Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-AOC NO 03 4TH CROSS STREET SOURI NAGAR DHARMAPURI PUDUCHERRY 605609 | 605609 | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.1 L+₹4,941 (0.55%)Rejected-Finance NO 42 POINT CARE STREET O K PALAYAM MUDALIARPET PUDUCHERRY 605004 | PUDUCHERRY | PUDUCHERRY | PUDUCHERRY | 605004 | L2 | Rejected-Finance He is 2nd lowest |
Tender Value
₹9.7 L
EMD Value
₹19,340
Closing Date
19 Feb 2020, 11:30 amClosed
Executive Engineer
Office of the Executive Engineer, BRS, PWD, Puducherry
Urgent repair works to the Layer house I, II, Grower House I, II, reconstn. of the compound wall with required plastering, painting, relaying the Mangalore pressed tiles in the Admi Buil at Livestock and Poultry Research and Extn Centre LPREC, Karia
2020_PWDC1_5771_1
No.43/ PW/EE/BRS/2019-20
Open Tender
Civil Works - Buildings
Item Rate
90 days
Puducherrry
Please refer Tender documents.
3 documents required · 3 mandatory
₹525
Payable To Executive Engineer
₹19,340
20 Mar 2020
13 Feb 2020
20 Feb 2020
13 Feb 2020
19 Feb 2020
13 Feb 2020
Amount
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering.- All work upto plinth level -1:4:8 (1 cement:4coarse sand : 8 graded stone aggregate 40mm nominal size)
Cement concrete flooring 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate.
Earthwork in surface excavation not excceding 30cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth upto 50m and lift upto 1.5m , disposed soil to be levelled and neatly dressed - all kinds of soil
Providing non-asbestos high impact polypropylene reinforced cement 6mm thick corrugated sheet (as per IS : 14871) roofing upto any pitch and fixing with pollymer coated J or L hooks, bolts and nuts 8mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc., complete excluding the cost of purlins, rafters and trusses corrugated sheets and including cutting to size and shape wherever required.
Providing and fixing ridges and hips in non-asbestos fibre cement high impact polypropleyene reinforced roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc., complete. Corrugated serrated adjustable ridges.
Dismantling roofing including ridges, hips valleys and gutters etc. and stacking the material within 50m lead of - Asbestos Sheet
Brick work with FPS bricks of class designation 35 in superstructure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:6 (1 cement : 6 coarse sand)
12 mm cement plaster of mix - 1:5 (1 cement : 5 fine sand)
15mm cement plaster on the rough side of single or half brick wall of mix 1:5 (1 cement : 5 fine sand)
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 metres lead - With cement mortar 1:4 (1 cement : 4 fine sand)
Demolishing brick work, manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead - In cement mortar.
Applying one coat of cement primer of approved brand and manufacture on wall surface - Cement primer
Finishing walls with water proofing cement paint of required shade - New work. (Two or more coats applied @ 3.84 kg/10 sqm)
Finishing walls with water proofing cement paint of required shade - Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litres/10 sqm complete including cost of priming coat.
White washing with lime to give on even shade - New work (three or more coats).
Providing and laying pressed clay tiles (as per approved pattern 18mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% intergral water proofing compound laid over a bed of 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
Applying two coats of cement based polymer modified bonding admixture (FOSROC or equivalent ) over the existing RCC members after removing the plastering and cleaning the concrete surfaces and saturated with clean water. The cost including all materials labour charges.
Supplying and fixing of steel grill work of m.s. angles,flats,squares and pipes including cost of welding charges, fixing in position in masonry walls with cement concrete 1:2:4 (1 cement : 2 course sand : 4 graded stone aggregate 12.5mm nnominal size) including one coat of priming coat etc. complete.
Engaging of excavator 60, for removal of accumulated sludge earth mounds waste materials and debries on the BT surface and dismantling the side berms as directed by the Engineer-in-charge.
Engaging of tipper lorry 5 tonnes capacity for disposal of rubbish and unwanted waste materials from side berms as directed by the Engineer-in-charge.
Engaging of Belder for cleaning unwanted materials etc., complete as directed by the Engineer-in-charge. (During day time)
Providing and fixing PVC rigid foam sheet 1mm thick on existing door shutters (Bathroom and WC doors) using synthetic rubber based adhesive
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 m lead - Of area 3 sq. metres and below.
Providing and fixing CP brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 - 15 mm nominal bore.
Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS : 13592 type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion, (i) single socketed pipes. 110mm diameter.
Providing and fixing on wall face unplasticised- PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS : 13592 type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. Bend 87.5deg. 110mm bend.
Providing and fixing on wall face unplasticised- PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS : 13592 type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. Shoe (plain)110mm shoe.
Providing and fixing of 65mm Godrej Navtal lock of 6 levers etc complete
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade - One or more coats on old work.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade - Two or more coats on new work.
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
H EZHILAN
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .