First class brickwork in superstructure above plinth level upto floor V level in: (a) in cement mortar (1 cement : 3 coarse sand)
12mm cement plaster (1 cement : 4 fine sand) finished with a floating coat of neat cement
Providing and fixing Wood Plastic Composite board walling with necessary screws etc. complete (b) With 17mm thick WPC Board
Providing and ceramic glazed floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS: 15622 of approved make in all colours, shades, except white. ivory, grey, fume red brown, laid on 20mm thick cement mortar (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigments etc. complete as per designed colour (a) Gloss finish
Applying one coat of Efflorescence resistant penetrating primer for Raincoat, Newcoat & Heatshield of approved brand and manufacture on wall surface cement primer of approved brand and manufacture on wall surface
Applying priming coat with ready mixed primer of approved brand and manufacture on plastic surface (a) Ready mix white primer
Wall painting with interior emulsion paint of approved brand and manufacture on new work (two or more coats) to give an even shade
Sculptures
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
Supply and fittings of casing capping, wall type including fixing equipment of different standard size with accessories (Casing Capping complete)
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required - 2X4 sq.mm + 1X4 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required - 2X0.75 sq.mm + 1X0.75 sq.mm earth wire
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 5/6A Switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 15/16A Switch
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCB?Isolator) - 6 way double door
Supplying and fixing 5A to 32A rating, 240/415V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connectiobs, testing and commissioning etc. as required - Single Pole
Supplying and fixing 5A to 32A rating, 240/415V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connectiobs, testing and commissioning etc. as required - Double Pole
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB) having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required (63A)
Earthing with G.I. earth plate 600mmx600mmx6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required
Providing and fixing 4.00mm dia copper wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required - 1 or 2 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required - 3 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required - 6 Module
LALRINSANGA RALTE SIAKENG
Lalramsanga
R. Vanlalhluna
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .