Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 176 PHASE II HSIIDC KUNDI SONEPAT HR | SONEPAT | SONEPAT | HARYANA | 131028 | Admitted-Finance |
| 2 | Admitted-Finance 51 45 KAMARAJ NAGAR POST METTUR DAM 635456 TAMIL NADU | METTUR DAM | SALEM | TAMIL NADU | 635456 | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical The bidder not fullfil the QR |
Tender Value
₹7.4 L
Closing Date
23 Nov 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CE(CTPP)
ADM Building, Motipura Chowki, chhabra
Fenner make or its equivalent couplings and sheave pulleys for CHP system
2021_RRVUN_245244_1
3162/2021-22(MM)
Open Tender
Machineries
Item Wise
120 days
CTPP, RVUNL, Chhabra
As per uploaded our tender documents
2 documents required · 2 mandatory
₹236
Yes
Accounts Officer CTPP Chhabra
Exempted
15 Mar 2022
8 Nov 2021
23 Nov 2021
8 Nov 2021
23 Nov 2021
8 Nov 2021
180 days
Fenner make or its equivalent Finished bore Geared Coupling Type & Size FGC-4 for BCN-12/2,BCN-12A/2, BCN-13/2,BCN-11/2,BCN-2A/2,2B/2 Bore size & key way detail- ID-65/18X4 ID-65/18X4
Fenner make or its equivalent Finished bore Geared Coupling Type & Size FGC-5,for BCN-1/2,BCN2/2, BCN-8/2,BCN-4C/2/,4D/2 .4E/2,4F/2 Bore size & key way detail-ID-90/25X5.4,ID-90/25X5.4
Fenner make or its equivalent Finished bore Geared Coupling Type & Size FGC-7 for 4A/2,4B/2, BCN-7A/2,7B/2,BCN-11B,BCN-9/2 Bore size & key way detail- ID-110/28X6.4 , ID- 110/28X6.4
Fenner make or its equivalent Finished bore Geared Coupling Type & Size FGC-8 for BCN-5A/2,5B/2,3A/2 ,3B/2,6A/2,6B/2 Bore size & key way detail- ID-130/32X7.4 , ID-130/32X7.4
Fenner make or its equivalent Pilot bore resilient coupling, type: FRC-4Z
Spring Set for Fenner make or its equivalent resilient coupling, type: FRC-4Z
Fenner make or its equivalent Pilot bore resilient coupling, type: FRC-6Z
Spring Set for Fenner make or its equivalent resilient coupling, type: FRC-6Z
Fenner make or its equivalent pilot bore Pin bush coupling FBC-3 for DS pump
Fenner make or its equivalent pilot bore Pin bush coupling FBC-4 for DS pump & DE Bunker
Fenner make or its equivalent pilot bore coupling F 0225 for sump-pump/DE
Fenner make or its equivalent pilot bore coupling F 0100 for Sump pump
Fenner make or its equivalent pilot bore coupling F 0110 for Sump pump/WT preweting
Fenner make or its equivalent pilot bore coupling F 0150 for Sump pump
Fenner make or its equivalent pulley (Fan Side )ID-Pilot bore, OD-458 mm, Belt no-(SPC-4400), No of Belt Used-4 , Specification Taper lock bush type CI Pulley PCD450MM PCD459.6MM
Fenner make or its equivalent pulley (Motor Side)ID-Pilot bore,OD-310 mm,Belt no-(SPC-4400), No of Belt Used-4,Specification: Taper lock bush type CI Pulley PCD300MM PCD309.6MM
Fenner make or its equivalent pulley (Motor Side) ID-Pilot bore, OD-152 mm, Belt no-(3450/C-134), No of Belt Used-4 (For BCN-1 & BCN-2 DE) ,Type - Thru bore type
Fenner make or its equivalent pulley (Fan Side) ID-Pilot bore, OD-310 mm, Belt no-(3450/C-134), No of Belt Used-4 (For BCN-1 & BCN-2 DE) ,Specification: Taper lock bush type
Fenner make or its equivalent pulley (Motor Side) ID-Pilot bore, OD-207 mm, Belt no-(SPA-3350), No of Belt Used-3 (For BCN-2/2 Exhaust DE),Specification: Taper lock bush type
Fenner make or its equivalent pulley (Fan Side) ID-Pilot bore, OD-322 mm, Belt no-(SPA-3350), No of Belt Used-3 (For BCN-2/2 Exhaust DE),Specification: Taper lock bush type
Fenner make or its equivalent pulley (Motor Side) ID-Pilot bore, OD-310 mm, Belt no-(SPC-4400), No of Belt Used-4 (For BUNKER -3&4, CRUSHER HOUSE - 3&4 DE),Specification: Taper lock bush type
Fenner make or its equivalent pulley (Fan Side) ID-Pilot bore, OD-460 mm, Belt no- (SPC-4400), No of Belt Used-4 (For BUNKER -3&4, CRUSHER HOUSE - 3&4 DE),Specification: Taper lock bush type
Fenner make or its equivalent pulley (Motor Side) ID-Pilot bore, OD-245 mm, Belt no-(SPG-3750), No of Belt Used-4 (For Crusher House DE-1&2),Specification: Taper lock bush type
Fenner make or its equivalent pulley (Fan Side) ID-Pilot bore, OD-310 mm, Belt no-(SPG-3750), No of Belt Used-4 (For Crusher House DE-1&2),Specification: Taper lock bush type
Fenner make or its equivalent pulley (Motor Side) ID-Pilot bore, OD-257 mm, Belt no-(SPB-4000), No of Belt Used-3 (FOR BCN-2/2 Supply DE) ,Specification: Taper lock bush type
Fenner make or its equivalent pulley (Fan Side) ID-Pilot bore, OD-362 mm, Belt no-(SPB-4000), No of Belt Used-3 (FOR BCN-2/2 DE) ,Specification: Taper lock bush type
Fenner make or its equivalent pulley (Motor Side) ID-Pilot bore, OD-140 mm, Belt no-(PHG-B105), No of Belt Used-3 (FOR BCN-10 DE),Specification: Taper lock bush type
Fenner make or its equivalent pulley (Fan Side) ID-Pilot bore, OD-245 mm, Belt no-(PHG-B105), No of Belt Used-3 (FOR BCN-10 DE),Specification: Taper lock bush type
Fenner make or its equivalent pulley (Motor Side) ID-Pilot bore,OD-152 mm, Belt no-(3450/C-134), No of Belt Used-4 (BCN-3A/3B DE),Specification: Taper lock bush type
Fenner make or its equivalent pulley (Fan Side) ID-Pilot bore, OD-310 mm, Belt no-(3450/C-134), No of Belt Used-4 (BCN-3A/3B DE) ,Specification: Taper lock bush type
Fenner make or its equivalent Pilot bore resilient coupling, type: LGF-254 H
Kgen Industries
Kgen Industries
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .