Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-Finance NEAR SANSKAR SCHOOL PRABHAKAR NAGAR GAMBHIRIYA MAKRONIYA SAGAR | VIDISHA | MADHYA PRADESH | 464240 | L1 | Accepted-Finance Rate quoted is lowest | |
| 2 | L2₹8.8 L+₹1.0 L (13.5%)Accepted-Finance 28 SECOND FLOOR OKHLA INDUSTRIAL ESTATE PHASE 3 NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | L2 | Accepted-Finance Rate quoted is highest | |
| 3 | Not Admitted-Fee/PreQual/Technical 58 KAILASHPURAM GOVINDPURAM GAZIABAD | GHAZIABAD | UTTAR PRADESH | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | MTEKPRO TECHNOLOGIES PVT LTD L2 | Laxmi Associates L1 |
|---|---|---|---|---|---|
| 1.00Partial Discharge Test of various 400KV, 220KV & 132KV Current Transformer. | |||||
| 2.00Partial Discharge Test by both EHF (Extra High Frequency) and HF (High Frequency) methods with help of duly calibrated test kit. The works also includes the cost of carriage and operations of test kit including preparation and submission of test result in specified formats after the completion of tests. The test results should clearly mention the health of CTs and suggestion for action taken regarding the same at various 400KV, 220KV and 132KV Substations under ETC Sultanpur. | |||||
| 2.01 | 132KV CT | 364 | Nos. | 985 ₹3,58,540 Lowest | 1,100 ₹4,00,400 |
| 2.02 | 245KV CT | 97 | Nos. | 985 ₹95,545 Lowest | 1,100 ₹1,06,700 |
| 2.03 | 400KV CT | 24 | Nos. | 985 ₹23,640 Lowest | 1,100 ₹26,400 |
| 3.00Capacitance and TAN Delta Measurement & IR Value | |||||
| 4.00Testing of CTs with the help of duly calibrated test kit to be arranged by the contractor including the cost of carriage and operation of test kit including preparation and submission of test results in specified formats after the completions of tests. The tests shall include capacitance, TAN Delta & IP value measurements (To be conducted by duly calibrated test kit). The work shall include the cost of carriage of test kit, manpower involved in testing and submission of test reports in specified formats. | |||||
| 4.01 | 132KV CT | 111 | Nos. | 2,400 ₹2,66,400 | 1,445 ₹1,60,395 Lowest |
| 4.02 | 245KV CT | 33 | Nos. | 2,400 ₹79,200 | 1,445 ₹47,685 Lowest |
| 4.03 | 400KV CT | 24 | Nos. | 2,400 ₹57,600 | 1,445 ₹34,680 Lowest |
Tender Value
₹10.8 L
EMD Value
₹11,000
Closing Date
16 Oct 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
SE ETC Sultanpur 400KV S/S Campus Payagipur Sultanpur
PARTIAL DISCHARGE TEST AND TAN DELTA TESTING OF VARIOUS 400/245/145KV CTs INSTALLED AT 400/220/132KV SUB STATIONS UNDER ETC, SULTANPUR
2025_UPTCL_1078807_1
S.T. T.No. 24/ETCS/2025-26
Open Tender
Electrical Works
Item Rate
30 days
Sultanpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
SE ETC Sultanpur
₹11,000
29 Oct 2025
30 Sept 2025
16 Oct 2025
30 Sept 2025
16 Oct 2025
30 Sept 2025
Amount
Partial Discharge Test of various 400KV, 220KV & 132KV Current Transformer.
Partial Discharge Test by both EHF (Extra High Frequency) and HF (High Frequency) methods with help of duly calibrated test kit. The works also includes the cost of carriage and operations of test kit including preparation and submission of test result in specified formats after the completion of tests. The test results should clearly mention the health of CTs and suggestion for action taken regarding the same at various 400KV, 220KV and 132KV Substations under ETC Sultanpur.
Capacitance and TAN Delta Measurement & IR Value
Testing of CTs with the help of duly calibrated test kit to be arranged by the contractor including the cost of carriage and operation of test kit including preparation and submission of test results in specified formats after the completions of tests. The tests shall include capacitance, TAN Delta & IP value measurements (To be conducted by duly calibrated test kit). The work shall include the cost of carriage of test kit, manpower involved in testing and submission of test reports in specified formats.
MTEKPRO TECHNOLOGIES PVT LTD (BID ID -5607599)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .