Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC R O KHREW TEH PAMPORE DISTT PULWAMA PIN 191103 J K | PULWAMA | JAMMU AND KASHMIR | 191103 | L1 | Accepted-AOC Accepted Being L1 | |
| 2 | L2₹10.3 L+₹42,635 (4.31%)Rejected-Finance R O IQBAL MARKET AALI MAJID EIDGAH SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L2 | Rejected-Finance Other than L1 |
Tender Value
₹10.8 L
EMD Value
₹21,600
Closing Date
17 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (K)
AGE (I) CIF (K) SHALATENG
PROVISION OF COMPUTER ROOM AT HAIDERBEG UNDER AGE (I) CIF (K).
2021_MES_487439_2
CA NO AGE (I) CIF (K) - 57/2021-22
Open Tender
Civil Works
Item Rate
180 days
SHALATENG
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
AGE (I) CIF (K)
₹21,600
Yes
22 Dec 2021
26 Nov 2021
20 Dec 2021
26 Nov 2021
17 Dec 2021
3 Dec 2021
60 days
Amount
B/R Works: Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil, complete all as specified and as directed by the Engineer-in-Charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying of cable and foundation of poles, stays etc. n exc 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil, complete all as specified and as directed by Engineer-in-Charge.
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified as directed by the Engineer-in-Charge.
Brick work with sub class `B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6, complete all as specified and directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and as directed by Engineer-in-Charge.
Reinforced cement concrete (Nominal mix) 1:1.5:3 type A-1 using 20mm graded crushed stone aggragte as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified as directed by the Engineer-in-Charge.
Reinforced cement concrete (Nominal mix) 1:1.5: 3 type A-1 using 20mm graded crushed stone aggragte as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified as directed by the Engineer-in-Charge.
Reinforced cement concrete (Nominal mix) 1:2:4 type B-1 using 20mm graded crushed stone aggragte as in columns, pillars,piers, posts and struts., complete all as specified as directed by the Engineer-in-Charge.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions, complete all as specified as directed by the Engineer-in-Charge.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc., complete all as specified and directed by Engineer-in-Charge.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces, complete all as specified as directed by the Engineer-in-Charge.
TMT steel bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified as directed by the Engineer-in-Charge.
TMT steel bars 6 to 8mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified as directed by the Engineer-in-Charge.
Mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, conforming to Fe 410 -W (Gde- E- 250) quality- A complete all as specified and asdirected by Engineer-in-Charge.
Mild steel work as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, conforming to Fe 410 -W (Gde- E- 250) quality- A complete all as specified and asdirected by Engineer-in-Charge.
Mild steel work as in Plates (plain or chequered) channels, quare cut or notched (ordinary and counter sunk) forming holes, without any attachment, conforming to Fe 410 -W (Gde- E- 250) quality- A complete all as specified and asdirected by Engineer-in-Charge.
Rendering 10mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:6, surface finished even and smooth without using extra cement, complete all as specified and directed by the Engineer-in-Charge.
Rendering 15mm thick on brick work or concrete surface in cement mortar 1:4, finishing surfaces fair and even, complete all as specified and directed by the Engineer-in-Charge.
Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer, complete all as specified and as directed by the Engineer-in-Charge.
Preparation of new plastered / unplastered surfaces of walls and applying two coats of distemper oil emulsion over one one coat of primer, complete all as specified and as directed by the Engineer-in-Charge.
Rendering 3 mm thick wall care cement based putty on walls (JK /Birla white), complete all as specified and directed by the Engineer-in-Charge.
Hardcore of broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate, 75 mm thick as in plinth protection laid in alternate bays (n exc 2 Sqm each) and finished even and fair without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight, complete all as specified and as directed by Engineer-in-Charge.
Plain cement concrete, 1:4:8, type D-2 using 40mm graded crushed stone aggregate, 100mm thick, as in sub-base of floor/path etc. finishing surfaces even and fair, complete all as specified and as directed by the Engineer-in-Charge.
Plain cement concrete, 1:2:4, type B-0 using 12.5mm graded crushed stone aggregate, 25mm thick, surface finished fair to receive top layer of flooring, complete all as specified and as directed by the Engineer-in-Charge.
Pre-painted galvalume aluminum zinc coating GI based corrugated profile steel sheet 0.50mm thick of colour as approved by AGE(I), having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by the Engineer-in-Charge.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of colour as approved by AGE(I), having tensile strength of 550 Mpa as in roof covering/cladding to ridges, valley gutters etc. fixed with self tapping screws, complete all as specified and as directed by the Engineer-in-Charge.
Preparation of newly untreated steel or iron surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide or zinc chromate,complete all as specified and as directed.
Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (, complete all as specified and directed by Engineer-in-Charge. Note:- Fillets, metal frame work and G.I. wire mesh paid separately under respective items of this BOQ.
Anodised aluminium snap grid frame work of size 605 x 605 mm for false ceiling, complete all as specified and directed by the Engineer-in-Charge.
Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified, complete all as specified and as directed by Engineer-in-Charge.
Plain, black, mild steel sheeting, 1mm thick as in eaves boarding, ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed), complete all as specified as directed by the Engineer-in-Charge.
Powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. (minimum thickness of powder coating 50 micron), complete all as specified and directed by Engineer-in-Charge.
Powder coated (minimum thickness of powder coating will 50 micron ) anodised aluminium Doors shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 02 nos in each door hinges, anodised aluminium snap beading screws etc complete all as specified. windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engineer -in - Charge.
Powder coated (minimum powder coating thickness 50 micron ) anodised aluminium windows and ventilators shutters, side sliding /hung type without sash bars, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws anodised aluminium fitting such as peg stays snap long (1 no) hinges type B-21 100 mm long (2 nos) suitable handle (1 nos), complete all as specified and as directed by the Engineer-in-Charge.
Sheet glass 4mm thick ordinary quality and glazing with in aluminium frames including necessry jointing cleats, glazing pins, rubber packing, aluminium snap beading, screwa, anodised aluminium fitting as required in squares exceeding 0.5 Sqm in each pane, complete all as specified as directed by the Engineer-in-Charge.
ACP sheet 1mm thick, including necessry jointing cleats, glazing pins, rubber packing, aluminium snap beading, screwa, anodised aluminium fitting as required in squares exceeding 0.5 Sqm in each pane, complete all as specified as directed by the Engineer-in-Charge.
Mild steel galvanised wire cloth 0.63mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks, wire staples or beading etc, ccomplete all as specified and as directed by the Engineer-in-Charge.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) with and fixing clips of sheet, cast or excluded sections and fixing bolts and sliding bolts of excluded sections or cast aluminum alloy and fixed, 250 mm long, complete all as specified and directed by the Engineer-in-Charge.
Non skid ceramic coloured tiles Ist quality 7 to 8mm thick, (square/ rectangular), area of each tile exceeding 0.18sqm, but not exceeding 0.38 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and as directed by the Engineer-in-Charge. Note: Colour and shade of tiles shall be approved by AGE(I) and contractor shall not have any claim whatsoever on this account.
E/M Works: Point wiring with 1.5 sqmm copper conductor (Multistranded) PVC insulated and unsheatheted FRLS electric cable 1100 volts grade and including PVC casing caping/conduit pipe of suitable size with all fittings accessories and including PVC insulated electric cable 1100 volts, 1.5 sqmm (multi stranded) copper conductor single core (Green colour) cable as continious earth wire connected to common earth dolly including sunk sheet terminal box made out of 1.6 mm thick MS sheet concealed on wall or on surface as per site requirement and making good distrubed surface of wall ,covered with 3 mm thick plastic laminated for mounting of switches, socket, fan regulators etc., complete all as specified and directed by the Engineer-in-Charge for the following:-
One light /fan/bell point controlled by one No, one way 5 Amps switch. complete all as specified and as directed by the Engineer-in-Charge.
One 3/5 pin socket outlet, 5 Amp, independent, controlled by one No. one way switch on independent board, complete all as specified and as directed by the Engineer-in-Charge.
One 3/5 pin socket outlet, 5 Amp controlled by one No, one way switch on same board, complete all as specified and as directed by Engineer-in-Charge.
All as per serial item No 42 here-in-before ,but for one socket out let 15 Amp on the independent board with 2.5 sqmm copper conductor multistranded PVC insulated and unsheathed electric cable 1100 volts (ISI MARKED) including PVC insulated and unsheathed electric cable 1100 volts, 2.5 sqmm copper stranded conductor as continious earth wire connected to common earth dolly, complete all as specified and as directed by the Engineer-in-Charge.
Sheet metal enclosure factory made (double door) shutter type for MCB DB TPN horizental type, 440 Volts, 4 ways with 200 Amps rated bus bar, neutral link, earth bar, complete all as specified and as directed by the Engineer-in-Charge.
MCB TPN, 100 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type, including taking down old existing, complete all as specified and as directed by the Engineer-in-Charge.
MCB SP, 5 -32 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type, including taking down old existing, complete all as specified and as directed by the Engineer-in-Charge.
Piano type switch one way, SP, flush type, 5 Amps, 230 volts AC, 50 Hz, complete all as specified and as directed by the Engineer-in-Charge.
Piano type socket outlet, flush type, 2 in 1, 3 pin, 5 Amps, 230 volts AC, 50 Hz, complete all as specified and as directed by the Engineer-in-Charge.
Piano type switch socket combination, flush type, 5 in 1, 15 Amps, 230 volts AC, 50 Hz, multipurpose type, complete all as specified and as directed by the Engineer-in-Charge.
Ceiling rose surface type, 65 mm x 50 mm three terminals/PVC/polycarbonate, isolated body fixed on PVC block,complete all as specified and as directed by the Engineer-in-Charge.
Electronic fan regulator flush mounting step type 300-400 Watts, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed by the Engineer-in-Charge. Make: Havells Cat part No LHEXBLP7PN1W018 or equivalent in Bajaj/Crompton Greaves /Phillips
Lamp holder insulated body with back plate suitable for batten fitting including providing LED 9 Watt lamp , complete all as specified and as directed by the Engineer-in-Charge. Make:- Anchor/Havells/Plaza/SSK.
Supply and fixing Ceiling fan 1400mm sweep electric driven single phase 240 Volt, 50 Hz, with blades and electronic regulator, complete all as specified and directed by Engineer-in-Charge. Make:- Havells/Usha/Orient
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc., including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge.
M/S SHIMAR STAR GLACIER
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .