Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹20.3 CrAccepted-AOC 11 JAMES HICKEY SARANI FORMALLY KNOWN AS DACRES LANE 2ND FLOOR KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | ₹20.3 Cr | L-1 | Accepted-AOC L-1 Bidder |
| 2 | L-2₹20.5 CrRejected-Finance | ₹20.5 Cr | L-2 | Rejected-Finance Rejected. Other than L-1. |
| 3 | L-3₹22.5 CrRejected-Finance HOUSE OF RAJ KUMAR GOEL PO MATELLI MATELLI BAZAR JALPAIGURI | MATELLI BAZAR | JALPAIGURI | WEST BENGAL | ₹22.5 Cr | L-3 | Rejected-Finance Rejected. Other than L-1. |
| 4 | L-4₹22.5 CrRejected-Finance SITANI BUILDING DINBAZAR JALPAIGURI 735101 | JALPAIGURI | JALPAIGURI | WEST BENGAL | 735101 | ₹22.5 Cr | L-4 | Rejected-Finance Rejected. Other than L-1. |
| 5 | L-5₹24.1 CrRejected-Finance | ₹24.1 Cr | L-5 | Rejected-Finance Rejected. Other than L-1. |
Tender Value
₹20 Cr
EMD Value
₹13.3 L
Closing Date
4 Jan 2025, 6:00 pmClosed
CE SILIGURI ZONE
HQ CE SILIGURI ZONE, MES, SEVOKE ROAD, PO SALUGARA, DIST JALPAIGURI, PIN 734 008 (WB)
PROVN OF MD ACCN (PH-II OF TWO PHASES) AT SUKNA MILITARY STATION UNDER GE (P) SILIGURI
2024_MES_684064_1
98788/SUK/SZ/E8
Open Tender
Civil Works
780 days
SUKNA
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE (P) SILIGURI
₹13.3 L
Yes
HQ CE SILIGURI ZONE, MES, SEVOKE ROAD, PO SALUGARA
4 Apr 2025
15 Nov 2024
11 Jan 2025
15 Nov 2024
4 Jan 2025
16 Dec 2024
15 Nov 2024 - 19 Nov 2024
23 Nov 2024
Amount
BUILDINGS & STRUCTURE (Sch 'A' PART-I)
Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE” as listed in Schedule ‘A’ Part-I. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 20,01,40,000.00 inserted by the MES in Schedule ‘A’ Part-I.
EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch 'A' PART-II)
Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT” as listed in Schedule ‘A’ Part-II. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 17,19,956.01 inserted by the MES in Schedule ‘A’ Part-II.
INTERNAL WATER SUPPLY (Sch 'A' PART-III)
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-III. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 16,60,588.67 inserted by the MES in Schedule ‘A’ Part-III.
INTERNAL ELECTRIFICATION (Sch 'A' PART-IV)
Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 71,99,127.61 inserted by the MES in Schedule ‘A’ Part-IV.
ROAD, PATH, CULVERT & HARDSTANDING (Sch 'A' PART-V)
Lump sum price worked out by the Contractor for “(ROAD, PATH, CULVERT & HARDSTANDING)” as listed in Schedule ‘A’ Part-V. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 64,90,355.79 inserted by the MES in Schedule ‘A’ Part-V.
SEWAGE DISPOSAL (Sch 'A' PART-VI)
Lump sum price worked out by the Contractor for “(SEWAGE DISPOSAL)” as listed in Schedule ‘A’ Part-VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 4,93,798.30 inserted by the MES in Schedule ‘A’ Part-VI.
AREA DRAINAGE (Sch 'A' Part-VII)
Lump sum price worked out by the Contractor for “(AREA DRAINAGE)” as listed in Schedule ‘A’ Part-VII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 31,40,158.50 inserted by the MES in Schedule ‘A’ Part-VII.
EXTERNAL WATER SUPPLY (Sch 'A' Part-VIII)
Lump sum price worked out by the Contractor for “(EXTERNAL WATER SUPPLY)” as listed in Schedule ‘A’ Part-VIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 2,96,074.68 inserted by the MES in Schedule ‘A’ Part-VIII.
EXTERNAL ELECTRIFICATION (Sch 'A' PART-IX)
Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 19,08,249.95 inserted by the MES in Schedule ‘A’ Part-IX.
FIRE FIGHTING (Sch 'A' Part-X)
Lump sum price worked out by the Contractor for “(FIRE FIGHTING)” as listed in Schedule ‘A’ Part-X. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 15,55,491.40 inserted by the MES in Schedule ‘A’ Part-X.
SOLAR WATER HEATER (Sch 'A' Part-XI)
Lump sum price worked out by the Contractor for “(SOLAR WATER HEATER)” as listed in Schedule ‘A’ Part-XI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 17,36,043.40 inserted by the MES in Schedule ‘A’ Part-XI.
LIGHTNING PROTECTION (Sch 'A' Part-XII)
Lump sum price worked out by the Contractor for “(LIGHTNING PROTECTION AND DG SET) ” as listed in Schedule ‘A’ Part-XII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 4,51,780.86 inserted by the MES in Schedule ‘A’ Part-XII.
LIFT (Sch 'A' Part-XIII)
Lump sum price worked out by the Contractor for “(LIFT)” as listed in Schedule ‘A’ Part-XIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 68,58,654.80 inserted by the MES in Schedule ‘A’ Part-XIII.
MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch 'A' Part-XIV)
EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT Bringing approved Earth or RBM (River Bed Materials) may be mixed with granules / pebbles not exceeding 40 mm size (as approved by Garrison Engineer) from sources outside defence land including all cost such as royalty if any, transportation, taxes if any etc. complete all as specified and directed. NOTE :- (a) Earth or River Bed Materials required for the item shall be supplied by contractor from outside of MOD land at any lead, at his own arrangement. (b) All cost of procurement of earth including cost of transportation, compaction royalties, tax etc shall be deemed to be included in the unit rate quoted by the contractor. (c) Forming embankments / filling in low lying areas including raising (or lowering) earth, spreading in layers not exceeding 30 cm thick, watering ramming / rolling and finishing of required size, shape etc not exceeding 1.5 m high from base / natural ground level. (d) With reference to Clause 3.6 of MES Schedule Part-II on Serial Page No. 21, it is clarified that measurement of the above item shall be of finished embankment / traverse of filled earth after consolidation / compaction and 5% deduction shall be made from measured and calculated volume to allow for increase in bulk. (e) Total quantity / partial quantity of earth may not be available in Sevoke Area. The contractor shall bring the earth outside area and it is advised to quote the rate considering available of soil and its lead involved.
ROAD, PATH & CULVERT Supply and installation of Raised Pavement Marker (RPM) with polycarbonate lens electronically welded with the RPM body. The marker shall be scratch proof and abrasion resistant microprismatic polycarbonate lens with polycarbonate reflective panels with dual prismatic cubescapable providing total internal reflection. The dimension of the marker is height 15.88mm, width 101.6mm, length 89.2mm. The marker conforms to ASTM D4280 and is in accordance with MOSRTH circular reference No. RW/NH 33023/10/97-DO III dated 11 June 1997. Marker shall be fixed with adhesive and no nails shall be used to affix the marker and shall be marked with manufacturer name complete all as specified and directed.
INTERNAL WATER SUPPLY S & F two way bib cock, chromium plated, with wall flange quarter turn (Low-flow) 16 mm bore complete all as specified and directed.
S & F 16 mm bore chromium plated mixer (wall / table mounted) complete all as specified and directed.
S & F bib cock, chromium plated, with wall flange quarter turn (Low-flow) 16 mm bore complete all as specified and directed.
S & F Hand shower (health faucet) with 1 meter long easy flex tube in chrome finish and walll hook with NRV (Back flow preventer) complete all as specified and directed.
S & F Angular Stop cock 15mm bore of pipe (16 mm outer dia) with wall flange chromium plated stop valves complete all as specified and directed.
S & F overhead shower 140mm round shape single flow with air effect (ABS & face plate chrome plated) with rubit cleaning system 16mm dia, with shower Arm Casted 120mm long heavy body round shape for wall mounted showers with wall flange complete all as specified and directed.
S & F wall mixer with provision for overhead shower, chromium plated, with 115mm long bend pipe on upper side, connecting legs & wall flanges complete all as specified and directed.
INTERNAL ELECTRIFICATION S&F Modular type TV Co-axial socket outlet-1 Module in the modular MS / GI sheet box and cover plate including concealed 40mm PVC conduit in wall/ceiling/fixed to roof connections etc complete all as specified and directed.
S&F Modular type RJ-11 telephone socket outlet in the modular MS/GI sheet box and cover plate including concealed 25mm PVC conduit in wall/ceiling/fixed to roof connections etc complete all as specified and as directed.
S&F Metal flush box 8 module complete all as specified and as directed.
S & F Decorative wall light fixture made up of Polycarbonate, suitable for 10/5 W retrofit LED Lamp B22 base including connecting up with twin core twisted flexible copper conductor cable with suitable size, 230V, 50Hz complete all as specified and directed.
Supply and fix 5 watt LED bulb complete all as specified and directed.
Supply and fix 10 watt LED bulb complete all as specified and directed.
Fabrication supply & fixing of GI pipe bracket up to 32 mm dia- 0.9m long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for 1x35W LED security light fitting complete all as specified and directed.
S & F TPN DB 6 way (Vertical), IP43 with metal door as per IEC 61439-3 sitable for flush/surface mounting with 100Amp fully insulated Copper Busbar for each phase with 2 shrouded Neutral bar , 2 Earthbar and cable ties , prefitted masking sheet , reversible Door for IP-43 & IP-54 DB's with provision for FP MCB/RCCB/RCBO as incommer and SP/TP MCB's as outgoing without MCBs complete all as specified and directed.
S & F MCCB, 4 Pole, 415 V, fixed type, 80 Amps with breaking capacity 25kA complete all as specified and directed.
Supply, fixing and commissioning and Design verified as per IS /IEC-61439-1&2 LT Panel, indoor type LT Panel Box by CPRI Approved manufacturers with comprising of the following and complete all as specified and directed. Fabrication Details : Main frame 3 mm thick CRCA sheet, partition sheets / covers / doors of 2 mm thick CRCA sheet, gland plates 2 mm thick MS sheet (undrilled), base frame of 75 mm MS channel with provision of incoming and outgoing cable entry at the bottom for installation, seperate chambers for Main Bus Bars, switch Gears and Cable end connections free standing floor mounted with degree of protection IP 54 and with heavy duty Hinges for doors and locking arrangements with Aldrops at front and Back complete all as specified and directed. Bus bar details : Material shall be Copper bus bar 600Amp rated, sleeving heat shrinkable type, with bus bar sizes for phase of rated capacity and bus bar shall extended type be support of epoxy type insulators for connection, earthing of 40x6 mm GI Flat complete all as specified and directed. Painting Detais : Painting shall be 7 tank processed powder coated shall be a dry finishing process that uses finely ground particles of pigment and resin based polymer that are electrostatically charged and sprayed onto electrically grounded parts complete all as specified and directed. Wiring : Pannel wiring shall be of 2.5 sq mm copper standard with 5A MCB wiring for controll wiring and indication lamps complete all as specified and directed. Item Contined as Ser No. 14.21
Accessories for Panel Box : Digital Multifunctional Meters CT/PT programmable with RS 485 communicatio port CL 0.5 with direct acess to basic power and Energy parameters and Indication Lamps (LED) - 03 No. Incoming Switch Gear (a) MCCB 400 Amps rating 415 Volts, 4 pole, 36 kA (Ics=100%icu) with adjustable thermal & magnetic release (80-100%) & earth fault protection-01 Nos complete all as specified and directed. (b) Indicating lamp RYB -01 Set (Set of three) Outgoing (a) MCCB TP, 80 Amp, 415 Volts, 25 kA (Ics=100%icu) with adjustable thermal & magnetic release (80-100%) & earth fault protection- 08 Nos (O/G) complete all as specified and directed. (b) SP 32 Amps, 10 kA -03Nos NOTE : Rate quoted includes for necessary PCC foundation / steel angulars/ channels to LT pannel and includes the cost of all Accessories and switch gears, necessary cable connections with Lugs, washers nut bolts and cable glands as per site requirement complete all as specified and directed.
SEWAGE DISPOSAL Supply and laying DWCPE (SN8) 180 (OD)/163(ID) mm diameter pipes line including necessary joining and laid in trenches as per drawing in any length to make sewer line functional and testing complete all as specified and directed.
EXTERNAL WATER SUPPLY S & F ductile iron fitting/flange/SS/bend/reducer 80 to 200 mm dia of different size as required at site and directed.
Supply & Laying duclite iron (DI) pipe flanged ends, centrifugally cast, class K-7 in length laid in ducts under floor / walls / columns etc. of bore size 100 mm including rubber gasket push on joints complete all as specified and directed.
M&L for construction of brick masonary valve pit of intemal dimensions 900mm x 900 mm x 900 mm complete and fabrication of 3.0 mm thick MS Sheet cover and angle iron frame made out of 40mm x 40mm x 6 mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer induding necessary earth work and PCC work complete all as specified and directed.
M&L for construction of brick masonary valve pit of intemal dimensions 600mm x 600 mm x 600 mm complete and fabrication of 3.0 mm thick MS Sheet cover and angle iron frame made out of 40mm x 40mm x 6 mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer induding necessary earth work and PCC work complete all as specified and directed.
EXTERNAL ELECTRIFICATION Supply and fixing 8.0 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimentions of Pole as Top Diameter - 70 mm, Bottom Diameter- 130 mm, Section Length - 8000 mm, Thickness - 3 mm, Foundation type Base Plate (200 x 200 x 16 mm), Foundation Bolts - 4 Nos 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projects bolt length 100 mm, with Single type arm bracket 1500 mm long, top dia 70 mm, suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding complete all as specified and directed.
Supply, installation, testing and commissioning of out door type LT feeder pillar box of suitable size, pedastal mounted, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 50 x 50 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 40 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (DG panel) Item Contined as Ser No. 14.29
Supply, installation, testing and commissioning of out door type LT feeder pillar box of suitable size, pedastal mounted, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/MCB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 50 x 50 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 40 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (LT Panel) Item Contined as Ser No. 14.31
Supply and fixing astronomical time switch for changing the switching on/off timing in accordance to seasonal sun rise / sun set timing, through in-built device, based on daily astronomical calculation of the sun rise / sun set times of a particular location complete with necessary electrical connection with the MCB-Contactor combination inside steel enclosure including provn of 4 Pole Power Contactor 20/25 Ampscap including connections complete all as specifed and directed.
Supply and fixing medium intensity aviation light complete all as pecified and directed.
FIRE FIGHTING Supply, install, testing and commissioning of "Out door type" LT Distribution Board of suitable size factory fabricated CPRI type tested with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 and general construction , front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 3.15 mm thick CRCA sheet duly pre-treated & powder coated, supporting frame angle iron suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring incl cable glands of suitable sizes incl PCC platform/plinth of suitable size complete all as specified & as directed with & incl the following accessories : (Fire Panel) BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos tinned copper 150 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections form main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both in-comming & out-going cables. INCOMING (i) MCCB FP, 80 Amps rating, Ics=100%Icu, 16 kA breaking capacity, adjustable thermal magnetic release - 01 No Item Contined as Ser No. 14.35
Supply and fixing fire extingusiher, Dry Chemical Powder, ABC type 6.00 kg Capacity complete with initial charge and wall bracket BIS and BSEN standard complete all as specified and directed.
Supply and fixing Fire Extinguisher CO2 Type (light weight squeeze grip type) 4.5 Kg BIS standard complete all as specified and directed.
Supply and fixing Fire Extinguisher Water Stored Pressure Type 9.0 Ltr capacity BIS standard complete all as specified and directed.
Supply and fixing Fire Extinguisher Mechanical Foam Type 9.0 Ltrs capacity BIS standard complete all as specified and directed.
S&F auto-illuminated (glow-in-dark) exit sign board with red colour background with appropriate symbol, made up of acrylic sheet for fire escape in minimum 10 cm x 30 cm size to be pasted on wall with high quality adhesive or to be hanged with SS hook-chain system complete all as specified and directed.
Supply and fixing rechargeable type ceiling/wall mounted Escape lighting showing exit sign in green colour provided with in-built battery suitable to provide minimum 90 min contineous lighting after power cut complete all as specified and directed.
Supply and fixing Fire Bucket 09 Ltrs made of iron with high functionality, able to withstand very high temperature with ring handle complete all as specified and directed.
Supply and fixing XLPE insulated heavy duty FRLS copper ammoured conductor 2.5 Sqmm 6 Core, with working voltage 1100 volts conforming to IS: 1554 part -I complete all as specified and directed.
SOLAR WATER HEATER M&L for fixing the MCB SPN 16 Amps 10 KA rupturing capacity complete all as specified and directed.
DOOARS CONSTRUCTION COMPANY (BID ID -3200318)
ANUGRAH CONSTRUCTION PVT. LTD. (BID ID -3200768)
M.P. SITANI AND SONS (BID ID -3200404)
DNS CONSTRUCTION COMPANY (BID ID -3200514)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid