Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹39.9 L+₹2.1 L (5.69%)Rejected-Finance 1 28 NORTH STREET SOUTH VILAYANARAYANAM NANGUNERI TALUK TIRUNELVELI DIST 627 118 | TIRUNELVELI | TIRUNELVELI | TAMIL NADU | 627118 | L2 | Rejected-Finance being higher bid value | |
| 3 | Rejected-Technical ANGALAMMAN KOVIL STREET ULIYANALLORE POST PANAPAKKAM VIA ARAKKONAM TK VELLORE DIST TN 631 052 | ARAKKONAM | VELLORE | TAMIL NADU | 631052 | - | Rejected-Technical The firm has not been enlisted for eligible category i.e. c(i). | |
| 4 | Rejected-Technical CHENNAI | - | Rejected-Technical The firm has not been enlisted for eligible category i.e. c(i). |
Tender Value
Refer Docs
EMD Value
₹73,500
Closing Date
3 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Tirunelveli
GE TIRUNELVELI INS KATTABOMMAN NAVAL BASE POST VIJAYANARAYANAM TIRUNELVELI
GE/TVL/8190
2021_MES_493179_1
GE/TVL/8190
Open Tender
Miscellaneous Works
Item Rate
330 days
Ramnad
As per NIT/ Tender documents
8 documents required · 8 mandatory
₹500
GE Tirunelveli
₹73,500
Yes
12 Feb 2022
8 Dec 2021
5 Jan 2022
8 Dec 2021
3 Jan 2022
22 Dec 2021
8 Dec 2021 - 15 Dec 2021
60 days
Amount
SCHEDULE 'A' PART-I [ E/M SUMMER COOLING APPLIANCE]
Providing comprehensive annual maintenance periodical/preventive maintenance including annual maintenance of cooling appliances ( Split type Air Conditioners, Water coolers, Refrigerators and Deep Freezers) as per manufacturer specification by providing one AC/Refrigeration mechanic including replacement of components as listed in subsequent items here in after. The maintenance of cooling appliances includes the following:- (a) Cleaning of coil unit with dust blower, lubricate the indoor and outdoor fan motor with oil. (b) Cleaning of air filters, indoor unit grills & filters through air blower. (c) Checking and cleaning the drain connection and air filter periodically, washing of coil with ventiklean solution once in a contract period. (d) Check and replace the refrigerent pipe once in a contract period or as and when required. (e) Check and repair the minor electrical fault in incoming supply. (f) Check and replace the water PVC pipe. (g) Replacement of faulty spares/components (h) Carry out the monthly, quarterly and annual maintenance of all cooling applicances of any make & capacity with job card and making the Cooling Appliances functional (Each Job contains 3 Complaints)
Supply only the following new items for 1.5 / 2.00 Ton Capacity Split type AC including testing and commissioning etc complete all as directed.
Capacitor 60 MFD.
Air filters.
Condenser fan motor 1.5 HP with blade set .
Blower fan motor 1.6 HP with blade set. Make:
Blower with circular leaf.
Copper condenser coil unit (for A/C)
Copper cooling coil unit (for A/C)
Indoor motor capacitor 2.5 MFD. Make:
Stainer tube (copper)
Capillary tube (copper)
Non return valve (For gas top up charging)
Remote control suitable for Non inverter model Split AC. Make : LG
Remote control suitable for Non inverter model Split AC. Make : Bluestar
Remote control suitable for Non inverter model Split AC. Make : Daiken
Remote control suitable for Non inverter model Split AC. Make : Universal
Remote control suitable for inverter model Split AC. Make : Bluestar
Remote control suitable for inverter model Split AC. Make : Daiken
PCB board suitable for indoor unit of Non inverter model split AC 1.5/2.0 TR Make : LG
PCB board suitable for indoor unit of Non inverter model split AC 1.5/2.0 TR Make : Bluestar
PCB board suitable for indoor unit of Non inverter model split AC 1.5/2.0 TR Make : Daiken
PCB board suitable for indoor unit of Inverter model split AC 1.5/2.0 TR . Make : LG
PCB board suitable for outdoor unit of Inverter model split AC 1.5/2.0 TR . Make : LG
PCB board suitable for indoor unit of Inverter model split AC 1.5/2.0 TR . Make : Daiken
PCB board suitable for outdoor unit of Inverter model split AC 1.5/2.0 TR . Make : Daiken
Copper pipe of size 1/2" for suction line with foam insulation
Copper pipe of size 1/4" for discharge line with foam insulation
Swing Motor for indoor unit
Outdoor unit stand
Condenser fan motor blade
Indoor Motor blower
Supply and fix PVC insulated unsheathed cables of size 2.5 sqmm 3 core multi-stranded Copper conductor wire suitable for geysers complete all as specified and as directed.
Supply and fix Metal plug top for AC complete all as specified and as directed
Supply only the new following items for for 3.00 Ton Capacity Floor standing /Voltas make Tower AC including testing and commissioning etc complete all as directed.
Air filters.
Condenser fan motor with blade set .
Blower fan motor with blade set.
Blower with circular leaf.
Condenser coil unit (for A/C)
Cooling coil unit (for A/C)
Indoor motor capacitor 2.5 MFD.
Stainer tube (copper)
Capillary tube (copper)
Non return valve (For gas top up charging)
Remote control suitable for Non inverter Tower AC.
PCB board suitable for outdoor unit.
PCB board suitable for indoor unit.
Copper pipe of size 5/8" for suction line with foam insulation
Copper pipe of size 3/8" for discharge line with foam insulation
Swing Motor for indoor unit
Outdoor unit stand
Condenser fan motor blade
Indoor Motor blower
Supply and fix PVC insulated unsheathed cables of size 4 sqmm 5 core multi-stranded Copper conductor wire suitable for geysers complete all as specified and as directed.
Supply and fix Three phase metal plug top complete all as specified and as directed
Supply only the new following items for water cooler 40/80 Litres capacity including testing and commissioning etc complete all as directed.
Relay unit
PVC float valves , high pressure with polythene float and fly nut screwed to iron pipe or ferrule of bore 15 mm.
Thermostat asssembly
Water tap suitable for water cooler.
Starting Capacitor 80-100 MFD
Running capcitor 36 MFD
Condenser fan motor 1.6HP with blade set
Over load protector (OLP)
Supply only new compressor including pumping out oil, cleaning the refrigeration system with CO2 and charging refrigerant gas (M-22/F-22) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning all as directed for the following appliances :-
Split type AC 1.5 Ton capacity. Make: Bluestar or Voltas /LG/Samsung/Panasonic
Split type AC 1.5 Ton capacity. Make: Bluestar or Voltas /LG/Samsung/Panasonic
Water cooler 40/80 Litres capacity . Make: Samsung or Voltas /LG/Bluestar
Floor standing/Tower AC 3 Ton Capacity. Make : Voltas or LG/Bluestar/Samsung
Repair to stabilizer of capacity 4 or 5 KVA capacity by removing the old / burnt transformer and replaced with new transformer complete all as directed.
Repair to stabilizer by removing the old / burnt relay board suitable for Voltage stabilizer of capacity 4 KVA / 5 KVA capacity
M & L Painting complete with super enamel paint of approved colour for water cooler all as specified and directed.
Supply and fix condensed water PVC flexible pipe of standard quality of suitable size fixing with suitable clamps on wall for split type AC of capacity of 1.5/2.0 Ton complete all as specified and as directed.
Supply only R22 /R32 /R410 Gas complete all as specified and directed.
Supply only R134a Gas complete all as specified and directed.
Dismantling and dis connecting carefully the existing split AC 1.5/2.0 Ton capacity after disconnecting the copper pipe and electrical connection, Cleaning the refrigeration system with CO2 and fixing in a new position including, brazing, testing and commissioning complete all as directed for the following cooling appliances :- NOTE : The wt of refrigerent used for filling/top up shall be measured and paid under respective item.
Supply only 2 nos of 1/2" x 3/8" Foam Heat Insulated Pipe Black for Air Conditioner
Material and lobour for making good of surface with sealing the cavity /hole drilled to facilitate tubing, using white cement/POP and cleaning the surface to match with existing surface complete.
Material only for following items for refrigerators/Deep Freezers 320 Litres capacity including testing and commissioning etc complete all as directed.
(a) Relay unit.
(b) Thermostat assembly.
(c) Condenser coil
(d) Freezer for double door refrigerator
Supply only new compressor including pumping out oil, cleaning the refrigeration system with CO2 and charging refrigerant gas providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning all as directed for the following appliances :-
(a) Refrigerators 310/320 litres capacity. Make: Samsung or Voltas /LG/Bluestar
(b) Deep Freezers 320 litres capacity. Make: Samsung or Voltas /LG/Bluestar
M & L Painting complete with super enamel paint of approved colour for Refrigerator/ water cooler all as specified and directed.
SCHEDULE 'A' PART-II [ E/M INTERNAL WIRING]
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc., removing materials to store for keeping in safe custody for taking credit and making good disturbed surfaces of walls, floors etc.
M&L for Point wiring with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade FRLS single core drawn into and including non-metallic rigid PVC conduit of 20 mm dia/ PVC Casing capping along with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade FRLS as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof with and including 1.6 mm thick MS sheet fabricated terminal boxes flush mounted for mounting the switches, sockets, fan regulator etc as required with 3mm thick laminated hylum sheet top cover all as specified and directed for :-
(a) One light point controlled by one switch
(b) One fan point controlled by one regulator / switch.
(c)One 3 pin socket outlet 5 amps socket on independent board
(d) One 3 pin socket outlet 5 amps socket on Same Board board
(e) One light point controlled by two Nos of two way switches
(f) One bell/buzzer point controlled by one push button
All description as per item No. 25 here-in-before but with 4 sqmm cable for one 3 pin socket outlet 15 Amps on independent board with 4 sqmm cable as earthing conductor.
S&F in repair Socket outlet 2 in 1, 3 pin, 5A complete all as specified and as directed.
Supply and fix in repair switch piano flush type single pole one way 5 A 240 Volts complete all as specified and as directed including taking down old unserviceable switches complete all as specified and as directed.
Supply and fix in repair switch flush type single pole two way 5 A 240 Volts complete all as specified and as directed.
Supply and fix in repair switch Socket combination 2 in 1, 5 Amps Flush type 240 Volts complete all as specified and as directed.
Supply and fix in repair switch Socket combination 5 Amps / 16 amps, 5 in 1 flush type 240 Volts complete all as specified and as directed.
Supply and fix in repair ceiling rose 3 ways PVC / Polycarbonate, isolated body complete all as specified and as directed.
Supply and fix in repair Call bell, ding-dong, suitable for working on 230 volts AC supply, single pole, complete all as specified and as directed.
Supply and fix in repair Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and as directed.
Supply and fix in repair Bell push flush type 5 A 240 Volts complete all as specified and as directed.
S/ F in repair Modular switch 1 way 5A, 1 Module including taking down old unserviceable switch and removing the material for taking credit complete all as specified and as directed.
S / F in repair Modular switch 1 way 16A, 1 Module including taking down old unserviceable switch and removing the material for taking credit complete all as specified and as directed.
S/ F in repair Modular bell push ,5 A, 1 Module including taking down old unserviceable bell push and removing the material for taking credit complete all as specified and as directed.
S / F in repair Modular Socket 5A-2/3 pin combined 2 Module. including taking down old unserviceable socket and removing the material for taking credit complete all as specified and as directed.
S / F in repair Modular Socket 5A / 15A - 2 / 3 pin combined 2 Module. including taking down old unserviceable socket and removing the material for taking credit complete all as specified and directed.
S/F in repair Modular fan Regulator Step type , 2 Module including taking down old unserviceable fan regulator and removing the material for taking credit complete all as specified and as directed.
Supply and fix in repair Modular switch 5 Amps two way flush type including taking down old unserviceable modular switch and removing the material for taking credit complete all as specified and directed.
Supply & fix in repair Modular White cover plate with frame, 1 Module including taking down old unserviceable modular cover plate and removing the material for taking credit complete all as specified and directed.
Supply & fix in repair Modular White cover plate with frame, 2 Module including taking down old unserviceable modular cover plate and removing the material for taking credit complete all as specified and directed.
Supply & fix in repair Modular White cover plate with frame, 3 Module including taking down old unserviceable modular cover plate and removing the material for taking credit complete all as specified and directed.
Supply & fix in repair Modular White cover plate with frame, 4 Module including taking down old unserviceable modular cover plate and removing the material for taking credit complete all as specified and directed.
Supply & fix in repair Modular White cover plate with frame, 6 Module including taking down old unserviceable modular cover plate and removing the material for taking credit complete all as specified and directed.
Supply & fix in repair Modular White cover plate with frame, 8 Module including taking down old unserviceable modular cover plate and removing the material for taking credit complete all as specified and directed.
Supply and fix in repair Modular metal flush box 1/2 module including taking down old unserviceable metal box removing the material for taking credit and making good the disturbed surface of wall complete all as specified and directed.
Supply and fix in repair Modular metal flush box 3 module including taking down old unserviceable metal box removing the material for taking credit and making good the disturbed surface of wall complete all as specified and directed.
Supply & fix in repair Modular Metal flush Box 4 Module including taking down old unserviceable metal box removing the material for taking credit and making good the disturbed surface of wall complete all as specified and directed.
Supply & fix in repair Modular Metal flush Box 6 Module including taking down old unserviceable metal box removing the material for taking credit and making good the disturbed surface of wall complete all as specified and directed.
Supply & fix in repair Modular Metal flush Box 8 Module including taking down old unserviceable metal box removing the material for taking credit and making good the disturbed surface of wall complete all as specified and directed.
Supply and fix in repair 3mm thick laminated sheet top cover on switch boards including cutting, fixing and scwering etc including taking down old unserviceable hylum sheet, removing the material for taking credit and making good the disturbed surface of wall complete all as specified and directed. all as specified and directed at site.
Supply and fix in repair flushed to wall 1.6 mm thick Galvanised Iron sheet fabricated terminals box of following sizes and dismantling corroded metal box from wall, removing the material for taking credit and making good the disturbed surface of wall including plastering the sides complete all as specified and directed.:-
Box Size- 79 mm x 75 mm x 46 mm (1 or 2 module)
Box Size- 79 mm x 99 mm x 46 mm (3 module)
Box Size- 79 mm x 135 mm x 52 mm (4 module )
Box Size- 79 mm x 207 mm x 52 mm (6 module )
Box Size- 79 mm x 230 mm x 52 mm (8 module )
Box Size- 132 mm x 135 mm x 56 mm (8 module )
Supply & fix in repair PVC casing caping of size 25 mm ISI marked on wall/roof/ceiling work etc with all accessories and drawing any type of cables through caping casing all as directed at site including and making good the disturbed surface of wall complete all as specified and directed. Note: - Drawing out existing cable of any size , keeping it in safe custody ,taking down the old unserviceable PVC casing /caping , removing the pipe for taking credit are measured as seperate item.
Supply and fix in repair PVC conduit of size 25 mm ISI marked on wall/roof/ceiling work etc with all accessories and drawing any type of cables through PVC conduit all as directed at site including making good the disturbed surface of wall complete all as specified and directed. Note: - Drawing out existing cable of any size , keeping it in safe custody ,taking down the old unserviceable PVC Pipe, removing the pipe for taking credit are measured as seperate item.
Supply and fix in repair PVC conduit of size 32 mm ISI marked on wall/roof/ceiling work etc with all accessories and drawing any type of cables through PVC conduit all as directed at site including making good the disturbed surface of wall complete all as specified and directed. Note: - Drawing out existing cable of any size , keeping it in safe custody ,taking down the old unserviceable PVC Pipe, removing the pipe for taking credit are measured as seperate item.
Supply and fix in repair PVC conduit of size 40 mm ISI marked on wall/roof/ceiling work etc with all accessories and drawing any type of cables through PVC conduit all as directed at site including making good the disturbed surface of wall complete all as specified and directed. Note: - Drawing out existing cable of any size , keeping it in safe custody ,taking down the old unserviceable PVC Pipe, removing the pipe for taking credit are measured as seperate item.
Removing serviceable wiring of any size from conduit/batten/casing/caping on surface of wall, ceiling and keeping in safe custody for resuse and redrawing through PVC Conduit / PVC Caping casing complete all as specified and directed.
Taking down unserviceable PVC conduit / casing /caping of any size and removing the material for taking credit complete all as specified and directed.
Taking down carefully old unserviceable submain wiring with aluminum /copper conductor cable 4/6/10/16 Sqmm in PVC conduit complete removing the materials and taken as credit and making good the disturbed surface of wall / floor etc.
M&L for Sub main wiring with two run single core 4 sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade FRLS and one run of 4 sq mm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 25 mm dia/PVC casing capping 25 mm including conduit accessories all as specified and directed. Note: Three runs of 4 Sqmm cable and one run of 25mm conduit / casing capping will be measured as one unit length.
M&L for Sub main wiring with two run single core 6 sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade FRLS and one run of 6 sq mm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 32 mm dia/PVC casing capping 25 mm including conduit accessories all as specified and directed. Note: Three runs of 6 Sqmm cable and one run of 32mmconduit / casing capping will be measured as one unit length.
M&L for Sub main wiring with four runs single core 4sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade FRLS and two runs of 4 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metalic rigid PVC conduit, 25mm dia/PVC casing caping 32 mm and conduit accessories concealed/surface of wall/roof/ceiling etc complete all as specified and directed. Note: Four runs of 4sqmm and two runs of 4 sqmm cable and one run of 25mm dia conduit/casing capping shall be measured as one unit length.
M&L for Sub main wiring with four runs single core 6 sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade FRLS and one run of 6 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 32 mm dia/PVC casing capping 32 mm including conduit accessories all as specified and directed. Note: five runs of 6 Sqmm cable and one run of 32 mm conduit / casing capping will be measured as one unit length.
Supply and fix in repair Sheet metal enclousers with socket plug top and MCB SPN 20A, 240 volts, with a two pin and earth plug socket complete with one single MCB 20 Amps, 240 volts (for AC ) including taking down old unserviceable old unserviceable Sheet metal enclousers with socket plug top complete all as specified and directed
Supply and fix in repair sheet metal enclosure powder coated double door for Distribution Board, SPN 4 way DB ,240 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, dismantling from position unserviceable DBs for taking into credit complete all as specified and as directed.
Supply and fix in repair sheet metal enclosure powder coated double door for Distribution Board, SPN 8 way DB with 200 A bus bar ,240 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, dismantling from position unserviceable DBs for taking into credit complete all as specified and as directed.
Supply and fix in repair sheet metal enclosure powder coated double door for Distribution Board, SPN 12 way DB with 200 A bus bar ,240 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, dismantling from position unserviceable DBs for taking into credit complete all as specified and as directed.
Supply and fix in repair sheet metal enclosure powder coated double door for Distribution Board, TPN 4 way DB ,415 V with Detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, dismantling from position unserviceable DBs complete for taking into credit all as specified and as directed.
Supply and fix in repair sheet metal enclosure powder coated double door for Distribution Board, TPN 8 way DB ,415 V with Detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, dismantling from position unserviceable DBs complete for taking into credit all as specified and as directed.
Supply and fix in repair sheet metal enclosure powder coated double door for Distribution Board, TPN 12 way DB ,415 V with Detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, dismantling from position unserviceable DBs complete for taking into credit all as specified and as directed.
Supply and fix in repair sheet metal enclosure powder coated double door for Distribution Board, VTPN 4 way DB with Degree of Protection IP 54 including , Disconnecting electric connections, dismantling from position unserviceable DBs for taking into credit complete all as specified and as directed.
Supply and fix in repair sheet metal enclosure powder coated double door for Distribution Board, VTPN 8 way DB with Degree of Protection IP 54 including , Disconnecting electric connections, dismantling from position unserviceable DBs for taking into credit complete all as specified and as directed.
Supply and fix in repair MCB SP 5 A to 32 A , B curve, 10 kA including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix in repair MCB SP 40 Amps , B curve 10 kA including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix in repair MCB SPN 32 Amps , C curve 10 kA including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix in repair MCB SPN 40 A- 63Amps , C curve 10 kA including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix in repair MCB TP 25A - 63 A , C curve 10 kA including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix in repair MCB TPN 16 A- 32 Amps , C curve 10 kA including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix in repair MCB TPN 40A- 100 A , C curve 10 kA including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
M & L for earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 32x6mm GI strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 connected to earthing test point,including 20 mm GI pipe (Medium grade) for watering and 40 mm GI pipe (Medium grade) for protection of earth strip and etc.. including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wiremesh ,funnel,lugs and charcoal,salt etc all as applicable including taking down old unserviceable earthing complete for taking into credit all as specified and as directed by the Engineer-in-Charge. Note:-(i) The rates quoted is inclusive of 32x6mm GI strip earth conductor upto a length of 7.5m from the earth pit.
Supply and lay earth continuity conductor or main earting lead fixed to wall on batten or recess or burried in ground or drawn in conduit / conduit pipe or fixed to poles or any other indicted situation for loop earthing etc of galvanised steel earth strip of size 32 X 6mm including taking down old unserviceable earth strip complete for taking into credit complete all as specified and as directed by the Engineer-in-Charge
M & L for earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised steel earth wire 4mm dia as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 connected to earthing test point,including 20 mm GI pipe (Medium grade) for watering and 40 mm GI pipe (Medium grade) for protection of earth strip and etc.. including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wiremesh ,funnel,lugs and charcoal,salt etc all as applicable including taking down old unserviceable earthing complete for taking into credit complete all as specified and as directed by the Engineer-in-Charge. Note:-(i) The rates quoted is inclusive of 32x6mm GI strip earth conductor upto a length of 7.5m from the earth pit.
Supply and lay earth continuity conductor or main earting lead fixed to wall on batten or recess or burried in ground or drawn in conduit / conduit pipe or fixed to poles or any other indicted situation for loop earthing etc of galvanised steel earth wire 4mm dia including taking down old unserviceable GI earth wire complete all as specified and as directed.
Supply and fix in repair Lightning Protection Single point air termination aluminum rod 12mm dia 300mm long with base plate including taking down old unserviceable aluminium rod for taking into credit complete all as specified and as directed by the Engineer-in-Charge .
Supply and fix in repair Test point terminal box made out of Gun metal or Phosphorous bronze of size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex head screws including taking down old unserviceable test point terminal box for taking into credit complete all as specified and as directed by the Engineer-in-Charge .
Supply and fix in repair Aluminium strip of 25x 3.15mm fixed with screws/ clamps / insulators for roof conductors and down conductors above ground level complete including taking down old unserviceable Aluminium strip for taking into credit complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix in repair MCCB 4 pole 415 volts , 100 Amps, with rupturing capacity 16 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge .
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 125 amps, with rupturing capacity 16 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge .
Material and labour for Painting the DB Boxes as required at site after scraping out completely the old paint with one coat of redoxide primer and two coats of synthetic enammel paint including carrying out minor welding works if reqired as directed by the Engineer in charge NOTE:Colour of paint shall be decided by the Engineer-in-charge.
Supply and fix in repair ON Load Change over switch 415V in shet metal enclosures 4 pole 125 Amps including taking down old unserviceable ON Load Change over switch for taking into credit complete all as specified and as directed
Supply and fix in repair ON Load Change over switch 415V in shet metal enclosures 4 pole 200 Amps including taking down old unserviceable ON Load Change over switch for taking into credit complete all as specified and as directed
Material and labour for Writing letters (Block.Roman, Italic or Indian) with thick paint ,stand out boldly and solidly without showing signs of brush marks, or by Stickering , upto 10 cm height and painting with contrasting colour in the background of letter complete as directed. NOTE:Colour of paint/ stickering shall be decided by the Engg-in-charge.
Demolition, Cement concrete (unreinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
M & L for 85 mm thick cement concrete 1:2:4 type B-1, using 20mm graded aggregate for making good the disturbed road surface after laying of pipe line over returned filled and compacted earth surface to match with existing road level complete all as specified and as directed.
Supply and fix in repairs plug top 3 pin 5 A including removing old unserviceable item for taking into credit complete all as specified and directed
Supply and fix in repairs plug top 3 pin 15 A including removing old unserviceable item for taking into credit complete all as specified and directed
Supply and fix in repairs copper tubular terminal socket of following size complete including crimping it properly all as specified and directed :-
Size 2.5 sq.mm
Size 4 sq.mm
Size 6 sq.mm
Size 10 sq.mm
Supply and fix in repairs ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including taking down unserviceable fan complete all as specified and directed
Supply and fix in repair exhaust fan in repairs, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers including taking down unserviceable fan complete all as specified and directed
Supply and fix in repair exhaust fan in repairs, steel body AC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers including taking down unserviceable fan complete all as specified and directed
Supply and fix in repair Flame proof Exhaust fan in repairs 300mm sweep, heavy duty , Rust proof body and blades, double ball bearing with noisless operation, 1400 RPM complete with Wall Mounting with M.S. Supporting channel and M.S. mesh as a guard. including making suitable opening at suitable height,and provision of nuts and bolts on the wall for fixing the exhaust fan fan complete all as specefied and as directed .
Supply and fix in repair wall mounted fan in repairs 450 mm with Powder Coated Guard with Aluminum Die Casting Blade, minimum Three speeds control,vertical adjustment from 22° to 45°, 1440 RPM.. 90 degree oscillation . Make: ALMONARD. Model: Wall Fan 18" M-II.
Supply and fix in repairs electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc. including connecting Heavy Stainless Steel (SS) braided hoses (Flexible Hoses) of required length having a minimum pressure rating of 8 bar and compatible for hot water applications including making end connections for water inlet/ outlet from/to water heater or to the discharge line
Supply and fix in repair in repairs Lamp holder PVC / Polycarbonate for LED bulb 18 W, isolated body including taking down old unserviceable lamp holders and removing the material for taking credit complete all as specified and directed.
Supply and fix in repairing in repairs LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. and taking down old U/S fittings for taking into credit complete all as specified and directed Make :Crompton/ Bajaj / Wipro / Philips/Havells
S & F LED light fitting in repairs 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed including taking down old U/S fittings for taking into credit . Make :Crompton/ Bajaj / Philips /Wipro/Havells
Supply and fix in repairing in repairs LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete including taking down old U/S fittings for taking into credit. Make :Crompton/ Bajaj /Philips /Wipro/Havells
Supply and fix in repairs recessed mounting 2 ft x 2 ft LED luminaire 36W or nearest higher wattage 6500 K suitable for amtrong/grid ceiling with super bright LED etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including taking down old U/S fittings for taking into credit . Make : Crompton / Philips/ Bajaj/ WIpro/Havells.
Supply and fix in repairs of LED 15W light fitting round/square recess mounting downlighter fitting including taking down old U/S fittings for taking into credit and minor alteration to false ceiling as required at site and making the surface good complete all as specified and directed Make :Bajaj / Philips/ Crompton/Wipro/Havells.
Supply and fix in repairs Electronic Ballast 36 watts /40Watts including taking down old unserviceable ballast and removing the material for taking credit complete all as specified and as directed.
Supply and fix in repairs Electronic Ballast 28 Watts including taking down old unserviceable ballast and removing the material for taking credit complete all as specified and as directed.
Supply and fix in repair 2x28 watts electronic ballast suitable for FTL fitting including removing old one complete all as specified and directed
Supply and fix in repair 2x36 watts electronic ballast suitable for FTL fitting including removing old one complete all as specified and directed
Supply and fix in repair tube rod LED, 15 watts T5 double side connection, 4' long after taking out old burnt choke and fluorescent tube complete all as specified and directed. Make : Wipro/Crompton/ Bajaj/ Phlips/Havells.
Supply and fix in repair tube rod LED, 20 watts T8 double side connection, 4' long after taking out old burnt choke and fluorescent tube complete all as specified and directed. Make : Crompton/Bajaj/Phlips/Wipro/Havells
Supply and hang in repairs vertical mounting integral highbay/ mediumbay in hanger ceiling at 10 meter height LED IP65 luminaire, 100 watts ,efficacy upto 100Lm/W , IP65.Surge protection of internal 4kV and external 4kV complete all as specified and directed Make: Crompton/Bajaj/Phlips/Wipro/Havells
Supply and fix in repair LED bulb 16 watts complete all as specified and as directed.
S&F in repair energy saving LED security light fittings, 30 Watts or nearest higher wattage, with in-built electronic driver, IP 66 class of protection with versatile pressure die-cast aluminium body, toughened glass cover with silicon gaskets and energy efficient LED and connecting up light fitting with copper conductor cable of suitable size from junction box to connector block including all accessories and dismantling of old unserviceable fitting for taking into credit complete all as specified and as directed. Make:Crompton/Philips/Bajaj/ Wipro/Havells
Supply and fix in repair LED light fitting 2x 16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size including all accessories and dismantling of old unserviceable fitting for taking into credit complete all as specified and as directed. Make:Crompton / Philips/Bajaj/ Wipro/Havells
sri manikandan enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .