Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹14.4 LAccepted-AOC | 1 | Accepted-AOC AOC | |
| 2 | 2₹17.1 L+₹2.4 L (16.0%)Rejected-Finance 301 TULSI TOWER KHADAKPADA KALYAN THANE MAHARASHTRA 421301 | THANE | MAHARASHTRA | 421301 | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹17.7 L+₹3.0 L (20.4%)Rejected-Finance 111 YADAV ELECRIC MARKET GB MARG LUCKNOW LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹18.6 L+₹3.9 L (26.4%)Rejected-Finance | 4 | Rejected-Finance Not being lowest | |
| 5 | 5₹21.3 L+₹6.6 L (44.9%)Rejected-Finance | 5 | Rejected-Finance Not being lowest |
Tender Value
Refer Docs
EMD Value
₹38,000
Closing Date
14 Oct 2020, 6:00 pmClosed
CWE LUCKNOW
229 MG ROAD LUCKNOW CANTT
SPL REPAIR/REPLACEMENT OF HT CABLE IN THE AREA OF TRANSMITTER STN (TELIBAGH) AND BER DISTRIBUTION TRANSFORMER AT WEST OF MG ROAD UNDER GE (E/M) LUCKNOW
2020_MES_377783_1
CWE/LKO/EM/T-16 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
MES contractors enlisted in Class E and category b(ii)and for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work and having executed similar nature of work
8 documents required · 8 mandatory
₹500
GE EM LUCKNOW
₹38,000
Yes
10 Nov 2020
16 Sept 2020
16 Oct 2020
16 Sept 2020
14 Oct 2020
2 Oct 2020
Amount
Disconnecting and taking out HT underground cable 11 KV from trences (construction of new building of BSNL site at Transmitter) and relaying the same cable by rerouting incl all connection and testing complete all as specified and directed (Excavation and earth work will be measured and paid seperatly under relavent items of this schedule).
Supply,laying,jointing,testing and commissioning HT under ground electric power cable crossed linked polyethylene (XLPE) insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 11000 volts grade suitable for earth system of 3 core 95 sqmm cross sectional area , ISI marked as per IS 7088 Part-2, laid in trnenches/laid under floor/laid in ducts or fixed on poles etc complete all as specified and directed Note- excavation/boring of road/pipe shall be measured and paid seperatly under approriate items.
Supply and fix straight through heat srink joint kit for 11 KV grade (earth) cable for complete with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor of size 50 sqmm to 95 sqmm 3 core complete all as specified and directed.
S&F cable route markers made out of PCC block (1:3:6) type C-1 using 20 mm graded stone aggregate size 900x300x100 mm thick (60 cm burried in ground) with ` DANGER/11 KV UG cable MES' embossed on route marker including excavation and earth work complete all as specifiedand directed.
M&L for boring of holes under road, pavement, hard standing by trenchles technology for laying/passing of HT cable using ultra sounding technique and necessary machine under road/hard standing complete as specified and directed. Note : if any damages to existing services such as OFC/gas pipe line/electric cable etc shall be repaired immideatelly by the contractor. Rate quoted above shall be deemed to include for the same
Excavation in trenches not exceeding 1.5 wide and not exceeding 1.5 m in depth for laying of cables, pipes and getting out incl trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed and making good disturbed surfaces.
Returning,filling in, including spreading, levelling and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material (soils) not exceeding 50 M and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for river sand washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable incl spreading and levelling complete as specified and directed. Note- Punned down thickness will be measured for payment.
M&L unreinforced pre cast concrete cable cover comply with IS 5820:1970 and shall be of grade not lower than M20 HVP type -I with peak size 300x180x40mm laid dry in trenches for the protection of underground cable complete all as specified and directed.
Supply, installation, testing and commissioning of energy efficient five star rating transformer suitable for 160 KVA step down floor mounted indoor type 11/0.433 KV, 3 phase, 50 Hz AC double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on HV side and star connected on LV side in accordance with vector symbol Dyn-11 (vector group 4) with neutral brought out on LV side with earthing and having tapping on HV side for constant out put so as to alter/vary secondary voltage by + 7.5% in equal step of 2.5% changed by means of manualy operated "Off Load" taps changing gear. The voltage regulation shall be as per IS including first fill of transformer oil as per IS-335 and including all fittings/accessories as specified in SSR Part-I and IS-1180 Part-I of 2014 . The limit of temperature rise after continuous full load run as specified in IS-1180 Part-I of 2014 and BEE shall be suitably adjusted to suite the maximum ambient temperature of 55 degree centigrade as prevalent at Lucknow. The tramsformer shall be complete with the following fittings and accessories :-
(a) Oil conservator tank with fillings holes and cap filter type drain valve and oil level guage. (b) Silicagel breather with connecting pipe, first fill of dehydrating agent. (c) Explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservatore air tank (pressure release valve). (d) Air release valve plug. (e) One cable box on LV side (Secondary) consisting of 04 Nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joints complete all as specified. (f) Explosive vent. (g) 01 No 100 mm dial type thermometer vapour pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl, max reading pointer washer etc. (h) Thermometer pocket on tank cover (j) 04 Nos plain solid CI detachable rollers. (k) Two Nos earthing terminals marking plate. (l) Rating plate and terminal marking plate (m) Extra bushing for neutral outside the cable box brought on LV side. (n) First filling of oil conforming to IS and tested upto 60 KV dielectric strength.
(o) Lifting lugs (p) Oil drain valve with plug. (q) One cable box on HV side (Primary) consisting of 01 cable gland suitable for reception of taking in HT cable including gland joints complete all as specified. (r) Dehydrating breather with first filling of dehydrating agent. (s) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI Strip . (t) Rating plate with terminal marking plate. (u) Inspection cover. (v) Extra bushing for neutral out side the LV side. (w) Hand hole of sufficient size to access interior of tank. Note :- (i) Anything missed above but is required for efficient functioning of transformer is deemed to be included in the quoted rates. (ii) The contractor shall arrange factory visit for the rep of accepting officer for testing of transformer before despatch. (iii) Any other parts/items not specified above but have been considered essential for smooth and safe functioning shall be included in the items and are covered against the quoted rate.
All as per item No. 11 above but of capacity 250 KVA .
Material and labour for disconnecting the existing transformers of various capacities from substations/ on pole/ on plinth at cantonement area and transporting to AGE E/M yard including making all necessary incoming and outgoing connection of LT and HT cables and testing complete all as specified and directed.
Diamond Electric Co.
Industrial Traders
Shree Tirupati Associates
Ajanta Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .