Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.5 LAccepted-AOC VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | 1 | Accepted-AOC LOWEST BIDDER | |
| 2 | 2₹9.3 L+₹44,484.55 (5.01%)Rejected-Finance NEAR PUMP HOUSE ROAD NEAR RED ROSE SCHOOL BABINA CANTT JHANSI DISTT UP 284401 | JHANSI | UTTAR PRADESH | 284001 | 2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | 3₹9.5 L+₹58,811.41 (6.63%)Rejected-Finance 640 MAIN ROAD BABINA CANTT JHANSI UP 284401 | JHANSI | JHANSI | UP | 284401 | 3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | 4₹10.0 L+₹1.1 L (12.6%)Rejected-Finance CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | 4 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹19,996
Closing Date
19 Jul 2023, 6:00 pmClosed
AGE I TALBEHAT
LAKEVIEW CAMP MIL STN TALBEHAT 284125
REPAIR/MAINT TO LT SWITCH GEAR AND CONNECTED WORKS AT MIL STATION TALBEHAT
2023_MES_594757_2
AGE(I)/TBT/TOK-33/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I TALBEHAT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE I TALBEHAT
₹19,996
Yes
1 Sept 2023
28 Jun 2023
21 Jul 2023
28 Jun 2023
19 Jul 2023
5 Jul 2023
Amount
Taking down old damaged Cross arms, bracing supports, clamps and back plates fabricated from structural steel sections including nuts, bolts etc.
Taking down old damage ACSR conductor of any size and type.
M&L for Cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate for foundations of poles, struts & stay assembly etc. all as specified and directed.
M&L for Cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate as in coping of poles etc. including fair finishing the exposed surface even and smooth with out using extra cement and necessary form work all as specified and directed
Excavation in in trenches not exceeding 1.5 mtrs wide & not exceeding 1.5 mtr in depth in soft or loose soil & getting out complete all as spfd & directed.
Removing excavated material not exceeding 50mtr &deposited where directed at a level not exceeding 1.5mtrabove the ground level.
Returning , filling in spreading, leveling, watering & well Ramming in layers not exc 25cm thick complete all as spfd & directed.
M&L for bricks common burnt sub class B designation for protection of cable complete all as spfd & directed.
M&L for natural local river sand for cable protection.
M&L in for cable XLPE insulated heavy duty electric cables with Stranded aluminium conductor, 1100 volts grade, passing through trenches/ducts/pipes and climbing on poles/walls including fixing with proper size of aluminium lugs in replacement of ACSR Conductor for the following sizes. NOTE:- 1. Excavation and earth work to be measured and paid separately.
10 Sq mm 2 Core (for street light)
10 Sq mm 4 Core (for Buildings)
25 Sq mm 4 Core. (for panel to panel)
50 Sq mm 3.5 Core (for panel to panel)
70 Sq mm 3.5 Core (for panel to panel)
95 Sq mm 3.5 Core.(for panel to panel)
185 Sq mm 3.5Core.(for Sub stn to Main panel)
M&L for Earthing complete with galvanized steel earth plate electrode 60cm X 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below ground level earth plate connected with GI earthing strip (25X4mm) as earthing lead for transformer/feeder pillar box etc. by means of bolts, nuts, check nut and washers of galvanized iron all as shown in Electrical plate No.3 of MES Sch part I and testing on completion. Necessary excavation and earth work included, adequate common slat, charcoal dust and funnel PCC (1:3:6) type C-1 pit with pre-cast RCC (1:2:4) type B-1 cover, 40mm thick reinforced with 6 mm dia bars, MS bar 3 Nos both ways funnel with 20,mm dia GI medium grade watering pipe earthing lead complete all as specified.
Supply and laying or fixing in replacement GI tubes light grade 25 mm dia, on place of rusted GI pipe in support of cables, on pole/wall/laid in floor/in trenches.
Supply and laying or fixing in replacement GI tubes light grade 40 mm dia, on place of rusted GI pipe in support of cables, on pole/wall/laid in floor/in trenches.
Supply and laying or fixing in replacement GI tubes light grade 50 mm dia, on place of rusted GI pipe in support of cables, on pole/wall/laid in floor/in trenches.
Supply and fixing MCCB, 415 volt, adjustable type, 36KA, 4 pole, capacity 250 Amp.
Supply and fixing PVC twin core flexible 1.5 sqmm cable for street light fitting
Supply and fixing Hot press PVC molded (Fire Proof) junction box of size 180 mm x 100 mm x 60 mm, complete with two No. aluminium bus bar of size 100 mm x 30 mm x 05 mm for phase and neutral, mounted on insulators, front opening door, locking arrangement and fixing with suitable size clamp and nut and bolt on pole, Including connection of incomer and out going cable by Galvanized iron nut bolt and washer of suitable size and proper lugs, making hole in bus bar . .
Note :- Debris obtained from all items should be removed in low lying areas as directed by Engr-in-charge out of MOD Land. (Rates quoted for items are deemed to be included for this, where removal of debris in the items is not considered.)
M/S Ritu Tandon
M/s Ravi Traders
HARNAM SINGH ANIL SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .