Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC | L1 | Accepted-AOC Being the lowest bidder | |
| 2 | L2₹8.5 L+₹13,620 (1.63%)Rejected-AOC | L2 | Rejected-AOC Being other than lowest bidder | |
| 3 | L3₹9.0 L+₹57,065 (6.81%)Rejected-AOC | L3 | Rejected-AOC Being other than lowest bidder | |
| 4 | L4₹9.1 L+₹69,375 (8.28%)Rejected-AOC 65 MATA KA MANDIR RAM NAGAR COLONY SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | L4 | Rejected-AOC Being other than lowest bidder | |
| 5 | L5₹9.3 L+₹87,984.94 (10.5%)Rejected-AOC 108 AND 111 COMMERCIAL ROAD 133001 | AMBALA | HARYANA | 133001 | L5 | Rejected-AOC Being other than lowest bidder |
Tender Value
₹10.7 L
EMD Value
₹21,320
Closing Date
8 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander Works Engineer, MES, Bareilly
HEADQUARTERS, COMMANDER WORKS ENGINEER, MILITARY ENGINEER SERVICES, STATION ROAD, BAREILLY CANTT, PIN 243001
CA NO.CWE BLY/GE (E)/ 09 OF 2020-21 PROVN OF 01 X SERVO CONTROLLED AUTOMATIC VOLTAGE STABILIZER CAPACITY 400 KVA AT SHAHJAHANPUR CANTT UNDER GE (EAST) BAREILLY
2020_MES_343505_1
8200/B/624/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SHAHJAHANPUR
For enlisted contractor Class E Category b i and for unenlisted contractor meeting the eligibility criteria of class E and category b i
6 documents required · 6 mandatory
₹500
GE East Bareilly
₹21,320
Yes
29 Jun 2020
8 May 2020
13 Jun 2020
8 May 2020
8 Jun 2020
26 May 2020
8 May 2020 - 1 Jun 2020
60 days
Amount
Excavation in trenches in not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth in any type of soil taking up or laying of cable complete all as specified and directed.
Returning, filling in, any type of soil and spreading in layers not exceeding 25cm thick each layer including watering & well ramming complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed.
M&L for dry river sand laid in trenches cushioning 8cm before laying the cable and 15cm after laying the cable and punned to 18cm as cable cushioning and covering complete all as specified and directed.
M&L for laying old size bricks, sub class 'B' for protection of cable, in trenches, laid in dry flat across the cable with length of whole bricks complete all as specified and directed.
Supply & testing, commissioning of voltage stabilizer copper winding suitable for unbalance type load for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 300 V to 480 V with output voltage stabilizer at 415 with accuracy ± 2.50% and speed of correction 8 volts per second and capacity 400 KVA including first filling of oil complete all as specified and directed.
Supply and laying XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminum conductor 1100 Volts grade of size 630 Sqmm 3½ core complete all as specified & directed.
M&L PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in floor/ hard standing, surface finished even and smooth without using extra cement to match with existing surface complete all as specified and directed.
M&L for earthing complete with GI earth plate electrode 600x600x6 mm thick buried in ground vertically to a depth not less than 2.25 mtr below the ground level with top edge of the earth plate not less than 1.50 mtr below normal ground level and earth plate surrounded adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate with using 32 x 6 mm dia GI strip as earth lead moulded and retrieved to earth plate at one end and connected to main switch/ control board at another end with and including 15 cm dia GI light grade from upper end of earth plate upto external face of the wall of the build including 20 mm dia bore GI pipe light grade as water pipe from chamber to upper edge of the plate GI funnel with wire mess fixed on water pipe and provn of PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) duly reinforced with mild steel round bar 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handle with and including necessary excavation and earth work including laying the pipe concealed in floor/ wall all as per plate No-3 of SSR Part-I complete all as specified and directed and testing on completion ( Note:- If the desired resistance is not found earth shall be done by the contractor at no extra cost to Govt)
M&L, install LT panel outdoor cubicle type factory made out of CRCA sheet of 3.15 mm thick vermin proof duly painted with two coats of synthetic enamel paint and MS angle frame work with 40 x 40 x 5 mm with 45 cm length leg angle fixing to PCC including install ON Load change over switch 415 V in sheet metal enclosures 3 pole of capacity 630 Apms making connection aluminium lugs consisting PCC 1:2:4 for grouting of panel complete all as specified and directed.
CHIME ELECTRONICS
VINYAK TRADERS
M/S CHAUHAN ELECTRIC WORKS
Instruments and Equipment Co
M/S WASEEM KHAN CONTRACTOR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .