gauge, 50mm dia (0-500 psi)/ with capillary
(l)LP pressure gauge, 50 mm dia(-30-0-0-300 psi) with capillary
(n)Replacement of Brass/GM angle valve 1/4" dia
(o)Replacement of defective / by passed Brass/GM safety valve of condenser receiver unit of size 1/2" & 5/8"
Condenser fan blade suitable for Double circuit Pkg.AC units i.e for 3.75TR.
Condenser fan blade suitable for single circuit Pkg.AC units i.e for 7.5TR.
Rewinding of condenser motor of 0.75 to 1.00 HP capacity suitable for operation on 3 Phase, 415 Volts AC Supply etc. complete as required.
Supplying and Charging fresh refrigerent R-22 / R- 410 including, Nitrogen pressure testing & arresting leakage , vaccumization / dehydrating of entire circuit including pump down the system etc complete as reqd.
Carrying out leak testing of A.C. Package condensor coils , evaporator coils, other parts of the refrigerant circuit with nitrogen gas, brazing the leak points, flushing the system, vaccuumizing, making the system leak proof, supplying and charging the system with R-22 / R-410 refrigerant gas including testing & commissioning etc. complete as reqd.(Cost of gas included in item no 7)
M K AIRCON SYSTEMS PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .