Firefighting work in various buildings within the premises of the Civil Court, Aurangabad.
133035
02/BCD/AURANGABAD/2026-27
Open Tender
GENERAL
Aurangabad
• 1)Audited Annual Financial Turnover from Chartered Accountant for the years
2022-2023
2023-2024
2024-2025
• 2)Certificates by Employer (not below the rank of Executive Engineer) for successful completion of works during last five years, specifying
i.Name of work
ii.Employer
iii.Location
iv.Contract amount
v.Date of start
vi.Date of completion
vii.Number of storey
viii.Total built up area of building in contract
• 3)List of Works in hand (Existing Commitment) specifying
i.Name of work
ii.Employer
iii.Location
iv.Contract amount
v.Date of start
vi.Date of completion.
• 4)C.V. of Engineers with
i.Educational qualification certificate
ii.Individual affidavit of Engineer to perform the job if allotted to bidder
• 5)Document showing ownership of plants and equipment needed for successful completion of work :-
i.Automatic Batching plant with accessories
ii.Concrete Mixer with weighing facility
iii.Steel centering and shuttering showing area in square feet
iv.water Tanker
v.Vibrator
• 6)Details of financial availability:-
i.Certificate of any Nationalized Bank extending credit facility up to 10 % of B.O.Q Amount
ii.Self declaration of investing 25 % of B.O.Q Amount.
• 7)Certificates in the form of Affidavit by the bidder for: -
i.Bidder had not abandoned any project which was taken up by bidder
ii.Bidder had never been in Litigation lying in any court of law with employer of previous works
iii.Bidder had no relative or any person directly or indirectly involved in design, execution, supervision and testing of this tendered
• 8)Bidding Capacity statement
Bidding Capacity, BC = A x N x 2 ? B
Where,
A= Maximum ATO at current price level (with 8% annual indexation)
N = Time of completion of this tendered work in years
B = Value of works in hand (Existing Commitment of Bidder)
GENERAL
PERCENTAGE
L1
1
11 documents required · 11 mandatory
₹10,000
Processing Fee: 3540
₹3.5 L
AT OFFICE OF SE Gaya Circle , GAYA 19-05-2026 03:00 pm
4 Jun 2026
4 Jun 2026
3 Jul 2026
4 Jun 2026
2 Jul 2026
4 Jun 2026
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical conforming to IS:1520
a) Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
a) Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Jockey Pump)
Fabricating, Supplying, Erection, Testing and commissioning of Electrical control panel cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet,compartmentalised with hinged lockable doors, dust and vermin proof, coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and outgoings, suitable for operation on 415V, 3 Phase, 50Hz Ac supply with enclosure protection class IP42 as required:
Providing, laying , testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS:1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gasket etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:
Supplying and fixing single headed internal hydrant valve with instentaneous Gunmetal/Stainless steel coupling coupling of 63mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal/Stainless steel cap and chain as required.
Supply and fixing single headed external yard hydrant valve with instanteneous Gunmetal/Stainless steel coupling of 63mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal/Stainless steel cap and chain as required.
Supply,fixing,testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS:13095 of following size as required.
Providing, installation, testing and commissioning of non-return valve of following sizes conforming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required.
Providing , installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6mm thick stainless steel, Grade 304, sheet with 3mm dia holes with stainless steel flange.
Supplying and fixing 63mm dia, 15m long RRL hose pipe with 63mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 ( Type-A) as required:
Supplying and fixing first aid Hose reel with M.S construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20mm nominal internal dia water hose thermoplastic (Textile reinforced) Type-2 as per IS:12585. 20mm nominal internal dia gunmetal glove valve & nozzle. Drum and brackets for fixing the equipments on wall. "Connections from riser with 25mm dia stop gun metal valve & M.S. pipe and sockets.
Supplying and fixing 63mm dia gun metal short branch pipe with 20mm nominal diameter size nozzle confirming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required.
Supplying and fixing for Fire Brigade Connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as required for suitable dia MS pipe connection conforming to IS 904 as required.
Supplying and fixing air vessel made of 250mm dia. 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.
M.S. hose cabinet with door fabricated from 16 g M.S. sheet with full glass door and locking arrangement, suitable to accommodate 1 Hydrant landing valve, 1 fire hose reel, 2 nos.15m long 63mmdia hose,1-branch pipe, The door shall be painted with one coat of primer and finished stove enamelled "Fire Red", "Fire Hose" written on front including suitably mounted on a raised masonry platform as required (Approx. size 1.2m x 2.1m). For internal hydrants.
Providing and fixing stored pressure Multipurpose fire extinguisher consisting of welded M.S. cylindrical body, squeeze lever discharge valve, 30 cms long high pressure discharge hose ISI marked as per IS:15683 including fixing to wall with brackets etc. complete.
Providing and fixing CO2 extinguisher consisting of seamless MS cylindrical body squeeze lever discharge valve, internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle ISI marked as per IS 13869 including fixing with dash fasteners etc. complete.
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of responseindicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, Installation, Testing and commisioning for server room,Smoke Extraction with Filtration system shall have inbuilt detection,extraction, filtration system with inbuilt battery backup for 30 minutes approx. No ducting/piping should be required to install the machine. Smoke Extraction system should have provision to work on both AC and DC power. (Make-Detex)
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Earth work in excavation in foundation trenches or drains (not exceding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Extra for every additional lift of 1.5 m or part thereof in :
Supplying and filling in plinth with local sand under floors including, watering, ramming consolidating and dressing complete.
Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l,
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shutering-all work upto plinth level.
1:2:4 ( 1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size)
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear thecost of extra cemen:Concrete of M-30 grade with minimum cement content of 350 kg/cum
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear thecost of extra cemen:Concrete of M-30 grade with minimum cement content of 350 kg/cum
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in :Cement mortar 1:6 (1 cement: 6 coarse sand )
Reinforcement for R.C.C work including straighting,cutting bending,Placing in position and binding all complets.
Centring and shuttering including strutting, propping etc. and removal of form for:
Foundations, footings, bases of columns etc. for mass
Columns,Pillars, Piers, Abutments, Posts and Struts
Lintels, beams, plinth bams, griders, bressumers and contilevers.
Suspended floors, roots, landings, balcnies and access platform.
Edges of slabs and breaks in floors and walis-Under 20 cms wide
Weather shade,Chajjas, corbels etc. including edges
walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Extra tor Brick work in superstructure above plinth level upto floor V cum
12MM Cement plaster in course sand:1:6(1 cement: 6 coarse sand)
6 mm cement plaster to ceiling of mix :1:4(1 cement: 4 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix.1:4(1 cement: 4 coarse sand )
15 mm cement plaster 1:3 (1 cement: 3 coarse sand ) finished with a floating coat of neat cement on the rough side of single or half brick wall.
12 mm cement plaster 1:3( 1 cement: 3 coarse sand) finished with a floating coat of neat cement
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3mm MS gusset plates at the junction and corners.all necessary fittings completejncluding applying a priming coat of approved steel primer.
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Distempering with dry distemper of approved brand and manufacture (two o more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade.Applying one coat of cement primer of approved brand and manufacture on wall surface:Distemper primer
Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade:New steel work (two or more coats)
Kota stone slab flooring over 20 mm (average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete . Base with 1:1:1 (1 lime : 1 surkhi: 1 coarse sand ) / 1:4 (1 cement: 4 coarse sand )20 to 25 mm thick
Supplying and fixing C.I. cover without frame for manholes: 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
39393_MARKING CHART_1094.pdf
NIT • 3.92 MB
NIT 02.pdf
NIT • 0.46 MB
boq nit 12.xlsx
NIT • 0.03 MB
Download all tender documents and submit your bid