Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.5 LAccepted-AOC 41 A COLONELGANJ CANTT FATEHGARH DISTT FARRUKHABAD UP 209601 | FATEHGARH | FARRUKHABAD | UP | 209601 | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹15.9 L+₹2.1 L (15.0%)Rejected-Finance | 2 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹16.5 L
EMD Value
₹33,000
Closing Date
15 Mar 2022, 6:00 pmClosed
AGE(I) Fatehgarh
AGE(I) Fatehgarh
REPAIR/REPLACEMENET OF LT NETWORK, LT PANELS, CONNECTED WORKS AND OTHER ALLIED WORKS AT FATEHGARH CANTT
2022_MES_506569_1
AGE(I) /FAT/ET-53 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE (I) Fatehgarh
PLEASE REFER TO TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
AGE (I) Fatehgarh
₹33,000
Yes
14 May 2022
8 Feb 2022
19 Mar 2022
8 Feb 2022
15 Mar 2022
24 Feb 2022
8 Feb 2022 - 23 Feb 2022
Amount
Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft /loose soil complete all as specified and as directed for laying of under ground cable, foundation of pole and stay etc. complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering and well remmining in layers not exc 25 cm complete all as specified and as directed
Removing excavated material n.exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point all as directed.
Dismantling of overhead ACSR conduction of any size including removing of PG Clamps jumpering etc and kept in safe custody for reuse serviceable ACSR in the work & removing unserviceable conductor from site complete all as specified & as directed.
Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolition of concrete excavation and earth work as reqd. and removing the same from site complete all as specified & as directed.
Dismantling of cross arms of MS channel or angle section etc complete fixed on RCC/steel tubular poles carefully including separating and setting a side serviceable cross-arms for reuse in the work and removing unserviceable cross arms complete all as specified and as directed.
Dismantling of insulators of any type & size from position including separating & setting a side serviceable insulators for reuse in the work & removing unserviceable insulator from site complete all as specified & as directed.
Dismantling of old PCC/steel tubular pole of any size with necessary disconnection of electric wire, demolition of concrete foundation including excavation, earth work as reqd & removing the same from site complete all as specified and as directed.
Supply & errection of steel tubuler swaged & welded pole 9.0 m long type 410 SP- 31 complete with CI base plate and finial tapper plug , bolts nuts screw conforming to IS: 2713 (part I to III) complete painting of pole with two coat of aluminium paint over a coat of red oxide primer and applying one coat of synthetic enamel paint alternate yellow & black strips painting ( 5 Nos each strip 300 mm wide ) all as specified and directed.
Errection only steel tubuler swaged & welded pole 9.0 m long type 410 SP- 31 complete with base plate, finial tapper plug, bolts nuts screw conforming to IS: 2713 (part I to III) incl complete painting of pole with two coat of aluminium paint over a coat of red oxide primer and applying one coat of synthetic enamel paint alternate yellow & black strips painting ( 5 Nos each strip 300 mm wide ) complete all as specified and directed.
M & L for preparing old painted surfaces by scraping and removing old paints,rust etc from steel tubular poles (above the planting depth and PCC coping of 9.0 Metre long pole) and Mild Steel cross arms, cable protection pipe,brackets etc and applying one coat of synthetic enamel paint alternate yellow & black strips painting ( 5 Nos each strip 300 mm wide) and remaining portion of pole and cross arms,cable protection pipe,brackets etc painted with one coat of aluminium paint including marking of pole No with black background and white lettering with all arrangement for ladder etc all as specified and directed .
Supply and lay sand with approved fine grade around cable in cushioning for protection of under ground cable complete all as specified and as directed
Supply and lay burnt best quality locally available old size sub class 'B' bricks laid in trenches perpendicular to U/G cable for cable protection complete all as specified and as directed.
Laying only serviceable bricks obtained from the items specified here-in-before (i.e during taking out of under ground cable),laid flat dry, in trenches with width of the bricks laid to the axis of cable for protection of cable complete all as specified and as directed
Taking out unserviceable LT U/G cable from trenches 6 Sqmm to 10 Sqmm size 2/4 core complete all as specified and as directed.
……..Ditto as above but for size 16 Sqmm to 50 Sqmm …Ditto……….
……..Ditto as above but for size 70 Sqmm to 95 sqmm …Ditto……….
Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 95 Sqmm 3.5 core complete all as specified and as directed
……..Ditto as above but for size 70 Sqmm 3.5 core …Ditto……….
……..Ditto as above but for size 50 Sqmm 3.5 core …Ditto……….
……..Ditto as above but for size 35 Sqmm 3.5 core …Ditto……….
……..Ditto as above but for size 25 Sqmm 4 core …Ditto……….
……..Ditto as above but for size 16 Sqmm 4 core …Ditto……….
……..Ditto as above but for size 10 Sqmm 4 core …Ditto……….
……..Ditto as above but for size 10 Sqmm 2 core …Ditto……….
……..Ditto as above but for size 6 Sqmm 2 core …Ditto……….
Relaying of existing serviceable underground cable of size 6 Sqmm to 10 Sqmm 2/4 Core obtained from dismantling complete all as specified and as directed.
Relaying of existing serviceable underground cable of size 16 Sqmm to 50 Sqmm 3.5 Core obtained from item dismantling complete all as specified and as directed.
Relaying of existing serviceable underground cable of size 70 Sqmm to 95 Sqmm 3.5 Core obtained from item dismantling complete all as specified and as directed.
M&L straight through joints( epoxy) for LT underground cable including joint kits suitable for aluminium conductor cable 50 Sqmm 3.5 core
……..Ditto as above but for size 25 to 35 Sqmm 3.5/4 core …Ditto……….
……..Ditto as above but for size10 to 16 Sqmm 4 core…Ditto……….
M&L outdoor LT END Termination Heat Shrink Kits for LT underground cable suitable for aluminium conductor cable of size 6 sqmm to 16 Sqmm complete all as specified and as directed.
M&L outdoor LT END Termination Heat Shrink Kits for LT underground cable suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm (3.5/4C) complete all as specified and as directed.
M&L outdoor LT END Termination Heat Shrink Kits for LT underground cable suitable for aluminium conductor cable of size 70 sqmm to 150 Sqmm (3.5/4C) complete all as specified and as directed.
M&L outdoor LT END Termination Heat Shrink Kits for LT underground cable suitable for aluminium conductor cable of size 185 sqmm to 240 Sqmm (3.5C) (complete all as specified and as directed.
Labour only for making holes of 15 mm dia on LT pole at top & bottom (above Copping ) for drawing of street light connecting wire inside the pole complete all as specified and as directed.
S & F in replacement of 80 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified and as directed.
S&F in replacement of 50 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified and as directed.
S&F in replacement of 40 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified and as directed.
S&F in replacement of 25 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified and as directed.
M & L for MS clamp made out of 50x6 mm flat iron bending cold or hot,drilling holes for bolts , in any shape or size as indicated or directed and inclusive of one primer coat,one under coat and one finishing aluminium coat of paint. complete all as specified and as directed.
S&F in replacement of cable junction box made of polycarbonate thermoplastic , weather , water & dust proof , fire retardant with 4 Nos aluminium bus bar of size 25 mm x 3 mm mounted on porcelain/ cast resin insulators with MCB SP 0.5 A , polyamide threaded cable glands , lock nut fixed on PCC/Steel pole including clamp made out of 20x3 mm MS flat iron complete all as specified and as directed
M & L for Boring holes horizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 80 mm bore(dia) for passing UG cable, complete all as specified and as directed. NOTE : - GI Pipe laid will be measured and paid separately under respective item
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth strip 25 x 4 mm by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown iln electrical plate No. 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) complete all as directed incl dismantling of exsisting earthing. ( Note :- On testing after completion if desired earth resistence is not obtained, the earthing will be redone at no extra cost.)
Demolition of concrete of any description and in any position or not other wise spccificly provided complete all as specified and as directed.
M & L for cement concrete type C2 , 1:3:6 using ( 40 mm graded aggregate) in foundation of LT pole/ stay, including necessary form work all as specified and directed.
M & L for cement concrete type B-1, 1:2:4 using (20 mm graded aggregate) including formwork for coping of LT pole complete all as directed.
M & L Brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:4 all as specified and as directed.
Demolition of brick wall built in cement mortar including all quoins,arches,pillars etc excluding precast concreta articles complete all as specified and as directed.
M&L Brick work with sub class 'B' bricks,old size brick, straight or curved on plan to any radius in half brick wall, built in CM 1:4 . complete all as specified and as directed.
M & L for 15 mm thick rendering in cement morter (1:4) on fair face of brick or concrete surface finished even and fair with and including M&L preparing surfaces on wall plastered new surafaces and applying Three coats of white wash complete all as specified and as directed.
M & L for straining of Aluminium conductor steel reinforeced (ACSR) on over head LT electric line required sag and binding the conductor with insulator and jumper with aluminium binding wire conforming to IS:398 Part-II complete all as specifie and as directed.
……ditto as above…. but refixing and restringing serviceable ACSR (any size) as recovered from item serial No-4 here-in-before including binding wire, line taps etc complete all as directed.
S & F cross arms made out of mild steel channel or angle section of reqd size and shape including clamp, back plate with bolts, nuts & washers drilled for insulator bolts, welding, bending cold or hot in any shape or size as directed and painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & as directed.
Fixing only cross -arms , bracing as obtained dismentling complete all as specified & as directed.
S & F stay assembly complete with all accessories and stay clamps all as shown in electrical plate No 1 of SSR Pt-1 with using stay rod of 16 mm dia complete all as specified & as directed.
S & F loop type insulator vitreous procelain white, brown or green small size with overall dimensions 65 x 90 mm and clearance of hole 16 mm complete all as specified & as directed.
S & F pin type insulator porcelain vitreous, white, brown or green including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut 100 mm height, 65 mm dia for 1100 volts grade dismentling
……ditto as above…. but fixing only old serviceable pin type insulator as obtained from dismantling complete all as specified & as directed.
S & F shackle type porcelain vitreous white, brown or green insulator of size 75 mm height 90 mm dia including MS strips 31x3 mm washers, insulator bolts 12 mm dia & nuts suitable for working pressure 1100 volts grade all as directed.
……ditto as above….but fixing oly old serviceable shackle type insulator as obtained form dismentling complete all as specified & as directed.
S & F galvanised stay strand of size 7/3.15 mm with necessary binding work with stay insulator, clamp and stay bow complete all as specified & as directed.
S&F street light bracket made out of GI tubing 40mm bore medium grade n.exc 1.5 metre long bent to shape as directed including suitable MS clamp of FI 50x6mm with MS bolts nuts and washer fixed to steel tubular pole/PCC pole duly painted with two coats of aluminium paint over a coat of red oxide primer inclluding dismantling existing street light complete all as specified and as directed.
Taking out unserviceable street light connecting lead and S&F PVC insulated stranded copper conductor cable three core 650/1100 volts grade of size 1.5 Sqmm complete all as directed.
M & L for Cutting of tree branches touching LT overhead lines to maintain a clearance of 1.50 metre from the overhead line to near by trees complete all as directed. Note: The scop of work shall be repeated in three months.
Dismantling existing unserviceable feeder pillar box including disconnection from different sites complete all as specified and as directed.
Fabrication, supply, installation, testing and commissioning in replacement of outdoor type feeder pillar box floor mounted made out from 3.15 mm thick MS sheet ( CPRI type tested) with canopy type roof, over all size 0.75 x 0.60 x 0.30 m front operated, two part hinged doors with locking arrangement comprising of copper bus bar suitable for 3 phase, 4 wire, 415 volts,50 Hz, AC supply mounted on suitable bus bar insulators, 200 Amps rating suitably drilled and tapped for bolts with openable two part front and rear shutter with heat strinkable PVC sleeving having RYB-B colour code drilling holes for connection of incoming and outgoing cable, complete powder coated painting, testing and installation on PCC/brick foundation, connection of cable with suitable aluminium lugs all as specified and directed.( Note :-MCCB will be measured and paid separately.)
Fabrication, supply, installation, testing and commissioning of out door type LT Feeder pillar box 0.90 m x 0.75 m x 0.45 m in depth made out of 3.15mm thick CRCA sheet ( CPRI type tested) and MS structural section of 50 x50 x 6 mm comprising of copper bus bar suitable for 3 phase, 4 wire, 415 volts,50 Hz, AC supply mounted on suitable bus bar insulators, 200 Amps rating suitably drilled and tapped for bolts with openable two part front and rear shutter, hinged front and rear panels and locking arrangement, bottom plate provided with the requires numbers of cable entries / opening including cable glands and cable lugs , PVC insulated /PVC sleeves 1100 volts grade maintaining conventional colour code, painting complete embedded in PCC 1:3:6 type C-2 ( using 40 mm graded aggregate ) n. exc. 0.45 cum and provision of following accessories complete all as specified and as directed ( Note :-MCCB will be measured and paid separately.)
S & F MCCB 200 Amps, 4 pole, 415 volts, 50 Hz 25 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides complete all as specified and as directed
S & F MCCB 160 Amps, 4 pole, 415 volts, 50 Hz 25 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides complete all as specified and as directed
Disconnection and dismantling of existing serviceable under ground cable of size 6 Sqmm to 16 Sqmm 2/4 core from LT Panel/FPB and taking out cable/cable loop from underground by excavtion of soft/loose soil and insertion of heat shrinkable PVC colour sleeves on cable cores and crimping of suitable size aluminium cable lugs as required and refixing the same in its original position complete all as specified and as directed.
Disconnection and dismantling of existing serviceable under ground cable of size 25 Sqmm to 70 Sqmm 3.5/4 core from LT Panel/FPB and taking out cable/cable loop from underground by excavtion of soft/loose soil and insertion of heat shrinkable PVC colour sleeves on cable cores and crimping of suitable size aluminium cable lugs as required and refixing the same in its original position complete all as specified and as directed.
Disconnection and dismantling of existing serviceable under ground cable of size 95 Sqmm to 240 Sqmm 3.5/4 core from LT Panel/FPB and taking out cable/cable loop from underground by excavtion of soft/loose soil and insertion of heat shrinkable PVC colour sleeves on cable cores and crimping of suitable size aluminium cable lugs as required and refixing the same in its original position complete all as specified and as directed.
S & F pre cast RCC cover slab over earth pit size of exc 300x300x50 mm but n.exc 450x450x50 mm including reinformement (8 mm dia bars both ways @ 100 mm c/c) etc, including dismatling complete all as specified and directed.
S B ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .