| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 LAccepted-AOC VILL PO BALGONA PURBA BARDHAMAN | BALGONA | PURBA BARDHAMAN | WEST BENGAL | L1 | Accepted-AOC Quoting Lowest rate | |
| 2 | L2₹36.4 L+₹24,171 (0.67%)Rejected-Finance CHALITIA BERHAMPORE MURSHIDABAD | BERHAMPORE | MURSHIDABAD | WEST BENGAL | L2 | Rejected-Finance Quoting Higher rate | |
| 3 | L3₹36.9 L+₹71,549 (1.98%)Rejected-Finance 159B M G ROAD HARIDEVPUR KOLKATA WEST BENGAL 700082 UDYAM WB 10 0018308 | KOLKATA | WEST BENGAL | 700082 | L3 | Rejected-Finance Quoting Higher rate |
| Sl No | Description | Qty | Unit | D.D ELECTRICALS L1 | MONDAL ENTERPRISE L3 | G.M.N. ENGINEERING L2 |
|---|---|---|---|---|---|---|
| 1.00 | EI Work :-Main Panel :-S & Installation of floor mounted cubical type compartmental dust vermin proof panel board of suitable size made with 20 mm (14 SWG) thick CRC sheet rain forced with individual hinged door for all compertment roviding uitable entilation system, cable alloy and ainting with two coat of synthetic enamale paint over one coat of R.O. primer, interconnection with uitable size Cu. wire / Strip bar with arth stud bolt in the body The panel omprising the ollowing as per direction of E.I.C. i) S&F 415 V 315 A. Incomer TPN Main witch (L&T)-1 no. ii) S&F 415 V 250 A. Outgoing TPN Main Switch (L&T)-1 nos. iii) S&F 415 V 125 A. Outgoing TPN Main Switch (L&T)-2 nos. iv) S&F 415 V 63 A. Outgoing TPN Main Switch (L&T)-2 nos. v) S&F 415 V 32 A. Outgoing TPN Main Switch (L&T)-2 nos. vi) S&F 415 V 600 A. Busbar hamber with 4 nos. copper Bar in sheet metal bax (16 SWG) with hinged type door with locking arrangement with telescopic screw - 1 no. vii) Ammeter Meter (0-60 A.) with Selector Switch (AE) - 1 no. viii) Voltmeter Meter (0 - 500 V.) with Selector Switch (AE) - 1 no. ix) 300 /5 A. C.T. Coil (AE make) - 3 nos. as per direction of EIC =---Test Certificate should be provided . | 1 | Item | 1,54,545 ₹1,54,545 | 1,51,505 ₹1,51,505 | 1,51,500 ₹1,51,500 Lowest |
| 2.00 | Supplying and fixing 8 way double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment 8way (Legrand/ Siemens ) Enclosure (607914) with 1 no 415 V 125 A. FP MCCB and 6 nos. 415 V 63 A. TP MCB and 6 nos. 240 V 6-32 A. SP MCB as required.(D-11/15,D-8/10,D-6/7)(Pannel will be installed after approval of drawing) | 2 | Nos | 35,411 ₹70,822 | 34,340 ₹68,680 Lowest | 34,398 ₹68,796 |
| 3.00 | Supplying and fixing double door Horizontal TPN MCB Distribution boardLegrand/ Siemens) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment --6 way(Legrand/ Siemens/ L&T ) Enclosure ( 607716) with 1 no. 415V 63 A. FP Isolator and 18 nos 240 V 6-32 A. SP MCB as required.(D-10/14) | 7 | NOS | 9,062 ₹63,434 | 8,965 ₹62,755 | 8,962 ₹62,734 Lowest |
| 4.00 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+10 way(Legrand/Siemens) Enclosure (607712) with 1 no. 240 V 40 A. DP MCB Isolator and 10 nos. 240 V 6-32 A. SP MCB as required.(D-9/13)(D-5/6)(D-6/7) | 20 | NOS | 4,888 ₹97,760 | 4,625 ₹92,500 | 4,621 ₹92,420 Lowest |
| 5.00Cables & It's protection pipe -Supply & Delivery of following size of 1.1 Kv grade XLPE/PVC armoured Al cable.(Polycab/Glostar /Havells ) --Test Certificate/Warranty Certificate should be submitted | ||||||
| 5.01 | 4 core x 95 sq mm(Panel to VTPN) | 45 | Mtr | 1,380 ₹62,100 | 1,330 ₹59,850 | 1,325 ₹59,625 Lowest |
| 6.00Laying of following size of 1.1 Kv grade XLPE/PVC armoured Al cable after cutting floor/pavement / wall/ and making holes incl. mbedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish. | ||||||
| 6.01 | 4 core x 95 sq mm | 20 | Mtr | 184 ₹3,680 Lowest | 195 ₹3,900 | 190 ₹3,800 |
| 7.00Laying of following size of 1.1 Kv grade XLPE /PVC armoured Al cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, aking holes etc. as necy. Mending good damages and painting. | ||||||
| 7.01 | 4 core x 95 sq mm | 25 | Mtr | 95 ₹2,375 Lowest | 110 ₹2,750 | 105 ₹2,625 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
17 Dec 2024, 11:00 amClosed
Superintending Engineer,Western El.Circle,PWD
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Repair and Renovation of Electrical Works of CST,IT and adjacent workshop building and SITC of RAC Machine at Bengal Institute of Technology, Katwa, Purba Bardhaman.
2024_WBPWD_773284_1
WBPWD/SEWEC /BED /NIQ-83 /2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
Purba Bardhaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹90,000
Office of the Superintending Engineer, Western Ele
13 Jul 2026
25 Nov 2024
19 Dec 2024
25 Nov 2024
17 Dec 2024
28 Nov 2024
25 Nov 2024 - 27 Nov 2024
27 Nov 2024
Amount
Supplying and fixing 8 way double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment 8way (Legrand/ Siemens ) Enclosure (607914) with 1 no 415 V 125 A. FP MCCB and 6 nos. 415 V 63 A. TP MCB and 6 nos. 240 V 6-32 A. SP MCB as required.(D-11/15,D-8/10,D-6/7)(Pannel will be installed after approval of drawing)
Supplying and fixing double door Horizontal TPN MCB Distribution boardLegrand/ Siemens) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment --6 way(Legrand/ Siemens/ L&T ) Enclosure ( 607716) with 1 no. 415V 63 A. FP Isolator and 18 nos 240 V 6-32 A. SP MCB as required.(D-10/14)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+10 way(Legrand/Siemens) Enclosure (607712) with 1 no. 240 V 40 A. DP MCB Isolator and 10 nos. 240 V 6-32 A. SP MCB as required.(D-9/13)(D-5/6)(D-6/7)
Cables & It's protection pipe -Supply & Delivery of following size of 1.1 Kv grade XLPE/PVC armoured Al cable.(Polycab/Glostar /Havells ) --Test Certificate/Warranty Certificate should be submitted
4 core x 95 sq mm(Panel to VTPN)
Laying of following size of 1.1 Kv grade XLPE/PVC armoured Al cable after cutting floor/pavement / wall/ and making holes incl. mbedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish.
4 core x 95 sq mm
Laying of following size of 1.1 Kv grade XLPE /PVC armoured Al cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, aking holes etc. as necy. Mending good damages and painting.
4 core x 95 sq mm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cable. 4 core x 95 sq mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.
4 core x 95 sq mm
Supplying & fixing 40 mm dia medium gauge GI Pipe( ISI-Medium) for Protection with necessary fittings and jointing metarials as required.(F-6/11)
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make:-Finolex/ KEI/Polycab/RR Kabel) partly in 20mm size PVC rigid conduit 'FR' (Precision mms make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall],with 1x22/0.3 (1.5 sqmm ) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan /call bell points with Modular type switch (Make:-Anchor Roma/Cabtree/Schneider /Legrand Myrius) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed](E-25/4) Average run 8 mtr.
Average run 6 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make:-Finolex/ KEI/Polycab/RR Kabel) in 20mm size PVC rigid conduit 'FR' (Precision MMS make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch(Make:-Anchor Roma/ Cabtree/Schneider /Legrand Myrius)on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. On Board(E-24/3a)
Cutting channel of suitable sizes on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below as per GS.19 mm dia 3 mm thick polythene pipe without earth continuity wire.(E-2/3a)
25 mm dia 3 mm thick polythene pipe without earth continuity wire(E-2/4b)
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make:-Finolex/ KEI/Polycab/RR Kabel) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. 2x 2.5 sqmm + 1x 1.5 sqmm.(Computer & Power Plug)(E-9/1)
3x1.5 sq mm(Separate & Excess Wiring)
2x6 sqmm+1x4 sqmm(SPNDB)
4x10 sqmm+2x6 sqmm(VTPN to PBDB & Industrial Socket)
2x4 sqmm+1x2.5 sqmm(AC Machine )
Finishing of the PVC insulated wire ends by socketting with pin/ ring type coppersockets and insulated tapes etc., including supplying sockets, tapes. 2.5 sqmm.(F-5/9)
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Make:-Anchor Roma/ Schneider /Cabtree/ Legrand Myrius), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular typeswitch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc(for computer point).
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Make:-Anchor Roma/ Schneider /Cabtree/ Legrand Myrius) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Make:-Anchor Roma/ Schneider /Cabtree/ Legrand Myrius), on S&F 2 Module GI Modular type switch board flushed in wall incl. making necy. connections as per GS.(E-17/5a)
Supply & Fixing 240 V, 25 A, Modular type starter (Make:-Legrand/Cabtree/ Anchor ) with 25A Modular switch type DP MCB (C Curve) and S&F 4 Module GI Modular type switch board flushed in wall incl. necy. connection as per GS.(E-19/17)
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall as per GS.240 mm x 200 mm x 65 mm(E-4/11)
150mm x 100mm x65mm
100mm x 100 mm x 65 mm
Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws.240 mm x 200 mm x 65 mm(E-5/13)
150mm x 100mm x65mm
100mm x 100 mm x 65 mm
Fittings and Fixtures :-Supplying of twin 230 V 18 W T8 LED Tube light with fitting complete with all accessories Make(Philips-TMC 502P2xTLED with PC body 2100 lm MAS LED Tube/Crompton-IGP-132LT8-16 with LTT8-8 aluminium body / Wipro aluminium body)Warranty Certificate should be submitted. (3 Years warenty)
Supplying of single 230 V 18W LED Tube light with fitting complete with all accessories & 230V. 20 W. T8-LED Tubes. Philips-TMC 502P 1xTLED with PC body 2100 lm MAS LED Tube/Crompton-IGP-131LT8-16 with LTT8-8 aluminium body / Wipro aluminium body) Warranty Certificate should be submitted.(3 Years warenty)
Fixing only Single/ twin Tube light with fitting complete with all accessories suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp as per G.S.(C-2/17)
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)(D-14/29)
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Make:-Anchor Roma/ Schneider /Cabtree/ Legrand Myrius)on existing Modular GI switch board with top cover plate incl. making necy. connections etc as per G.S.(E-18/10)
Supply & Delivery of 230V, 1 Star rated 48" (1200mm dia) ceiling fans complete with all accessories with safety wire & S3 Capacitor (Make - Crompton, HS PLUS / Orient, Summer King / Usha, Striker or as per direction of EIC) Warranty Certificate should be submitted. (2 Years warenty)
Supplying of 9"(13 cm) exhaust fan with blades & others accessories. (E.P.C. / Orient make)
Fixing of 9"(13 cm) exhaust fan after making hole in wall as per G.S. incl. necy. connection as per G.S.(C-4/28)
S&Fixing louver shutter/cowl on wall for 9"(13 cm) exhaust fan with necy. bolts & nuts as per GS.(D-4/32a)
S & Fixing 12 w LED bulb(Philips /CG/Wipro)
S&F 230 V. 32 A. (P+N+E) Industrial Plug socket on S&F suitable size of GI Modular type switch board with 1 no. 32 A. DP MCB for UPS on / in wall incl. necy. Connection as per GS. (Legrand) TEMPRA PRO INTERLOCKED(056669)
Timer DB :- S&F timer box consisting with 1 no. 220 V. 25A. DP MCB, 2 nos. 220V ,50Hz Power contactor MNX 25 , 1 no. toggle switch, 1 no. timer clock, 1 no. starter for mannual operation, Inditating lamps, connectors etc. incl. suitable size of interconnecting wire as reqd. as per GS. (Make:-L&T/Simens/ABB)
Earthing - Excavation of soil for installation of Earth Electrode and filling & ramming. - Soft soil.(G-1/1a)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GIpipe.(G-1/2a)
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the busbar as per GS.(G-2/4a)
Connecting the equipments to earth busbar incl. S & F 10 SWG GI (Hot Dip) wire on wall/floor as per G.S.(G-2/5)
Supplying and Fixing of following size PVC Rigid Conduit 'FR' [Precision mms Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. 20 mm dia.(E-16/7a)
25 mm dia (E-16/7b)
Supply & fixing of Industrial 415 V, 63A, 3P+N+E - FP metallic Plug & Socket with 63A FP MCB with P17 Tempra box in wall (Legrand/ Havells)
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. With 25x25x3mm angle iron support 300x50x1.25mm (18SWG) (D-14/34/ii)
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire. From 70sqmm to 150sqmm cable|(F-3/6)
SITC of Lightning Arrester :-S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1) [J-1/1]
S & F of 4 SWG GI (Hot Dip) wire on Parapet/Roof/Plinth/Surface of wall for lightning conductor as required (for Horizontal runs) with 40 mm long GI Staples spaced not exceeding 1300 mm apart incl. mending good all the damages to the building works [J-1/2]
S & F of 4 SWG GI (Hot Dip) wire on wall for the lightning conductor as required (for vertical run) with GI Staples (40 mm long) spaced not exceeding 1 Mtr. apart incl. mending good the damages to building works (excluding hire charges of scaffolding) [J-1/3]
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works: Length upto 0.5Mtr. [J-1/4a]
Making soldered joints between conductors, conductors and air terminals for 4 SWG GI (Hot Dip) wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint. [J-1/5]
Making soldered joints between conductors and down pipes/ other metallic objects for 14 SWG GI (Hot Dip) wire including supply of necessary 4 SWG GI (Hot Dip) wire, jointing materials and painting with 2 (two) coats of bituminous paint. [J-1/6]
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. [J-1/7]
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required. [J-2/13]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:ByISI-Medium GI pipe [G-1:2a] (02no for Building EI work and 10 no for LC work)
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil [G-1/1b]
RAC Machine Work:- Supply ,Installation ,Testing & Commissioning of Split type AC machine having colling capacity range (6.6KW-7.0KW),With fixed speed rotary compressor ,refrigerant gas R32/R410 BBE star rating-3(EER range 3.5 to 3.99),Air flow range CFM(780-850),both condencer and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391(Part-i &Part-II)with all amendments(Make:-Mitsubishi Electric/O General/ Hitachi/Mitsubishi Heavy)
Supply, installation, testing & commissioning of copper refrigeration pipe line for liquid and Suction line including vaccumiazation and Nitrogen of testing of following nominal size of soft/ hard drawn copper refrigerent piping for Split AC system, complete with fittings with adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XLPE class - O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 9mm. thickness for suction and liquid lines, all accessories as per specification etc. as required & as per direction of EIC with proper mending good damages to original finish. Mk. of Cu pipe - Rajco/ Ryoku/ Mandev/ Nippon Mk. of Nitrile Rubber Insulation - Aeroflex/ K-flex/ Accroflex/ Armacell. (a) 15.88 mm (5/8) O.D. (Thickness : 1mm) (Insulation : 9 mm) & (b) 6.4 mm O.D (1/4). (Thickness : 0.8mm) (Insulation : 9 mm)
Supply and Laying of 4 core2.5 sq.mm Ll KV grade unsheathed FR Cu cable with gas line as per direction of EIC for Indoor to Outdoor Communication for Split type AC m/c.(Make:- Polycab/ Havells/ KEI/RR Kabel)
Supply and Laying of 4 core 4 sq.mm 1.1KV grade unsheathed FR Cu cable with gas line as per direction of EIC for Indoor to Outdoor Communication for Split type AC m/c.(Make:- Polycab/ Havells/ KEI/RR Kabel)
Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. (Make: Suprime/Oriplast)
G.M.N. ENGINEERING (BID ID -5866525)
MONDAL ENTERPRISE (BID ID -5866462)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .