Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.4 LAccepted-AOC WZ 88A JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | L1 | Accepted-AOC Awarded | |
| 2 | L2₹32.7 L+₹2.2 L (7.24%)Rejected-Finance | L2 | Rejected-Finance Rejected |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
27 Jul 2023, 6:00 pmClosed
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
AMC OF AUTOMATON OF WATER SUPPLY INSTALLATION AT CAMERO AREA AND WAC AREA OF AGE E MII UNDER GE (AF) SUBROTO PARK
2023_MES_607440_1
GE/SP/ TOKEN-46/2023-24
Open Tender
Civil Works
Item Rate
330 days
Subroto Park Delhi Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹88,000
Yes
25 Nov 2023
30 Jun 2023
3 Aug 2023
30 Jun 2023
27 Jul 2023
15 Jul 2023
Amount
Maintenance and Servicing of PLC based control panels with its all connected accessories excluding spares parts but including regular maintenance and repair of the Automatic water supply system, installed at various location at Subroto Park including monitoring of main controlling system (Master Panel at Main Pump House) and attending the sites complaints breakdown of system like pump house electric supply , water supply related problem and carrying out maintenance and repair work as per site requirement with rectification of the complaint with in the time period complete and including operating and testing all type of equipments related to water suppy system installed under GE (AF) Subroto Park area complete as per following mentioned installations to the entire satisfaction of the Engineer-in-charge complete all as specified & as directed by Engineer-in-Charge. Equipments:- (i) PLC based Master Control Panel installed at Main Pump House, Subroto Park. (ii) PLC based Slave Control Panel installed at 2 Lakh Gallon & 50k Gallon OHTs, Subroto Park. (iii) PLC based Slave Control Panel installed at 2 Lakh Gallan OHT, Subroto Park. (iv) PLC based Slave Control Panel installed at Palam P/H, Subroto Park. (v) PLC based Slave Control Panel installed at Sabzi Mandi P/H Subroto Park. (vi) PLC based Slave Control Panel installed at Fire Fighting P/H, Subroto Park. Note:- Complaints will be attended by highly skilled workers by OEM minimum 5 times and up to 7 times per month.
All as per item No.1 above but for following mentioned installations complete all as specified & as directed by Engineer-in-Charge Equipments:-(i) PLC based Master Control Panel installed at MAP-II Pump House (Subroto Park). (ii) PLC based Slave Control Panel installed at WO Block (Subroto Park).(iii) PLC based Slave Control Panel installed at OR Block (Subroto Park). (iv) PLC based Slave Control Panel installed at Officer's Block (SPE area Subroto Park).Notes for item No 1 & 2 above:-(a) New parts if any required for repairs and replacement shall be measured and paid separately under items below.(b) Unit rate quoted by tenderer includes checking of system fortnightly and necessary monitoring,servicing, repair, maintance the systematicaly.(c) Specific emergency complaints from time to time shall be attended Immediately after receiving the same.(d) The scope of work includes the charges required for minor repairing, and carrying out electrical connection, termination and fixing and installing, testing, commissioning, etc and all as specified and directed by EIC(e) The work has to be carried out through authorisied OEM or through the authorized service provider of the OEM or any other agency dealing with the installation and maintenance of SCADA / Automation systems and have vast experience i.e.(i) Should have completed one similar work of value minimum 80% of estimated cost as mentioned in NIT in last five years. OR(ii) Should have completed two similar works of value minimum 50% of estimated cost as mentioned in NIT in last five years. OR(iii) Should have completed three similar works of value minimum 40% of estimated cost as mentioned in NIT in last five years.(iv) "Similar work means the work of installation of SCADA system or repair and maintenance of SCADA system".(f) A copy of MOU with OEM/Service provider of the OEM/agency dealing with SCADA/automation systems alongwith proof of similar work completed is required to be uploaded with the tender bid (g) The labour element required for maintenance, servicing, repair of automatic water supply system and various locations installed at subroto park and replacement of defective parts with new parts and making the system operational including all necessary testing is included in the rate quoted for this item. Note:- Complaints will be attended by highly skilled workers by OEM minimum 5 times and up to 7 times per month.
Maintenance & Servicing of Pressure Switches (25 Nos) by disconnecting electrical connection, dismantling, cleaning, refixing and re-connecting with Teflon tape , installation, commissioning and testing to ensure the equipment is runnig properly and smoothly complete all as specified & as directed by Engineer-in-Charge. . Note:- Complaints will be attended by highly skilled workers by OEM minimum 5 times and up to 7 times per month.
All as per item No. 3 above but for magnetic float switch sensors (145 Nos) complete all as specified & as directed by Engineer-in-Charge. .
All as per item No.3 above but for Solenoid Valves (44 Nos) complete all as specified & as directed by Engineer-in-Charge.
All as per item No.3 above but for electrical actuator suitable for line size 200mm dia (11 Nos), 150mm dia (43 Nos), 100mm dia (09 Nos) and 50/80mm dia (26 Nos) complete including oiling & greasing all as specified & as directed by Engineer-in-Charge.
Maintaining the communication part, and establishing communication as required, including cost of communication for eleven months including monitoring and control of the Pump House through individual PLC based slave Panels and overall control through PLC based Master Panel complete all as specified & as directed by Engineer-in-Charge. NOTE FOR ITEM NO 3 TO 7 : -(a) The work has to be carried out through OEM or through the authorized service provide of the OEM or any other agency dealing with the installation and maintenance of SCADA / Automation systems and have vast experience i.e.(i) Should have completed one similar work of value minimum 80% of estimated cost as mentioned in NIT in last five years. OR (ii) Should have completed two similar works of value minimum 50% of estimated cost as mentioned in NIT in last five years. OR (iii) Should have completed three similar works of value minimum 40% of estimated cost as mentioned in NIT in last five years.(iv) "Similar work means the work of installation of SCADA system or repair and maintenance of SCADA system". (b) New parts/ accessories required for maintenance & servicing of Pressure switches, Magnetic float switch censors silenoid vaves electrical actuater communication system shall be measured and paid separately. (c) Unit rate quoted by tenderer includes checking of system fortnightly and necessary monitoring,servicing, repair, maintance the systematicaly.(d) Specific emergency complaints from time to time shall be attended Immediately after receiving the same.(e) The scope of work includes the charges required for minor repairing, and carrying out electrical connection, termination and fixing and installing, testing, commissioning, etc and all as specified and directed by EIC(f) A copy of MOU with OEM/Service provider of the OEM/agency dealing with SCADA/automation systems alongwith proof of similar work completed is required to be uploaded with the tender bid(g) The labour element required for maintenance, servicing, repair of automatic water supply system and various locations installed at subroto park and replacement of defective parts with new parts and making the system operational including all necessary testing is included in the rate quoted for this item. (h) Panel reovery of Rs 500.00 per complaint per day for not attending complaints within 24 hours. . Note:- Complaints will be attended by highly skilled workers by OEM minimum 5 times and up to 7 times per month.
Supply only for replacement PLC (Programmable Logic Controller) comprissing of main controller, MMI with display, input / output and consist of following specifications complete all as specified and as directed by Engr-in-Charge : (a) MMI with 2line LCD display and 15 sealed membrane keys, expansion adaptors, input / output modules / communication ports : 3 Nos (b) Power Supply : 24 Volt DC / Permissible range : 20.4 V DC to 28.8 V DC with less than 10% ripple / digital input : 22 pnp (source) or npn (sink) / digital outout : 16 pnp (source) / I/O (c) Module Capacity : 8 / Operating Temperature : 0 deg to 50 deg / storage temperature : -20 deg to 60 deg / environment protection : IP 20.
Supply only for replacement Single Phase Preventor complete all as specified and as directed by Engineer-in-Charge.
Supply only for replacement Relay with base 240V, AC complete all as specified and as directed by Engineer-in-Charge.
Supply only for replacement Relay with base 24V, DC complete all as specified and as directed by Engineer-in-Charge.
Supply only for replacement Healthy Lamp complete all as specified and as directed by Engineer-in-Charge.
Supply only for replacement electric motor suitable for actuator for 200mm dia motorised butterfly valve complete all as specified and as directed by Engineer-in-Charge.
Supply only for replacement electric motor suitable for actuator for 150mm dia motorised butterfly valve complete all as specified and as directed by Engineer-in-Charge.
Supply only for replacement electric motor suitable for actuator for 100mm dia motorised butterfly valve complete all as specified and as directed by Engineer-in-Charge.
Supply only for replacement electric motor suitable for actuator for 80mm dia motorised butterfly valve complete all as specified and as directed by Engineer-in-Charge.
Supply only for replacement electric gear box suitable for actuator for 200mm dia motorised butterfly valve complete all as specified and as directed by Engineer-in-Charge.
Supply only for replacement electric gear box suitable for actuator for 150mm dia motorised butterfly valve complete all as specified and as directed by Engineer-in-Charge.
Supply only for replacement electric gear box suitable for actuator for 100mm dia motorised butterfly valve complete all as specified and as directed by Engineer-in-Charge.
Supply only for replacement electric gear box suitable for actuator for 80mm dia motorised butterfly valve complete all as specified and as directed by Engineer-in-Charge.
Supply only for replacement butterfly valve of size 80mm dia as per exiting sample/ size complete all as specified and directed by Engineer-in-charge.
Supply only for replacement butterfly valve of size 150mm dia as per exiting sample/ size complete all as specified and as directed by Engineer-in-charge
Supply only for replacement butterfly valve of size 200mm dia as per exiting sample/ size complete all as specified and as directed by Engineer-in-charge
Supply only for replacement SMPS 24V DC 6.5 A complete all as specified and as directed by Engineer-in-Charge.
Supply only for replacement Pressure Switch 0-10 kg/sqcm complete all as specified and as directed by Engineer-in-Charge.
Supply only for replacement Limit Switch as exists at site for actuator suitabel for 200/150/100/80 mm dia butterfly valve complete all as specified and as directed by Engineer-in-Charge.
Supply only for replacement Resistance & Capacitor (as exists) suitable for actuator RT-10 complete all as specified and as directed by Engineer-in-Charge.
Supply only for replacement Hand Wheel for actuator (as exists) suitable for 200/150/100/80 mm dia butterfly valve complete all as specified and as directed by Engineer-in-Charge.
Supply only for replacement Buzzer 24V DC complete (as exists) all as specified and as directed by Engineer-in-Charge.
Supply only Relay Card - 1 C/O, 24V DC complete all as specified and as directed by Engineer-in-Charge.
Supply only Relay with base - 2 C/O, 220V AC complete all as specified and as directed by Engineer-in-Charge.
Supply only of Indicator Lamp of colour :- Green/ Red/Yellow, 220VAC/24VDC complete all as specified and as directed by Engineer-in-Charge.
Supply only of Illuminated Push Button (Red/Green) 220VAC/24VDC complete all as specified and as directed by Engineer-in-Charge.
Supply only Illuminated Push Button (Yellow) 220VAC/24VDC complete all as specified and as directed by Engineer-in-Charge.
Supply only 10MM LED 24V DC Indicator Lamp of colour :- Green/ Red/Orange. complete all as specified and as directed by Engineer-in-Charge.
Supply only multi function energy meters with LED Display having CI 1 & inbult RS 485 communication port. Parameters to be taken:- V, A, F, PF, KW, KVA, KWh, KVAh, KVAR, KVARh, RUNHR, ONHR, Interupts, Phase Angle THD, Neutral Current.
Supply only 2 Pole 6/10A MCB complete all as specified and as directed by Engineer-in-Charge.
Supply only 3 Pole 25A MCB complete all as specified and as directed by Engineer-in-Charge.
Supply only Single Pole 6/10A MCB complete all as specified and as directed by Engineer-in-Charge.
Supply only PLC Card with 16 Digital Input, Future expandablity to HARD Communication to identify instrument fault over SCADA as smart.
Supply only PLC Card with 32 Digital Output, Future expandablity to HARD Communication to identify instrument fault over SCADA as smart.
Supply only PLC Card with 4 Analog Input, Future expandablity to HARD Communication to identify instrument fault over SCADA as smart.
Updating existing PC based master control station. The scope includes:- Services for programming, configuration and customisation of the Smart Station Platform with respect to the Water supply Module as per actual site conditions and requirement of the engineer. (a). Landing Page to depict criritcal paramters viz. - Level of water in all tanks, pump status ON/OFF/FAIL and Water Quality parameters (b). Creation of drop down tabs to monitor the all Pump houses and Remote PLC Panel systems individually (c). Creation of individual PLC Panel wise schematics and layouts for the Water Supply system as per the actual site including display of all relevant parameters viz. Water level, Pump ON/OFF/FAIL status, Valve OPEN/CLOSE/FAIL status (d). Soft keys for remote manual operation of all pumps and motorised valves from the Master Control station. (e). Creation of Day wise Reports for :- (i) Run hours of pumps (ii) Pump / valve operation faliures (iii) Active/Return status of each equipment with date and time. (iv). Configuring notifications, alerts and alarms as per preset logic. (v) Consumption Patterns - Daily, Weekly, Monthly and Annually.
Rewiring of PLC based control panel along with establishing Ladder Logic Programming of the PLC / Relay Logic of Slave Automation Panel installed as directed by Engineer-in-Charge.
Supply, Installation, testing and Commissioning of 80 mm dia, single phase, Motor Actuated Butterfly valve with disc material SS - 304, Stem Material SS - 410, Seat EPDM, hand wheel for manual operation and having 05 nos. limit switches for Open / Close condition, valve position indicator and over ride trip. The housing of actuator should be of Aluminium Dicast. The mounting shall be direct on valve type. Input Voltage: 230 V, A.C. Designed line pressure: 16 kg/sq cm. The mounting shall be direct type using specialized arrangement of GI pipe of suitable size/thickness, complete all as specified and directed.
Supply, Installation, testing and Commissioning of 80 mm dia, single phase, Motor Actuated Butterfly valve with disc material of SS-304 & stem material of SS-410, with EPDM seat & nylon coating, hand wheel for manual operation and having 05 nos. limit switches for Open / Close condition and valve position indicator.The mounting shall be indirect on valve type and provided with top cover for actuator made out of CRCA sheet. Input Voltage: 230 V, A.C. Designed line pressure: 16 kg/sq cm. The mounting shall be indirect type using specialized extended type arrangement of GI pipe of suitable size/thickness, so that actuator mounting is at least 6 inches above ground level complete all as specified and directed.
Supply, Installation, testing and Commissioning of 150 mm dia, single phase, Motor Actuated Butterfly valve with disc material SS - 304, Stem Material SS - 410, Seat EPDM, hand wheel for manual operation and having 05 nos. limit switches for Open / Close condition, valve position indicator and over ride trip. The housing of actuator should be of Aluminium Dicast. The mounting shall be direct on valve type. Input Voltage: 230 V, A.C. Designed line pressure: 16 kg/sq cm. The mounting shall be direct type using specialized arrangement of GI pipe of suitable size/thickness, complete all as specified and directed.
Supply, Installation, testing and Commissioning of 150 mm dia, single phase, Motor Actuated Butterfly valve with disc material of SS-304 & stem material of SS-410, with EPDM seat & nylon coating, hand wheel for manual operation and having 05 nos. limit switches for Open / Close condition and valve position indicator.The mounting shall be indirect on valve type and provided with top cover for actuator made out of CRCA sheet. Input Voltage: 230 V, A.C. Designed line pressure: 16 kg/sq cm. The mounting shall be indirect type using specialized extended type arrangement of GI pipe of suitable size/thickness, so that actuator mounting is at least 6 inches above ground level complete all as specified and directed.
Supply, Installing,Testing and Commissioning of Ultrasonic Level Transmitter at Sump and overhead tank for measurement of level with following specification:- Range : 0-8 meters Accuracy : 0.5 % minimum Supply Voltage : 24V DC Output : 4-20 mA , 0-10V DC
Supply, Installation, Testing, Commissioning and Programming of Metal Reflector Parabolic antenna with control station to generate strong directional effect with WLAN network support having mast mounting arrangment. Control station should operate on license free frequency with necessary hardware at a suitable location to be connected to the central scada server so as to establish connectivity with every station of the network after conducting a frequency survey of the entire area of interest and identify suitable locations to mount the station hardware and the height of the antennas to establish clear line of sight either directly or by multi hop so as to be able to send data. Antenna type:- Metal Reflector Antenna Degree of protection:- IP65 Mounting type:- Mast mounting The should have a approval of Wi-Fi compliance, Environmentally Friendly Use Period :- UNLIMITED = EFUP-e Note:-Rate quoted is deemed to be included for making arrangemets of accessories such as mounting bracket and mast clips
Supply, installation, testing, and commissioning of Solenoid Valve 10mm/12 mm dia 230 V AC, Brass or stainless steel body, direct acting / diaphragm type, pilot operated Solenoid Valve for air release with manual bypass arrangement along with all necessary installation accessories like gate valve, barrel piece, double nipple, elbows/bends etc with following specification:- (a) Size:- 12mm (b) Designed line pressure:- 0.5 to 10 bar (c) Body Material:- Stainless Steel / Brass (d) Coil Power:- 6W
Supply, installation, testing, and commissioning of Solenoid Valve 20mm/ 25 mm dia 230 V AC, Brass or stainless steel body, direct acting / diaphragm type, pilot operated Solenoid Valve for air release with manual bypass arrangement along with all necessary installation accessories like gate valve, barrel piece, double nipple, elbows/bends etc with following specification:- (a) Size:- 25mm (b) Designed line pressure:- 0.5 to 10 bar (c) Body Material:- Stainless Steel / Brass (d) Coil Power:- 6W
Supply, installation, testing, and commissioning of Pressure Transmitter with proper wiring including necessary power pack for supply of DC :- Power supply: 10-36 V DC Enclosure: whether proof IP 65 Process temperature: -30 to 120 Celsius Accuracy: 0.25 %
Taking down old unserviceable and Supply, Installation Testing & Commissioning of Programmable Logic Controller with 8 Digital Input, 4 Digital Output and Expandable upto 192 DI / DOs, 1 Nos. RS 485 communication port, 1 Nos. Ethernet communication port, MODBUS compatiblity, Future expandablity to HARD Communication to identify instrument fault over SCADA as smart.
Repair/ Replacement, installation, maintenance,servicing, programming, testing and operationalization of ARM/AMI enabled Ultrasonic water flow meter for pipe of size 150mm, Pn16, Class2 , IP68 3.6VDC lithium battery, ISO4064, Rs485 Strong and rugged body for tougher duty, tampered proof,alarm system, smart design using ultrsonic sensing technology, no moving part , LCD ON display with steamless consumption data display.
Supply and laying for replacement PVC insulated PVC sheathed copper armoured cable of size 1.5 sqmm 6 core laid in trenches / wall / ceiling and roof of OH tanks / OH Pillars etc. complete all as specified and as directed by Engineer-in-Charge.
Supply and laying for replacement PVC insulated PVC sheathed copper armoured cable of size 1.5 sqmm 4 core laid in trenches / wall / ceiling and roof of OH tanks / OH Pillars etc. complete all as specified and as directed by Engineer-in-Charge.
Supply and laying for replacement PVC insulated PVC sheathed copper armoured cable of size 1.5 sqmm 2 core laid in trenches / wall / ceiling and roof of OH tanks / OH Pillars etc. complete all as specified and as directed by Engineer-in-Charge.
Supply and laying for replacement PVC insulated PVC sheathed copper armoured cable of size 0.5 mm 5 pair telephone cable complete all as specified and as directed by Engineer-in-Charge.
Supply, Installation, Testing and Commissioning of 4 pair CAT 6 UTP shielded cable for communication.
Supply and laying on wall/ground 25 mm dia GI pipe as required
Supply and laying on wall/ground 50 mm dia GI pipe as required
Excavation in trenches in any type soil /rock (soft/loose/hard/dense soil/rock) n.exe 1.5 mtr wide and n.exe 1.5 mtr in depth for foundation laying of pipe etc n.exe 10 sqmm on plan and n.exe 1.5 mtr in depth and getting out complete all as specified and as directed by Engineer-in-charge. NOTE : While removing the pipe line. Contractor shall replaced the broken tiles with new as per existing . The quoted rates including for all the materials / t&p / machinery used in this item no material can paid / measured seperately
Returning filling in including spreading levelling watering and well ramming hard / dense soil in layers not.exe 25cm each layers complete all as specified and as directed by Engineer-in-charge
Removal of excavated material & surplus spoil to a distance n.exe 50 mtr and depositing where directed at a level not exe 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-charge
M & L for sand cushioning using fine sand (Jamuna dry and clean sand) for cable protection, in two layers, first layer of 80mm thick before laying of cable and second layer 150mm thick after laying of cable and punned down to 180 mm all as specified in clause No 19.75 of SSR Part I complete all as specified and as directed by Engineer-in-charge.
M&L for laying sub class ‘B’ bricks for cable protection laid perpendicular to direction of the cable over sand cushioning complete all as specified and as directed by Engineer-in-charge.Note for Srl item Nos 9 to 45 of BOQ :- The rate quoted for item No.9 to 44 is for supply only of items mentioned against each. Cost of fixing including necessary tools & plants for items supplied under the above items is deemed to be included in rates quoted for maintenance repairs & servicing of respective Srl item Nos. 1,2,3,4,5,6,7 of BOQ. Tenderers shall take note of this condition while quoting of tender. No extra shall be admissible on this account and the system shall be kept operating & fully functional all the entire satisfaction of Engr-in-Charge.
D P ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .