Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC 111 GB MARG YADAV ELECTRIC MARKET LUCKNOW UP 226018 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226018 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹11.4 L+₹1.2 L (11.8%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L2 | Rejected-Finance NOT BEING LOWEST. | |
| 3 | L3₹12.2 L+₹2.0 L (19.9%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST. | |
| 4 | L4₹13.0 L+₹2.8 L (27.7%)Rejected-Finance 00 BAJRANG CHOK MAHOBA MAHOBA UTTAR PRADESH 210427 | MAHOBA | UTTAR PRADESH | 210427 | L4 | Rejected-Finance NOT BEING LOWEST. |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
16 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BKT
GE (AF) BKT, LUCKNOW
REPAIR/ REPLACEMENT AND IMPROVEMENT OF OLD UNSERVICABLE LIGHTING SYSTEM AT NIGHT REPAIRING HANGER , STATION MT , OPEN WEATHER SHELTER / TECHNICAL ACCOMADATION AREA MAYUR UDHYAN , SNCOS AND AIRMEN MESS AREA AND OTHER ALLIED WORKS AT AF STN BKT
2020_MES_379229_1
8434 BKT E8
Open Tender
Civil Works
Item Rate
120 days
GE (AF) BKT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) BKT
₹30,000
Yes
3 Nov 2020
19 Sept 2020
19 Oct 2020
19 Sept 2020
16 Oct 2020
4 Oct 2020
60 days
Amount
Taking down unserviceable sub main wiring any size / type / core incl earth wire complete with batten/conduit etc and making good the disturbed surface to match the existing disturbed surface all as directed.
Supply and fixing in repair of LED Bay light fitting complete of capacity 120 Watt in new generation energy saving environemental friendly long life integral industrial with pressure dia - cast aluminium housing IP65, protection impact resistance i k 70 system lumens > 12000 lumens 240 volts, 50 HZ anodised aluminium reflector including all fixing accessories i.e Clamp made out of flat iron of size 40mm X 5mm thick , Nuts and Bolts complete all as specified and directed . (Note : Light fitting will be fixed at hight approx 12 Meter). Make : - Havells/C&S/Osram/Surya Roshni/Philips
Supply and fixing in repair of flood light fitting complete in new generation energy saving environemental friendly long life exclusive innovative die cast aluminium IP65 pretection impact resistance of ik 70 LED flood light with high power LEDs as light source of capacity100 Watt complete all as specified and directed. Make : - Havells/C&S/Osram/Surya Roshni/Philips
Supply and fixing in repair of door Post top decorative type LED light fitting IP65, protection impact resistance of ik70 with diffuser long life of capacity 30 watt complete with all fixing accessories all as specified and directed. Make : - Havells/C&S/Osram/Surya Roshni/Philips
M&L for sub main wiring with two runs of 1.5 Sqmm ( 2x1.5 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through existing conduit of size 20 mm of roofs / ceiling / hanger etc with one run of 1.5 Sqmm (1x1.5 sqmm ) single core FRLS PVC insulated unsheathed multistranded copper conductor cable as earth wire complete all as specified and directed. Make of cable : - Finolex/Plaza/Rallison/National cable/Polycab
M&L for sub main wiring with four runs of 6 Sqmm ( 4x6 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to drawn through and including ERW steel conduit 20 mm dia ISI marked with all conduit accessories mounting on suface of walls /roofs / ceiling / hanger etc with one run of 6.0 Sqmm (1x6 sqmm ) single core FR PVC insulated unsheathed multistranded copper conductor cable as earth wire complete all as specified and directed. (Note:- 4 runs of 6 Sqmm (4x6sqmm ) FRLS &,one run of 6 Sqmm (1x6 sqmm ) cable and one meter of conduit will be measured as one unit). Make of cable : - Finolex/Plaza/Rallison/National cable/Polycab
M&L for sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 2.5 Sqmm (1x6 sqmm ) single core FRLS & PVC insulated unsheathed multistranded copper conductor cable as earth wire complete all as specified and directed. (Note:- 2 runs of 6 Sqmm (2x6sqmm ) & one run of 4 Sqmm (1x4 sqmm )cable and one meter of conduit will be measured as one unit). Make of cable : - Finolex/Plaza/Rallison/National cable/Polycab
M&L for sub main wiring with two runs of 4 Sqmm ( 2x4 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 2.5 Sqmm (1x6 sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire complete all as specified and directed. (Note:- 2 runs of 4Sqmm (2x4sqmm ) ,one run of 2.5 Sqmm (1x2.5 sqmm ) cable and one meter of conduit will be measured as one unit). Make of cable : - Finolex/Plaza/Rallison/National cable/Polycab
M&L , earthing complete for machinary / Equipment installed at power house / sub station with copper strip and cooper plate as earth plate electrode of size 600mmx 600mmx 3.15 mm thick buried directly in ground ( earth pit not less then 2.25 m deep below the normal ground level ) with top edge of the earth plate not less then 1.5 m below normal Ground level connected to copper earth strip 25 x3 mm as earth lead connected by means of bolts, nuts, washerws and check nuts all shown in electrical plate No.3 of SSR Part- I connected to main board / disribution board complete .Earthing copper strip 25 x3 mm and GI protection pipe 40 mm dia light grade complete all as directed (Note :- Copper strip & protection pipe 7.5mm included in the quoted rate from earth pit to test point) upto 7.5 m from earth pit.
Taking out old serviceable /unserviceable under ground cable of 16 sqmm 4.0 core to 25 sqm 4 core sizes from trenches/poles /pipe/floor complete all as directed.
Supplying , laying , passing through pipe , welded in hanger with steel saddel and connecting and testing UG cable XLPE insulated ,armoured heavy duty electric cable with aluminium conductor ,1100 volts grade of XPLE cable of size 16 sqmm 4 core. (Note:- Excavation , earth work etc will be measured and paid sepretaly). Make : Gloster/NICCO/RR Kable/Rallison/Finllox
Dittto all as item No 11 here in before but XLPE Cable of size 25 Sqmm, 4 Core .
Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete as sepecified.
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as directed.
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point complete all as directed complete all as directed.
M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation. (Note :- punned thickness shall be measured).
Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete all as specified.
M&L for GI Tubing light grade of size 40 mm dia with all fittings and fixed in wall and ceiling or laid in floors/trenches complete all as specified.
S&F in repair of astronomical time switch 110-240 volt AC supply variation (-) 20% to (+) 10% frequency 50/60 HZ, contract arrangement power consumption max 6VA, minimum switching time 1 minutes, 3 lines text LCD display clock accuracy + 2 second perday, IP-54, contact rating 40 Amp complete. Make : Legrand/Hager/Schinder 1 C/O - 2 Mod in street light circuit to control the ON/OFF timing switch for automatic switching of parimeter light based on time along with suitable power contactors and MCBs (input-output) should be enclosed in pole/wall mountable enclouser made of rust proff,Electric proof and FR grade junction box conforming to IP-54 and contactor rating 40 Amps complete all as specified and directed by Engr-In-Charge. Make :- L&T/Havells/Legrand/ABB
S & F in repair service connection 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tap and over all PVC sheathed of size 6 Sqmm 2 core complete all as specified and directed. Make of cable :- Finolex/CCI/Rallison/Plaza
S&F in repair Power contactor 3 pole - Type MNX - 45, AC-3 Rating 45 Amp, with 1 No + 1 NC Auxilary contact, Cat Part No CS94190, Make : L&T/ Legarend/Hager
S&F in repair Power contactor 3 pole - Type MNX - 32, AC-3 Rating 30 Amp, with 1 No + 1 NC Auxilary contact, Cat Part No CS94190, Make : L&T/ Legrand/Hager
Supply, install, commissioning and testing of Looping box outdoor type made out of MS Steel 16 SWG for High mast light fitting , 3 phase, 4 wire , 415 volt with aluminium bus bars strips of 200 amps capacity with necessary clamps, nuts, bolts and wahsers floor mounted type made with angle iron legs and painted with two coats of synthetic enamel paint over a copat of red oxide primer , suitable for control of light fitting independetly mounted on a din rail prewired with suitable size of copper conductor cable and equally distribution on each phase and controlled by MCCB four pole 100 Amp for control of main cable including timers and contactors of suitable size , locking arrangement complete including multi core copper conductor cable for above fixtures complete all as specified and as directed by Engr-in-charge
S&F MCCB four pole , 415V , fixed thermal and magnetic setting of capacity 125 Amp, breaking capacity 25 KA complete all as speficied and directed by Engr-in-charge . Make : L&T/Schenider/Legrand
S&F MCCB four pole , 415V , fixed thermal and magnetic setting of capacity 160 Amp, breaking capacity 35/36 KA complete all as speficied and directed by Engr-in-charge . Make : L&T/Schenider/Legrand
S&F MCCB four pole , 415V , fixed thermal and magnetic setting of capacity 200 Amp, breaking capacity 35/36 KA complete all as speficied and directed by Engr-in-charge . Make : L&T/Schenider/Legrand
M&L complete for drilling hole under hard standing /road in different location as per site requirement (between 03 mtr to 12mtr maximum) for laying of pipe for protection of cable etc by means of mannual bookle and without disturbing the top surface and making good the disturbed surface if any complete all as specified & directed.
Unnati Engineers
Ajanta Motor Store
M/s Hindustan Trading Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .