Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.4 LAccepted-AOC BUDOOBAGH NOWPORA 0 KHANYAR SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹41.2 L+₹7.9 L (23.5%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance Other than L1 Bidder | |
| 3 | L3₹43.3 L+₹10.0 L (29.8%)Rejected-Finance | L3 | Rejected-Finance Other than L1 Bidder |
Tender Value
₹49.2 L
EMD Value
₹98,500
Closing Date
9 Dec 2023, 6:00 pmClosed
Cdr, HQ 138 WE
HQ 138 Works Engineers PIN-914138 C/O 56 APO
REPAIR AND REPLACEMENT OF UNSERVICEABLE INSULATING MATERIAL OF VARIOUS PIPE LINE, BUTTERFLY VALVE, CABLE/CABLE TRAY, LT PANEL OF CHS PLANT INSTALLED AT VARIOUS UNIT AND MECHANICAL/ ROBOTIC CLEANING AND REPAIR OF AIR DUCT OF 153 GH CHS SYSTEM UNDER
2023_MES_627015_1
138WE/L-82/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 865 EWS
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE 865 EWS
₹98,500
Yes
27 Mar 2024
6 Nov 2023
16 Dec 2023
6 Nov 2023
9 Dec 2023
20 Nov 2023
Amount
M&L AHU ducts cleaning using Robot as required on all floors/ducts of 153 GH Leh and submission of Videos recording before-during -after process all as directed by Engr-in Charge.
Supply and Fix thermal Insulation of AHU ducts using 'Closed Cell Polyethylene Foam' of thickness 19-24 mm all as directed by Engr-in-Charge
M&L for Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for laying UG cable/MS pipes in trenches on plan and n exc 1.5 m in depth in hard dense soil and getting out all as specified and directed by Engr-in-Charge.
M&L for Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25m, complete all as specified and directed by Engr-in-Charge.
M&L for Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the strating point, complete all as specified and directed by Engr-in-Charge.
Maint. Of Electric Panels M & L for disconnecting the all connection in existing panel board complete and re-fixing the same after removing the burnt lugs/thimbles complete including replacing the U/S MCCBS, Contactors, relay, bus bar indicator lamps etc., all as specified and as direcrted. Note- MCCBS, Contactors, relay, indicator lamps, S/Switchs are to be measured and paid seperately.
S&F in replacement of DOL starter MK-1, 1 HP to 3 HP as per existing, complete all as specified and directed.
S&F in replacement of contactor type 3 TF 33, 415 volts complete all as specified and directed.
S&F in replacement of contactor type ML 1.5, 220 volts, complete all as speified and directed.
S&F in replacement of over load relay 8 to 12.5 Amps for contactor series 3 TF 33 complete all as specified and directed.
S&F in replacement of over load relay 1.25 to 2 Amps for contactor series 3 TF 33, complete all as specified and directed.
S&F in replacement of MCCB 63 Amps 10 KA, 3 Pole complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCCB 125 Amps 16 KA, 3 Pole complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCCB 200 Amps, 25 KA, 4 pole 415 V as per existing complete all as specified and directed.
S&F in replacement of MCCB 250 Amps, 25 KA, 3 pole 415 V as per existing complete all as specified and directed.
S&F in replacement of MCB TPN 63 Amps, 10 KA, 415 V as per existing complete all as specified and directed.
S&F in replacement of MCB SP 6-32 Amps, 10 KA, 415 V as per existing complete all as specified and directed.
S&F in replacement of on load change over switch (side handle) in sheet enclosure, 100 Amp, 415 V, 50 Hz as per existing complete all as specified and directed.
S&F in replacement of off load change over switch (side handle) in sheet enclosure, 200 Amp, 415 V, 50 Hz as per existing complete all as specified and directed.
S&F in replacement of digital type volt meter 0-500 volts, complete all as specified and directed.
S&F in replacement of digital type Amp meter complete with suitable CTs 0-300 Amps, complete all as specified and directed.
S&F in replacement of rotary type ON/OFF switches, 22mm dia as per existing, complete all as specified and directed.
S&F in replacement of push button switch in RED or GREEN colours, 22mm dia as per existing, complete all as specified and directed.
S&F in replacement of PVC flexible copper multistrand wire 3 core of 6 sqmm as per existing, complete all as specified and directed.
S&F in replacement of PVC flexible copper multistrand wire 3 core of 4 sqmm as per existing, complete all as specified and directed.
S&F in replacement of PVC flexible copper multistrand wire 2 core of 4 sqmm as per existing, complete all as specified and directed.
Maint of Boiler S&F in sequence controller suitable for 3-4 lakh kilo/hr with burner rod assembly, complete all as specified and directed.
S&F in sequence controller suitable for 1-2 lakh kilo/hr with burner rod assembly, complete all as specified and directed.
S&F in replacement of ignition rod suitable for 3-4 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed.
S&F in replacement of ignition rod suitable for 1-2 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed.
S&F in replacement of ignition Transformer electronic type suitable for 3-4 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed.
S&F in replacement of ignition Transformer electronic type suitable for1-2 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed.
S&F temp controller digital type DTC 503 with sensor suitable for 3-4 lakh kilo/Cal/hr LAL 2.25 burner rod assembly, complete all as specified and directed.
S&F temp controller digital type DTC 503 with sensor suitable for 1-2 lakh kilo/Cal/hr LAL 2.25 burner rod assembly, complete all as specified and directed.
S&F in replacement of pressure guage 0 to 20 Kg/cm sq as per existing, complete all as directed by Engineer-in-Charge.
S&F in replacement of photo cell as per existing suitable for 3-4 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed.
S&F in replacement of photo cell as per existing suitable for 1-2 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed.
S&F in replacement of burner nozzle suitable for 3-4 lakh K/Cal/Hr
S&F in replacement of burner nozzle suitable for 1-2 lakh K/Cal/Hr
S&F in replacement of Electrode suitable for burner of capacity 3-4 lakh K/Cal/Hr
S&F in replacement of Electrode suitable for burner of capacity 1-2 lakh K/Cal/Hr
S&F for closed cell elastometric insulation 30 to 40 Kg/Cub mtr density 25 mm thick (nitrite insulation) complete all as specified and directed by Engr-in-Charge.
M&L for repair of exhaust pipe by welding, complete all as specified and directed by Engr-in-Charge.
Maint of FCU S&F in replacement of fan coil unit parts, duel shaft electric motor of capacity 30 watt 930 RPM, 3 speed as per existing, complete all as specified and directed.
S&F in replacement of FCU connection of copper pipe 20/16 mm with check nut at both side as per required length, complete all as specified and directed.
S&F in replacement of plug top 15 Amps as per existing, complete all as specified and directed.
S&F in replacement of needle valve 3/8" BSP as per existing, complete all as specified and directed.
S&F in temp controller regulator type , complete all as specified and directed.
S&F in replacement of inlet outlet Ball valve 3/4" for FCU as per existing, including supply and fixing MS / GI nipple of size 3/4 inch includig welding work including cutting the existing rusty unserviceable MS/GI nipple complete all as specified and directed.
S&F Inlet/outlet ball copper valves set of 1/4", complete all as specified and directed by Engr-in-Charge.
S&F Pipe fitting of brass(Nipple outer thread) 1/4" size, complete all as specified and directed by Engr-in-Charge.
Supply and fixing radiator unit of FCU including connecting with the unit and making it leakproof of copper coils covered with aluminium finsing as per existing size of capacity 4500 K Cal / Hour including dismantling the existing unserviceable.
Supply and fixing radiator unit of FCU including connecting with the unit and making it leakproof of copper coils covered with aluminium finsing as per existing size of capacity 6000 K Cal / Hour including dismantling the existing unserviceable.
Maint. Of Flow Pipes Supply and replacement of PP-R Pipe with fitting of 40 MM size, complete all as specified and directed by Engr-in-Charge.
Supply and replacement of PP-R Pipe with fitting of 32 MM size, complete all as specified and directed by Engr-in-Charge.
Supply and replacement of PP-R Pipe with fitting of 25 MM size, complete all as specified and directed by Engr-in-Charge.
Supply and replacement of PP-R Pipe with fitting of 20 MM size, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of gun metal butter fly control valves of 100/125mm bore as per existing, complete all as specified and directed.
S&F in replacement of gun metal butter fly control valves of 80mm bore as per existing, complete all as specified and directed.
S&F in replacement of gun metal butter fly control valves of 65mm bore as per existing, complete all as specified and directed.
S&F in replacement of gun metal butter fly control valves of 40/50mm bore as per existing, complete all as specified and directed.
Supply and replacement of MS Pipes heavy grade with all fittings of 100 MM size, complete all as specified and directed by Engr-in-Charge.
Supply and replacement of MS Pipes heavy grade with all fittings of 80 MM size, complete all as specified and directed by Engr-in-Charge.
Supply and replacement of MS Pipes heavy grade with all fittings of 65 MM size, complete all as specified and directed by Engr-in-Charge.
Supply and replacement of MS Pipes heavy grade with all fittings of 50 MM size, complete all as specified and directed by Engr-in-Charge.
SUMEET TRADING CORPORATION
CHHIRPON BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .