Engineering Wing of Health and Family Welfare Department
Praveen B A
Providing Additional 1000 KVA TC, LT Control Panel Board, Construction of HT Yard & Control Panel Room and allied works to MIMS Teaching Hospital at Mandya
EWHFWD/2023-24/BD/WORK_INDENT359
EWHFWD/2023-24/BD/WORK_INDENT359
Open
Buildings
Two Tender Document System(Two Cover)
EWHFWD Chief Engineer Office Bengaluru
4 documents required · 4 mandatory
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Executed in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Owning the following key and critical equipment for this work (xxxx, xxxx, xxxx)
Liquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
List of Financial Resources with Certificates
3.2aTo qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23)Clause ITT 3.2a:The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of Engineering works only) of Rs.303.24 Lakhs
Clause ITT 3.2bTo qualify for award of this contract,each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23)The tenderer should have been Satisfactorily completed at least one Similar work of value not less than Rs.75.81 Lakhs as prime contractor.
Clause ITT 3.2(c): To qualify for award of this contract,each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23).Executed in any one financial year,the following minimum quantities of work Sl.No Description of key items of works Quantity 1 Transformer 500 KVA TC-1 No 2.RMU-1 No 3.Span pole with structural work, DP with structural work-1No 4.11KVA HT UG cable-160mtr 5.700 A to 800A MCCB-3 Nos 6. LT UG cable 95sqmm to 400sqmm-600mts Note:The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/Semi Government/Government undertaking/ autonomous bodies of Government will be considered, for the clause 3.2 (c)
Clause ITT3.6 Tenderers who meet the above specified minimum qualifying criteria will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity(AxNx1.5-B)where A Maximum value of civil engineering works executed in any one year during the last five years i.e (2018-19-2022-23)(updated to2023-24 price level)taking into account the completed as well as works in progress .N Number of years prescribed for completion of the works for which tender are invited. B Value at 2023-24 price level, of existing commitments of and ongoing works to be Completed during the next 03 months. Note:(1)The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent(2)Tenderer shall submit the list of Ongoing works duly certified by the Auditor/Chartered Accountant.
List of Minimum Key Personnel to be deployed by the contractor at site for Contract work 1)Site Engineer BE Civil with minimum experience of 5 years in the Constructions of building or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (One) 2)Electrical Engineer B.E. Electrical with minimum experience of 5 years in the Construction of buildings or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (One) Note: 1) The tenderer shall submit list and photo identity proof such as Aadhar Card/Voter ID/Employee ID/Pass port/Driving License etc., for the key personnel such as project manager/site engineer to be deployed at each of the worksite. 2) The key personnel deployed at the site for this work should be working for a minimum period of one year with the tenderers and experience certificate has to be furnished in this regard.
Class-I Registered in CEIG:Chairman LA & EB, Bangalore Certificate.
Clause ITT 3.3(b):Liquid assets and/or availability of credit facilities of not less than Rs.45.49 Lakhs (Credit lines/letter of credit/certificates from banks for meeting the fund requirement etc.,)
₹3,800
₹2.3 L
2 Mar 2024
2 Mar 2024
14 Mar 2024
6 Mar 2024
11 Mar 2024
Providing Additional 1000 KVA TC, LT Control Panel Board, Construction of HT Yard & Control Panel Room and allied works to MIMS Teaching Hospital at Mandya (Civil Works)
Earth work in surface excavation by manual means for lowering & levellingthe ground by chiselling and wedging in Hard rock for all works other thanfoundation & depth not exceeding 100 mm as per drawin...
Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and suchsimillar works in all kinds of soils, as per dra...
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes ...
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes ...
Supplying and fixing RCC precast fencing pole of size 0.15mx0.15mx2.0m casted in M 20 with 20mm down size aggregates making holes for drawingbarbed wire at 30 cm c/c using 8 mm dia vertical 4 TMT stee...
Providing and fixing G.I. chain link fabric fencing of required width in meshsize 25x25 mm made of G.I. wire of dia 3 mm including strengthening with2 mm dia wire or nuts, bolts and washers as require...
Construction of Granular Sub-Base of required grading as pe design mixing in a mechanical mix plant at OMC, carriageof mixed Material to work site, spreading in uniform layerswith motor grader on prep...
Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approve...
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work afterthoroughly brooming the surface to remove all dirt, dust, mortar dropsand forei...
Supply and installation of 9Kg Powder Based stored presure type melting
point at 1200 degree C, Applicable on Class D metal fires in heavy metals,
alkali metals and alloys Pressure Guage, Gross Weight...
Supplying of four bucket stand alongwith buckets. Complete
Providing Additional 1000 KVA TC, LT Control Panel Board, Construction of HT Yard & Control Panel Room and allied works to MIMS Teaching Hospital at Mandya (Electrical Works)
Pre - Stressed Tubular Spun Pole 11 Mtr Long - 500 Kg WL with Labour Charges
11 kV, Horizontal Cross Arm with HT Single Top supports, clamps, bolts, nuts & washers - MS For RCC Pole with Labour Charges
45 KN Disc Insulator Porcelain
11 kV, 5 KN Composite/Polymeric Pin Insulator (24 mm Dia FRP Rod)
ACSR conductor as per IS : 398 (Part - 2/1996)are the latest revision Rabbit ACSR (6/3.35 mm Al+1/3.35 mm St), Std Wt: 214 Kg/KM
DOLO Cut Out with Labour Charges
LT Protection Kit (Dwg No. BESCOM/GM/QS&S/10 Dtd 24.11.2018 with Labour charges
Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr
Distribution Transformer - 3 Phase 11kV/433V - Amorphous Core with Oil as per IS-1180 (Part-1): 2014 (CESC SR 5/130/ 13.08) B. CABLE ENTRY TYPE. 500 kVA, Aluminium Wdg, Star 2 (5 Star)
Erection of Double Pole Transformer Structure using 9 Mtr Long RCC (145 Kg WL)/PSCC (300 Kg WL) Pole including fixing of Structure Materials, Erection of Poles etc., complete for mounting of Transform...
11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Meterin...
Erection of HT metering Cubicle on Platform
Conventional RMU (VCB Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC- 62271/IS-3427 3 Way RMU, 2OD + 1VL (One Incomer + One Breakers + One Outgoing)
11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 ( 240 Sqmm, (55 GI Wires - 3.15 mm ...
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 3x185 to 240 Sqmm
Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards ...
Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3x240 Sqmm
Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x240 Sqmm
Fixing of Termination Kit
Heavy Duty Copper Terminal Long Barrel. 240 Sqmm Copper Terminal, Apprx Wt: 218 Gm
Construction of platform with size stone, cement concert for erection of 500 kVA Transformer/Metering cubicle/Heavy Equipment.Construction of platform (1.5x1.5x1.2) Mtr in size stone, for erection of ...
GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg
Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each
Good Quality Salt for grounding purposes packed in 50 Kg gunny bag
Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment g...
Bentonite clay slurry for earthing in 50 Kg Bag
Supplying of 40mm& down size granite metal jelly and spreading to the TC yard etc., as per ISI and ISo (888*1.03)
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direct...
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitr ed, welded and grinded finish, wi...
Spun Pole Concrete Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant I...
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of O...
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of O...
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of O...
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of O...
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of O...
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of O...
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of O...
Supplying and fixing of Shunt trip suitable for MCCB.CBCT (12/5.15)
Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage curr...
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.
Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter..
Supplying of on load change over switches 4 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 800 A
Supplying of on load change over switches 4 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 400 A
Supplying of on load change over switches 4 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 200 A
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT ...
Supplying & fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capac...
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacit...
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacit...
Fabricating supplying and mounting MS box made out …SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped...
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC ins...
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC ins...
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC ins...
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint...
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint...
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
GI Pipe B - Class as per IS-1239 GI Pipe - 50 mm Dia
GI Pipe B - Class as per IS-1239 GI Pipe - 63 mm Dia
GI Pipe B - Class as per IS-1239 GI Pipe - 100 mm Dia
Brass Cable Gland 25 mm
Brass Cable Gland 32 mm
Brass Cable Gland 40 mm
Brass Cable Gland 45 mm
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 S...
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 . 25 Sq...
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sq...
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 95 S...
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 120 Sq...
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 150 Sq...
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 185 S...
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 300 ...
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 400 S...
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 Sqmm
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 35 to 95 Sqmm
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 120 to 240 Sqmm
Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in exisiting trench as per IS 14930 part -II su...
Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in exisiting trench as per IS 14930 part -II su...
Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in exisiting trench as per IS 14930 part -II su...
Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in exisiting trench as per IS 14930 part -II su...
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor
Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage icroprocessor operation, relays LED display, self rogramming function for power...
Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board. 63 A 4 pole
Supplying, fixing and wiring 0 to 30A Direct Reading AC analog
Supplying, fixing and wiring 0 to 30V Direct Reading DC Voltmeter/Ammeter.
Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947 40 A
Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947 100 to 1...
Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 Mtr
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
KW-4-359.doc
Tender Document • 2.37 MB
technical specification.doc
Technical Information / Worksheet • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .