TheASSISTANT Engineer PWD,DDESD
Office of the Assistant Engineer, P.W.Dte. Dhana Dhanya Electrical SubDivision PWD Office Building 2ndFloor, 32, Belvedere Road, Alipore,Kolkata 27
Supply and installation of Air conditioner machine at South Calcutta Girls College, 72, Sarat Bose Road, Kolkata-700025.
2026_WBPWD_5014055_2
29/Q/AE/DDESD/PWD/2026-27
Open Tender
ELECTRICAL WORKS ORG
10 days
Alipore
PLEASE REFER TENDER documents
8 documents required · 8 mandatory
₹2,231
O/O The Assistant Engineer PWD DDESD
12 Jun 2026
12 Jun 2026
29 Jun 2026
12 Jun 2026
25 Jun 2026
18 Jun 2026
12 Jun 2026 - 17 Jun 2026
17 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5-year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC. (Make:- O General/Mitsubishi Heavy/Daikin) | ||||||
| 1.1 | Cooling Capacity- 3.5 kW (Minimum) , Air Flow Rate:400 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star(min) | 1 | Nos. | 2.25 | ₹2.25 | 2 |
| 1.2 | Cooling Capacity- 6.1 kW (Minimum) , Air Flow Rate:800 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star(min) | 1 | Nos. | 3.25 | ₹3.25 | 3 |
| 2S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of above AC machines. | ||||||
| 2.1 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above said AC, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XLPE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : (Make- Approved by EIC) | - | - | - | - | 5 |
| 2.2 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 7 | Mtrs | 6.25 | ₹43.75 | 6 |
| 2.3 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 7 | Mtrs | 7.25 | ₹50.75 | 7 |
| 2.4 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 14 | Mtrs | 8.25 | ₹115.5 | 8 |
| 3S&F of additional following items for length exceeding 3.5 mtr for complete installation and commissioning of aboove AC machines. | ||||||
| 3.1 | 2.5 sqmm, 3/4 core copper cable (FRLS type) (Make- Polycab/Gloster/Finolex/Havells /RR Kabel as Approved by EIC) | 10 | Mtr | 8.25 | ₹82.5 | 10 |