Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.8 LAccepted-AOC 6 RAMESHWAR COMPLEX OPP OSCAR CITY SADHU VASVANI ROAD RAJKOT 360007 | RAJKOT | GUJARAT | 360007 | L1 | Accepted-AOC L1 | |
| 2 | L2₹61.9 L+₹10,900 (0.18%)Rejected-Finance NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | L2 | Rejected-Finance L2 |
Tender Value
₹69.1 L
EMD Value
₹1.4 L
Closing Date
4 Mar 2024, 2:00 pmClosed
AGM(E-E)
Asst. General Manager (Engg-Elect), Airports Authority of India, Southern Region, Operational Offices, Chennai Airport, Chennai 600 016
Facility Management contract of E and M Installations at Salem Airport for the years 2024-26
2024_AAI_185736_1
AAI/RHQ-SR/AGM(E-E)/ SLM/FMC/2024
Open Tender
Electrical Works
Item Rate
730 days
Salem Airport
Please refer Tender documents.
20 documents required · 20 mandatory
₹1,180
₹1.4 L
5 Apr 2024
12 Feb 2024
5 Mar 2024
12 Feb 2024
4 Mar 2024
12 Feb 2024
12 Feb 2024 - 14 Feb 2024
Monitoring and Maintenance of Utility Services/Internal and External Electrical Services at Salem Airport comprising of LT Panels, DG Sets, CCR Panels, Runway Lighting, High Masts, Perimeter Lighting, Indoor and Outdoor Light Fittings, Power Points, Circuit/Submain Wiring, DBs, Aviation Obstruction Lights, Lightning Arrestors, Street Light Poles/External Lights, Signages etc., (As per Annexure-3 to 5 - List of Inventories ) on duty basis by deputing sufficient number of manpower as per Annexure-1 (8 Hours of Duty of Time as decided by Engineer-In-Charge), Monitoring, Control and General Maintenance for 100% Serviceability and i/c providing consumable material like cotton waste, oil, grease & other sundry material required for cleaning etc., attending minor faults of Equipments/ Repairs/ Replacement of defective components with AAI Supplied New Components, ensuring 100% Serviceability/ satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily/ Weekly/ Monthly/ Quarterly/ Half Yearly/ Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books (as per Annexure-6 to 20) and reporting as and when required, complete Upkeeping of the Installations etc., on all days as specified and as directed by Engineer-In-Charge as required. * It shall be noted that the BOQ item no.1 shall not accept quote less than minimum wages as on date of publication of tender (Ref pg.no.193 to 194).
Maintenance of Addressable Type Fire Alarm System [FAS] (by OEM/ authorized dealer of OEM) including all Associated Accessories and Auto Dialer of all FAS Types/Models/Make installed at following Locations including programming, repairs and maintenance, attending Faults of Systems, replacement of defective components with AAI supplied new components, ensuring 100% Serviceability/Satisfactory Working Condition of FAS, Routine and General Preventive Maintenance on Monthly/Quarterly/Half yearly/Yearly Basis as per Standard Manufacturers' Practices, Break-Down Maintenance, Maintenance of Records/Service Reports and Reporting as and when required, complete Up-keeping of the Installations [FAS], as specified and as directed by Engineer-In-Charge as required measurable with effect from 01.11.2024
Terminal Building & Technical Block (Make: Edwards, Model: IO-1000)
NDB Room (Make: Edwards, Model: IO-64)
Comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. A) First Year
1.0 TR Wallmounted split AC
1.5 TR Wallmounted split AC
2 TR Wallmounted split AC
3 TR Tower type split AC
Comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. A) Second Year
1.0 TR Wallmounted split AC
1.5 TR Wallmounted split AC
2 TR Wallmounted split AC
3 TR Tower type split AC
4 TR Cassette type split AC
CMC of 50LPH, 80 ltr tank capacity, Water dispensers of Normal, Cool and Hot mode with inbuilt RO & UV at various locations including and providing all necessary consumables and spares complete as required as per special conditions.
First Year
Second Year
Decorating the Airport Terminal building with LED Decorative serial light of 250 coils each coil of minimum 40 LED lamps, running design dispaly, running serial belt of 05 coils preferably in tri colour pattern on the occasion of Independence day / Republic day each time for 3 days including prefix & suffix to the actual day of function etc.as required.
Providing decorative illumination with multicolour LED colour wash flood light of minimum 10 nos for Independence day / Republic day with required cables and all accessories to illuminate the facia of the buildings each time for 3 days including prefix & suffix to the actual day of function etc.as required as directed by the Engineer -In- Charge.
Lifting of Submersible Pumps of various capacities from the existing Bore Well/Well and reinstalling the Submersible Pumps in the existing bore well / well (After servicing/ repairing both are exclusive) complete as required.
Rewinding of following capacity submersible pumps including replacement of damaged parts such as inlet base, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required.
Less than 2 HP
Repair & Rewinding of 1400/1200 mm Sweep Ceiling fan i/c replacement of spares as required.
Repair & Rewinding of all capacities of exhaust fan i/c replacement of spares as required.
Supplying and fixing following size/ modules, PVC box along with modular base & cover plate for modular switches in recess etc as required.
3 Module
6 Module
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following sizes of medium class PVC Casing 'N' Caping along with accessories in surface as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit /PVC Casing 'N' Caping as required.
3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
Supply of 40A FP MCB 415 volts, Four pole MCB, C curve (Make: as per list of approved makes as and when required).
Supply of 63A FP MCB 415 volts, Four pole MCB, C curve (Make: as per list of approved makes as and when required).
Supply of SP MCB 5 amps to 32 amps rating, 240/415 volts, "C" curve. (Make: as per list of approved makes as and when required).
Supply of DP MCB 5 amps to 32 amps rating, 240/415 volts, "C" curve (Make: as per list of approved makes as and when required).
Supply of TP MCB 5 amps to 32 amps rating, 240/415 volts, "C" curve (Make: as per list of approved makes as and when required).
Painting of Power Supply / fire fighting installations with two coats of synthetic enamel paint of approved shade quality and brand after applying two coats of redoxide i/c scrapping and cleaning, providing putty wherever required and inscription etc., as required.
Spraying
Brushing
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ HDPE / METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq.mm and upto 185 sq.mm (clamped with 25x3mm MS flat clamp)
Above 185 sq.mm and upto 400 sq.mm (clamped with 40x3mm MS flat clamp)
Supplying and laying of 75 mm OD HDPE Pipe of PE 80 PN 6 ISI Marked along with all accessories like socket, bend etc., confirming to IS 4984 complete with fitting and cutting, jointing etc., direct in ground (75 cm below the ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., as required.
Supplying and laying of 125 mm OD HDPE Pipe of PE 80 PN 6 ISI Marked along with all accessories like socket, bend etc., confirming to IS 4984 complete with fitting and cutting, jointing etc., direct in ground (75 cm below the ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., as and when required.
Supplying and making straight through joint with heat shrinkable kit including ferrules and other joining materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 16 sq. mm
4 X 25 sq. mm
3½ X 120 sq. mm
3½ X 150 sq. mm
3½ X 240 sq. mm
LAKSHMI ELECTRICAL ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .