Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹80.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Not Admitted-Finance | - | Not Admitted-Finance Not qualified for AOC |
Tender Value
₹68.2 L
EMD Value
₹1.4 L
Closing Date
27 Feb 2020, 3:00 pmClosed
Incharge Civil
SCO 153-55 , SECTOR 34-A, Chandigarh
Construction of Building for Setting up of State Central Dairy Laboratory N A B L Accredited at Verka Mohali Dairy
2020_Coop_43609_1
PSF/CIVIL/1134-34
Open Tender
Civil Works
Item Rate
120 days
CHANDIGARH
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
TIA
₹1.4 L
24 Sept 2021
23 Jan 2020
28 Feb 2020
23 Jan 2020
27 Feb 2020
23 Jan 2020
Amount
SUB HEAD-1 Earth Work.
Earth work in excavation for all type of foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent refilling around masonary etc. in 15 cms layers with compaction/ consolidation, including disposal of all surplus soil as directed , within campus/ site.
Earth filling under floors/in plinth with surplus soil excavated from foundations (as per bove) and taken only from outside the building plinth, in 15cms layers including ramming, watering and consolidating as directed by the Engineer-in-Charge.
Earth filling under floors with approved earth brought from outside (any lead) and filling in 15cms layers including carriage, loading & unloading, ramming, watering and consolidating, complete in all respects as directed by the Engineer-in-Charge.
Providing and filling in plinth and under floors approved local river sand including carriage loading, unloading, spreading, watering, ramming, consolidating, etc. complete as directed by the Engineer-in-Charge.
Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS-6313-2001 (Part-2) & using Chemical containing chloropyrifos systemic insecticide diluted to manufacturer’s specifications i.e. 1 Ltr. of choropyrifos and 19 ltr. water:- (i)In foundation pits, by treating the bottom & sides up to height of 300mm by uniformly spraying solution @ 5 litre per sqm. (ii)In the refill earth on both sides of all built up walls @ 7.5 litre / Running meter (width -300mm, depth -450mm).(iii)Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 litre solution per sqm.
SUB HEAD-2 CENTERING AND SHUTTERING.
Providing and fixing steel shuttering for faces of concrete foundations, footings, strips, pedestals, foundation beam, plinth beams (vertical, or battering) and columns etc. Complete in all respects as directed by E-in-C.
Providing and fixing steel shuttering and centering for RCC columns (square or rectangular or polygonal in plain). Complete in all respects as directed by E-in-C.
Providing and fixing steel shuttering and centering for sides and soffits of beam, beams launchings girders bressumers, lintels etc. Complete in all respects as directed by E-in-C.
Providing and fixing steel shuttering and centering for flat surfaces such as suspended floors, roof, landings, chajjas, shelves, etc including risers. Complete in all respects as directed by E-in-C.
SUB HEAD - 3 CONCRETE WORK
Providing and laying plain cement concrete 1:5:10 using concrete mixture volumetric type with stone aggregate (1 cement: 5 coarse sand: 10 stone aggregate 40mm gauge) for all types of foundations, footings, below rafts, extension columns, plinth beams/under floor etc. including spreading, laying, ramming and consolidating as per requirements and curing etc. but excluding centering and shuttering, complete in all respects as directed by E-in-C. a) In foundations and plinth
Providing & laying Reinforced cement concrete M-25 mechanically mixed (In foundation and plinth) using batch type concrete mixture as per IS 1791 and vibrated by needle vibrator but excluding steel reinforcement, centering and shuttering, for all types of RCC works i.e. column, beams, slabs etc. as per structural drawings/ design including laying, spreading, ramming, watering, consolidating & curing etc., Complete in all respects as directed by the E-in-C..
Providing & laying Reinforced cement concrete M-25 mechanically mixed (In super structure ) using batch type concrete mixture as per IS 1791 and vibrated by needle vibrator but excluding steel reinforcement, centering and shuttering, for all types of RCC works i.e. column, beams, slabs and fascias etc. as per structural drawings/ design including laying, spreading, ramming, watering, consolidating & curing etc., Complete in all respects as directed by the E-in-C..
Providing & laying Damp proof course 40m m thick with machine mixed PCC 1: 2: 4 with two coats of bitumen 25/85 penetration @ 1.65 kg per sqm laid hot and sanded bitumen to applied uniformly and after proper curing of concrete, complete in all respects.
Providing & laying 20 mm thick cement plaster in damp proof course 1:3 with two coats of bitumen @ 1.65Kg. Per sqm laid hot and sanded. Complete in all respects.
Providing and fixing/placing in position Ribbed/Tor/ T.M.T. Steel Bars, for R.C.C. works, where not including in the complete rate of R.C.C. included bending, binding and placing in position as per structural design/ drawing including cost of binding wire. Complete in all respects as directed by the E-in-C.
SUB HEAD-4 BRICK WORK
Providing & constructing Ist Class burnt brick work laid in cement sand mortar 1:6 (1 cement: 6 coarse sand) including scaffolding, watering, curing etc. complete in all respects, as directed by the E-in-C. a ) In foundation and plinth.
Providing & constructing Ist Class burnt brick work laid in cement sand mortar 1:6 (1 cement: 6 coarse sand) including scaffolding, watering, curing etc. complete in all respects, as directed by the E-in-C. In Super Structure.
Providing & constructing 115mm thick brick wall in cement sand mortar 1:4 without reinforcement including scaffolding, watering, curing etc. complete in all respects, as directed by the E-in-C. A) in foundation and plinth
Providing & constructing 115mm thick brick wall in cement sand mortar 1:4 without reinforcement, including scaffolding, watering, curing etc. complete in all respects, as directed by the E-in-C. A) In Super Structure.
Providing & constructing 115mm thick brick wall with every fourth course reinforced with hoop iron laid in cement sand mortar 1:4 including scaffolding, watering, curing etc. complete in all respects, as directed by the E-in-C. A) In Super Structure.
SUB HEAD -5 PLASTERING WORK
Providing and applying minimum 20 mm thick sand face plaster 12 mm thick in CM 1:4 and 8 mm thick C.M 1:2 at all levels laid in two coats to concrete or masonry surfaces and around openings in jambs and sills, including hacking of concrete surfaces, racking of joints, scaffolding, curing, making sharp and clear grooves, pattas, drip moulds, providing and fixing chicken mesh jali (22 gauge) at the junction of two different surfaces material component and at all levels and all heights as detailed in drawings as directed by Engineer in charge, etc. complete in all respects..
Providing and applying 20 mm Thick cement plaster in cement sand mortar 1:5(1cement:5 fine sand) in two coats to the walls, columns etc. including providing groove, drip course, scaffolding, finishing, curing etc. Complete in all respects for all heights as directed by the E-in-C.
Plastering on under side of ceiling 10mm thick cement plaster 1:4including saffolding, finishing, curing etc. Complete in all respects for all heights as directed by the E-in-C.
Providing and fixing chicken mesh on brickwork and R.C.C. work junction made of galvanized low carbon wire, annealed wire of diameter 0.6 to 2.0 mm, distance between the faces of the hexagon 13 to50mm complete in all respects.
Providing surface treatment to externa/ internal walls with water resistant grade, anti fungal, antifoaming, high percentage acrylic binder washable surface with two coats to be provided with saptula over one coat cement primer including preparation of surface with water resistant grade match colour complete as per specifications and to the entire satisfaction of E-in-C.
Providing and fixing UNI- Brick tiles smooth size 230x40mm, 12mm thick ( Red color ) unistone or equvalent clading on walls ( design/ make tobe got approved before arranging) in specified pattern laid in 12.5mm thick cement sand mortor 1:3 ( 1 cement :3 sand) and jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and polshing wherever required complete in all respects as driected by E-in-C.
SUB HEAD-6 ROOFING
Providing and laying Terracing to proper slope consisting of brick tiles 22.86cm x 11.43cm x 3.83cm laid over 25mm mud plaster, 75mm mud filling on another layer of 25mm mud plaster including two coats of bitumen grade 85/25 laid hot @ 1.65kg/M2 on top of RCC slab, including grouting with cement sand mortar 1:4 (1 cement:4 course sand) and top surface to be left clean after wire brushing etc. Complete in all respects as directed by the E-in-C.
Extra for providing and applying flush cement pointing 1:2 (1cement: 2 sand) to tile terracing. Including curing etc. Complete in all respects as directed by the E-in-C.
Providing and laying cement concrete 1:2:4 gola 10cm. X10cm. concave quadrant along junction of roofs with parapet wall, finished smooth where specially specified, complete in all respects as directed by the E-in-C.
Providing and constructing Bottom khurra on ground 1.2M x 0.6M consisting of brick on-edge laid in cement sand mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3 complete in all respects as directed by the E-in-C.
Providing and constructing Top khurra 0.6M x 0.6M for Rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16, complete in all respects as directed by the E-in-C.
Providing and fixing 110 mm dia SWR U.P.V.C Rain water pipe (ring fitted type-A) as per IS:13592 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-incharge. (If fixed on wall face clamp to be paid separatly as per respective item)
Providing and fixing 110 mm dia SWR U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Providing and laying 2’-6’’ wide plinth protection consisting of 2’-3’’ wide brick on edge laid in cement sand mortar 1:4 on 75mm thick cement concrete 1:8:16 and 100mm thick sand filling and cement pointing 1:2 on top including excavation re-filling and disposal of surplus earth within campus.
SUB HEAD-7 FLOORING
Providing and laying vitrified tiles of Size 600 x 600 mm in flooring of light colour and shade ( to be got approved before arranging) made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 ( Make Kajaria /Johnson/Naveen diamond equivalent approved make ) in all colours and shades, laid on 20mm thick cement sand mortar 1:4 (1 cement: 4 fine sand), (Design is homogenous throughout the tile body). complete in all respects.
Providing and laying vitrified tiles of Size 600 x 600 mm in skirting/dado of light colour and shades ( to be got approved before arranging) made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 ( Make Kajaria /Johnson/Naveen diamond equivalent approved make ) in all colours and shades, laid on 20mm thick cement sand mortar 1:4 (1 cement: 4 fine sand), (Design is homogenous throughout the tile body). complete in all respects.
Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete complete in all respects.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete in all respect as directed by the E-in-C.
Providing and fixing kotah stone tile flooring 20mm to 30mm thick over 12.5mm thick base of cement mortor 1:3 laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone, including rubbing nd polishing complete in all respects.
Providing and fixing kotah stone tile 20mm thick in skirting, risers of steps, dado to walls and pillars, over 12.5mm thick base of cement mortor 1:3 laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone, including rubbing nd polishing complete in all respects.
P/F colored granite stone tiles 15 to 20mm thick in skirting, trend & risers of steps, dado to walls and pillars, over 12.5mm thick base of cement mortor 1:3 laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone, including rubbing nd polishing complete in all respects.in
Providing and laying 80 mm thick factory made cement concrete interlocking paver block of M-40 grade rubber moulded smooth finish with strong vibratory process and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge.
P/F plain cement concrete M-20 grade precast kerb 250mm high with bottom width 165mm and top width 115mm fixed in position on earth base including carriage to site of work, complete in all respects
P/F plain cement concrete M-20 grade precast channel 300mm wide and 75mm thick fixed in position on earth base including carriage to site of work, complete in all respects.
SUB HEAD-8 GLAZING & JOINERY
Providing and fixing all types of colour coated aluminium work for doors/ sliding, etc. windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/ neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge
a) For fixed portion and chaukhats
b) For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and necessary Alumn. fittings wherever required including the cost of PVC Plug / neoprene gasket etc. complete in all respects as directed by the E-in-C.
Extra for providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides. Complete in all respects as directed by the E-in-C.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.
SUB HEAD-9 PUBLIC HEALTH ( WATER SUPPLY, SAINTRY AND DRAINAGE )
Providing and fixing SWR UPVC Floor traps conforming to I.S.I.14735 Specification of reputed firm of the self cleaning design with C.P. brass hinged grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors,etc. minimum depth of water should be 150mm with a minimum seal 50mm. Complete in all respects as directed by the E-in-C.
a) Floor trap 75mmx75mm
b) Floor trap 110mmx75mm
Providing and fixing in position SWR UPVC gully trap 100mm dia fixed in cement concrete 1:4:8 complete with P.V.C. grating 150x150mm cast iron cover weighing 7.26 kg Frame for clear opening size 300x300mm & outside 330x330 mm and chamber including cost of all brickwork in cement mortar 1:5, cement concrete 1:2:4 in coping around C.I. Cover and frame etc. with 3 coats of black bitumastic paint of approved quality/make on C.I. Work as per standard design minimum depth of water should be 150mm and minimum seal 50mm, complete in all respects.
Providing and fixing in position SWR UPVC. soil waste vent or antisyphonage pipes as per IS: 13592 of approved make ( to the approval of Engineer -In -charge) including cutting, jointing and wastage etc,complete as directed to the entire satisfaction of E-in-C.
i)110mm dia o/d pipe.
ii) 90 mm dia pipe
iii)75 mm dia pipe
P/F in position Chinaware ( white colour ) wall hunged Euopean tpe water closet suite single syphonic type ( make Hindware/Cera/ Perryware ) with P- Trap or S- trap ( to the approval of E-in-C) with 10 ltr chinaware maching flushing cistren including the cost of solid waste cover and Lid complete in all respects to the entire satisfaction of Engineer In Charge.
Providing & Fixing in postion Acrylic liquid soap container of best quality as directed by the Engineer-in-charge.
Providing and fixing in position CERA make vitreous chinaware urinal snow white model cicly 5025 of size 320mx300mm x325mm) senso urinal including sensor. Complete in all respects as driected by E-in-C.)
Providing and fixing partitions for urinals with 17mm to 20mm thick marble partitions 375mmx 750mm. Complete in all respects as directed by E-in-C.
Providing & Fixing in position 6mm thick mirror (make ASAI/SAINT GOBIN OR equalent approved quality) with necessary fittings /fastners complete in all respects as directed by the E-in-C.
Sub Head -10 Sewrage
Excavation manually in trenches with straight or open cutting in built up street lane having wall to wall width of street /lane upto 3.0 metre, for intramural sullage drains, extramural intercepting drains and outfall drains, storm water channels and other work contingent or incident thereto, to full dimensions and depth as shown on the drawings or as shall be required by Engineer- in-chargeIncluding dressing to correct sections and dImensions according to templates and levels, dewatering of rain water, diversion of traffic. Providing and fixing and maintenance of caution boards, fencíng, night signals, for leads upto 15m and for all lifts and subsequent refilling,watering and dressing upto ground level, including removal of surplus soil from the site upto 15 metre distance complete in all respects
Providing, lowering, cutting & jointing salt Glazed Stone ware Pipes and Specials ISI marked as per IS 651-2007 class Sp-1 into trenches for all depths and Laying out the same to correct alignment, gradients, levels etc., In trenches including all dressing and trimming of bed and sides of trenches, if required trimming and cutting of concrete beds and joints holes, supporting the pipes and specials, in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benching, haunching and envelopes are completed including jointing of pipes and specials in trenches, using cement sand mortor 1:1 and best jute spun yarn, finshing and troveling of each joint at an angle of 45 degree with the longitudinal axes of pipe, watering, keeping the joint covered wet till the same are cured , testing the sewerage line for leakage and making all the leakage and defects good complete all respects.
a) 100mm i/d pipes
b) 150mm i/d pipes
b) 200mm i/d pipes
Constructing of brick masonry Inspection chamber size as given below upto 0.60 meter average depth in cement sand mortar 1:5 (1 cement: 5 coarse sand ), PCC 1:5:10 in foundation, cement concrete 1:2:4 benching , 12.50 mm th. cement plaster 1:2 with a floating coat of 1 mm th. neat cement, RCC 1:2:4 slabs 100 mm th. , cement concrete topping 50 mm th. with 455 mm x 455 mm , 455mm x610 mm inside light duty CI inspection chamber cover and frame ( wieght as per ISI specification ) painted with three coats of black bitumastic paint confirming to ISI complete as per standard design .
a )in side size 450x600mm inside with 455mm x 455 mm cover and frame medium duty double seal.
b )in side size 600x900mm 455mm x455 mm cover and frame medium duty double seal.
Extra payable for every 0.30 mtr additional depth of inspection chamber complete in all respects.
a )in side size 450x600mm
b )in side size 600x900mm
SUB HEAD-11 ELECTRICAL WORK
Wiring in PVC insulated copper conductor single core FR cable, 1100volts grade to be laid in heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked installed on surface etc., complete with powder coated / anorized concealed metal boxes required for suitable number of modules, for having electronic fan regulators (two module), bell push, electronic buzzer, 3pin 6Amp., 3pin 16/20 Amp. Sockets and 6 Amp./16/20Amp. Swithces etc., and covered with Frame Plate etc., & including the cost of required number of modular switches/sockets, step type electronic fan regulator 100 watts, PVC connector (For Fan Box and Electronic Buzzer), PVC Bush, Steel Hooks, Circular Inspection Box conduit pipe & copper wire and other petty material etc. including the cost of painting as required:-
a) Wiring light point - controled by one switch, in PVC insulated copper conductor single core FR cable (ISI marked - to the approval of E-in-C) overall 1.5 sq. mm, 1100volts grade.
b) Wiring Fan point - controled by one switch, in PVC insulated copper conductor single core FR cable (ISI marked - to the approval of E-in-C) overall 1.5 sq. mm, 1100volts grade.
c) Wiring call-bell point controled by one push button switch, in PVC insulated copper conductor single core FR cable (ISI marked - to the approval of E-in-C) overall 1.5 sq. mm, 1100volts grade with bell push and electronic buzzer 230 volts AC (including the cost of bell push, electronic buzzer and plastic surface box for electronic buzzer).
d) Wiring 3 pin 6 Amp. wall socket (Shuttered) point in PVC insulated copper conductor single core FR cable (ISI marked - to the approval of E-in-C) overall 1.5 sq. mm, 1100volts grade complete with bonding to existing earth with PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1 sq. mm, 1100volts grade.
e) Wiring 3 pin 16/20 amp. power plug control (shuttered) and switch.
S/E of PVC insulated Single Core FRLS copper conductor cable ISI marked left bare in pipe or casing of suitable size excluding the cost of supply and errection of pipe or casing.
a) PVC insulated copper conductor single core FRLS cable ( ISI marked) overall 1 sqmm, 1100 Volts grade.
b) PVC insulated copper conductor single core FRLS cable ( ISI marked) overall 1.5 sqmm, 1100 Volts grade.
c) PVC insulated copper conductor single core FRLS cable ( ISI marked) overall 2.5 sqmm, 1100 Volts grade.
d) PVC insulated copper conductor single core FRLS cable ( ISI marked) overall 4 sqmm, 1100 Volts grade.
e) PVC insulated copper conductor single core FRLS cable ( ISI marked) overall 6 sqmm, 1100 Volts grade.
f) PVC insulated copper conductor single core FRLS cable ( ISI marked) overall 10 sqmm, 1100 Volts grade.
g) PVC insulated copper conductor single core FRLS cable ( ISI marked) overall 16 sqmm, 1100 Volts grade.
Wiring TV sockets and Telephone socket points in powder coated/ anodized concealed metal boxes recessed in wall required for suitable number of modules, for having TV sockets, Telephone sockets RJ11 & RJ45 (one module) etc., and covered with Frame Plate etc., & including the cost of required number of modular TV sockets, Telephone sockets RJ11 & RJ45 (one module) and other petty material etc. including the cost of cutting and filling up of chases complete as directed by the E-in-C.
a) Wiring of TV socket point (one module) including T.V. Jack .
b) Wiring Telephone socket point (one module) including Telephone Jack RJ - 11.
c) Wiring Computer socket point (one module) including Computer Jack RJ -45.
Supplying and erection and testing of following MCB/El MCB isolator etc in the existing MCB distribution board as per PWD general specifications 2010 icluding connections with suitable size of thimbles/lugs including acceseries (Breaking capacity 10 kA, Curve-C) suitable for 240/415 volts 50 cycles AC supply, testing and commissioning etc. complete in all respects as directed by the E-in-c. Make :- Havells/ Legrand/ Schneider or equivelant make.
a) MCB SP 6to 32Amp.
b) MCB DP 6to 32Amp.
c) MCB 4 P 6to 32Amp.
d) MCB DP 50,63 Amp. 10 KA
e) MCB 4P 50,63 Amp. Curve-c
f) Blanking plate
Supplying and Erection of PVC pipes & HDPE pipes (fire retardant) for wiring purposes including bends, inspection boxes etc. complete in all respects.
a) 20mm dia
b) 25mm dia
Supply and erection of G.I. Pipe- (B Class to the approval of E-in-C) for wiring/Cable purposes including bends, inspection boxes etc., where necessary including painting as per PWD General Specifications 2010 complete in all respect as directed by the E-in-C.
a) G.I.pipe 15mm dia.
b) G.I.pipe 20mm dia.
c) G.I.pipe 25mm dia.
d) G.I.pipe 32mm dia.
e) G.I.pipe 40 mm dia.
f) G.I.pipe 50 mm dia.
Supply and fixing of call bell A.C. 220 V/ 230V ( Ding-dong) , Make Anchor/Havel/ or equivalent approved by the E-in-C.
Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 15mm) including erection of the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length (including boring & refilling), complete in all respects.
Bonding to earth with G.I. wire No. 8 S.W.G. (4mm dia) in 20mm dia. heavy gauge (1.6 mm thick) welded conduit pipe including painting etc. complete in all respects.
Supply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc.
a) Sheet metal double door S.P. & N. distribution board 4 way each
b) Sheet metal double door S.P. & N. distribution board 8 way each
c) Sheet metal double door S.P. & N. distribution board 12 way each
d) Sheet metal double door T.P. & N. distribution board 4 way each
e) Sheet metal double door T.P. & N. distribution board 8 way each
f) Sheet metal double door T.P. & N. distribution board 12 way each
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .