Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC PLOT NO 15 JAYASURIYA STREET GANGAI NAGAR KALLIKUPPAM AMBATTUR CHENNAI 600053 | CHENNAI | CHENNAI | TAMIL NADU | 600053 | ₹7.4 L Quoted ₹7.5 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹8.1 L+₹60,851.50 (8.16%)Rejected-AOC 4 1 70 1 ROAD NO 11 SNEHAPURI NACHARAM HYDERABAD 500 076 | HYDERABAD | MEDCHAL MALKAJGIRI | TELANGANA | 500076 | ₹8.1 L+₹60,851.50 (8.16%) | L2 | Rejected-AOC Other than lowest bidder |
| 3 | L3₹8.6 L+₹1.1 L (14.7%)Rejected-AOC 19 C CUDDALORE MAIN ROAD PEDDANAICKENPALAYAM PO TK SALEM DIST PIN 636 109 | SALEM | SALEM | TAMIL NADU | 636109 | ₹8.6 L+₹1.1 L (14.7%) | L3 | Rejected-AOC Other than lowest bidder |
Tender Value
₹8.3 L
EMD Value
₹16,600
Closing Date
17 Jul 2023, 6:00 pmClosed
AGE(I) Nav Chennai
AGE(I) Navy Chennai Military Engineer Services Fort St George Rajaji Salai Chennai 600 009
REAIRS TO ROOF TREATMENT OF CERTAIN BUILDINGS OF ZONE A AREA UNDER AGE(I) NAVY CHENNAI
2023_MES_604253_1
AGE(I)/NAVY/CHN/8402 of 2023 - 24
Open Tender
Civil Works
Item Rate
180 days
Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE(I) Navy Chennai
₹16,600
Yes
26 Aug 2023
19 Jun 2023
18 Jul 2023
19 Jun 2023
17 Jul 2023
3 Jul 2023
20 Jun 2023 - 26 Jun 2023
Amount
Demolition of cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided and including removing of old APP membrane and plaster etc complete all as specified and as directed.
M&L for PCC Padding (1:2:4) type B-0 (12.50 mm graded aggregate) avarage thickness as specified to bring uniform slope in floors/ roof slab and including over apply with brushing neat cement slurry with 3.0kg/Sqm after cleaning of existing roof top surface with water etc complete all as specified and directed.
M&L for 10mm thick rendering on roof top surfaces in CM 1:3 with using with WPC @ 3% by weight of cement. Finishing the even and smooth surface etc complete all as specified and directed.
M&L for applying a tack coat of hot bitumen 85/25 @1.20 Kg/sqm over compatible primer at 0.40 ltr/Sqm complete all as specified and directed.
Cutting chases, pinning in. making good to facings for inserting galvalume sheet/ APP Membrane into the brick wall where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good to the existing surface, cutting not exc 10 cm girthcomplete all as specified and directed.
M&L for APP polymeric water proofing minimum weighing 3.00 Kg per sqm and minimum 3 mm thick reinforced with polyster non woven fabric laid over roof surface with 100 mm over lap and including vertical surfaces upto required height and tucking into grooves and sealing complete with thermofusion, torch application over and including cleaning plastered surfaces and applying two coats of solar reflector aluminium paint on APP membrane complete all as specified and directed.
Demolition of Brickwork built in cement motar, stone/boulder masonry, build in lime mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with fly ash bricks old size bricks, straight or curved on plan exc 6 mtr mean radius built in CM (1:6) complete all as specified and directed.
Taking down cement Plaster , any description, on brick walls or stone walls,etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L for rendering 15 mm thick on brick or concrete external wall surface in CM (1:4) on fair faces and finishing the surface fair and even and using WPC 3% by weight of cement as per manufacturer instructions complete all as specified and as directed.
Supplied only Integral water proofing compound complete all as specified and directed.
M&L for Preparation of new surfaces of wall and applying two coats of 100% anti fungal acrylic emulsion paint over one coat primer all as per manufacturer instruction and including necessary scaffoldings upto G+4 etc etc complete all as specified and directed.(The makes of exterior grade acrylic emulsion shall be : Asian Paints " Apex Ultima", Nerolac paints " Excel Anti Peel Emulsion", ICI Dulux " Weather Shield Max / Ultra Clean Emulsion", Berger"Weather Coat All Guard Emulsion"
S&F in repairs for 20 mm outer dia 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and composite pressure pipes including all Crimp type internal sealing Planstic metal Composite fittings (such as elbows, tees, reducers, couplers, short pieces, connectors, etc.) and hooks (in case of concealed pipe work)/ clamps (in case of exposed pipe work) etc complete all as specified. having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified.
All as per Sl item No. 13 above but for 25 mm dia complete all as specified and directed.
All as per Sl item No. 13 above but for 32 mm dia complete all as specified and directed.
S&F in repairs PPR gate valves (brass insert) outer dia of pipe 20 mm complete all as specified.
All as per Sl item No. 16 above but for 25 mm dia complete all as specified and directed.
All as per Sl item No. 16 above but for 32 mm dia complete all as specified and directed.
S&F for PVC pipe in repair 110mm dia single socketed in any length with rubber joints fixed to walls with Stack clamps out of 50 mm by 5 mm flat iron and 6mm dia round iron stays, including bolts and nuts every 1.5mtr interval and securing ends of stays to wall or roof upto G+8 Stories complete all as specified and directed.
S&F for PVC bends/ shoes any radius bore of dia 110mm with access door complete all as specified and directed.
Disconnecting existing tanks , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required and including Cleaning repairing, etc reconnecting and re-fixing in the same position capacity of tank exc 250 ltrs and not exc 500 ltrs complete all as specified and directed.
Disconnecting existing tanks , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required and including Cleaning repairing, etc reconnecting and re-fixing in the same position capacity of tank exc 500 ltrs and not exc 1000 ltrs complete all as specified and directed.
S&F for rotational moulded polyethylene water storage tank of 1000 ltrs capacity (cylindrical verftical with closed top) including dismantling of existing tank including all fittings i.e tank nipple, of 25mm dia Ball brass valves, high pressure, with polythene float and flynut etc hoisted and fixed in position complete all as specified and directed.
S&F for rotational moulded polyethylene water storage tank of 500 ltrs capacity (cylindrical verftical with closed top) including dismantling of existing tank including all fittings i.e tank nipple, of 20mm dia Ball brass valves, high pressure, with polythene float and flynut etc hoisted and fixed in position complete all as specified and directed.
M&L for 10mm thick rendering on roof top surfaces in CM 1:3 with using with WPC @ 3% by weight of cement. Finishing the even and smooth surface including taking down existing surface and opening of cracks and cleaning of existing roof top surface with water etc complete all as specified and directed.
M&L for Cleaning of roof top/sunken new or old surfaces and clean/ cutting of existing cracks and filling of Dr fixit Code No 190 Roof seal flex and applying one or more coat of Dr fixit Code No 148 Roof seal @ 0.9 ltr/ Sqm complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dismantling wrought iron or mild steelbwork of any description not otherwise provided for complete all as specified and directed.
S&F for rolled sections as in main or cross beams, rafters, purlins of specifed angular/tubular section, beams or channel sections with flange plates caps, bases, cleats and other connections Fe-410 W (Gde E-250) quality B complete all as specified and directed.
S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering to wall fixed with self tapping screws as in roof/sunshade etc all complete all as specified and directed.
M&L for preparation of new steel surfaces over 10 cm width or girth andapplying two coats of polyurethane paint over a coat of polyurethane primer etc complete all as specified and directed.
Removal of demolished materials/debris to a distance exc 1.50 KM but n exc 5.00 KM complete all as specified and directed.
SIRITEL SYSTEMS PRIVATE LIMITED
S.T.S.CONSTRUCTIONS AGENCIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .