| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 LAccepted-AOC | L1 | Accepted-AOC 1 | |
| 2 | L2₹39.0 L+₹51,694 (1.34%)Rejected-AOC 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L2 | Rejected-AOC Not L1 | |
| 3 | L3₹39.2 L+₹68,578 (1.78%)Rejected-AOC B 33 171 PATEL NAGAR GURUDASPUR ROAD PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-AOC Not L1 | |
| 4 | L4₹39.2 L+₹71,238 (1.85%)Rejected-AOC OPP MINI ZOO HADDO SOUTH ANDAMAN 744 102 | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744102 | L4 | Rejected-AOC Not L1 | |
| 5 | L5₹39.5 L+₹99,506 (2.59%)Rejected-AOC | L5 | Rejected-AOC Not L1 |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
22 Mar 2021, 6:00 pmClosed
GE Brichgunj
Garrison Engineer Birchgunj Janglighat (PO) port Blair
SPECIAL REPAIRS REPLACEMENT OF BER AIR CONDITIONERS AND SUMMER APPLIANCES AT AF STATION AND BRICHGUNJ MIL STN UNDER GE BRICHGUNJ PORT BLAIR
2021_MES_427519_1
GEBG8111A
Open Tender
Miscellaneous Works
Item Rate
180 days
Brichgunj
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
BRICHGUNJ
₹28,000
Yes
31 Mar 2021
3 Mar 2021
24 Mar 2021
3 Mar 2021
22 Mar 2021
17 Mar 2021
Amount
M & L for sub main wiring complete with two runs of 2.5 Sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and capping and all accessories fixed to wall/ roofs/ floors etc with one run of 2.5 sqmm FRLS single core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed by Engineer-in-Charge. Note : (1) Two runs of cable one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
S & F sheet metal enclosure with industrial type socket with plug top and earth plug and socket complete with one single pole MCB 20 Amps 240 voltsd including taking out old MCB and plug socket complete as specified and as directed Make:- Havells/Legrand/MDS
Supply, install, commissioning and testing split type air conditioner of nominal capacity 1.5 TR 5 star (Cooling mode, inverter type, withstand in any climatic condition and delever precision cooling upto 0.1C with the option of cool with dual rotor invertor compressor and copper compressor , suitable for working on 230 volts, single phase, 50HZ supply, complete including cutting of wall, providing stand for out door unit and making good disturbed surface of wall etc and remote operation complete all as specified and directed. Make : Daikin/Hitachi/Blue star/LG/Samsung/ Carrier Note :-Rate are included in quoted by contractor for following items are as under :- (a) Fixing the cooling unit with grouting nuts, cutting groove to wall for gas pipe and water drainage pipe. (b) S & F PVC pipe 15/20 mm dia transparent flexible heavy duty for water drainage pipe of required length at site. (c) Insulation of both the copper pipes with insulating material and covering the complete pipe with PVC casing and caping of size 75x75 mm / reqd size for mechanical protection of copper pipe complete. (d) Charging of correct qty of refrigerant gas after necessary brazing/fixing of both the outdoor/indoor unit and testing complete on load to obtain 18 degree celcious temperature at specified Amps. (e) All other connected civil work such as stand/shed including painting and PCC works etc and other misc work required for installation of split AC for proper functioning as directed by EIC.
S & F cutting, bent to shape copper pipe of appropriate size from outdoor unit to indoor unit of split type AC of any capacity with cutting holes into wall/floor fixing with clamp on wall/ceiling etc including brazing the copper pipe fixing union including making good disturbed surfaces.Insulation of the copper pipes with insulating material and covering the complete pipe with PVC casing and caping of size 20/25 mm/reqd size for mechanical protection of copper pipe complete all as specified and directed by Engineer in Charge
S&F water cooler, electric driven, single phase, having approx storage capacity of 80 litre and nominal cooling capacity 40 litre/hour,as per VOLTAS CAT PART NO - VOLTAS WC FS 40/80 NP R134a or equivalent model of Carrier/Blue star/Usha complete all as spcified and directed by Engineer-in-Charge.
S & F 210 ltr Single door hard top chest freezer grey of Voltas Cat part no - VOLTAS CF HT 210SD X GREY or equivalent Carrier/Blue star/Usha all as specified and directed
S & F refrigerator 360 ltrs double door smart inverter compressor door cooling smart diagnosis auto smart connect, 2star Make: LG model No GL-S402RDSY or equivalent model of Samsung/Whirlpool complete all as spcified and directed
Supply, install, test and commissioning of networkable analogue addressable type fire alarm control panel having 1 Loop Expandable upto 4 Loop with min 1500 Character / 240X64 / 5.5” graphic LCD display. The panel should be equipped with sufficient numbers of loop with 10% spare capacity, with each networkable intelligent fire alarm Control Panel having SLC with capacity of min 120 detectors/devices per loop with key pad, dual flash-based microprocessor technology, inbuilt USB Port for upload and down load the configuration tools, RS232 serial port for direct PC or modem connection, inbuilt NAC's, min 20 programmable Zonal LEDs and operates on 240V AC + 10% with 50 Hz with built in charger. The panel shall have fire, fault relays, Option for BMS integration MODBUS/ BACKNET, graphical software for provision of TCP/ IP modules, Remote Access, provision of both class 'A' and class 'B' wiring in the SLC circuit, user friendly with communication facility to monitor & control the FACPs from a single window. The panel shall be suitable for minimum of 5000 event record facility, event fetch from FACP facility and the single panel shall be suitable for min 2000 fire zones and 200 Panels/ Nodes in one network with all other accessories required to successfully run the system. (The System cost shall be included of all necessary cards, modules, Panel enclosure, CPU and associated accessories to complete the system design). 1 Loop Expandable upto 4 Loop Make:Godrej/Apollo/Schneider
Supply, install, test and commissioning of Analogue addressable Heat Detector Make:Godrej/Apollo/Schneider
Supply, install, test and commissioning of Analogue addressable Optical Smoke Detector with inbuilt isolator having Intelligent base, It shall have multiple modes with min five different sensitivity adjustment from 1.4%/m to 2.4%/ft or better and to be possible to configure the detector to work in any of the modes to configure the detector to work in any of the modes from the fire alarm panel. 360° Visible tri colour led for Normal, Fault and alarm condition, addressing shall be by means of Soft addressing or dip switches or decade switches, or suitable punched cards. It shall have Compensation to drift and transient rejection, It shall be possible to insert and remove detectors by a single push twist movement, base shall have special locking tool feature to prevent loosening of detector on its own.Make:Godrej/Apollo/Schneider
Supply, install, test and commissioning of Analogue addressable Dual Action (PUSH DOWN / PULL PUSH Type) Manual Call Point (Resettable Type) with inbuilt isolator and LED indicator, to be supplied with Junction Box, Glands and other mounting accessories for proper installation. Make:Godrej/Apollo/Schneider
Supply, Installation, Testing & Commissioning of Analogue Addressable Loop Powered Sounder & Visual Strobe with inbuilt isolator and having Min 10 distinct sound patterns/ multitone to indicate Exit doors and direct occupants for safe and fast evacuation variable output starting from 1Hz Frequency flash rate designed for IP65 requirements to be supplied with Junction Box, Glands and other mounting accessories for proper installation. (Wiring as per NFPA Class X (Previously style 7). For Detectors/Device without inbuilt isolator. Fault Isolator or Isolator base to be provided with each detector/device). Make:Godrej/Apollo/Schneider
Supply, Installation, Testing & Commissioning of 1.5 sqmm 2 core PVC insulated sheathed ISI marked FRLS copper conductor multi stranded 1100 volt grade cableMake: Kalinga/ Polycab/Gloster/National/Finolex/Havells
S&F rigid non- metallic concealed PVC conduit of size 25mm dia inclusive of all tees, bends, elbow, reducers, bell mouth tube ends and fixing accessories such as couplers. locknuts, saddles, pipe hook etc over the surface/recess complete all as specified and directed
M & L for sub main wiring complete with two runs of 4 Sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessoried fixed to wall/ roofs/ floors etc with one run of 4 sqmm FRLS single core multistranded copper conductor as earth continuity conductor, co,plete all as specified and as directed by Engineer- in-Charge. Note : (1) Two runs of cable one run of conduit & one run of earth contiuity conductor shall be measured as one running metre.
S & F sheet metal enclosure with industrial type socket with plug top and earth plug and socket complete with one single pole MCB 20 Amps 240 volts co,kplete as specified and as directed. Make:- Havells/ Legrand/ MDS
S & F MCB SP 40 Amps 230 V all as specified and as directed
Supply, install, commissioning and testing split type air conditioner of nominal capacity 2 TR (Cooling mode, inverter type, withstand in any climatic condition and delever precision cooling upto 0.1 C with the option of cool with dual rotor invertor compressor and copper compressor, suitable for workingl on 230 volts, single phase, 50 Hz supply , complete including cutting of wall , providing stand for out door unit and making good distrubed surface of wall etc and remote operation complete all as sowcified and directed. Make:- Hitachi/ Blue star/ LG/ Samsung) Note :- Quoted rate by the contractor shall be included for following items :- (a) Fixing the cooling unit with grouting nuts, cutting groove to wall for gas pipe and water drainage pipe. (b) S & F PVC pipe 15/20 mm dia transparent flexible haevy duty for water drainage pipe of required length at site. (c) Insulation of both the copper pipes with insulating materiall and covering the complete pipe with PVC casing and caping of size 75x75
S & F cutting, bent to shape copper pipe of appropriate size from outdoor unit to infoor unit of split type AC of any capacity with cutting holes into wall/ floor fixing with clamp on wall/ ceiling etc including brazing the copper pipe fixing union including making good disturbed surfaces, Insulation of the copper pipes with insulating material and covering the complete pipe with PVC casing and caping of sizw 20/25 mm/reqd size for mechanical protection of copper pipe complete all as specified and directed
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V TO 250 V with output voltage stabilized at 230 V with acuracy of ± 2.5% and of capacity 5 KVA all as specified and as directed Make: V guard/ Vinitec / AE
Tropical Refrigeration
KAPOOR AUTOMOBILES
PSS ELECTRICAL WORKS
SRI HARSHITA ELECTRICALS
M/s Karbhagam Sales Agency
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .