Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.0 LAccepted-AOC ASHAA BHAVAN RAMNAGAR NAKA FAIZABAD | AYODHYA | UTTAR PRADESH | 224001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹26.7 L+₹30,542.12 (1.16%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹28.3 L+₹1.9 L (7.32%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹31.5 L+₹5.2 L (19.6%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | Rejected-Technical | - | Rejected-Technical NO IN WLR |
Tender Value
₹36.9 L
EMD Value
₹74,000
Closing Date
22 Sept 2022, 6:00 pmClosed
Garrison Engineer Abohar
Garrison Engineer Abohar Pin 152116
Special repair to P-300 at 222 Fd Wksp Coy EME and Other Sanctioned Works at Mil Stn Abohar.
2022_MES_539274_2
GE ABH-23/22-23
Open Tender
Civil Works
Item Rate
180 days
Abohar Mil Stn
As per tender document
6 documents required · 6 mandatory
₹500
Garrison Engineer Abohar
₹74,000
Yes
28 Oct 2022
25 Aug 2022
4 Oct 2022
25 Aug 2022
22 Sept 2022
8 Sept 2022
Amount
SCHEDULE 'A' SECTION I (B&R Portion)
Demolition of cement concrete (un-reinforced) in floors / pavings,parapet (below or above ground level) and of any description and in any position not otherwise
Demolition of cement concrete (reinforced) in roof , floors (other than ground floor ), beams, staircase, landing,chajjas and similar suspepnded work
M & L mild steel TMT bars 10mm dia or over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as in column, beam etc complete all as specified and directed by Engineer - in - Charge.
M&L Reinforced cement concrete M-25 Nominal mix, type using 20mm graded stone aggregate in slab supported on walls,beams and columns in floors,roofs,landings,balconiies,deck slabs and in shelves and the like all as specified and directed. (form work & reinforcement measured separately) complete all as specified and directed by Engineer - in - Charge.
M&L Reinforced cement concrete M-25 Nominal mix, type using 20mm graded stone aggregate in Chajjas, Fins and the like all as specified and directed. (form work & reinforcement measured separately) complete all as specified and directed by Engineer - in - Charge.
M&L for Formwork to soffits of suspended slabs, such as roof slabs, floor slabs landing and similar work not exceeding 200mm thick (Horizontal & sloping) fair finished surfaces (Note- Steel props to be use) complete all as specified and directed by Engineer - in - Charge.
M&L for Formwork to chullah hood , chajjas, trough and similar work (Horizontal & sloping) fair finished surfaces (Note- Steel props to be use) complete all as specified and directed by Engineer - in - Charge.
M&L for Form work to edges of concrete flates treads breaks in floors, window cill concrete railing, opening in convert valley floor and roof exc 5 but n.exc 10 cm wide and sides RCC/PCC band in walls complete all as specified and directed by Engineer - in - Charge.
Demolition of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof roof complete all as specified and directed by Engineer-in-Charge.
Dismantling of Brick tiles or terracing tiles, single layer on roofs complete all as specified and directed by Engineer-in-Charge.
Material & labour for 75mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in hard standing ,plinth protection/path etc, laid in suitable panels not exceeding 3.00 m length finished even and smooth without using extra cement with 10mm Joints filled with bituminous sealing compound of grade ‘A’/bitumen mastic filler/sealant complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work built in cement mortar complete all as specified and directed by Engineer - in - Charge.
M&L for Brick work using Fly ash Modular bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
All as above item except bricks all as specified .
M & L for brick work in half brick thick wall using bricks straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) and rubbish off the permices complete all as specified and directed by Engineer - in - Charge.
Roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc. complete all as specified and directed by Engineer - in - Charge.
M & L for Virified ceramic colour (light shade) tiles 10 mm thick ( square/ rectangular ) polished,double charge, area of each tile exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick cement and sand screed (1:4) complete all as specified and directed by Engineer - in - Charge.
Ditto all as above item but as in skirting over 10 mm cement screed bed backing ( 1:3) complete all as specified and directed by Engineer - in - Charge.
M & L for Glazed ceramic light shade tiles in vertical surface 300X 450X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match in vertical surface in neat cement slurry and pointed in white cement paste pigmented to the shade over 10mm thick cement sand screed (1:4) complete all as specified and directed by Engineer - in - Charge.
M & L for non skid ceramic colour (light shade) joint free tiles with matt finish, 7 to 8 mm thick ( square/ rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in paste pigmented to tile shade over and including 15mm thick cement and sand screed (1:6) complete all as specified and directed by Engineer - in - Charge.
Ditto all as above item but as in skirting over 10 mm cement screed bed backing ( 1:3) complete all as specified and directed by Engineer - in - Charge.
M&L Granite 20mm thick(of any type) works (table rubbed and polished) in step, window cills, cooking platforms and the like in cement mortar (1:4), 20 mm thick and width not less than 600mm including pointing in white cement (1:2) using marble dust with admixture of pigments to match
Taking down chowkats or frames with shutters (with out taking off shutters from the frame) not exceeding 1.50 Sqm each and making good as per existing all as specified .
Taking down chowkhats or frames with shutters without taking off shutters from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each and making good as per existing all as specified .
Taking down shutters refixing in same opening but area exceeding 1.00 Sqm and not exceeding 2.0 Sqm making good as per existing all as specified.
Supply and fixing Fiber Glass Reinforced plastic (FRP)Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs.The frame shall be covered with fiber glass from all sides.M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions of Engineer-in-charge.
Supply and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge.
S & F pressed steel door frames size of 105X60mm thickness of sheet shall be 1.25 mm with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified and directed by Engineer - in - Charge.
S & F pressed steel door frames size of 125X60mm thickness of sheet shall be 1.25 mm with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified and directed by Engineer - in - Charge.
M&L Cement concrete 1:3:6 type C-1 for filling of pressed steel frame, post hole and hold fast blocks etc complete all as specified and directed by Engineer - in - Charge.
S & F Factory made 35mm thick IInd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; size of members of shutters as specified in SSR Part – I, Section – 8, clause 8.20 (a) ; supplied and fitted to chowkats all as specified .
S & F Factory made Plain framed, panelled shutter IInd class hardwood rail and style 35 mm thickness (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer - in - Charge.
S&F in repair powder coated aluminium sliding window three track with frame & two glass shutters using 4 mm thick glass tinted modi guard and ond shutter with stainless steel wire gauge wire cloth 0.31 mm nominal dia of wire and width of aperture 1.61 mm using aluminium powder coated section aluminium cleat, PVC track, bearing handle lock rubber beading,with two nylon roller top and bottom on each shutters etc complete fittings as approved. Note :- Size of aluminium section shall be under :- (i) Three track top and vertical - jindal main-2010 section No 20621 or equivalent as approved by GE. (ii) Three track bottom-Jindal main-2010 section No 20620 or equivalent as approved by GE. (iii) Shutter vertical section-Jindal main-2010 section 20604 or equivalent as approved by GE. (iv) Shutter top and bottom-Jindal main-2010 section 20604 or equivalent as approved by GE. (iv) Shutter top and bottom-Jindal main-2010 section 20604 or equivalent as approved by GE. (v) Shutter vertical middle (interlock) - Jindal main-2010 section 20605 20604 or equivalent as approved by GE.
S&F for powder quoted Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer - in - Charge.
S&F powder quoted aluminium window and ventilator shutter side hung type without sash, aluminium sections weighing glazing clips, rubber packing anodised aluminium snap beading screws, anodised aluminium fittings such as peg stays 150 mm long (1 no) hinges type B-21 100 mm long (2 no) tower bolts (02 Nos)suitable handle (1 no) complete all as specified and directed by Engineer - in - Charge.
S&F aluminium powered coated grill not lessthan 1.5 kg/sqm including necessary joining cleats, clips anodised aluminium snap beading screws complete all as specified as directed by Engineer-in-Charge.
S & F figured glass 4 mm thick pin head type and glazing with not exceeding 0.50 Sqm including aluminium cleat/rubber beading in each pan complete all as specified and directed by Engineer - in - Charge.
S & F Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed by Engineer - in - Charge.
S & F tower bolt 150 mm of aluminum complete all as specified and directed by Engineer - in - Charge.
S & F in repairs aluminum tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 150 mm long all as specified .
S & F door handle D type 150 mm of aluminum complete all as specified and directed by Engineer - in - Charge.
S & F in repairs aluminium handle 150 mm long all as specified .
S & F Aluminium alloy, anodised, sliding door bolt 300mm with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S & F in reapirs Aluminium alloy, anodised, sliding door bolt 300mm with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S & F mild steel 300mm ordinary rat rail rod pattern spring inluding roller and roller plate complete all as specified .
S & F in repairs mild steel 300mm ordinary rat rail rod pattern spring inluding roller and roller plate complete all as specified .
S&F in repairs hasp & staple safety type aluminium anodised hinges pins incl bolt to hinge plate fixed with screw 125mm.
S& F in repairs curtain rod of aluminium alloy of 25 mm dia with fixing brackets,stops,rollers etc. all as specified and as specified.
M&L for preperation of old wooden surface and applying two coat of synthetic enamel paint complete all as specified and directed by Engineer -in -charge.
M&L for preperation of old steel surface and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer -in -charge.
M & L providing two coats of synthetic enamel paint over new wooden surface including preparation of surface with primer all as specified .
M & L providing two coats of synthetic enamel paint over new steel surfaces and a coat of red oxide primer on including preparation of surface of any description not exceeding 10 cm width or girth complete all as specified and directed by Engineer -in -charge.
Dismantling wrought iron or mild steel work of any description all as specified .
S & F framed work such as grills, cooler stand ,grating, etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work or water tanks and similar work conforming to Fe 410-0 or Fe 310-0 all as specified .
S&F sink with drainage bord made of Stainless Steel 1mm thick kitchen with plug washer and waste including bedding in cement mortar to dwarf wall including fixing contilever brackets connecting union to pipe over all size 915x460 mm bowl of size 410 x 330 x 160 mm fixed in repair.
S&F Stainless steel plate rack of size 750mm x 600mm, made out of 1mm thick stainless steel of sheet of 1st quality complete all as specified and directed by Engineer -in -charge..
S & F repair vitreous china squatting pan Orrisa pattern size 580mm x 440mm white with integral foot rest with CI ‘P’ or ‘S’ trap and fixing in lime concrete (1 lime, 2 sand and 5 aggregate), 150mm thick all round and finished just below level of rim of pan to receive the floor finishing all as specified .
S & F in repairs PVC 10 ltrs syphonic action type flushing cistern, low level with inlet, ball valve, float and handle including brackets, flush pipe of PVC 32mm bore and connection to WC pan complete all as specified .
S & F in repairs vitrous china oval wash hand basin white of size 550X400 mm including brackets 300mm long PVC connection with brass nuts, 40mm dia waste coupling including cutting for and pinning in end of brackets or erecting stand etc coloured top bowl type screwed shank fly nut flange end including cutting for and pinning in granite slab of hole including 32 mm dia chromium plated waste coupling all as specified .(MAKE- Hindwareor equivalent in Parryware)
S&F in repair 15mm bore bib taps,chromium plated, fancy type, cast copper alloy with crutch or butterfly handle , screwed down, secrewed for iron pipe or for brass ferrule complete all as specified and directed by Engr-in- charge.
S&F in repair Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engr-in-charge.
S & F in repairs 15mm bore angle valve, cast copper alloy fancy type chromium plated with long shank and cup ( concealed type ) screwed down, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed .
S & F in repair PVC connection 15mm size with PTMT nuts of length 450mm all as specified .
S&F PVC bathroom cabinet mirror 450 x 350 mm complete all as specified and directed by Engr-in-charge.Make:-Prayag cat part no551/polytuf/shakti/pearl as approved by GE.
S & F in repair soap dish approximately size 160 x160x 90 mm and fixed with as chromium plated brass screws complete all as specified and directed by Engineer -in -charge.
S&F for in repair PVC corner shelf with bracket complete all as specified and directed by Engr-in- charge.
Taking down steel tubing 15mm bore and connections complete all as specified.
Fixing only tubes any grade 15mm bore to walls and ceiling or in floors etc including provision of new fittings as required (Serviceable galvanised tubes retrieved from respective items shall be laid under these items) all as specified .
S & F 15mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor all as specified .
Taking down steel tubing 20mm bore and connections complete all as specified.
Fixing only tubes any grade 20mm bore to walls and ceiling or in floors etc including provision of new fittings as required (Serviceable galvanised tubes retrieved from respective items shall be laid under these items) all as specified .
S & F 20mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor all as specified .
Dismantling water tanks of 500 ltrs and removing to store.
S & F rotational moulded polythene three layered white coloured water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 500 Litres all as specified and directed by Engineer - in - Charge .
M&L Ball brass valves 20mm, high pressure, with polythene float and fly nut complete, screwed for iron pipe of following description :-.
S & F in 20mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed all as specified .
Taking down CI/AC/PVC soil waste and vent pipe any radius including all fittings complete complete all as specified and directed by Engineer - in - Charge.
S&F, 110 mm PVC (SWR) pipe singal shocket (Pressure not less than 6kg/cm2) , waste and vent pipes, in any length with rubber ring joints,laid in fixed to walls with PVC stack clamps, complete all as specified and as directed by Engineer-in-Charge.
S&F, 75 mm PVC (SWR) pipe singal shocket (Pressure not less than 6kg/cm2) , waste and vent pipes, in any length with rubber ring joints,laid in fixed to walls with PVC stack clamps, complete all as specified and as directed by Engineer-in-Charge.
S&F cast iron waste and vent pipe in any length with or without ear with cement joints laid in trenches or in floor 100mm dia.
-ditto- all as above but 75mm bore
S&F for 110mm bore PVC (SWR) bends any radious provided with access door (Pressure not less than 6kg/cm2) complete all as specified and as directed by Engineer-in-Charge.
S&F for 75mm bore PVC (SWR) bends any radious provided with access door (Pressure not less than 6kg/cm2) complete all as specified and as directed by Engineer-in-Charge.
S&F for 75 mm bore PVC (SWR) multi floor trap with grating including jointing with solvent cement.
S&F for PVC (SWR) Gully trap 125/110/75 mm bore setting with including jointing with solvent cement.
S & F Grating doom Steelness steel 125 mm dia with or without waste hole of ( Min wt 40 gm )
Taking down cement plaster/dado on brick wall including racking out joints, hacking for keys scrubbing down with water all as specified .
M & L rendering 15mm thick on fair faces or other than fair faces of brick work in CM 1:6 finished even & smooth without using extra cement all as specified .
M & L Rendering 15 mm thick on fair faces of brick work or concrete surfaces, in cement mortar (1:4), in two layers of 10+5mm thick with using water proofing compound @3% by weight of cement in top layer of 5mm thick as per manufacturer's instructions, surfaces finished even and smooth without using extra cementcomplete all as specified.
M & L Washed stone grit plaster on exterior walls in two layers under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per sqm, top layer 15 mm cement plaster 1:1/2:2 (1 cement :1/2 coarse sand 2 : stone chipping 10 mm normal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to be expose the stone chippings complete all as specified (Payment for providing grooves shall be made separately).
Forming groove of uniform size 15 mm wide and 15 mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden batterns, nailed to the under layer including removal of wooden batterns, repair to the edges of panels and finishing the groove complete as per specification and direction of the Engineer-in-Charge.
Supply only liquid water proofing compound complete all as specified and as directed by the Engineer-in-Charge. Make : Dr Fixit/Fosroc/BASF/STP
M & L two coats of cement base paint over new plastered surface including preparation of surface complete all as specified and directed by Engineer - in - Charge.
M & L two coats of cement base paint over old surface including complete removal of exixting surface complete all as specified and directed by Engineer - in - Charge.
M & L Preparation of newly plastered surfaces by applying two coats of interior grade wall putty and making it smooth with sand paper by mechanical method i.e. with hand electric grinder then applying two coats of Acrylic distemper over one coat of cement primer including all as specified by mechanical method i.e. spray gun all as specified and directed by Engineer-in-charge.
M & L Preparation of Old plastered surfaces by removing old treatment and applying two coats of interior grade wall putty and making it smooth with sand paper by mechanical method i.e. with hand electric grinder then applying two coats of Acrylic distemper over one coat of cement primer including all as specified by mechanical method i.e. spray gun all as specified and directed by Engineer-in-charge.
M&L Preparing surfaces of old roof slab and cleaned of all foreign materials such as fungues, moss, dust etc, bu wire brushing dusting, sprinkling water on the surface and ensure water does not stand any where undulation on the surface repair before executing the water proofing treatment including 15 mm thick plaster in CM 1:4 as screed finished even joint of slab and wall of roof complete using water proofing @ 3% by weight of cement. If it is so, the roof surface shall be levelled then surface shall be painted with one coat of cold aplied bitumious primer @ 0.40 ltr per sqm, applied over primed surface APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm)land on primed surface by forced application complete all as specified.
M&L provide a layer of lime concrete with minimum thickness at edge 40mm and incresing unigormlu towards ridges to obrain a chain slope of (1:40) as described in para 11.27.2 of MRS SSR Prt-I complete all as specified and directed by Engineer - in - Charge.
M&L 40mm thick brick tiles laid on tiles are bedded in cement mortar (1:6) or lime mortar (1:3), 15mm thick and joints grouted flush in cement mortar (1:3) mixed with integral liquid water proofing compound as described in para 11.27.3 of MES SSR Prt-I complete all as specified and directed by Engineer - in - Charge.
Ditto itme above but except bricks tiles complete all as specified and directed by Engineer - in - Charge.
Shotcreting 25mm thick in RCC coloumn, beams and slabs etc in layers with approved design mix concrete having the specified charateristic compressive strength (with ordinary portland cement coarse sand and graded stone aggregate of 6 mm maximum size in proportion as per design criterial) in the cost of centering and shuttering at edges and corners etc as per direction of Engineer-in-Charge incl chipping of unsound/weak concrete material 50mm average thickness from slabs, beams, columns etc with manual chisel and /or by standred power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surfaces and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc incl removal of rust by applying approved rust removal chemical & coating with Dr fixit epoxy zinc primer @ 6 sqm/ltr at DFT of 100 microns as per specification disposal of debries for all lead and lifts complete all as specified and directed by Engineer-in-Charge.
S&F Hard drawn steel wire fabric not exc 4Kg/Sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia or fixing with reverts plugs or galvanised steel staples supplied and fixed complete to wood or steel members all as specified & directed by Engineer-in-Charge.
M & L 10 mm thick rendering in Cement Mortar 1:3 on fair faces of brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer - in - Charge .
M & L applying three coat of white wash on newly plastered or unplastered ceiling surfaces including preperation of surfaces, complete all as specified.
M & L Machine cut kota stone slab flooring 20 - 25 mm thick over cement screed base laid over and including 20mm thick screed bed in cement mortar 1:4 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as directed.
M & L Machine cut kota stone slab 20 - 25 mm thick in riser of steps,skirting,dado and pillar over cement screed base laid over and including 20mm thick screed bed in cement mortar 1:4 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as directed.
Cutting ,grinding,cleaning and treating the surface of existing kota stone flooring withbeeswax polishing complete as directed by Engr-in Charge.
Taking down and refixing in same opening but area exceeding 1.00 Sqm and not exceeding 2.0 Sqm all as specified.
S & F 5.50 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane.
S & F in Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples all as specified .
S & F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples all as specified .
S&F Floor door stopper of aluminum allow body and tongue, 150mm overall length, anodised, with hard drawn steel spring, fixed in floor.
M & L providing kitchen cabinet in required sizes at site made out of 18mm thick one decorative lamination sheet consisting of careass 18mm thick PVC & provision of shutters made out of 18mm thick one side decorative laminated PVC sheet all required brackets 5.5 screws etc.The panels shall be fabricated using adhesive and screws where ever required. all the edges shall be covered with 2mm thick edge bonding tape or 900 degree edge bent finish as per make and specification mentioned as drawing and specification approved by Eng-in-Charge. (a) PVC 18mm Celluca Ply (Prelam) for Shutters. (b) Ditto all above PVC Sheet 18mm Prelam for frame ,partition, shelves etc
S & F Continuous (piano) hinges 30 mm size of brass, bright finish and shape as required all as specified and directed.
S&F Magnetic catcher fixed in with nut,screw washer complete all as specified and directed by Eng-in Charge.
S & F 100mm extuded,brass handles,fabricated type polished for cabinet shutters complete all as specified and directed.
Dismantling water tanks and removing to store of exc 500 nexc 1000 ltr capacity
S & F rotational moulded polythene three layered white coloured water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 1000 Litres all as specified and directed by Engineer - in - Charge .
S&F in repair 20mm Ball brass valves, high pressure, with polytheene float and flynut complete, screwed for iron pipe orr brass ferrule and fixed.
S & F in 20mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed all as specified .
S&F sink made of Stainless Steel 1mm thick kitchen with plug washer and waste including bedding in cement mortar to dwarf wall including fixing contilever brackets connecting union to pipe over all size 495X420 mm bowl of size 410 x 330 x 160 mm fixed in repair.
S & F in repair 15 mm bore Pillar tap fancy type chromium plated with crutch or butterfly handle screwed down ,screwed for iron pipe all as specified.
S & F in repairs CP Towel rail 20 mm dia 600 mm long superior quality complete all as specified .
S&F 75mm PVC(SWR) floor trap plain with grating including jointing with solvent cement.
S & F PVC(SWR) 110 mm bore vent cowls complete all as specified and directed by Engr-in-charge.
S&f PVC(SWR) 75 mm bore junction (singleT) equal or unequal
S&f PVC(SWR) 110 mm bore junction (singleT) equal or unequal
S&F PVC ( SWR) pipes bore of 110 mm single socketed in any length with rubber ring joints laid in trenches or in floors all as specified
S&F PVC ( SWR) pipes bore of 75 mm single socketed in any length with rubber ring joints laid in trenches or in floors all as specified
M&L for preparation of Old plastered ceiling surfaces and applying two coat of White wash including preparation of surfaces complete all as specified & directed by Eng-in- Charge.
M&L for preparation of newly plastered wall surfaces and applying three coat of white wash complete all as specified & directed by Eng-in- Charge.
M&L for preparation of old plastered wall surfaces and applying one coat of white wash including preparation of surfaces complete all as specified & directed by Eng-in- Charge.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) but including connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe, sheet cover complete all as specified and directed by Engineer - in – Charge..
S&F in repair plastic water closet seat cover, white closed patern with flat bottom and cover and mild steel cromium plated or aluminium hinging device complete all as specified and directed by Engineer - in – Charge.
S&F EWC Jet spray complete all as specified and directed by Engineer - in – Charge.
S&F repairs vitreous china Half stall urinals flat back white minimum with grating and union for discharge pipe , providing & fixing plugs, bedding urinal against wall in CM 1:2 , securing urinal to plugs with & incl 60mm long brass screws, pointing around urinal back in cement , fixing automatic flushing cistern with nbrackets, flush pipe, grating and union for discharge pipe complete all as specified and directed by Engineer - in – Charge.
S&F in repair brass chromium plated central hole basin mixer with regular spout,popup waste system and 450mm long braided hoses with connection and nuts complete all as specified and directed by Engr-in-charge.Make ESS ESS cat part No.- C-211A or technocommercial euivalent jaquar/grohe.
S&F in repairs brass chromium plated wall mixer for mixing hot & cold water with provision for overhead shower with 140mm long bend pipe and wall flange screwed down for iron pipe and fixed as directed by Engr-in- charge.Make:- ESS ESS cat part No.- C-216D or technocommercial euivalent jaquar/grohe.
S&F in repairs 15mm bore angle valve fancy type chromium plated with long shank and cup cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed.Make- Jaquar CON-CHR-059KN/ Techno commercial equivalent in Kohler/Grohe
S&F in repair brass chromium plated shower Rose 125mm size with swivel joints,any size, incl shower arm fixing to pipe or union complete all as specified and directed by Engr-in-charge.
S & F towel ring of Chromium plated fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed by Engineer-in-Charge.
M & L in repair Shotcreting 25MM thick in RCC Chajjas/facia etc in layers with approved design mix (minimum cement content of 350 Kg/Cum on M-25) concrete having the specified minimum characteristic compressive strength (with ordinary protland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria),width not less than 1.0 m including the cost of certering and shuttering at edges and corners/ etc and including Fixing of hard drawn steel wire fabric(not exc 4.0 kg/sqm) as directed by Engineer-in-Charge including Chipping of unsound /weak concrete material 25 mm average thickness from Chajjas/facia with manual chisel and /or by standred power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc. including removal of rust by applying approved rust removal chemical & the coating with Dr Fixit epoxy zinc primer@ 6sqm/ltr at DFT of 100microns as per specifications and disposal of debries for all lead and lifts all complete as per direction of Engineer-in-Charge.
SCHEDULE 'A' SECTION-II (E&M PORTION)
Excavation in trenches , n exc 1.5m wide and n exc 1.5m in depth , for foundation , etc or for shaft, well, cesspits , manholes , pier hole etc n exc 1.5 m in depth and getting out comlete all as specified.
Returning , filling in including, spreading , levelling , watering and well reamming in layers not exc comlete all as specified.
Removing excavated material n exc 50m and depositing where as directed at a level n exc. 1.5 m above the starting point comlete all as specified.
Sand filling under flooors or in foundation including and consolidation as as specified and directed at site comlete all as specified.
M & L brick sub class 'B' locally available best quality laid in trenches above sand consolidted forcable protection complete all as specified and directed.
Supplying, laying, jointing and testing XLPE PVC insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 50 sqmm 3.5 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/ through pipes including provision of cable gland/aluminium lugscomplete all as specified & directed by Engineer-in- charge. Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule.
Taking down carefully copper /aluminium point wiring (light ,fan ,socket or power) complete incl fixture and fitting such as Switches, ceiling roses, pandents, regulators,sockets, light fitting etc removing materials to store for keeping in safe custody for taking credit(credit for above items shuold be made as per conditions separately) and making good distrubed surface of wall ,floors etc. complete all as specified and as directed.
M & L point wiring (Concealed) with PVC FRLS insulated unsheathed multistranded copper conductor drawn in and incl of size 1.5 Sqmm, 1100V grade in concealed PVC regid conduit, including provn of of 1.2 mm thich pressed steel sunken terminal boxes 60mm deep,suitable lenthand painted with red oxide primer for mounting switches, sockets, fan regulators covered with and including 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including 1.5Sqmm PVC insulated stranded copper conductor as earth continuity wire and connected to common earth dolly with copper lugs inserted in including MS boards complete heavy duty for housing switches, sockets, regulators, bell push etc, complete all as directed for the following.
(A) One light/Bell/fan point controlled by one way switch 5 Amp.
(B) one 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq mm size complete.
(C) one 3 pin socket outlet, 5 Amps on independent board with other switches, with cables 1.5 sq mm size complete.
(D) Ditto but with cable of 2.5 sq mm for 15 amps Socket Independent board with other switches complete all as specified.
Description all as per item No 154 here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.
M & L point wiring with PVC FRLS insulated unsheathed multistranded copper conductor of size 1.5 Sqmm, 1100V grade in Existing concealed conduit, and one run PVC FRLS insulated unsheathed copper conductor of size 1.5 Sqmm as earth continuity wire and connected to common earth dolly with copper including provn of of 1.2 mm thick pressed steel sunken terminal boxes 60mm deep suitable lenth and painted with red oxide primer in place of unserviceable shunken box complete for housing switches, , regulators, bell push etc, complete all as directed for the following.
(a) One light / fan point controlled by one way piano switch 5 Amp.
(b) One socket point 5 Amp on an independent board.
(c) One socket point 5 Amp on same board
(d) Ditto but with cable of 2.5 sq mm for 15 amps Socket Independent board with other switches complete all as specified.
S & F switch piano ,flush type single pole, one way 5 amp, all as directed.
S & F switch piano ,flush type single pole, one way 6/15 Amps 5 pin complete all as speccified aand directed.
Supply and fix in replacement of socket outlet 2 in 1, 3 pin 5 Amps complete.
Supply and fix in replacement of socket outlet 2 in 1, 3 pin 5 Amps and 15 Amps complete.
M & L for celling rose 3 pin/pvc/ polycarbonate isolated body complete all as specified and as directed.
M&L for LED tube light fitting of LED T5 tube lights (6500K) environomental freiendly energy efficient of 18/20 Watt LED including electric connection with PVC copper flexible twin core cable, 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engr-In-charge. Make:Syska SSK-SQ2001 20W or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Polycab as recommended by Engr-Incharge and approved by GE.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron of 4 sqmm SWG earht wire fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto 3m height above ground level and water pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI strip upto DBs earth connection is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto Ground level.
S&F sheet metal enclouser TPN DB having facility to fix MCCB incomer upto 125Amps and MCBs in outgoing, TPN 4 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill ptorector and blanking plates including making good disturbed surfaces complete all as specified and directed. make- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells
S & F in sheet metal enclosures for DBs double door type when MCBs to be used single pole & nuteral 8 ways s all as specified and directed by Engg-in-Charge.
S&F MCB SPN 63 Amps, 240 Volts complete all as specified.
S&F MCB SP 6 to 40 Amps, 240 Volts complete all as specified.
M&L for submain wiring comprising single core ,2 Runs of 10 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. PVC conduits and conduit fittings/existing concealed PVC conduit and conduit fittings not less than 25 mm dia complete, including provision of 2x6 sqmm nominal cross sectional area multimultistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS and specified and making good all disturbed work to match the existing complete incl taking down old UNSV sub main all as specified. ( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
Description all as per item No 30 here in before but ,2 Runs of 6 sqmm nominal cross section and including provision of 1X4.0 sqmm nominal cross sectional area for earth wire complete all as specified and directed.
Description all as per item No 30 here in before but ,2 Runs of 4 sqmm nominal cross section and including provision of 1X4.0 sqmm nominal cross sectional area for earth wire complete all as specified and directed.
M & L cutting chases, pinning in, making god to facings where reuired and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed water tubing or concealed wiring etc, and making good, cutting not exc 10 cm girth in brick walls complete all as directed by Engr-in-charge .
S & F LED street light luminaitres 20/25 watts with IP66 complete with pressure dia cast aluminium housing with GI pipe bracket made out of 25 mm dia medium grade pipe (60 cm long) bend to shape including fixing arrangement to wall with MS flat 25x3mm-2 Nos by nut, bolts and washers including electric connection with PVC copper flexible twin core cable 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engr-In-charge. Make:Syska max glow series SSK-ST25W-MG or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Polycab as recommended by Engr-Incharge and approved by GE.
Supply and fixing MCCB TPN ( 4 pole) 63 Amps 415 Volts of braking capacity 36 KA (Adjustable Thermal and Adjustable Magnetic Release Setting) complete taking down old unserviceable one and making necessary connections as existing and cleaning the terminals with CTC solutions complete all as specified and directed. Make :IndoAsian Cat No: 830330 to 830335 or equvalent of Havells/LegrandSchneider/HPL/Standard
S & F GI tube light grade galvanised of size 50 mm with all fitting and fixed to wall and celling or laid in floors for cable protection complete all as specdied and directed by Engineer-in- Charge.
Taking down/ dismantling complete exhaust fan of size 300/380/450 mm sweep.with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of Exhaust fan, taking out starter, rotor winding ball bearing, gun metal bush etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufactures design and directed and re-assembling complete exhaust fan fixing only old/new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed by Engineer-in-charge. (Note :- Ball bearing and Gun metal bush are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included in Schedule Items)
S&F for Condenser 2/2.5 MFD. (Make : Universal (metal body).
S&F for rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan 1200mm/1400mm sweep.
Supply only ball bearing number of 6201/6202/6203/6204 as required. (Make : SKF/NBC).
Supply only gun metal bush as required.
Taking down/dismantling complete exhaust fans of any size for spray painting with two coat of synthetic enamel paint of approved colour including filling cavities with filler on coat after cleaning all dust etc. including re-assembling the same and testing after writing of MES NO on completion.
S&F batton holder insulated body with back plate inluding 12 watts LED lamp complete all as specified.
M&L for LED Batten with LED tube light integrated LED channel of capacity 10 Watt white colour complete all as specified and directed by Engr-In-charge. Make: Bajaj BCLSB 10WH or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Syska/Polycab as recommended by Engr-Incharge and approved by GE.
M&L for LED light fitting 1x9W/1x10W bulk head luminaire including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
M&L for PCC preparation including cutting up to 45 cm width and depth of the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for the fixing the pipe/laying cables complete all as directed by the Engr. in Charge.
M&L for Boring hole across the Road/plinth/hardstanding/path/drain/pavement etc., suitable for inserting HDPE/GI pipe of upto 100mm dia bore pipe for 0.4 mpa working pressure for cable passing without damaging existing Raod/path/hardstanding/floor by trenchless technology or manual using necessary equipment complete all as specified and directed.
Supply and fix in replacement of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as reqd complete.
S&F sheet metal enclouser TPN DB (LOAD LINE) having facility to fix MCCB incomer upto 125Amps and MCBs in outgoing, TPN 8 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill ptorector and blanking plates including making good disturbed surfaces complete all as specified and directed. make- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells
S&F MCB SPN 40 Amps, 240 Volts complete all as specified.
S&F MCB SP 6 to 40 Amps, 240 Volts complete all as specified.
M & L cutting chases, pinning in, making god to facings where reuired and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed water tubing or concealed wiring etc, and making good, cutting not exc 10 cm girth in brick walls complete all as directed by Engr-in-charge .
S & F LED street light luminaitres 20/25 watts with IP66 complete with pressure dia cast aluminium housing with GI pipe bracket made out of 25 mm dia medium grade pipe (60 cm long) bend to shape including fixing arrangement to wall with MS flat 25x3mm-2 Nos by nut, bolts and washers including electric connection with PVC copper flexible twin core cable 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engr-In-charge. Make:Syska max glow series SSK-ST25W-MG or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Polycab as recommended by Engr-Incharge and approved by GE.
S&F batton holder insulated body with back plate inluding 12 watts LED lamp complete all as specified.
S & F GI tube light grade galvanised of size 40 mm with all fitting and fixed to wall and celling or laid in floors for cable protection complete all as specdied and directed by Engineer-in- Charge. (MAKE: JINDAL/PRAKASH/SURYA)
Supply and fixing Plug and socket type DB (Functional Unit) 20 Amps capacity with provision of single pole 20 amps MCB, plug top and earth plug, grouted flush to walls complete all as specified. Make-Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells Schneider/C&S)
S&F for PVC flexible pipes 15mm dia (heavy duty) both end socketed 450mm long for hot/cold water.
S&F for copper (CP) hot water pipe 450 mm length (heavy duty) for Geyser, connection with check nut and washer.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit of capacity 1.5 TR and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2.of capacity as upgraded versiion inverter compressor variable speed, copper condensor coil of using R-32 ref gas and 5 years warranty for compressor digital display stabilizer free operation (145 V to 290 V), anti corroision incl provn of remote control and batttery and Iron stand complete all as specified and directed. Make: Voltas /LG or Equivalent.
S & F Single pole & Neutral sheet metal enclosure with 2 pin plug top and earth plug socket complete with MCB SP & N ,20 A,240 Volts.
M&L for Sub main wiring with two single core PVC FRLS insulated stranded copper conductor cable of size 6 Sqmm and PVC insulated FR-copper wire 6 sqmm for continuous earth wire drawn into concealed conduit of size 25 mm complete all as specified and directed .
S&F as in replacement MCB distribution board double Door of sheet metal SPN 4 way with 200 amps rated bus bar 230 volts complete all as specified.
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along with poles LT cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armourd electric power cable (heavy duty) 1100 volt, earthed system, grade with aluminium conductor having cross sectional area 16 Sqmm 2 core complete all as specified. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Steel tubes 40mm bore light grade galvanised for cable protection fixed to poles/laid under floor/under road crossing complete with all fittings all asspecified .
M & L lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings incl LED bulb 12W complete, Make- Anchor/SSK/CONA
S&F Exhaust fans (Heavy duty) 300 mm sweep 230/240 volts single phase with self closing louvers GI off mode protection against birds etc and provision of cutting of walls suitabully for fixing exhaust fan and necessary plastering and making good the disturbed surface to match with existing complete all as specified. Make: Havells ventilair DB 300 mm or equvalent of Orient/Usha/
G S CONSTRUCTIONS
M/s GURFATEH BUILDERS
EAGAL CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .