Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC | L1 | Accepted-AOC lowest quoted amount | |
| 2 | L2₹31.3 L+₹1.2 L (4.09%)Rejected-Finance | L2 | Rejected-Finance Rejected
because it
has been
found
second
lowest
quoted
amount | |
| 3 | L3₹31.6 L+₹1.5 L (5.02%)Rejected-Finance VILLAGE POST SARAIYA NO 1 CHOLAPUR DISTRICT VARANASI U P | CHOLAPUR | VARANASI | UTTAR PRADESH | L3 | Rejected-Finance Rejected
because it
has been
found
third
lowest
quoted
amount |
Tender Value
₹30.1 L
EMD Value
₹1.5 L
Closing Date
31 Jul 2020, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Unit In- Charge
Add- Camp Office, 17-H Ashok Vihar Colony Paharia Varanasi 221007
Renovation and Upgradation of Pharmacy Unit of SOWA RIGPA Dept. at Township area of Institute at CIHTS, Sarnath Varanasi
2020_UPRNN_495239_1
24/e-Tender/RNN/Bhadohi Unit/20
Open Tender
Civil Works - Buildings
Item Rate
45 days
Sarnath Varanasi
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
U. P. Rajkiya Nirman Nigam ltd
₹1.5 L
8 Oct 2020
21 Jul 2020
31 Jul 2020
21 Jul 2020
31 Jul 2020
21 Jul 2020
90 days
Amount
Renovation and Upgradation work (Cement and Steel will be provided by UPRNN separately)
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover.RS2
Providing and fixing of Gal-Volume sheet - Mist White Colour for roofing of 0.47mm TCT, Mist White Colour for wall cladding and Squirrel Grey for facias of 0.50 mm TCT complete in all respect. The sheets would be of double locking profiled with seam less joints. As per approved drawings, 3D drawings and direction of Engineer - in -charge.Roofing Sheeting
Providing and fixing Gal Volume sheet roofing accessories 0.47mm TCT , epoxy primer on both side of the sheet fixing with self drilling/ self tapping screws in all complete: (1)Flashings/ Aprons (Upto 600 mm)
Providing and fixing Gal Volume sheet roofing accessories 0.47mm TCT , epoxy primer on both side of the sheet fixing with self drilling/ self tapping screws in all complete:(2)Gutter.(600 mm over all girth)
Providing and fixing Gal Volume sheet roofing accessories 0.47mm TCT , epoxy primer on both side of the sheet fixing with self drilling/ self tapping screws in all complete: (3)Ridges plain(500-600mm)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a primer using structural steel etc. as required all complete.In gratings,frame ,guard bar,ladder,railings,brackets ,gates and similar works.For M.S. Ladder
Providing and Fixing of Steel Rack as per drawing with 20 guage of tray and framing angle is 16 guage including painting with gray colour paint in all complete as per instruction of Engineer-In-Charge.Rack4(3500x2100x800).
Providing and Fixing of Steel Rack as per drawing with 20 guage of tray and framing angle is 16 guage including painting with gray colour paint in all complete as per instruction of Engineer-In-Charge. Rack1(4000x2100x800).
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile (600x600mm)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile (600x600mm)
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening“for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK.
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)Internal wall plaster
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)External Plaster Area
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Providing 40x5 mm flat iron hold fast 40cm long including fixing to frame with 10 cm long including fixing to frame with 10 mm diameter bolts ,nuts and wooden plugs and embedding in cement concrete block 30x10x15 cm 1:3:6 mix(1cement:3coarse sand :6 graded stone aggregate 20 mm nominal size)
P/F of Float glass panes 4 mm thick W1=(1.8x1.2=7Nos)W2=(1.8x1.2=6Nos.)
Provding and fixing bright brass tower bolts (barrel type) with necessary screws etc. complete (250x10 mm)
Provding and fixing bright finished brass handles with screws etc complete
Providing and fixing of GRC bracket in all complete.
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :150 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:150 mm diameter S.W. pipe
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For Fixed Portion :Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness Wall partitions/door.
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge.Pre-laminated particle board with decorative lamination on both sides
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/ Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600. Upto 5 mm depth and 5 mm width.
PARAG TECHNOBUILD PVT.LTD.
OM SAI CONSTRUCTION
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Tendernotice_1.pdf
Tender Document • 0.41 MB
tibbtiextend3007.pdf
Tender Document • 0.25 MB
tibbatiextend.pdf
Tender Document • 0.25 MB
BOQ_743209.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .