Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-AOC | ₹23.7 L Quoted ₹25.1 L | L1 | Accepted-AOC L1 |
| 2 | L2₹25.8 L+₹72,746 (2.90%)Rejected-Finance | ₹25.8 L+₹72,746 (2.90%) | L2 | Rejected-Finance L2 |
| 3 | L3₹26.8 L+₹1.7 L (6.58%)Rejected-Finance PLOT NO 8 5179 SAILASHREE VIHAR CHANDRASEKHARPUR BHUBANESWAR DIST KHURDA ODISHA 751 021 | KHORDHA | ODISHA | 751021 | ₹26.8 L+₹1.7 L (6.58%) | L3 | Rejected-Finance L3 |
| 4 | L4₹28.6 L+₹3.5 L (14.0%)Rejected-Finance INDEX NO D 381 HQ CE EC KOLKATA CAMP INS CHILKA PO NB CHILKA DIST KHORDHA ODISHA 752037 | KHORDHA | ODISHA | 752037 | ₹28.6 L+₹3.5 L (14.0%) | L4 | Rejected-Finance L4 |
| 5 | L5₹29.6 L+₹4.5 L (18.0%)Rejected-Finance | ₹29.6 L+₹4.5 L (18.0%) | L5 | Rejected-Finance L5 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
22 Aug 2022, 6:00 pmClosed
GE PROJECTS NAVY VIZAG
Garrison Engineer Project Navy Vizag, HQ CE Navy Complex, Station Road, Visakhapatnam, Andhra Prtadesh-530004.Tele 0891-2546410, 2543670
8792/E8 REPAIR/ REPLACEMENT OF CHAIN LINK FENCING, BARBED WIRE FENCING, COMPUND WALL, RETAINING WALL, DRAINS, PAVER BLOCKS, CHEQUERED TILES, KERB STONE ETC TO FOOT PATHS AND APPROACHES AND OTHER CONNECTED ITEMS AT NAD SUNABEDA, ODISHA
2022_MES_533263_2
8792/E8
Open Tender
Civil Works
Item Rate
AGE Sunabeda
as per NIT/tender documents
6 documents required · 6 mandatory
₹500
Yes
GE P NAVY VIZAG
₹60,000
Yes
29 Sept 2022
25 Jul 2022
24 Aug 2022
25 Jul 2022
22 Aug 2022
9 Aug 2022
25 Jul 2022 - 9 Aug 2022
Amount
Demolition of brickwork or RR masonry including boulder pitching, complete all as specified & directed by Engineer-in-Charge.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted stone masonry built in cement mortar (1:6) for retaining wall and drain wall complete all as specified and as directed.
All as per description of serial item No. 02.00 above but except stone and removing mortar from and cleaning stones, obtained from masonry of any description (except ashlar facings and dressed stone work) and stone setts from pavings; stacking for measurement including all extra handling and removal and disposing off rubbish complete all as specified and as directed by Engineer-in-Charge. Note:- Old stone obtained from demolition shall be used under this item.
M&L flush pointing to random rubble masonry, uncoursed or brought upto courses stone masonry in cement mortar (1:4) all as specified & as directed.
M&L for Brick work with fly ash bricks straight or curved on plan exc 6m mean radious built in CM (1:6) etc complete all as specified and directed.
M&L for PCC (1:3:6) type C-1, using 20mm graded stone aggregate as in coping including use and waste of form work (straight or curved) all exposed surface of concrete finished rough complete all as specified.
M&L for Rendering 10mm thick on external wall brick work or concrete surfaces in cement mortar 1:4, including finishing even and smooth without using extra cement, complete all as specified and directed.
Dismantling fencing wire mesh of any type of any description fixed to any type of fencing posts complete all as specified and directed.
Supply only mild steel galvanized chain link fencing of GI mesh wire, any size and type confirming to IS-2721-1979, complete, all as specified and directed by Engr-In-Charge. Note:- Flat iron, round bars, nut bolts and washer shall be measured and paid for separately.
Fixing only mild steel galvanized chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc. including provision of binding wire. Note :- Supply only chain link fencing shall be measured and paid for separately.
Dismantling RCC posts or struts (wood steel or RCC) any section embedded in natural ground including taking out embedded portion and making good disturbed ground complete all as specified and directed. Note : Dismantling of existing galvanized iron steel barbed wire / Chain link fencing shall be measured & paid for separately.
Excavating in post holes (or similar holes) each not exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface in hard/dense soil.
M & L for PCC (1:2:4) type B1, using 20mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed as directed by Engineer-in-Charge.
M & L for precast reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) as in posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area exc 100 sq. cm but n.exe 250 Sq. cm with or without chamfered angles and flat, splayed, rounded or mitred tops including neccessary formwork as directed and fixed complete all as specified and directed as directed by Engineer-in-Charge.
M&L for mild steel TMT bars 10mm dia & over cut to length bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and bending with and including MS wire (annealed) not less than 0.9 mm dia, complete, all as specified and directed.
All as per serial item No. 15 here-in-above but 6mm to 8mm dia.
Supply and fixing mild steel round bars of 10 mm dia and over conforming to Grade E-250 (Fe 410W) for fixing in chain link wire fencing, including necessary cutting bending etc complete all as specified & directed.
S & F for rolled flats for securing mesh as fencing post strut bend to shape holes drilled notches cut to receive MS bolts and barbed wire, embedded to concrete including tarring to steel work embedded to concrete necessary welding etc. conforming to Gde E-250 (Fe 410-W) quality `A’ ISI marked (IS-2062) complete all as specified & directed.
S & F for Mild steel bolts nut washer (Machine made) with hexagonal head one end and screwed the other, or screwed both ends; each screwed end to be fitted with two washers and one nut hexagonal dia of shank n.exc 12mm and length of bolt exc 50mm but n.exc 100mm complete all as directed.
S&F in repairs galvanized 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanized mild steel wire, staples or steel pins etc, complete, all as specified & directed.Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment.
Restraining & resecuring of galvanized 2 strand steel barbed wire including making good staples etc as directed (each line wire to be measured)
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level.) & removing unserviceable materials n exe 50mtr and depositing where directed at a level not exe 1.5mtr above starting point complete, all as directed by Engr-in-Charge.
M&L for PCC (1:2:4) type B-1, using 20mm graded stone aggregate as in surface channel and drains complete all as specified and as directed.
M&L for preparation of new or previously untreated steel and iron surfaces of any description not exceeding 10 cm in width or girth and applying two coat of synthetic enamel paint ( Ist quality) over a coat of red oxide primer complete all as specified and directed.
M&L for 100mm thick,cement concrete type B-1 (1:2:4), using 20mm graded granite stone aggregate as in paths finished with even and smooth without using extra cement, complete all as specified and directed by Engineer-in-charge.
M&L for Forming construction joints 30mm deep x 10mm wide filled with sealing compound grade `A', complete all as specified.
Dismantling of stone slab and tiles of any description or thickness in floor aprons etc laid bedded and pointed in any mortar complete all as directed.
M&L for 75 mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even complete all as specified and as directed.
M&L for 80mm thick factory made machine pressed cement concrete interlocking paver block of M40 grade confirming to IS 15658-2006, made by block making machine with strong vibratory compaction, of approved shape, size, colour and pattern, laid over and including 50mm thick compacted bed of coarse sand including watering, jointed, pointed in grey cement and pigment, complete all as specified. Make: NATIONAL / NITCO/NIMCO / METRO / VITCO / ULTRA / ANJALI / TERRA FIRMA / Mehtab Tiles
M&L screed bed or bedding layer of cement mortar (1:6), 20mm thick for laying floor finishes etc complete all as specified and as directed by Engineer-in-Charge.
M&L for prepolished chequered cement concrete tiles with grey cement & pigment of size 30cmx30cmx22 to 25mm thick, shape and colour approved by the GE, highly abrasive and skid resistant, impact resistant, chemically treated, ISI marked (IS 13801) compressive strength of 300 Kg/Sqcm laid in floor, set, jointed & pointed with neat cement slurry with white cement mixed with colour pigment to match with the tiles complete all as specified and directed by Engineer-In-Charge. Make: NATIONAL / NITCO/NIMCO / METRO / VITCO / ULTRA / ANJALI / TERRA FIRMA / Mehtab Tiles
M&L for providing cast-in-situ cement concrete type B-1, 1:2:4, (using 20 mm graded granite stone aggregate) as in kerb stone and the like, including necessary formwork, rounded or chamfered on edges, complete all as specified.
M/s Jai Sree Hari
SMART ENERGY SOLUTIONS
M/S SRI SAI SRINIVASA CONSTRUCTIONS
M/S SANTOSH SATAPATHY
M/S JANAKI ENTERPRISES
VARADHI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .