| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC 159 SHIV NAGAR MODIPURAM MEERUT 250 110 UP | MEERUT | UTTAR PRADESH | 250110 | ₹1.2 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.2 Cr+₹5.4 L (4.58%)Rejected-Finance | ₹1.2 Cr+₹5.4 L (4.58%) | L2 | Rejected-Finance Found in order but L2 |
| 3 | L3₹1.3 Cr+₹7.1 L (6.04%)Rejected-Finance 193 1 CIVIL LINES BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | ₹1.3 Cr+₹7.1 L (6.04%) | L3 | Rejected-Finance Found in order but L3 |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
11 Nov 2024, 6:00 pmClosed
HQ CWE Meerut
29J The Mall Road Meerut Cantt Uttar Pradesh 250001
PROVN OF MI ROOM ALONGWITH CYCLE CUM SCOOTER STAND AND GARAGE FOR AMBULANCE IN RVC CENTRE AND COLLEGE AT MEERUT CANTT
2024_MES_667610_2
94086/MRT/2024-25/E8
Open Tender
Civil Works
Lump-sum
240 days
Meerut Cantt
Please refer Tender documents
7 documents required · 7 mandatory
₹1,000
GE (P) Meerut
₹2.0 L
Yes
28 Jan 2025
1 Oct 2024
15 Nov 2024
1 Oct 2024
11 Nov 2024
23 Oct 2024
Amount
SCHEDULE A PART-I (BUILDING WORK)
Construction of BLOCK OF MI ROOM (S/S) (RCC Framed Structure) with permanent specification all as shown on drawings and as specified.
Construction of BLOCK OF AMBULANCE,CYCLE CUM SCOOTER GARRAGE (S/S) (RCC Framed Structure) with permanent specification all as shown on drawings and as specified.
SCHEDULE A PART II-A (Internal Water Supply) for details refer Sch A in pdf folder
SCHEDULE A PART II-B (Internal Water Supply)
S&F brass chromium plated wall mixer fancy type for mixing hot and cold water screwed down for iron pipe suitable for 15 mm bore pipe,complete all as specified and as directed
S&F brass chromium plated central hole wash besin mixer,fancy type with or without letterd 'HOT' or 'COLD' with long screwed shank with fly nut capstan head screwed for iron pipe suitable for 15 mm bore pipe,complete all as specified and as directed
S&F Florentine single lever basin mixer (For medical use) cast copper alloy chromium plated screwed for iron pipe and fixed to 15mm dia pipe complete in all respect all as specified & directed.
SCHEDULE A PART III-A (Internal Electrification) for details refer Sch A in pdf folder
SCHEDULE A PART III-B (Internal Electrification)
M&L for Point wiring with PVC insulated PVC unsheathed electric (FRLS-H grade) cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of chases in wall (MS/ Galvanised Iron boxes for hanging of ceiling fans and for light points along with conduit be fixed in ceiling while casting slab for fan point and for light points,in rigid pvc conduit will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including sunk in pressed steel terminal boxes suitable for paino/modular switches and sockets of thickness 1.2mm and and including Bakelite sheet cover or hylam board of 2.8mm thick including cutting holes for switches, sockets and regulators as per requirement including fixing brass screw, washer etc complete all as specified:-
(a) One light /bell buzzer/ ceiling fan/Exhaust fan point controlled by one-one way 5/6 Amp switch.
(b) One 3 pin, 05 / 06 Amps socket outlet point on same board controlled by one, one way 05 / 06 Amps switch.
(c) One 3 pin, 05 / 06 Amps socket outlet point on independent board controlled by one, one way 05 / 06 Amps switch.
All as per item No 6 above but 2.5 sqmm FRLS-H grade cable PVC for 15/16 Amp 3/5 pin socket power point including 2.5 sqmm copper conductor green as colour for earth continuity on independent board complete all as specified and directed.
S&F Vertical Loadline sheet metal enclosure double door, Triple pole and neutral (TP&N vertical loadline) AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection, with the inbuilt provison for fixing of 1 No MCCB suitable upto 125 Amp and 12 Nos MCB'S inside of DB, including 100 Amps ,16 KA 4 pole MCCB (ICS=100% ICU) with metal door and flush to wall including grouting and cutting in existing wall and making good disturbed surface to match the existing surface complete all as directed.
Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.3 of SSR part -I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completion complete all as specified and directed.
SCHEDULE A PART IV (Site Clearance and Earthwork) for details refer pdf folder
SCHEDULE A PART VA (Road, Path and Culvert) for details refer pdf folder
SCHEDULE A PART VB (Road, Path and Culvert)
Supply & fixing of (100 x100x20) mm (Cat eyes) made of non-breakable polycarbonate with electronically welded primatic Retro reflective in wet and dry condition body dust proof complete all as specified and directed. Make:- 3M / Road Star/ Green Light
SCHEDULE A PART VI A (Sewage Disposal) for details refer pdf folder
SCHEDULE A PART VI B (Sewage Disposal)
M&L construction of septic tank for 50 users, excavation in any type of soil, foundation in PCC 1:2:4, brik work in CM 1:4, RCC slab covers including RCC Precast manhole covers having 6mm plate embedded all around/fabric reinforced cover with angle iron frame, vent shaft and sludge chamber etc complete all as specified and as directed. Note : Ref TD - 217, Sheet No 1/7 to 7/7
M&L for Soakage wells comprising of excavation, in any type of soil, foundation in PCC 1:3:6 type C2 , walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4 M dia X 6 M effective depth all as specified and as directed.. Note : Ref TD - 309, Sheet No 1/4 to 4/4
SCHEDULE A PART VII (Area Drainage) for details refer pdf folder
SCHEDULE A PART VIII A (compound wall and Gate) for details refer pdf folder
SCHEDULE A PART VIII B (compound wall and Gate)
M&L for construction of steel gate 6.00 mtr wide (clear distance between pillar to distance )2.45 mtr high including brick/RCC pillar excavation and earthwork in soft/loose soil PCC in foundation PCC block steel work and painting etc complete all as specified and shown on Drgs.No-TD 120 Sheet No 1/4 to 4/4
SCHEDULE A PART IX A (External Water Supply) for details refer pdf folder
SCHEDULE A PART IX B (External Water Supply)
Material and labour for construction of valve chamber of size (950x950x900) mm (internal dimensions) built in brick masonary 230 mm thick on 150 mm thick PCC foundation (1 : 4 : 8) type D-2 using 40 mm graded stone aggregate over 100 mm thick hard cor with brick work masonary in cement mortar 1:4 using 'B' class bricks and rendering in cement mortar 1: 4, 10 mm thick internally including exposed surfaces of external surfaces, MS cover made out of 3 mm thick MS sheet on angle iron framework made out of 40 x 40 x 6 mm duly embedded in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate with hold fast made out of MS flat iron 25 x 6 mm x 300 mm long and 40 mm thick PCC coping 40 mm thick 1:2:4 type B-0 using 12.5 mm graded stone aggregate with handle hinges with locking arrangement & applying two coats of synthetic enamel paint over a coat of red oxide primer to all exposed steel surfaces complete all as specified and directed by Engineer-in-Charge.
SCHEDULE A PART X A (EXTERNAL ELECTRIC SUPPLY) for details refer pdf folder
SCHEDULE A PART X B (EXTERNAL ELECTRIC SUPPLY)
Supply ,fabrication ,installation testing and commissioning (CPRI approved) 440/400V AC LT Panel,outdoor (Kisok) type, Compartmentalized, Modular, outdoor type in 3.15 mm CRCA sheet of appropriate size,Front operatable double doors,Front & Back Openable Double doors,front & back opewnable only, Dust & vermin proof,Cable ENTRY THROUGH 3.15 MM CRCA GLAND PLATES- bottom only ,Powder coated after 7 -Tank pre treatment process Siemens Grey Shasdeb on Body/Doors & Orange shade on mounting/gland plates ,Incomer Doors 3 Phase HR sleeved colour coded Aluminium main busbar of 200 Amp - 3 Nos along with neutral half busbar and transpent FRP Covers & on SMC/DMC Support ,25X3 mm Aluminium Earth Busbar running across the lengthh of LT Panel with 2 Nos studs at both the sides -ends. Lifting arragement/Hooks at the top ,wiring with Appropriate size of copper industrial cables, Black Painted base Frame -40X40X6 mm Plates MS angle frame including danger plate of different sizes suitable for incoming and outgoing MCCBs and fitted with following specified items. INCOMING: 1 Nos Incoming MCCB 4P, 415V, 125 Amps, with SC Breaking capcity 25 KA. OUTGOING (i) 2 Nos MCCB FP, 415V, 100 Amps, with SC Breaking capcity 16 KA (ii) 2 Nos MCCB TP, 415V, 25 Amps, with SC Breaking capcity 16 KA (iii) 2 Nos MCB SPN, 230 V, 32 Amps, with rupturing capcity 10 KA
(iv) 01 No Digital voltmeter 0-500 V - 01 No ,Digital Ampere Meter 0- 200 Amp (v) RYB phase indication lamp LED type -03 No. (vi) Aluminium busbar 200 Amps with air insulated for TPN - One set. (vii) Digital timer switches 250 V single phase of 20 Amp rating with contactor fitted inside steel enclosure for street light fittings. (viii) Panel wiring with 2.5 sqmm copper cable PVC single core - 1 Job (ix) PCC plate form with foundation 1 : 2 : 4 = 1 Job (x) Timer switch with contractor three pole of 20 Amp rating with contractor fitting inside the enclosure. (xi) Panel indicator lamp for three phase RYB with LED type integrated assembly-03 Nos (xi) PCC 1:2:4 type B1 paltform plinth for installation of LT panel is inlcuded in the quoted rate. (xii) All MCCBs will be with ICS=100% ICU.
S &F 'Sintex' FRP type junction/looping box of size 300 x 200 x 105 mm having 3 nos busbar 50Amp aluminium conductor mounted on insulators one no 20x3mm aluminium bus bar with 2 clamps of aluminium strip for earthing of the armoured of the cable complete with making holes for connecting cables etc nuts bolts etc . Front openable hinged cover suitable for mounting on steel using clamps nut bolt etc pvc adopters and PVC hose pipe upto cable trench for incoming and outgoing cables, factory made duly painted with powder coating process complete all as specified and directed.
M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600x600x 6 mm earth electrode buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15 cm all round the plate using 32x6mm GI earth strip as earth lead moulded and rivetted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead protected in and including 40 mm dia GI ‘medium grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘medium grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as per electrical plate No.3 of SSR Part-II 2010 and testing on completion all as specified and directed. (Note:- Length or earth lead strip & protection pipe shall be up to 7.5 mtr)
M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire of size 4 mm dia by mean of bolts nuts, check nuts and washer of galvanised iron steel including necessary excavation, earth work, PCC chamber etc all as shown in electrical plate No.3 of SSR 2009 Part-I and connected to earthing test point all as specified including CI cover, funnel with GI watering pipe of 20mm bore medium grade & GI protection pipe 15 mm bore light grade including testing etc complete all as specified & directed. (Note:- Length or earth lead strip & protection pipe shall be up to 7.5 mtr)
M& L for Boring in any type of soil under road 1.5 mtr below the top surface of road by conventional method complete for passing throw 40mm to 100mm dia GI pipe and filling earth after laying of pipe including disposal of surplus soil complete all as specified and directed.
S&F LED postop lantern 25 watt including PVC pipe in the column of gate complete all as specified and directed.
SCHEDULE A PART XI A (Cooling Appliances) for details refer pdf folder
SCHEDULE A PART XI B (Cooling Appliances)
Supply and fix desert cooler (Steel body) electric driven (single phase), having nominal air flow capacity of minimum 6000 CuM per hour( or above ) . Complete with water circulating pump, Heavy duty exhaust Fan ,speed 1400 RPM , 400 Watt , 450 mm sweep, 90 ltrs bottom water tank capacity , Water pump capacity minimum 18 Watt , body made out of MS Sheet 1.2 mm including suitable size of ply wood work and water connection with 15mm brass stop cock , PVC connection 450mm long with PTMT nuts, PVC float valve complete all as specified and directed. Note:- The cost of stop cock, PVC connection and float valve shall be included the unit rates quoted by the contractor.
Supply and installed split AC (hot and cold type) units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity of sizes 2 TR rated complete all as specified and directed. Make:- O-General, Hitachi, Diakin. Note:- Additonal wire 2.5 Sqmm 3 core required to connect the AC with the stabilizer is inlcuded in quoted rate.
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA complete all as specified and directed. Note:- V-Guard, Microtek, Blue Bird
SCHEDULE A PART XII A (Hot water supply) for details refer pdf folder
SCHEDULE A PART XII B (Hot water supply)
Supply and fix electric water heater,storage type steel body with glass lined inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed.
JYOTI ENTERPRISES (BID ID -3162377)
Sudhir Sharma Associates (BID ID -3152491)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .