Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹22.6 L
Closing Date
27 Oct 2021, 4:00 pmClosed
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2021_PWDJK_144685_1
e-NIT No.EDJ/123 of 2021-22 Dated 21-10-2021
Open Tender
Electrical Works
Item Rate
60 days
Raj BHawan Jammu
please refer to NIT
2 documents required · 2 mandatory
₹0
Exempted
28 Oct 2021
21 Oct 2021
28 Oct 2021
22 Oct 2021
27 Oct 2021
22 Oct 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1 x 1.5 sq. mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing
6 way (4 + 18), Double door
8 way (4 + 24), Double door
12 way (4 + 36 , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Single pole and neutral
Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply. including connections etc. as required.
Ceiling fan 1200 mm sweep alongwith upto 1'-6" long rod as required.
Exhaust fan 300 mm size (metalic)
Exhaust fan 300 mm size with louvers
400 mm sweep wall fan
Supplying and fixing of (70 + 5) watt LED Street/flood Light complete with M.S/GI pipe bracket duly embeded along the parapet /wall including complete connections as required.
Supplying and fixing of Ceiling rose
Supplying and fixing of following rating 240/415 Volt's "C" Series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning (Above to 32 Amp.).
SPN 40 Amp
TPN 40 Amp
TPN 63 Amp
Supplying and fixing of 20/22 watt LED 4 feet tube light fitting/fixture aluminium housing with 2000 Lumens and min lumens efficiency 100 Lumens/watt P.F 70.95 THD < 16%.
Supplying and fixing of 600 mm x 600 mm size recessed mounted LED Luminaries 36 watt. having minimum 3600 Lumens with minimum lumens efficiency 115 Lumens/watt.
Providing and fixing of L.T switch gear power control panel floor/Wall mounted Indoor /outdoor (CPRI approved )type totally enclosed, compartmentalized, cubical made of 2mm thick sheet duly powder coated free from dents, dust uneven surfaces and vermin proof (as per technical specifications suitable for 415 volts 3 phase 4 wire 50 HZ AC supply complete with hinged doors having looking arrangment with provision of space for MCCB, Bus Bar, MCB Strips etc as required. The job includes interconnections testing, commissioning and providing earthing connection to panel. (Design of panel has to take from XEN/AEE. The size of panel can be change as per required design.). (6 cft = 1 No., 25 cft = 1 No., 15 cft = 2 No. )
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
MCCB- 400 Amp- 50 KA- FP ICU=ICS=100%
MCCB- 250 Amp- 36 KA- FP ICU=ICS=100%
MCCB FP 160 Amp. 36 KA ICU=ICS=100%
MCCB FP 100 Amp. 30 KA ICU=ICS=100%
Aluminium Bus bar 200 amp 4 strip.
Aluminium Bus bar 300 amp 4 strip.
Aluminium Bus bar 600 amp 4 strip.
Aluminium Bus bar 400 amp 4 strip.
Supplying, Installation, Testing & Commissioning of water storage Heater (Geyser) of following capacity.
Supplying installation testing and commissioning of XLPE insulated and PVC sheathed / power cable of 1.1 KV grade of following size in ground.cable tray as per site conditions as required.
400 sq. mm x 3.5 core Armoured.
185 sq. mm x 3.5 core Armoured.
Supplying, installation, testing and commissioning of 1.5 Ton Split AC's inverter type (copper) (3 star) Hot & Cold type of minimum capacity following sizes as detailed below. Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. Indoor unit must be fitted on wall via clamps while outdoor units on MS powder coated wall stand. Warrantee.:- a). Warrantee shall be provided for 12 month from the date of installations. b). The compressor shall be warranted for 5 years from the date of installation.
Supplying, Installation, Testing & Commissioning of automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary. Warrantee.:- 2 Years from the date of installation.
Supplying & fixing of M.S Wall Stand duly powder coated for outdoor unit of Split AC
Supplying of drain pipe for indoor unit (Supreme) 3/4"
Extra length of copper pipe for outdoor unit and cable of required size
Supplying, installation, testing and commissioning of 150/150 Litres of water Cooler alongwith PVC connecting pipes and suitable automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V as required.
Supply and fixing of Dr. Aquaguard Magna (HDUV)
SV ELECTRICALS
NASEER AHMED
HIRA LAL
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .