| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹86,034Accepted-AOC 10 244 R K PURAM SECTOR 4 R K PURAM NEW DELHI DELHI | CENTRAL DELHI | DELHI | 110002 | ₹86,034 Quoted ₹86,033.66 | L1 | Accepted-AOC L1 |
| 2 | L2₹93,008.42+₹6,974.76 (8.11%)Rejected-Finance CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | ₹93,008.42+₹6,974.76 (8.11%) | L2 | Rejected-Finance L2 |
| 3 | L3₹1.1 L+₹23,760.69 (27.6%)Rejected-Finance PLOT NO 74 INDUSTRIAL AREA PHASE 1 CHANDIGARH | NA | NA | 160001 | ₹1.1 L+₹23,760.69 (27.6%) | L3 | Rejected-Finance L3 |
Tender Value
₹1.2 L
EMD Value
₹2,400
Closing Date
14 Aug 2026, 12:00 pmClosed
Er. Chander Shekhar
Office of the Executive Engineer, Electrical Division No. 3 Sector-4, Chandigarh.
MAINTENANCE OF E.I. IN N.R.B. AT VARIOUS SECTOR U.T., CHANDIGARH (LOCATING OF FAULT IN VARIOUS BUILDINGS AND 11 KV INDOOR SUB STATION UNDER THE JURISDICTION OF ELECTRICAL SUB DIVISION NO.7 AT U.T., CHANDIGARH (MTC. BOOTH SECTOR-38 CHANDIGARH) (FOR 12
2026_CHD_94590_1
E3/47W/107
Open Tender
Electrical Works
Percentage
365 days
Chandigarh
as per NIT
2 documents required · 2 mandatory
₹0
₹2,400
16 Sept 2026
7 Aug 2026
14 Aug 2026
7 Aug 2026
14 Aug 2026
7 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1DSR Item No.11.4 Supplying and making indoor cable end termination with heat shrinkable Jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminum conductor cable of 11 KV grade as required | |||||
| 1.01 | 3 ½ x 70 sq. mm | 2 | Each | 3,623 | ₹7,246 |
| 2 | Repair and servicing of HT-OCB's / VCB's of 400 Amps. To 800 Amp. 350 MVA of various types of make. The job includes the dismantling of OCB's/ VCB's & reinstallation of the same in the control panel unit. The cost also includes cleaning the 11KV contacts of HT OCB/VCB, Lubrication of movable parts of mechanism of the panel units, replacements of minor pars during the servicing job being done at site. The job also includes servicing & the cost of minor parts & other, petty material required to complete the job i.e. VCB shunt trip coil, mechanism greasing etc. The job includes the guarantee. | 5 | Each | 5,000 | ₹25,000 |
| 3 | Repair and servicing of LT ACB's of various rating from 630 amp to 1600 amp. of various make. The job includes the dismantling of ACB's and reinstalling of the same in the control panel after the servicing and repairing etc. The cost also includes cleaning of LT contacts mechanism of the panel units, replacement of minor parts during the servicing job being done at site. The job also includes servicing and the cost of minor parts and other petty material required to complete the job i.e. ACB trip coil, mechanism greasing etc. The job includes the guarantee, free servicing and mtc for one year including the repair of the same and replacement of minor parts setting of protection relays, NO/NC contacts, strip coil etc, free of cost during service tenure of 1 year. | 5 | Each | 3,000 | ₹15,000 |
| 4 | Locating of HT/LT underground cable fault approx. 1 mtr. Below ground level with the help of cable fault locating machine. The job includes the cost of digging the excavation/removing the bricks from trench after locating the fault in cable and refilling the trench in original finish after removing the fault and other petty material etc. as required to complete the job. | 5 | Each | 6,000 | ₹30,000 |
| 5 | Supply and Refilling of transformer oil in the existing transformer. The job includes the cost of all petty material require to complete the job to entire satisfaction of Engineer-in –change. | 150 | P.Ltr. | 150 | ₹22,500 |
| 6 | Servicing of 500 KVA Oil Type and 1000 KVA dry type indoor transformer after dismantling all the HT /LT connections to check the insulation resistance to locate the fault with help of magger. The job includes the cost of stepping up / down as per the requirement. The job includes cost of all petty material charges required to complete the job at site to the entire satisfaction to the Engineer-in-Charge. | 3 | Each | 3,500 | ₹10,500 |
| 7 | Checking the faulty CT/PT metering unit after opening the incomer / outgoing 11 KV cables. The job includes the cost of all petty material require to complete the job to entire satisfaction of Engineer-in –change. | 2 | Each | 3,000 | ₹6,000 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 23.51 MB
BOQ_116055.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .