Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹7,990Qualified Make: Labtronics
Model: LABTRONICS 23 BAJRANG VIHAR CHAPOLA KI DHANI SANGANER JAIPUR RAJASTHAN 302029 | JAIPUR | RAJASTHAN | 302029 | Make: Labtronics
Model: LABTRONICS | ₹7,990 | L1 | Qualified |
| 2 | Disqualified Make: Labtronics
Model: LABTRONICS & LT 10 MADHOKUNJ ALLAHABAD UTTAR PRADESH 211002 | PRAYAGRAJ | UTTAR PRADESH | 211002 | Make: Labtronics
Model: LABTRONICS & LT 10 | - | - | Disqualified |
| 3 | Disqualified Make: AARSON
Model: RSCH-360B 9 10 KHOJKI PUR P O INDUSTRIAL ESTATE AMBALA HARYANA 133001 INDIA | AMBALA | HARYANA | 133001 | Make: AARSON
Model: RSCH-360B | - | - | Disqualified |
| 4 | Disqualified Make: abron
Model: Abron Ac 308D 105 INDUSTRIAL ESTATE AMBALA CANTT HARYANA 133001 | AMBALA | HARYANA | 133001 | Make: abron
Model: Abron Ac 308D | - | - | Disqualified |
| 5 | Disqualified Make: Accumax India
Model: Accumax Model-501 And More 50,49,10,11 105 FIRST FLOOR VISHAL TOWER DISTRICT CENTRE JANAKPURI JANAKPURI WEST DELHI DELHI 110058 UDYAM DL 11 0022043 07ASXPS7874B1ZX R M MII STATUS AS VERIFIED | WEST DELHI | DELHI | 110058 | Make: Accumax India
Model: Accumax Model-501 And More 50,49,10,11 | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
11 Aug 2018, 8:00 pmClosed
pH Meter Average Turn Over of Last 3 Years 1 Lakh (s) Experience with Gov. Required 5 Year (s) PH Meter ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values CONFIGURATION Type Microprocessor Based Microprocessor Based
Microcontroller Based Display LED/LCD/Touch Screen
3 digits - Calibration up to 3 points with auto buffer - pH Range (pH) 0.00 to 14.00 - Accuracy (pH) +- 0.05 +- 0.05 Corrosion Resistant Yes - Power Requirements 230 V +- 10
50 Hz AC - Modes pH mV- C - Parallel temperature indication Yes - Temperature Compensation Type Automatic Automatic
Manual Temperature Accuracy (Degree C) +- 0.3 +- 0.3 Temperature Compensation Range (Degree C) 0 to 100 - 1/3 Resolution (pH) 0.01 - Operating Humidity: RH in (%) 40 - Operating Temperature (Degree C) 20 - Warranty Warranty (Year) 3 3 Storage pocket for pH electrode Yes - Ingress Protection
Water Tight YES - Impact Resistant Yes - System to be supplied with Measuring electrode combined & glass calomel
temperature probe
Electrode Stand
calibration buffer and maintenance kit
operation manual
power cable and plug Yes - CERTIFICATIONS Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement
Control
And Laboratory Use General Requirements NA - Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement
Control And Laboratory Use EMC Requirements General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer) NA - Availability Of Test Reports From Central Govt/NABL Approved ILAC Acredited Lab To Prove Conformity To The Specification (Test Reports Are To Be Furnished When Demanded By Buyer) false - Test Report Number NA - 2/3 and Date Name and address of the Lab NA - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rakesh Acharya 304502
Govt college malpura 1 15
450150
GEM/2018/B/63640
pH Meter
15 days
Rajasthan; Tonk
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| pH Meter Average Turn Over of Last 3 Years 1 Lakh (s) Experience with Gov. Required 5 Year (s) PH Meter ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values CONFIGURATION Type Microprocessor Based Microprocessor Based | - | - | - |
| Microcontroller Based Display LED/LCD/Touch Screen | - | - | - |
| 3 digits - Calibration up to 3 points with auto buffer - pH Range (pH) 0.00 to 14.00 - Accuracy (pH) +- 0.05 +- 0.05 Corrosion Resistant Yes - Power Requirements 230 V +- 10 | - | - | - |
| 50 Hz AC - Modes pH mV- C - Parallel temperature indication Yes - Temperature Compensation Type Automatic Automatic | - | - | - |
| Manual Temperature Accuracy (Degree C) +- 0.3 +- 0.3 Temperature Compensation Range (Degree C) 0 to 100 - 1/3 Resolution (pH) 0.01 - Operating Humidity: RH in (%) 40 - Operating Temperature (Degree C) 20 - Warranty Warranty (Year) 3 3 Storage pocket for pH electrode Yes - Ingress Protection | - | - | - |
| Water Tight YES - Impact Resistant Yes - System to be supplied with Measuring electrode combined & glass calomel | - | - | - |
| temperature probe | - | - | - |
| Electrode Stand | - | - | - |
| calibration buffer and maintenance kit | - | - | - |
| operation manual | - | - | - |
| power cable and plug Yes - CERTIFICATIONS Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement | - | - | - |
| Control | - | - | - |
| And Laboratory Use General Requirements NA - Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement | - | - | - |
| Control And Laboratory Use EMC Requirements General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer) NA - Availability Of Test Reports From Central Govt/NABL Approved ILAC Acredited Lab To Prove Conformity To The Specification (Test Reports Are To Be Furnished When Demanded By Buyer) false - Test Report Number NA - 2/3 and Date Name and address of the Lab NA - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rakesh Acharya 304502 | - | - | - |
| Govt college malpura 1 15 | - | - | - |
Exempted
11 Aug 2018
8 Aug 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_450150.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .