| 1 | L1₹1.4 CrAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹1.4 Cr | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹1.5 Cr+₹8.1 L (5.74%)Rejected-Finance | ₹1.5 Cr+₹8.1 L (5.74%) | L2 | Rejected-Finance BEING NOT LOWEST TENDER |
| 3 | L3₹1.5 Cr+₹8.2 L (5.78%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | ₹1.5 Cr+₹8.2 L (5.78%) | L3 | Rejected-Finance BEING NOT LOWEST TENDER |
| 4 | L4₹1.5 Cr+₹9.5 L (6.69%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | ₹1.5 Cr+₹9.5 L (6.69%) | L4 | Rejected-Finance BEING NOT LOWEST TENDER |
| 5 | L5₹1.5 Cr+₹10.3 L (7.31%)Rejected-Finance PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | ₹1.5 Cr+₹10.3 L (7.31%) | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹2.3 L
Closing Date
5 Jun 2021, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
PROVN OF CERTAIN SANCTIONED INCLUDING REVENUE WORKS AT AFS SULUR
2021_MES_441786_1
8394/E8
Open Tender
Miscellaneous Works
Item Rate
240 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Yes
GE AF SULUR
₹2.3 L
Yes
18 Jun 2021
10 May 2021
7 Jun 2021
10 May 2021
5 Jun 2021
31 May 2021
10 May 2021 - 29 May 2021
Amount
SCHEDULE A BOQ
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, cesspits, manholes, pier holes, etc. and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soil complete all as specified and as directed.
Removing excavated material to a distance exc. 1.50km but n exc. 5km and depositing where directed complete all as specified and as directed.
M&L Plain Cement Concrete 1:2:4 type B2 (40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
M&L Formwork to faces of walls, abutments, parapets and staircases railings and similar work including attached pillasters, battresses etc vertical or to batter rough finished, flat surfaces of concrete complete all as specified and as directed.
M&L RCC Design Mix M-30 (using 20 mm graded stone aggregates) as in walls, retaining walls, basement walls, ballast walls and the like, any thickness, above top of footings, including attached pillasters and buttresses complete all as specified and as directed.
S&F High strength corrosion resistant TMTsteel bars of Grade Fe–500 of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified.
M&L cement concrete type B2 1:2:4 (40 mm graded stone aggregate for surface channel and drains complete all as specified and as directed.
M&L Brickwork with fly ash bricks using modular bricks, straight or curved on plan exc 6m mean radius built in cm 1:4, complete all as specified and as directed
M&L Plain Cement Concrete 1 : 2: 4, Type B1 (using 20 mm graded stone aggregate) for coping including necessary form work complete all as specified and as directed.
M&L Rendering 15 mm thick in two layers on brick or stone or concrete surfaces,with first coat 10mm thick in cement mortar 1:4 and 2nd coat 5mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid seperately.
M&L reinforced precast cement concrete 1:2:4, Type B–1 using 20mm graded stone aggregate as in landings, cover slabs [for manholes etc], chullah hoods, Chajjas, water troughs, mangers, Shelves and similar articles with plain faces including formwork, set in cement mortar 1:4 complete all as specified and as directed.
M&L Hardcore with broken stone or boulders of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L Plain Cement Concrete work in pavement/hard-standing of flexural strength 40 kg/square centimetre, in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less complete all as specified and as directed.
Dismantling/taking down old existing damaged cement plaster, loose/ unsound weaken cement concrete of any description and in any position from external / internal surface of RCC roof/ slab/ beams/ columns/ RCC facias for an average depth of 25mm (Approx height 7.5m from natural ground level) with power driven pneumatic flat/pointed chisel and removing the honeycombed area including all the corners and making a neat profile of the cavities, roughen the smooth surface, scrapping out/removing corrosion all loose/scale/rust etc from the visible reinforcement by applying. Geopolymer based Geo Krete-VR of Make eco materials or equivalent in FOSROC chemicals/ Tiki Tar/ M/s STP limited (as approved by GE) over the existing damaged surface including mixing mortar with recommended water cement ratio and levelled the surface to match with existing surface all as per manufacturer's instructions as specified and directed. Note:-The geo polymer based water impermeable ceiling and vertical surface repair mortar shall have compressive strength of 10 Mpa in 3 hours and 35 Mpa in 28 days without any water curing and curing compounds having a water penetration of less than 3mm when tested as per DIN 1048 and RCPT value of less than 900 coloumbs when tested as per ASTM C 1202.
Note for item No 17 :- The tenderer shall take into consideration the following points while quote rate for the above item :-
(a) Taking down cement plaster on brick or stone walls, or concrete or ceilings etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises, removal and depositing unserviceable materials outside MD land and leaving the work clear of any plastering or Racking out joint/pointing to stone masonry, coursed or uncoursed in wall complete all as specified and directed. The unit rate is deemed to be included this provision also.
(b) Surface preparation such as creating mechanical key like roughning the surface by scrubbing, grit blasting and cleaning the existing surface using high pressure water jet machine having pressure up-to 500 to remove the dirt, dust, loose particles, wax, efforencence and other contaminations from the surface of RCC columns/beams/slabs/ facia/any brick/stone surfaces etc all as manufactures and all as specified and directed by Engineer-in-Charge. The unit rate is deemed to be included.
(c) Providing, fixing and erecting scaffolding in double face structure, as required along with approach system for the repairs / plastering of the buildings to facilitate execution of all items of works,complete with necessary support, propping system etc for external repair. The unit rate is deemed to be included this provision also.
(d) Material shall be procured from the authorised manufacturer only.
(e) The work shall be carried out through authorised and qualified applicators of the manufacturer only.
M&L PCC 1:2:4 ,Type B-1, using 20mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
S&F Vitreous china wash down water closet pan (pedestal pattern), white (exluding fixing bolts, flushing cistren and flushpipe) and including seat cover for pedestal pattern fixed complete all as specified and directed
M&L Joint free Non Skid Ceramic Tiles 7 to 8 mm thick [Square or Rectangular] Coloured, area of each tile exceeding 0.06 Sq.m and not exceeding 0.18 Sq.m, as in Floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer,15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note : The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
S&F Stainless steel sink,1.00mm thick for kitchen or laboratory with plug washers waste pipe including fixing cantilever brackets connection union to pipe etc, overall size 495mmx420mm with bowl size 410mmx 330mmx160mm excluding waste coupling waste pipe complete all as specified and directed. Make:-NIRALI / BLUE STAR /TATA
S&F Waste coupling of CP 40 mm dia with discharge pipe (half or full threaded) suitable for sink complete all as specified and as directed.
S&F Low density polyethylene pipes (LDPE) 40mm bore of pressure rating 6Kg/sqcm laid in trenches or fixed with walls complete all as specified and as directed.
S&F in CP sink cock with swinging casted round shape spout screwed down screwed for iron pipe 15mm bore complete all as specified and as directed. (Make : CAT part No CQT-23347 of Jaquar or equivalent make of hindware/parryware)
M&L 25 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20°C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, complete to walls, ceilings or in floors etc. all as specified and directed. Make : SFMC, Prince, KPT
Note for item No 31 :- (a) The unit rate shall include connecting to existing GI pipe and with all fittings as directed.
(b) The unit rate shall include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
(c ) Wall thickness of pipes shall be all as per IS : 15801
M&L PVC (SWR) floor trap 75mm dia of outlet pipe, plain with grating including jointing with solvent cement complete all as specified and as directed.
M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed.
M&L PVC (SWR) pipes single socketed in any length with rubber ring joints of 75 mm bore fixed to wall complete all as specified and as directed.
M&L PVC (SWR) bends 75mm bore complete all as specified and as directed.
M&L PVC (SWR) 75mm junction (single T) equal or unequal provided with access door complete all as specified and as directed.
M&L for Glazed ceramic coloured tiles 450 x 300 mm x 7/8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles on vertical surface such as dado including 10mm thick in CM (1:3) backing coat complete all as specified and as directed. Note : The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
Demolition of brick work masonry, built in cement mortar including all quoins, pillars etc., complete all as specified and directed.
M&L PCC in foundation filling and mass concrete type D-2, 1:4:8, using 40mm graded stone aggregate complete all as specified and directed.
M&L Rendering 15 mm thick in two layers on brick or stone or concrete surfaces,first coat 10mm thick in cement mortar 1:6 and 2nd coat 5mm thick in cement mortar 1:6 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed. Note: (a) Water proofing compound shall be measured and paid seperately.
M&L Preparation of old plastered or un plastered old surfaces of walls, Chajja, balcony, facia etc. by brooming down or steel wire brushing scrapping down, smoke shoots moulds, mass efforescent salt, treating oil and greasy spots ect and applying one coats of oil bound distemper all as specified and directed
M&L 100 mm thick Plain cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate ) as in sub base , filling and mass concrete for receiving tiles/ surface channels and drains etc complete all as specified and directed.
M&L Chequered cement concrete tiles 30cmx30cmx25mm thick machine pressed set jointed and pointed in neat cement slurry as in floors and cut and polished using grey cement and pigments over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) complete all as specified and directed. Note : The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation/fixing.
Complete removal of existing water proofing treatment and expose of top surface of RCC slab of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with water and using wire brush including removing debris to out side the MoD land and providing following :- (a) Dismantling existing cement concrete/roof tiles on roof including removing debris to out side MD land as directed. (b) Bring upto the slope by providing filling of light weight materials such as cinder, light weight concrete etc as required, and then providing PCC 1:2:4 type B1 of average thickness of 50mm. (c) Rendering 10mm thick in CM 1:3 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 3% by weight of cement. (d) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried. (e) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (f) Providing APP modified water proofing as approved by GE weighing not less than 4kg per sqm unrolled over the bituminous coated surface with 100mm over laps, the overlap shall be sealed by flame as per manufacture instructions complete. (g) Over the APP membrane, apply evenly a tack coat of hot air blown bitumen of grade 85/25 at the rate of 1.20 kg per sqm including cleaning of surface. (h) Applying a coat of aluminium paint at the rate of 100 gm per sqm as per manufacture instruuction over bituminous layer complete all as directed. Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface.
M&L Rendering 10 mm thick on brick or stone or concrete surfaces, in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L Rotational moulded polythene water storage tank of 1000 Ltrs capacity (three layer white colour) cylinderical vertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I complete all as specified and directed.
M&L Providing and fixing Gypsum Board 12mm thick in ceiling fixed on Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx. 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section,not exc 1.2 m c/c of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. The Gypsum board ceiling shall be treated with two coats of Oil bound distemper over one coat of 3mm thick putty complete all as specified and directed.
Taking down Chowkats or frames with shutters (Without taking off shutters from the frames) exceeding 1.5 Sqm each but n exc 4 sqm each complete all as specified and directed.
M&L Factory made UPVC three track sliding Window frame having 2 tracks for glass shutter and 1 track for mosquito sash made of upvc profile section of size 73mm x 42mm (wxh) having outer wall thickness of 2.0mm(+/-0.2mm). Sliding glass shutter shall be made of UPVC section of size 55mm x 33mm and sliding wire mesh shutter shall be made of UPVC section of size 40mm x 22mm. All section of the frame, sash, transom & mullion, as applicable, shall be duly reinforced with G/J/U/O shape galvanised mild steel section of required thickness considering structural / wind load requirement. System shall be provided with the suitable upvc bead for glazing of the system & fitted with inner & outer EPDM seal gaskets. Clear Glass of Saint Gobain / Modiguard make with thickness of 4mm and stainless steel wire cloth of 0.19mm nominal dia. All welded joints are to be neatly trimmed & feature grooved/raised nib finish so as to make the finished product free from all sharp edges & burrs. All the corner / mullion / transom joints of the frame and sash shall be mitered cut & fusion welded without any mechanical joining. System shall have adequate drainage mechanism to permit the escape of water from horizontal member beneath each sealed unit. System is to be provided with proper operating & locking hardware mechanism. Window locking system will be either both side push lock system or semi-circle locking system in centre. Complete window shall be fixed in to the existing pre finished aperture, by drilling and fixing through the outer frame using quality fasteners & silicon glue is applied to fill up the crevice between wall and window frame for leak proof installation complete all as specified. Note: - The contractor will have to submit 5 years warranty certificate for upvc profile and 1 year warranty certificate for hardwares.
S&F Framed work such as grills , grating ,etc with ends of bars shouldered and or reveted for forged in to spike, framed guard bars barred iron doors, ladders, balusters, walk ways raling framed work for water tanks similar work confirming to Fe -290 Gde E-165
M&L Granite work (of any type) 18 to 20mm thick (table rubbed and polished including round edge) in steps, jambs, pillars, windowcills, cooking platforms, wash basin platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with granite shade over and including 15mm thick screed bed in CM1:4 complete all as specified and directed.
M&L Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat etc complete all as specified and directed. Note: Minimum thickness of powder coating shall be 50 micron.
S&F 9mm thick prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination fixed with screws to aluminium frame complete all as specified and as directed.
S&F Sheet glass, ordinary quality and glazing, 4 mm thick with oil putty in squares exceeding 0.5 Sq. M in each pane glazed with putty or fixed with beads complete all as specified and directed.
S&F Mortice lock brass 4 levers vertical type size 100mm fixed with two keys complete all as specified and as directed
S&F Door closer hydraulically regulated designation No. 3, universal type, Aluminium body (extruded section), suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
S&F Floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor 150mm complete all as specified and as directed.
M&L 25mm thick PCC (1:2:4) type-B-1 using 20 mm graded stone aggregate as in floors complete all as specified and as directed.
M&L Vitrified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer,15 mm thick in Cement Mortar 1:6, complete all as specified and as directed.
Note for item No 62 :- (a) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (b) The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
S&F 12mm thick toughened glass for doors including polished by machine on edges including stainless steel clips/hinges, stainless handles (02 Nos), floor spring double action complete all as specified and as directed by Engr-in-Charge (Make : Saint Gobin/ESG/Modi)
S&F Wash basin vitrous china (flat back and angle back Type) size 580x400mm including taps waste chain and plug and porceline stopper brackets including cutting for and pinning in ends of brackets or erecting stand with waste pipe, fixed complete as directed.
S&F Pillar taps 15mm bore CP with capstan head screwed down high pressure screwed for iron pipe Cat Part No CQT -23021KN of Jaquar or equivalent to /Parryware/Hindware/Cera, complete as directed.
S&F 32mm dia Waste fittings,brass,chromium plated for basins with long screwed shanks and fly nuts,flange end bedded in red lead cement and other end fixed complete all as specified and as directed.
M&L 20 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20°C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, complete to walls, ceilings or in floors etc. all as specified and directed. Make : SFMC, Prince, KPT
Note for item No 68 :- (a) The unit rate shall include connecting to existing GI pipe and with all fittings as directed.
(b) The unit rate shall be include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
(c ) Wall thickness of pipes shall be all as per IS : 15801
M&L 20mm outer dia of pipe PP-R Gate valves (brass insert) as per requirement of the site Complete all as specified and as directed
S&F Angular stop cock, valves high pressure screwed both ends iron pipe or for unions 15mm bore, CAT Part No G3007A1 of Parryware or equivalent to Hindware/Cera complete as directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints of 110 mm bore fixed to wall, complete all as specified and as directed.
S&F PVC (SWR) bend 110mm bore equal or unequal provided with access door
S&F PVC Dual flush ceramic colour , low level, 10 litres capacity, star white with inlet float ball valve, PVC flush pipe and handle, making proper fixing and hanging arrangements Cat Part No 21029 of - hindware or equivalent complete all as specified and as directed.
S&F stainless steel letters 12 inches height made out of 1mm thick stainless steel plate, cut folded, welded to required shape including fixing on the granite with bolt nuts/ steel surface etc all as directed by Engineer-in-Charge
S&F False ceiling using GI snap grid size 60x60cm with main runner 38x24,wall angle & cross tee 29x24mm wall angle 24x24mm suspended with 4mm dia GI Wire fixed with steel dash fasteners carrying max load upto 8.1 Kg/Sqcm with and including 4mm thick designer ceiling board (Lake & Hill) manufactured by M/s Everest regular T-2430 or equivalent in Ramco/ Charminar/ Armstrong complete all as specified and as directed.
M&L Vitrified Ceramic tiles 10 mm thick, dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer,15 mm thick in Cement Mortar 1:6, complete all as specified and as directed.
Note for item No 79 :- (a) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (b) The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
M&L Vitrified Ceramic tiles 10 mm thick, dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in skirting/dado. etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,10 mm thick in Cement Mortar 1:3 including taking down existing tile and rubbish off the premises complete all as specified and as directed.
Note for item No 81 :- (a) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (b) The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
M&L Collapsible steel gates, top hung consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with hold fasts and brackets, complete all as directed.
M&L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 gradeSt.-240) complete all as specified and as directed.
S&F Pre painted Coloured Galvalume roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws complete all as directed.
M&L Clean Sawn Second class soft-wood in scantlings complete all as specified and as directed.
S&F 12mm thick toughened glass frameless partition, with a provision of doors ( swing and sliding type) with all necessary to patch fittings and bottom insert like corner connection and side connector and bottom insert to the floor about 15 to 30mm or with aluminium profile 12mm depth complete all as specified and as directed. (Make : Saint Gobin/ESG/Modi)
Preparation of old plastered surface of wall including removing existing treatment completely and applying two coats of wall care putty to achieve smooth surface of wall with two coats of oil bound distemper by roller application complete all as specified and directed. Note : (i) Cost of scaffolding required deemed to be included in the quoted rate of item and nothing extra shall be admissible on this account. (ii) Work will be carried out through authorised applicator/agency of approved manufacturer.
M&L Powder coated aluminium door shutters,aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each doors, hinges anodised aluminium snap beading screws etc complete all as specified and directed. Note:-Glazing and particle board work shall be measured and paid seperately.
Supply and fixing 100mm long Butt hinges medium weight cold rolled stainless steel, fixed to wooden frame/welded to metal frame
Supply and fixing 75mm long Butt hinges medium weight cold rolled stainless steel, fixed to wooden frame/welded to metal frame
Taking down cement plaster on brick or stone walls, or concrete etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plastering and material and labour for Rendering 15 mm thick in two layers on brick or stone or concrete surfaces,first coat 10mm thick in cement mortar 1:6 and 2nd coat 5mm thick in cement mortar 1:6 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed. Note :- (a) Water proofing compound shall be measured and paid separately. (b) The unit rate quoted is deemed to included for Removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protection to outside MD land. (c) Periodicity of cutting of grass shall be before commencement of work and after completion of repairs.
Supply only water proofing compound complete all as specified and as directed. Make :- Dr Fixit Pidi Proof or equivalent.
Preparation of plastered or un plastered new surfaces of walls, Chajja, balcony, facia etc. by brooming down or steel wire brushing scrapping down, smoke shoots moulds, mass efforescent salt, treating oil and greasy spots ect and applying two coats of oil bound distemper over a coat of primer all as specified and directed
Demolition of cement concrete (reinforced) in of any description and in any position and removal of debris out of MD land complete all as specified and directed.
M&L Brickwork with fly ash, bricks using modular bricks, straight or curved on plan exc 6m mean radius built in cm 1:6, complete all as specified and as directed
M&L RCC 1:1½:3 Type B-1 using 20mm graded stone agg. as in Slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and directed
M&L Preparation of newly plastered surfaces and applying two coats of exterior emulsion over a coat of primer on walls complete all as specified and as directed.
M&L Point wiring complete with 4 sqmm copper multi stranded unsheathed 1100 volts grade FRLS cable drawn through and incl PVC Casing capping with accessories in wall/roof/ceiling/hangar steel frames etc incl MS Modular terminal boxes, concealed/fixed surface to walls covered with modular plates with cover etc and 4 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor controlled by one 15A switch socket independently & connecting to common earth dolly including removal of existing unserviceable point wiring complete all as specified and as directed. Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, cover plate etc will be measured and paid for separetely. (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
(a) One light point/fan/bell point controlled by one switch
(b) All as per item No. 99 here in before but for One 3 pin socket out 5 amp on the same board
(c) All as per item No. 99 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 99 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
S&F Modular switch 1 way 6 Amps, 1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) including removal of existing complete all as specified and as directed.
S&F modular switch 1 way 16 Amps, 1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) including removal of existing complete all as specified and as directed.
S&F modular socket outlet multipurpose 2/3 pin 6 amps, 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) including removal of existing complete all as specified and as directed.
S&F Modular socket outlet multipurpose 2/3 pin 6/16 amps, 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) including removal of existing complete all as specified and as directed.
S&F white cover plate with frame, 3 Module including removal of existing complete all as specified and as directed.
S&F white cover plate with frame, 6 Module including removal of existing complete all as specified and as directed.
S&F white cover plate with frame, 8 Module including removal of existing complete all as specified and as directed.
S&F metal flush box 3 module including removal of existing complete all as specified and as directed.
S&F metal flush box 6 module including removal of existing complete all as specified and as directed.
S&F metal flush box 8 module including removal of existing complete all as specified and as directed.
S&F electronic modular fan regulator 230 volts, step type socket type, hum free 100/ 240 watt 2 Module including removal of existing complete all as specified and as directed. Make :- Havells/ Crabtree/ Indo Asian
S&F ceiling rose, surface type Bakelite 65x55mm 3 terminal complete all as specified and as directed.
S&F MCB SPN 40 Amp , 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Legrand Cat Part No 408618 or equivalent of Schnieder, L&T.
S&F Metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls. Make : Cat Pt No 607841 of Legrand or equivalent of Schnieder (Multi -9)/ L&T (Hegar) complete all as specified and as directed.
M&L Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with one run 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed.
Note for item No 118 :- (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor and PVC casing capping shall be measured as one length (b) Connections of cables with MCBs or bus bars shall be done through appropriate size of brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Supply and fixing Arcus flood light 12 W for focusing name board of Dornier hanger, Aluminium die cast housing with high purity lens offers facade lighting with superior performance and glare free light distribution enhancing accent lighting complete all as specified and as directed. Make/Model : Cat No LF-181-030-30-XX of Wipro or equivalent in Philips/ Bajaj.
S&F Triple pole MCB 63 Amp , 415 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and as directed. (Make/Model : Legrand Cat Part No 408661 or equivalent. of Schnieder (Multi -9)/ L&T (Hegar).
Supply and fixing energy efficeint Ceiling fan 1200mm sweep, energy efficient ISI mark with 5 star rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt and flexible 3 core of size 1.5 sqmm not less than 0.5 m long complete, writing MES No 2 cm height with synthetic enamel paint all as specified and as directed. Make : Havells cat Part No. ES Neo or equivalent in Bajaj/ Orient. Note:- The contractor shall give a written guarantee of minimum two years from completion of work.
S&F Inverter AC split unit Indoor/ outdoor complete with smart inverter full HD filter, bio sleep smart server, turbo cooling, twin BLDC compressor, wide air flow blade, antibacterial coating, dehumidification, auto clean quiet mode, auto restart 24 hours timer, auto cooling fan mode, 4 step fan speed, of capacity 1.5 TR, operating on 230 Volt single phase AC supply, with cordless remote control unit and Filter Configuration with, Catechin, Silver Ion, Anti Bacterial/ Anti Acarine/ Active Carbon/ Vitamin C/ Dust Filter complete including installation all as specified and directed. Make: Sumsung cat part No AR18MV5NEWK or eqvt Cat Part No KS-Q18ENZA in LG or HITACHI
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 285 V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and of capaciy 4 KVA complete all as specified and as directed. Make - V-Guard Model No VG 500 or equivalent in Microtek/ AE
S&F factory made powder coated distribution board SP & N 8 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens/ Schnieder/ Legrand
Supply and fixing single pole MCB 40 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified (Make/Model : Legrand Cat No : 408596 or equivalent. of Schnieder, Siemens.
Supply and lay XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 2 core laid in trenches/ ducts/ fixed to wall/ pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc all as specified and as directed. Make :- Havells/ KEI/ Polycab.
Supply and fixing single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified. Make/Model : Legrand Cat No : 408587 to 408595 or equivalent. of Schnieder, Siemens.
S&F 36 W LED recessed 2x2 luminaire with classic design & glare free soft illumination. Housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. CRI >80, Color temperature5700±300K, THD <10% and PF >0.95, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO +45 DEG.C; Input Supply Voltage Range:150-277 V, Frequency :50-60 HZ. Driver Safety requirement stds: IS 15885-2-13, Test Report to be submitted. Make : Bajaj Cat Part No Skylux - BZRSQL 30W GZi WH / Philips cat No RC 355 BLED 33-6500 PSU OD WH or equivalent in Wipro.
Note for item No 129 : (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
Supply & fix wall mounted fan complete with and accessories 230 V,400 mm sweep. BEE 5 star rated including fixing arrangement on wall/ angle all as specified and as directed . Make : Havells Model No Sameera wall Fan or equivalent in Bajaj/ CG.
S&F Exhaust fan 250 mm sweep 230 volt square type with louvers of PVC body including necessary cutting, making holes on stone/brick walls, fixing arrangement with wooden frame of 20 mm thickness including necessary nut, bolts / screws all specified and directed. Make-Havells Cat No Ventil DX-White or equivalent in bajaj, Crompton Greaves
Supply and fix linear general purpose luminaries 5 W Mirror light fitting. Make/Model : Cat No BCLSB 05 NW of Bajaj or equivalent in Havells/ CG.
M&L Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with one run 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed.
Note for item No 134 :- (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor and PVC casing capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Supply and fixing in replacement factory made powder coated distribution board VTPN 4 way (VTPN MCCB DB), IP 54 along with 200 Amp 25 KA 4 pole MCCB double door including bus bar, Neutral bar, standard DIN rail, earth bar acomplete all as specified and directed. Make/Model of VTPN DB : Cat No 507761 of Legrand or equivalent in L&T or Schnieder. Make of MCCB :- Legrand, L&T, Schneider
S&F MCB SPN 32 Amp , 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Legrand Cat Part No 408617 or equivalent. of Schniede, Siemens.
Supply and fix ALFA series track mounted LED spot light luminiare suitable for single phase track 12 W light fitting. Make/Model : Cat No ALP-A 12 W NW 12 W LEDCOB of Bajaj or equivalent in Philips/ Wipro.
S&F in replacement factory made powder coated distribution board SP & N 4 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens/ Schnieder/ Legrand
S&F Inverter AC split unit Indoor/ outdoor complete with hybridjet inverter full HD filter, bio sleep smart server, turbo cooling, twin BLDC compressor, wide air flow blade, antibacterial coating, dehumidification, auto clean quiet mode, Flexicool technology, auto restart 24 hours timer, auto cooling fan mode, 4 step fan speed, of capacity 2 TR, operating on 230 Volt single phase AC supply, with cordless remote control unit and Filter Configuration with, Catechin, Silver Ion, Anti Bacterial/ Anti Acarine/ Active Carbon/ Vitamin C/ Dust Filter complete including installation all as specified and directed. Make: Carrier Model No Durafresh NXI 24K or equivalent in Samsung/ LG/ Hitachi.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and as directed. Make :- V Guard, Microtek, AE.
S&F surface mounted 20W LED of size 1 x 1 feet sleek surface down lighter, enviorment friendly, new generation, energy saving with option of 700 to 2000 lumen, power factor >.95, inbuit short circuit protection and surge protection including accessories complete all as specified and as directed. Make/Model : Cat No SM251C LED20S- 6500 PSU WH of Philips or equivalent Wipro/Bajaj Note : (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
M&L Shifting and relocating of existing flood light/ garden lights incl neccesary PCC foundation and upto 5 mtr 2.5 sq mm 3 core round PVC cable with PVC conduit and neccesary excavation and earth work as specified directed by Engr in charge.
M&L PVC casing capping/ trunking of size 100 x 50mm complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor including and drawn through and incl PVC Conduit with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Cable : Plaza/ Polycab/ Havells Make of Conduit :Prince/ Modi/ Presto Plast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lups) only.
(a) One light point/fan/bell point controlled by one switch
(b) All as per item No. 145 here in before but for One 3 pin socket out 5 amp on the same board
(c) All as per item No. 145 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 145 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Supply, installation, testing and commissioning of geared motor and deep groove ball bearing integrated high volume low speed fan (Hanger fan) of sweep dia 24 feet having 05 No of blades made of high-grade aluminium alloy 6061 T6 material, anodised silver finish, 9° dihedral angle-blades swept up by 9° from the horizontal to maximize the area covered by the airflow with the same power consumption, DIN 17100 impeller grade, helical two stage inline gearbox, Danfoss FC 51 drive type, Hub integrated to the drive indirectly with a deep groove ball bearing for a safe and secure assembly, 1.5 KW (2HP), 50Hz, 415V three phase induction motor, reversible type, integrated VFD controlled of RPM 0 to 52, analog input speed setting through 0 to 10 volts, Airflow 6,0,3000 CFM, coverage area around 29700 sqft, noise level @ 3 meter below fan <65 dB, digital/ analog control, touch screen HMI, shall be connected to building management system, LCP control, Real time data monitoring system, through mobile app functioning of maximum 5 HVLS fan shall be able to control. It should be communicated through modbus RTU 485, real time turn ON/ OFF as per requirement, as a safety measure shall have 2 stage structure failure protection for impeller and hub assembly, GI wire rope for blade and extension tube, GI wire rope anchor for motor chassis, power system switch gear protection complete all as specified and as directed by manufacturer/ Engineer-in-Charge. Make :- Ecoair model No Ultra ULTFN7E or equivalent in Kelley, Blade Tech
Note for item No 150 :- (a) The unit quoted rate shall be included the cost of AMC for smooth functioning of above mentioned system for 12 months after actual completion of work.
(b) During maintenance period, if he fails to do so, the Accepting Officer has all the right to recover the cost incurred to make the system functional from the contractor, the way it deems appropriate.
(c) To make necessary arrangement to provide three phase power upto the HVLS fan will be the responsibility of the contractor and cost for the same shall deem to be included in the unit quoted rate.
(d) Necessary T&P and equipments like boom lift/ scaffolding, safety belt etc will be arranged by the contractor and cost for the same shall deem to be included in the unit quoted rate.
Design, installation, testing and commissioning of tricking water cascade system consists of water level independent 9.5' length x 8' height x 4" width, stainless steel 304 grade jet - 01 No, complete assembly connected through 1 HP open well sub mersible mono block water cooled pump set, single phase, 1440 RPM, 240 V, 50 Hz - 01 No, provision of inlet and outlet connections using 10 Kg/Sqcm grade UPVC pipes 40 mm dia along with control butterfly valves complete, provision of ON/OFF control MCB box, single phase, 240 V, 4 way, 50 Hz consisting of 1 x isolator 40 Amps and 1xSPN MCB 40 Amp for operation and as incommer control, wiring with 2.5 sqmm copper conductor cable single core wires from control box to motor, provision of all accessories, connection of electrical and water supply services, testing and commissioning complete all as specified and directed.
M&L 32 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20°C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, complete to walls, ceilings or in floors etc. all as specified and directed. Make : SFMC, Prince, KPT
Note for item No 156 :- (a) The unit rate shall include connecting to existing GI pipe and with all fittings as directed.
(b) The unit rate shall be include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
(c ) Wall thickness of pipes shall be all as per IS : 15801
Cutting the existing GI/PPR pipe size 40/50 mm and making Tee joint for taking branch connection including GI fitting such as Tee, Union etc complete all as specified and as directed.
Supply and fixing PP-R Gate valves (brass insert) of size 32 MM dia as per requirement of the site complete all as specified and as directed.
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down unserviceable earthing all as specified and directed. Make : Model HTSP 317 of safeTrode or equivalent in ISG Global/ ERICO.
The unit quoted rate shall deem to be included for the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for guidance only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(vi) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(vii) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(viii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained.
(ix) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(x) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(xi) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end (copper strip will be measured and paid separately).
(xii) The electrode shall carry manufacturer's name .
(xiii) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xiv) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xv) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(xvi) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
(xviii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(xix) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concern.
S&F Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc all as directed. Note : All Joints should be joined by Exothermic Welding or Brazing.
Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit including taking down existing one complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model EGTEK3LC of ISG Global or equivalent in ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
S&F air termination sigle pointed aluminium rod of 12mm dia and 300mm length fixed to aluminium strip 25 x 3 mm including nuts, bolts and washers complete all as specified and directed the Engr in charge.
Supply and fixing alluminium strip 25 x 3mm thick with saddles and fixing screws etc. for roof conductors above ground all as specified and as directed.
Supply and fixing Galvanised iron strip 32 x 6mm thick as earthing lead fixed to roofs/buried in ground etc all as specified and as directed.
S&F epoxy base insulators of suitable size 40mm height for fixing GI earth strip on wall/ceiling/floor/poles etc all as specified and as directed.
M&L for earth test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw all as specified and directed.
M&L Brazing/ exothermic welding arrangement for existing copper strip of size 32x6 mm/ 20x3 mm thick complete all as specified and as directed.
M&L Connecting of copper strip with aluminum strip including bi-metal nut, bolts and washers complete all as specified and directed.
J and K constructions company
Lucky Enterprises
M/S SRI BALAJI ENTERPRISES
pk janardhanan
A.GOVINDARAJ
KSR AND COMPANY
chowdeshwariconstructionco
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .